Loading...
HomeMy WebLinkAboutMFP18000348DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP18000348 IVR Number: 18000348 Permit Informa!on Permit Name:Puget Sound Energy - Electric Address/Loca!on:01/18/2018Applica!on Date:8645511040Parcel Number:3209 SE 18TH ST Permit Type :01/29/2018Issue Date:Franchise Permit Work Class:01/29/2019Expira!on Date :Minor U$lity Job Number:105083951Franchise Type :Electric Descrip!on:Install 190' of cable and conduit in the ROW at the intersec$on of SE 18th ST and Monroe Ave SE from J 02 to the plat entrance. Approximately 50' will cross SE 18th ST, then head east 140' to the plat entrance. Pavement cuts an$cipated . Restora$on per City of Renton standards . Contacts Name Address PhoneTypeBilling ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC - BILLING 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: BL.005109Electrical Contractor : POTELI*344O4 Construc!on Contractor : POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC - BILLING 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 105083951 Anish Kumar 253-208-2183 anish.kumar@pse.com 3230 SE 18th St 98058 Allura at Tiffany Park At the intersection of SE 18th St & Monroe Ave SE, approximately 190' of cable & conduit will be installed into ROW from J02 to the plat entrance (see design). Approximately 50' will cross SE 18th St, then head East approximately 140' to the plat entrance. Pavement cuts anticipated. Restoration per City of Renton standards. 190'x3'x5' Potelco Inc.253-208-2183 BL005109 Poteli*227PL 1/18/2018 MFP18000348 Scott Warlick 1/19/2018 Justin Johnson 1-26-2018 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form Allura at Tiffany Park 105083951 PSE/Potelco Inc. Brian Harmon 425-495-5528 6905 S 228th St, Kent, WA 98032 brian.harmon@pse.com 3230 SE 18th St TBD 2/5/2018 Anish Kumar 1/18/2018 MFP18000348 Justin Johnson 1-26-2018 9:00 am to 3:00 pm Monday through Friday SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). S E 1 8 t h S t SE 18th StLake Youngs Way SE Monroe Ave S E Maintain Access in and out of driveways 50'140' UTILITY WORK AHEAD BE PREPARED TO STOP UTILITY WORK AHEAD BE PREPARED TO STOP 100' 100' 100' 100' NOPARKING FROM TO TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T39 NOPARKING FROM TO TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T39 NOPARKING FROM TO TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 R7-T39 NOPARKI N G FROM TO TOW A W A Y A R E A PHONE 685 - 5 4 4 4 YOUR CO M P A N Y N A M E 555-555 5 R7-T3 9 NOPAR K I N G FRO M TO TO W A W A Y A R E A PHON E 6 8 5 - 5 4 4 4 YOU R C O M P A N Y N A M E 55 5 - 5 5 5 5 R7 - T 3 9 NOPAR K I N G FRO M TO TOW A W A Y A R E A PHO N E 6 8 5 - 5 4 4 4 YOU R C O M P A N Y N A M E 555- 5 5 5 5R7- T 3 9 SIDEWALK CLOSED CROSS HERE R9-11a(L) SIDEWALK CLOSED CROSS HERE R9-11a(R) SIDEWALK CLOSED CROSS HERE R9-11a(R) NOT TO SCALE N S EW NOTIFY EMS, FIRE AND POLICE 72 HOURS IN ADVANCE CUSTOMER: CONTACT: LOCATION: DATE:W/O # Designed By: Robert Pratt Off: 503-723-7287 Ext 1013 Cell # 503-539-0548 WATCP@KNDSERVICES.NET WSTCS#010077 ORTCS#05152 PSE Marc Cabanag (253) 395-6825 K&D Services, as the preparer of this traffic control plan makes no representation as to its' general adequacy or being approved for implementation. Approval must result from the Traffic Engineer or other Public Official having statutory enforcement authority in the jurisdiction. Utilization and implementation of this plan shall be a result of that approval. Ref. MUTCD 2009 6A-01 (10) Notes: 1. Maintain ped. access to and through crosswalks 2. Maintain Min. 10' lanes 3. Maintain local access 4. Notify Transit Authority at least 48 hrs. in advance of bus stop closure 5. Traffic control plan and all devices shall comply with MUTCD, PROWAG & WSDOT 6. DEVICE SPACING Flag Taper 20' Signs per WSDOT Tapers per WSDOT 7. 28" Cones 36" Barrels 48" Signs 24" Paddle 8. Adjust to field conditions Switch controls to north side of 18th when trenching Lane Width 10' Posted Speed 25 Flagger Taper 100' Buffer 50' Sign Spacing (X) 100'+/- Devices Taper 20' Devices Tangent 40' Legend Cone Flagger Flagger Ahead NO PARKING FROM TO TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555 No Parking R7-T39 SIDEWALK CLOSED CROSS HERE R9-11a(L) Sidewalk Closed, Cross Here R9-11a(L) SIDEWALK CLOSED CROSS HERE R9-11a(R) Sidewalk Closed, Cross Here R9-11a(R) BE PREPAREDTO STOP W20-7b be prepared to stop UTILITY WORKAHEAD W21-7 utility work ahead Work Area INVENTORY: 2-UTILITY WORK AHEAD 2-BE PREPARED TO STOP 2-FLAGGER AHEAD 2-FLAGGERS 3-SIDEWALK CLOSED CROSS HERE 1(L) 2(R) 6-NO PARKS 25-CONES 3230 SE 18th St Renton WA 01/10/18 105083951 MFP18000348 NVicinity Map47.4639, -122.1749Owner / Developer Contact InfoofficeATTN:MAINVUE WA LLC1110 112TH AVE NE #202BELLEVUE, WA, 98004LUKE THORNTON206.743.2328THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)PSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required"ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.GASPHONECABLE TV504148324105083951504148325107053564106320197PROJECT PHASEPWRNOTIF#ORDER#SuperiorPerm. ServiceRelocationRemovalTemporaryJob OrderDistributionService StubsHP Svc/MSA10.9.8.7.6.5.4.3.2.1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCHPROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITESSUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVESTABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FORVAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4"BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IFREQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FORDISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALLTRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE.ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTHINDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLEDTO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARYCABLES PER THE CIRCUIT ONE-LINE DIAGRAM.UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROADCROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ONWORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PERPUGET SOUND ENERGY STANDARDS.AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES INCONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE &CONDUIT TABLE.AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES INCONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE &CONDUIT TABLE.AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER.ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE.AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3)MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE.(EXCAVATION: 3' SQ.)AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT ASINDICATED ON VAULT TABLE.AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT.AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OFSTANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TOEXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THESTREET LIGHT STANDARDS. )INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMESAND DATES.POWER GENERAL NOTES - PLAT PROJECT105083951107053564DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. HARMON425.495.5528.C. SNYDER.3.2.17C. SNYDER.3.2.17N. HOSSEINI.3.21.17REDT # ( RW-099696 )CITY OF RENTONALLURA AT TIFFANY PARK2Ø PRIMARY U/G LINE EXTENSION - 94 S/F LOTSP# 212305904402 (3229 SE 18TH ST), RENTON, WA 98058PUGET SOUND ENERGYN/AIP 132-60107053564105083951N/A1 OF 6KING32CIKNCQCSOKE21SE-T23-R05E208.080211.0852305E0842305E0882305E084ROL-16CABLE..TELEPHONE..RIGHT OF WAYALEX MALESIS425-462-3436...11.E-Mail:Cell Phone:Project Manager Contact Information:Manager:BRIAN HARMON425.495.5528Brian.Harmon@pse.comxx.........xxLTHORNTON@NOVASTARDEV.COMVAULT DETAIL @ V05NOT TO SCALETOP VIEWSIDEVIEWEXCAVATION:4-2/3 CUBIC YARDSRockCrushed6"3'-6"2"6'6'48"42"36"38"42"StrutsFRONTFRONTTYPICAL NOTCH-OUT FOR TRANSFORMER,NOT TO SCALE& SECONDARY PEDESTAL/HANDHOLEBACK OF EASEMENTSTANDARDEASEMENTLINEROW10'PL1'4' - 5'Min.1'7'7'TRANSFORMER(WHEN PRESENT)42"45°42"1'45°Property LineRoad SideTop View of Mainline Trench forSingle Stubout Location3'Property LineRoad SideTop View of Mainline Trench for Pedestalor Double Stubout Location42"45°3'45°STUBOUT EXCAVATION DIMENSIONSNOT TO SCALEJOINT TRENCH DETAILNOT TO SCALE JOINT TRENCH DETAILNOTES:1. If the final backfill contains rocks greater than 8 inches in diameter, install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller, install 6 inches compacted sand shading across the full width of the trench. *2. Rocks greater than 10 inches diameter are not permitted in the final backfill.3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line.4. Utilities shall not be stacked over the gas line in the trench.5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements.6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies.* Alternatives to full-width trench shading require PSE approval.Primary & Secondary-Mainline Gas & Communications (NTS)ROAD SIDENATIVESECONDARY POWERPEDESTALMATERIALP/LPowerSecondaryPowerPrimaryConduitTel. & TV12" Min12" SandCover whengas line is intrenchSand6" or 12"4" Sand Bedding1'36"Cover42"Gas12"18"Lower2"10"PedestalPSE 10' FRONTAGEEASEMENT1'CoverROAD SIDEMINIPADMINIPADFIELD SIDEVAULT6" of crushed rock(base for vault)P/LPowerSecondaryPowerPrimaryGas12" Min Horizontal SeparationCommunications42" Min21"1'Feeder38"2"4" Sand Bedding12" SandCover36"Cover4" Sand Bedding42"6" Additional depth whenFeeder is requiredPSE 10' FRONTAGE EASEMENT1'TRANSFORMERFinalBackfillInitialBackfillTrench Depth42" - 48"PrimaryDirt PileFinal Grade24" Min36"Min CoverOver Power48"MaxDepthFinal BackfillGas4" Sand BeddingProperty Lineintercept (depth varies).SidewalkCurbLocation of roof drain48" TypicalWidth may vary perNumber of Utilitiesand Conduits6" or 12" Min Sand ShadingOver Gas after Compaction12" MinR/W orExcavated12" TypicalPowerSecondaryPowerTV & TEL12" Min12" MinSeparation4,51,21366" or 12" Min Sand Shading Over Power after Compaction1MINIMUM CLEARANCES FOR PSE EQUIPMENTNOT TO SCALEOIL-FILLED EQUIPMENTTRANSFORMERAPPROVEDAREACOMBUSTIBLE BUILDING WALLS & ROOF10'10'10'COOLING5' MIN5' MIN10' MIN5'MINFINSACCESSCONCRETE PADMINIMUM CLEARANCES FOR PSE EQUIPMENTNOT TO SCALECURB OR EDGE OF PAVEMENTCURB OR EDGE OF PAVEMENT5' MINROAD ORPARKING AREATYP. PAD& TRANS-FORMER3'MIN3' MINDOORACCESSDOORREQUIREDWORK SPACEAREA3' MINCLEAR WORKING SPACE FOR VAULTSNOT TO SCALEFIELD SIDE (PREFERRED)ROAD SIDE (PREFERRED)6' MIN3'MIN3'MIN3' MINCables should enter the vault so that all ofthe cables will lay in the same direction.Top View, 12 kV Cable RoutingSITEVAULT DETAIL @ V01-V04 & V06-V09 NOT TO SCALESTD 6775.0030EXCAVATION: _____ CUBIC YARDS3'-6"SIDE VIEW2"6"CRUSHED ROCKTOP VIEW7'7'6 1/32"Excavation - 19-1/2 cubic yardsSIDE VIEW5'-4"Crushed6"RockTOP VIEW9'11'7'-0"4'-0"1'4'-8"VAULT DETAIL @ J01NOT TO SCALE@ H1A, H1B, H1C, H2A, H2B, H2C, H3A,H3B, H3C, H4A, H4B, H5A, H6A, H6B,H6C, H7A, H7B, H8A, H8B, H8C, H9ASHALL BE STAGGEREDCONNECTOR BARSIN THE FRONTNEUTRALS SHALL BE18"16"13"12"10"2"10"Pedestal will accept up to six 3" conduitsSEALED WITH FOAMCONDUIT SHALL BE120 PVC CONDUIT ELBOWSTYPICAL 24" RADIUS DBSIDE VIEW WITH CONDUIT10"18"16"13"10"2"36"FRONT VIEW WITH CONDUITSECONDARY PEDESTAL DETAIL NOT TO SCALEMFP18000348 124TH PL SE 124TH PL SETRACT LSE 158TH STCEDAR RIVERPIPELINE R/W12370FUT: 1-2"TRACT Q60'53'TRACT MSE 18TH ST124TH P L S E ROAD AMONROE AVE SE ROAD A32093215322132271732DEVELOPER RESPONSIBLEFOR CONDUIT/WIRE FROMH1A TO METER LOCATIONSE 18TH STTRACT O TRACT CTRACT N53 '53'53' 53'1" = 50'DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. HARMON425.495.5528.C. SNYDER.3.2.17C. SNYDER.3.2.17N. HOSSEINI.3.21.17REDT # ( RW-099696 )CITY OF RENTONALLURA AT TIFFANY PARK2Ø PRIMARY U/G LINE EXTENSION - 94 S/F LOTSP# 212305904402 (3229 SE 18TH ST), RENTON, WA 98058PUGET SOUND ENERGYN/AIP 132-601070535641050839511" = 50'2 OF 6KING32CIKNCQCSOKE21SE-T23-R05E208.080211.0852305E0842305E0882305E084ROL-16CABLE..TELEPHONE..RIGHT OF WAYALEX MALESIS425-462-3436...SITE PLANCIRCUIT LOADING TABLEAS OFEXIST. PEAK LOADEST. NEW LOADTOTALCIRCUIT:A PHASE B PHASE C PHASEROL-165.06.16182193183-1922182212205.........SCHED.SQ. FT.MAX LRC = CIRCUIT FEET ADDED: 2955273,000140 AMPSTHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)MATCHLINE (SEE BELOW RIGHT)CCMATCHLINE (SEE ABOVE LEFT)CCM A T C H L I N E ( S E E P A G E 3 ) (SE E P A G E 3 ) MA T C H L I N E AABB FAULT CURRENT TABLE‘3075$16)250(56 9 120V WINDINGS240V WINDINGSLOCATIONSIZER/XMIN.%ZFAULTCURRENTMIN.%ZFAULTCURRENTV01-V04,V06-V0975KVA0.52.3036,200 AMPS1.8023,100 AMPSV0550KVA0.52.3426,700 AMPS1.8017,400 AMPSDeveloper Note:The following Fault Current information MUST BE conveyedto the builder of the units:All units may require upgraded house electrical equipment as thefault current at the meter base may exceed 10,000 amps.DEDICATED FACILITIES (105083951)SITESPANADDITIONALREMARKSLABOR UNITS#FROMTOFOOTAGE-V01Lot 9140Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V01Lot 9240Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-H1BLot 8945Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V02Lot 8640Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-H2ALot 5845Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V03Lot 8040Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V03Lot 7440Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V03Lot 7540Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V04Lot 6355Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V04Lot 6460Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-H4ALot 6160Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V05Lot 4440Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V06Lot 1840Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V07Lot 2345Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V07Lot 2445Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-H7BLot 2645Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V08Lot 3145Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-H8BLot 2945Dedicated Conduit & Cable(Stub Location)2-36, 2-54AH8CLot 3225Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V09Lot 3545Dedicated Conduit & Cable(Stub Location)2-36, 2-54A-V09Lot 4140Dedicated Conduit & Cable(Stub Location)2-36, 2-54ATOTAL FT=920CMFP18000348 SE 18TH STROAD ATRACT GTRACT KROAD AGAS ONLY 53'53'58'53'53'53'TRACT PDESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. HARMON425.495.5528.C. SNYDER.3.2.17C. SNYDER.3.2.17N. HOSSEINI.3.21.17REDT # ( RW-099696 )CITY OF RENTONALLURA AT TIFFANY PARK2Ø PRIMARY U/G LINE EXTENSION - 94 S/F LOTSP# 212305904402 (3229 SE 18TH ST), RENTON, WA 98058PUGET SOUND ENERGYN/AIP 132-60107053564105083951AS SHOWN3 OF 6KING32CIKNCQCSOKE21SE-T23-R05E208.080211.0852305E0842305E0882305E084ROL-16CABLE..TELEPHONE..RIGHT OF WAYALEX MALESIS425-462-3436............THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)1" = 50'SITE PLANMATCHLINE(SEE PAGE 3)(SEE PAGE 3)MATCHLINE AABB FAULT CURRENT TABLE‘3075$16)250(56 9 120V WINDINGS240V WINDINGSLOCATIONSIZER/XMIN.%ZFAULTCURRENTMIN.%ZFAULTCURRENTV01-V04,V06-V0975KVA0.52.3036,200 AMPS1.8023,100 AMPSV0550KVA0.52.3426,700 AMPS1.8017,400 AMPSDeveloper Note:The following Fault Current information MUST BE conveyedto the builder of the units:All units may require upgraded house electrical equipment as thefault current at the meter base may exceed 10,000 amps.CROSSING CONDUIT TABLEX-ING#LOCATIONGASPOWERXINGLENGTHTYPE OF CROSSING(Feeder, Primary, Secondary, etc.)FROMTOSIZE(IN)TYPEQTYLOCATIONSIZE(IN)TYPEQTYX01J02Site "B"ELEC ONLY480150PRIMARYX1ASite "B"Site "C"ELEC ONLY4801140PRIMARYX02PV1Site "D"ELEC ONLY480160X03Lot 94Lot 22401E380260GAS SERVICE & SECONDARIESX04Lot 92Lot 42401E380260GAS SERVICE & SECONDARIESX05Lot 90Lot 62401E380260GAS SERVICE & SECONDARIESX06Lot 88Lot 574401N280360GAS MAIN & PRIMARIES4801X07Lot 88Lot 582401S380160GAS SERVICE & SECONDARYX08Lot 87Lot 592401S380160GAS SERVICE & SECONDARYX09Lot 86Lot 594401S280160GAS MAIN & PRIMARY & SECONDARY3801X10Lot 60Lot 722401N380160GAS SERVICE & SECONDARYX11Lot 62 Lot 702401N380260GAS SERVICE & SECONDARIESX12Lot 64Lot 682401N380260GAS SERVICE & SECONDARIESX13Lot 66Lot 464401-GAS ONLY60GAS MAINX14Lot 81Lot 732401N380260GAS SERVICE & SECONDARIESX15"Tract L"Lot 754401N380260GAS MAIN & SECONDARIESX16Lot 76Lot 772401W380125GAS SERVICE & SECONDARYX17"Tract L"Lot 782401N380160GAS SERVICE & SECONDARYX18"Tract L"Lot 792401N380160GAS SERVICE & SECONDARYX19"Tract L""Site A"ELEC ONLY2801105PRIMARYX20Lot 20Lot 72401N380260GAS SERVICE & SECONDARIESX21Lot 19Lot 92401S380160GAS SERVICE & SECONDARYX22Lot 19Lot 134401S380125GAS MAIN & SECONDARYX23Lot 13Lot 104401W380125GAS MAIN & SECONDARYX24Lot 57Lot 204401W280260GAS MAIN & PRIMARIESX25Lot 23Lot 552401E380260GAS SERVICE & SECONDARIESX26Lot 26Lot 532401W380260GAS SERVICE & SECONDARIESX27Lot 28Lot 512401E380160GAS SERVICE & SECONDARYX28Lot 30Lot 492401W380260GAS SERVICE & SECONDARIESX29Lot 32Lot 472401W380260GAS SERVICE & SECONDARIESX30Lot 34Lot 434401N280160GAS MAIN & PRIMARYX31Lot 35Lot 414401N280160GAS MAIN, PRIMARY & SECONDARIES38022" PVC PLUG /CAPS = 382" YELLOW SCH 40 PVC = 1105 FT2" DB120 GREY PVC = 685 FT2" PVC PLUG /CAPS = 184" PVC PLUG /CAPS = 184" YELLOW SCH 40 PVC = 470 FT3" DB120 GREY PVC = 2115 FT3" PVC PLUG /CAPS = 744" DB120 GREY PVC = 310 FT4" PVC PLUG /CAPS = 4VAULT & EQUIPMENT TABLESITE #GRID #VAULT SIZE &COVERTYPE & SIZEEQUIPMENT INVAULTBUSHINGSTRANSFORMER ID NUMBERS(COMPANY ID)AS-BUILT INFORMATIONLBDCFOREMAN: INCLUDE PHASE TAPPEDV0131720916686554"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 624715011MINU1LR 6045.1010 CØV0231719116688154"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 62471502-MINU1LL 6045.1010 BØV0331715816687454"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 624715011MINU1LL 6045.1010 BØV0431716416691054"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 624715011MINU1LR 6045.1010 BØV0531714416693042"x48"x38"Unistrut HHMatid: 766300150KVA MP TRF120/240Matid: 624710011MINU1SL 6045.1010 CØV0631722716690054"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 624715011MINU1LR 6045.1010 BØV0731719816691254"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 62471502-MINU1SL 6045.1010 CØV0831716616693554"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 62471502-MINU1LL 6045.1010 CØV0931713716695354"x54"x38"Unistrut HHMatid: 766300275KVA MP TRF120/240Matid: 624715011MINU1LR 6045.1010 CØJ013172021668934'8"x7'x5'w/2-3' Sq DoorsMatid: 7663200J-Box Below Gradew/4-Pos J-Bus x3Matid: 762590071JBOX15L 6055.1030 CØ&BØCAP (7630600)PV13172061668654'8"x7'x5'w/2-3' Sq DoorsMatid: 76632003Ø PRIMARYPULL VAULT2-SVTB20 6051.1500SPL10J 6041.2000 BØ & CØJ02317198166823EXISTINGCOMBO VAULTEXISTING2--MFP18000348 DEVELOPER RESPONSIBLEFOR CONDUIT/WIRE FROMH1A TO METER LOCATIONGAS ON L Y FUT: 1-2"GAS ON L Y DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. HARMON425.495.5528.C. SNYDER.3.2.17C. SNYDER.3.2.17N. HOSSEINI.3.21.17REDT # ( RW-099696 )CITY OF RENTONALLURA AT TIFFANY PARK2Ø PRIMARY U/G LINE EXTENSION - 94 S/F LOTSP# 212305904402 (3229 SE 18TH ST), RENTON, WA 98058PUGET SOUND ENERGYN/AIP 132-601070535641050839511" = 50'4 OF 6KING32CIKNCQCSOKE21SE-T23-R05E208.080211.0852305E0842305E0882305E084ROL-16CABLE..TELEPHONE..RIGHT OF WAYALEX MALESIS425-462-3436............THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)MATCHLINE (SEE BELOW RIGHT)AAMATCHLINE (SEE ABOVE R IGHT )BBMATCHLINE (SEE BELOW LEFT )BBMATCHLINE (SEE ABOVE LEFT)AASECONDARY 2"SECONDARY 3"PRIMARY 4"PRIMARY 2"CONDUIT LEGENDNEW CONDUIT DIAGRAMSCALE: NONESECONDARY HH/PEDESTAL TABLESitePedestalorHandholeNumber ofPositionsRequiredRemarksH1APEDESTAL6- SEPL6 6050.1000H1BPEDESTAL5- SEPL6 6050.1000H1CPEDESTAL2- SEPS3 6050.1000 COMMERCIAL SERVICE WO#105XXH2APEDESTAL3- SEPS3 6050.1000H2BPEDESTAL3- SEPS3 6050.1000H2CPEDESTAL3- SEPS3 6050.1000H3APEDESTAL3- SEPS3 6050.1000H3BPEDESTAL3- SEPS3 6050.1000H3CPEDESTAL4- SEPS4 6050.1000H4APEDESTAL5- SEPL6 6050.1000H5APEDESTAL3- SEPS3 6050.1000H6APEDESTAL4- SEPS4 6050.1000H6BPEDESTAL3- SEPS3 6050.1000H6BPEDESTAL5- SEPL6 6050.1000H7APEDESTAL3- SEPS3 6050.1000H7BPEDESTAL5- SEPL6 6050.1000H8APEDESTAL3- SEPS3 6050.1000H8BPEDESTAL5- SEPL6 6050.1000H8CPEDESTAL4- SEPS4 6050.1000H9APEDESTAL3- SEPS3 6050.1000MFP18000348 DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. HARMON425.495.5528.C. SNYDER.3.2.17C. SNYDER.3.2.17N. HOSSEINI.3.21.17REDT # ( RW-099696 )CITY OF RENTONALLURA AT TIFFANY PARK2Ø PRIMARY U/G LINE EXTENSION - 94 S/F LOTSP# 212305904402 (3229 SE 18TH ST), RENTON, WA 98058PUGET SOUND ENERGYN/AIP 132-60107053564105083951AS SHOWN5 OF 6KING32CIKNCQCSOKE21SE-T23-R05E208.080211.0852305E0842305E0882305E084ROL-16CABLE..TELEPHONE..RIGHT OF WAYALEX MALESIS425-462-3436............THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)SECONDARY CABLE & CONDUIT TABLELOCATIONCABLECONDUITVOLTAGEASBUILT INFORMATIONSIZELENGTHASSUMEDSIZELENGTHBENDSDROPFLICKERForeman - CompleteFROMTO(1/O,4/O,350)Design (ft)Lot Corner toMeter (ft)(in)Design (ft)ƒƒƒƒ(Percent)(Percent)Actual Amount InstalledCableConduitV06H6A350105310521.81.8V06H6B35012531252121.71.9V06H6C35019031652132.42.4V06LOT 161/O6550265122.23.5V06LOT 171/O155021511.82.4V06LOT 181/O555025512.23.3V06LOT 191/O605026012.23.4H6ALOT 74/O1105035022.53.6Label Yellow Tag "MUST BE 4/0 TO METER"H6ALOT 84/O1055034522.53.6Label Yellow Tag "MUST BE 4/0 TO METER"H6ALOT 94/O805032022.43.3Label Yellow Tag "MUST BE 4/0 TO METER"H6BLOT 144/O605026012.53.7H6BLOT 151/O5022.23.0H6CLOT 104/O60503352112.93.7Label Yellow Tag "MUST BE 4/0 TO METER"H6CLOT 114/O605026012.93.7Label Yellow Tag "MUST BE 4/0 TO METER"H6CLOT 121/O5022.93.5H6CLOT 131/O5022.93.5V07H7A3501653165211.92.3V07H7B3501153115211.91.9V07LOT 221/O655026512.23.5V07LOT 231/O605026012.23.4V07LOT 241/O605026012.23.4V07LOT 251/O655026512.23.5V07LOT 554/O855032522.03.1V07LOT 564/O905033022.03.1H7ALOT 201/O5022.33.3H7ALOT 211/O5022.33.3H7BLOT 264/O555025512.63.6H7BLOT 274/O605026012.63.7H7BLOT 534/O65503522.63.7H7BLOT 544/O65503522.63.7V08H8A350255319532.32.9V08H8B350110311021.91.8V08H8C3508538521.71.6V08LOT 301/O605026012.23.4V08LOT 311/O555025512.23.3V08LOT 474/O905033022.13.1V08LOT 484/O855032522.03.1H8ALOT 514/O5022.53.5Label Yellow Tag "MUST BE 4/0 TO METER"H8ALOT 524/O5022.53.5Label Yellow Tag "MUST BE 4/0 TO METER"H8BLOT 284/O605026012.63.6H8BLOT 294/O555025512.63.6H8BLOT 494/O855032522.53.4Label Yellow Tag "MUST BE 4/0 TO METER"H8BLOT 504/O805032022.53.3Label Yellow Tag "MUST BE 4/0 TO METER"H8CLOT 321/O255022512.33.3H8CLOT 331/O5022.12.7H8CLOT 344/O605026012.43.4V09H9A35017031702111.52.3V09LOT 351/O555025511.73.3V09LOT 361/O605026011.83.4V09LOT 374/O100503100111.73.2V09LOT 404/O11550355211.83.4V09LOT 414/O11050350221.73.4H9ALOT 381/O5022.03.4H9ALOT 394/O6050260112.03.6Label Yellow Tag "MUST BE 4/0 TO METER"1/O UG Triplex (ft) =13852" PVC & BENDS (ft)=21104033.74/O UG Triplex (ft) =41453" PVC & BENDS (ft)=4195111416313.7350 UG Triplex (ft) =2830TOTAL QTS OF GLUE17.4SECONDARY CABLE & CONDUIT TABLELOCATIONCABLECONDUITVOLTAGEASBUILT INFORMATIONSIZELENGTHASSUMEDSIZELENGTHBENDSDROPFLICKERForeman - CompleteFROMTO(1/O,4/O,350)Design (ft)Lot Corner toMeter (ft)(in)Design (ft)ƒƒƒƒ(Percent)(Percent)Actual Amount InstalledCableConduitV01H1A350115311521.81.9V01H1B350115311521.91.9V01LOT 34/O855032522.13.1V01LOT 44/O805032022.03.0V01LOT 901/O605026012.23.4V01LOT 911/O555025512.23.3V01LOT 921/O555025512.23.3V01LOT 931/O605026012.23.4H1ALOT 14/O805032022.43.4Label Yellow Tag "MUST BE 4/0 TO METER"H1ALOT 24/O755031522.43.3Label Yellow Tag "MUST BE 4/0 TO METER"H1ALOT 941/O5502512.43.1H1BLOT 54/O805032022.53.4Label Yellow Tag "MUST BE 4/0 TO METER"H1BLOT 64/O755031522.73.8H1BLOT 884/O605026012.73.7H1BLOT 894/O555025512.73.6H1AH1C1/O12050312021.71.9COMMERCIAL SERVICE WO#105XXV02H2A350170311031.72.3V02H2B3501603160211.72.2V02H2C3502653145412.23.0V02LOT 594/O1055034521.93.3V02LOT 851/O605026012.03.4V02LOT 861/O555025512.03.3V02LOT 871/O155021511.62.4H2ALOT 571/O5022.23.4H2ALOT 581/O5022.23.4H2BLOT 831/O5022.23.3H2BLOT 841/O5022.23.3H2CLOT 714/O5022.43.6Label Yellow Tag "MUST BE 4/0 TO METER"H2CLOT 724/O5022.43.6Label Yellow Tag "MUST BE 4/0 TO METER"V03H3A350110311021.51.8V03H3B350220316032.02.7V03H3C3507537521.31.6V03LOT 734/O1205036022.03.5V03LOT 744/O1205036022.03.5V03LOT 754/O10550310521.93.3V03LOT 801/O555025512.03.3H3ALOT 811/O5021.92.9H3ALOT 821/O5021.92.9H3BLOT 764/O5022.23.3Label Yellow Tag "MUST BE 4/0 TO METER"H3BLOT 774/O305031022.33.6Label Yellow Tag "MUST BE 4/0 TO METER"H3CLOT 784/O705031022.13.5H3CLOT 794/O1205036022.13.5Label Yellow Tag "MUST BE 4/0 TO METER"V04H4A3501303130211.92.0V04LOT 621/O755027512.23.7V04LOT 631/O705027012.23.6V04LOT 644/O805038011.93.0V04LOT 654/O855038511.93.1V04LOT 664/O15050315012.03.3Label Yellow Tag "MUST BE 4/0 TO METER"V04LOT 674/O955033512.03.2V04LOT 684/O905033021.93.1H4ALOT 604/O755027522.53.5Label Yellow Tag "MUST BE 4/0 TO METER"H4ALOT 614/O705027022.43.4Label Yellow Tag "MUST BE 4/0 TO METER"H4ALOT 694/O1105035022.63.8Label Yellow Tag "MUST BE 4/0 TO METER"H4ALOT 704/O1105035022.63.8Label Yellow Tag "MUST BE 4/0 TO METER"V05H5A3501503150221.72.7V05LOT 444/O555025511.83.3V05LOT 454/O605026011.83.3V05LOT 464/O105503105111.83.3Label Yellow Tag "MUST BE 4/0 TO METER"H5ALOT 424/O5021.93.3Label Yellow Tag "MUST BE 4/0 TO METER"H5ALOT 434/O5021.93.3Label Yellow Tag "MUST BE 4/0 TO METER"H5BLot 601/O6023.33.4MFP18000348 DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. HARMON425.495.5528.C. SNYDER.3.2.17C. SNYDER.3.2.17N. HOSSEINI.3.21.17REDT # ( RW-099696 )CITY OF RENTONALLURA AT TIFFANY PARK2Ø PRIMARY U/G LINE EXTENSION - 94 S/F LOTSP# 212305904402 (3229 SE 18TH ST), RENTON, WA 98058PUGET SOUND ENERGYN/AIP 132-60107053564105083951AS SHOWN6 OF 6KING32CIKNCQCSOKE21SE-T23-R05E208.080211.0852305E0842305E0882305E084ROL-16CABLE..TELEPHONE..RIGHT OF WAYALEX MALESIS425-462-3436............EX OVERHEAD CIRCUIT MAP 2305E088SCALE: 6" = 1 MILEEX UNDERGROUND CIRCUIT MAP 2305E084SCALE: 1" = 100'THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)NEW PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAMSCALE: NONEPRIMARY CABLE & CONDUIT TABLELOCATIONCONDUITCABLEASBUILT INFORMATION - FOREMAN COMPLETEFROMTOSIZE(IN)QTY.DESIGNLENGTH(FT)BENDSPULL(LBS)PULLREV(LBS)CABLESIZEDESIGNLENGTH(FT)PHASE - ID TAGRECORDRECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED90°45°22°11°ABCMANUFACTURERCOMPOUNDYEARNOTESCONDUITCABLEJ02PV141801-2-3725281/0 AL JKT280-EHQ211EHQ212-PV1J01413801---510-EHQ211EHQ212J01V0121220---1119871/0 AL JKT305--EHQ213-J01V02211501---1281021/0 AL JKT235-EHQ214--V02V0321330--1-1641641/0 AL JKT350-EHQ215--V03E01211601-2-CONDUIT ONLY---FUTUREJ01V04215052-2-3472891/0 AL JKT650-EHQ216--J01V0621185--2-121941/0 AL JKT270-EHQ217--J01V07211901-1-1401121/0 AL JKT275--EHQ218-V07V0821390--111741751/0 AL JKT410--EHQ219-V08V05212451---1961961/0 AL JKT325--EHQ220-V05V092126512--1852061/0 AL JKT345--EHQ221-2" PVC (FT) & BENDS =264072921ø AL JKT TOTAL (FT) =31654" PVC (FT) & BENDS =4752-2-2ø AL JKT TOTAL (FT) =790NEW 1/O AL(+4%‘(+4&‘NEW 1/O AL(+4&‘NEW 1/O AL(+4%‘NEW 1/O AL(+4%‘NEW 1/O AL(+4&‘NEW 1/O AL(+4%‘NEW 1/O AL(+4%‘NEW 1/O AL(+4&‘NEW 1/O AL(+4&‘NEW 1/O AL(+4&‘CØ20715BØ20713AØ20712BØ20734AØ20714SITESITEMFP18000348