Loading...
HomeMy WebLinkAboutP_Design_105086971_V1_17121283.39'73.00'N01°32'53"E 299.93'73.00'70.00'S88°16'35"E 99.34'N01°32'53"E 299.01'73.00'73.00'70.00'83.01'S88°29'36"E 99.34'S88°16'35"E 99.34'S88°16'35"E 99.34'S88°16'35"E 99.34'LOT 4(6,954 SQ. FT)LOT 3(7,252 SQ. FT)LOT 2(7,252 SQ. FT)LOT 1(8,265 SQ. FT)SSSSSSWWW20' BSBL20' BSBL5' BSBL5' BSBL20' BSBL20' BSBL5' BSBL5' BSBL15' BSBL15' BSBL5' BSBL5' BSBL5' BSBL20' BSBL20' BSBL15' BSBL1+002+001142016044 11436 16204 11435 11445 11453 16220 12626 317002-166526 37.5 kVA 120/240V 316999-166523 25 kVA 120/240V (A) ERROR - SET SWITCH ID ERROR - SET SWITCH ID (ERROR-SET FUSE) SLAT8154 SE 162ND ST 114TH AVE SESS SS SSWWWWWWWWWWWWWWWSS JOB SITE 316999-166523 25 kVA 120/240V EXISTING 40T SW #T______ NEW 40T SW #T______ SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: Sapphire Homes, Inc 16834 SE 43rd ST Bellevue, WA 98006 Travis Kassebaum (206) 484-4321 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. STANDARD EASEMENT PROVISION An easement is hereby reserved for and conveyed to Puget Sound Energy, Inc., Telephone Co., Television Cable Co., and their respective successors and assigns under and upon the private street(s), if any, and the exterior ten (10) feet of all lots, tracts and spaces with in the plat lying parallel with and adjoining all street(s) in which to construct, operate, maintain, repair, replace and enlarge underground or ground-mounted appurtenances thereto for the purpose of serving this subdivision and other property with electric, gas, telephone and other utility service, together with the right to enter upon the streets, lots, tracts and spaces at all times for the purposes herein stated.105086971FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV N/A 101109015 N/A 108103767 N/A 593190248 N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Svc/MSA SITE SPECIFIC NOTES Phone INTOLIGHT Contact Information: N/A N/A SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: ___ AMPS 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4" BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE. ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY CABLES PER THE CIRCUIT ONE-LINE DIAGRAM. UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER PUGET SOUND ENERGY STANDARDS. AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3) MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE. (EXCAVATION: 3' SQ.) AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT. AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE STREET LIGHT STANDARDS. ) INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES AND DATES. POWER GENERAL NOTES - PLAT PROJECT 11. E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dave Honeysett (253) 245-0883 DAVID.HONEYSETT@PSE.COM PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: 1" = 50' THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 11/27/17 Nate Linville (253) 970-7284 11/27/17 N/A N/A N/A Nate Linville (253) 970-7281 Required City of Renton Cascade Greens 4 Lot Plat 1Ø PRIMARY LE, SET PM TRF, INST 2 - STUBS 11427 SE 162ND ST, RENTON, WA 98055 N/A N/A N/A 105086971 AS NOTED 1 OF 2 KING N/A N/A CSPSKEPM NE-29-23N-05E N/A N/A 2305E113 2305E136 2305E113 ROL-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105086971 N/A N/A 505052286 N/A AT P01: REPLACE REMOVE EXISTING B/O 1981 40' DISTRIBUTION POLE TRANSFER EXISTING 25kVA 1B TO NEW POLE TRANSFER EXISTING LUMINAIRE TO NEW POLE (SLAT8154) TRANSFER EXISTING 1Ø 1/0 TERMINATION TO NEW POLE -INST. 1 - 45' CL2 DISTRIBUTION POLE PER STD 6010.1000 (PD452) -INST. 1 - 9' 8P XARM -INST. 1 PTP & INSULATOR -INST. 2 - STEEL ARM PINS & INSULATORS -INST. 1 - BOLTED STIRRUP & HOT CLAMP ON BØ -INST. 1 - L/B C/O ON NEW FG ARM, FUSE AT 40T PER STD 6043.1000 (TSU1C1) -INST. 1 - 12kV 1/0 SOL CS PIN TERMINATION PER STD 6041.3000 (TER10JC) -INST. CABLE # BØ-EHO831 -INST. NEW SW #T______ -INST. 1 - 2" PRIMARY RISER ON EXISTING S/O BRKTS PER STD 6042.1000 (RIS2CSS) EXISTING GRID 316999-166523 COMMUNICATIONS TO TRANSFER AT V01: NEW -INST. 1 - 36" X 42" X 38" UNI-STRUT MP HH W/21" X 24" ACCESS HOLE PER STD 6045.1010 (MINI1SR) -INST .1 - 37.5kVA 120/240V PM TRANSFORMER -INST. 1 - L/B ELBOW & 1 DUST CAP PER STD 6041.1000 (ELB10J) -INST. 3 - #6-350KCMIL 6POS SEC CONNECTION BLOCKS W/5/8" STUD ADAPTER (MID: 4842002) -INST. GRID 317002-166526 SPAN NOTES SEE CABLE TABLE ON P2 FOR CABLE AND CONDUIT INFORMATION DEVELOPER & CUSTOMER NOTES: THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 -REQUIRED TO PROVIDE 6' X 6' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT V01 -REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT P01 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE -L&I INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION -RESPONSIBLE FOR ALL TREE TRIMMING AND BRUSH CLEARING OVERHEAD CIRCUIT MAP (2305E136) SCALE: 6" = 1 MILE UNDERGROUND CIRCUIT MAP (2305E136) SCALE: 6" = 1 MILE CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE ROL-16 6/13/17 205 191 213 -3.36 - 205 194.36 213 9 0 ° 60'150'140'150'PSE PROVIDED 1 - 2" SCH80 PVC CONDUIT IN CUSTOMER TRENCH PSE PROVIDED 2 - 3" DB120 CONDUIT IN CUSTOMER TRENCH 316999-166523 25 kVA 120/240V EXISTING 40T SW #T______ NEW 40T SW #T______ JOB SITE 316999-166523 25 kVA 120/240V EXISTING 40T SW #T______ NEW 40T SW #T______ 397.5KCMIL ACSR 1 - 350KCMIL SEC TPLX NEW 1 - 1/0 AL SOL PRIMARY CABLE #BØ-EHO831 1 - 350KCMIL SEC TPLX PRIMARY & SECONDARY CONDUIT DIAGRAM N Vicinity Map N/A Owner / Developer Contact Info officeATTN: Sapphire Homes, Inc 16834 SE 43rd ST Bellevue, WA 98006 Travis Kassebaum (206) 484-4321 105086971FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV N/A 101109015 N/A 108103767 N/A 593190248 N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Svc/MSA Phone INTOLIGHT Contact Information: N/A N/A E-Mail: Cell Phone: Project Manager Contact Information: Manager:Dave Honeysett (253) 245-0883 DAVID.HONEYSETT@PSE.COM PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: NONE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Dave Honeysett (253) 245-0883 11/27/17 Nate Linville (253) 970-7284 11/27/17 N/A N/A N/A Nate Linville (253) 970-7281 Required City of Renton Cascade Greens 4 Lot Plat 1Ø PRIMARY LE, SET PM TRF, INST 2 - STUBS 11427 SE 162ND ST, RENTON, WA 98055 N/A N/A N/A 105086971 AS NOTED 1 OF 2 KING N/A N/A CSPSKEPM NE-29-23N-05E N/A N/A 2305E113 2305E136 2305E113 ROL-16 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105086971 N/A N/A 505052286 N/A PRIMARY & SECONDARY CABLE DIAGRAM SCALE: NONE MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF10' 10' 10' JOINT TRENCH DETAIL Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. * 2. Rocks greater than 10 inches diameter are not permitted in the final backfill. 3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 Primary & Secondary-Mainline Gas & Communications (NTS) TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONTTRANSFORMER EXCAVATION DETAIL AT V01 SCALE: 6" = 1 MILE MINIMUM CLEARANCES FROM OIL-FILLED EQUIP. TO BLDG. FEATURES NOT TO SCALE FIRE ESCAPE SERVICE GAS RELIEF DOOR, WINDOW, VENT, OR OTHER OPENING TANK FUEL VENT OIL-FILLED ELECTRICAL EQUIPMENT SPRINKLER VALVE, STANDPIPE, OR HYDRANT 20' 3' 10' 6' 10' (TRANSFORMER) PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT PRIMARY CABLE ASBUILT INFORMATION SIZE Qty LENGTH Design (ft) BENDS PULL PULL Cable LENGTH Design (ft) Cable Numbers Please Record Foreman - Complete FROM TO (in)90°45°22°11°(lbs) Rev (lbs)Size A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) P01 V01 1 2 210 2 0 0 0 PRI 12KV 1/0 UG 250 -EHO831 - SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed Lot Corner CONDUIT VOLTAGE DROP VOLTAGE FLICKER ASBUILT INFORMATION SIZE LENGTH Design (ft) SIZE LENGTH Design (ft) BENDS Foreman - Complete FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°(Percent)(Percent)Actual Amount Installed (Conduit & Cable) V01 LOT 3 4/0 UG TPX 160 40 3 140 1 0 0 0 1.6%3.7% V01 LOT 4 350KCMIL UG TPX 170 40 3 150 1 0 0 0 1.5%3.2% CROSSINGS CONDUIT TABLE X-ING NO. LOCATION GAS POWER Length Remarks (type of crossing) SIZE Type Qty Location SIZE Type Qty (Primary, Feeder, Secondary, St. FROM TO (in)sched each N-S-E-W (in)sched each (ft)Light, Gas Only, etc.) X01 P01 V01 2 DB120 2 60 PRIMARY 60'= 2" SCH80 GREY PVC (ft) 0 = 3" DB120 GREY PVC (ft) 0 = Total 2" PVC Plug / Caps 0 = Total 3" PVC Plug / Caps Total Glue = 0.5 Qts Total E 60' COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA