Loading...
HomeMy WebLinkAboutP_Design_101108351_V1_180123PAN 61'PARCEL# 3223059258 63' 62' 17811 15 (SOFT SHOULDER) (SOFT SHOULDER) REBUILD DEMO/ SE 178TH PL #4ACSR 37.5kVA 120/240v SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: MARIE BROWN 17811 116TH AVE SE RENTON, WA 98058 TOM BUSH 206.799.2819 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. STANDARD EASEMENT PROVISION An easement is hereby reserved for and conveyed to Puget Sound Energy, Inc., Telephone Co., Television Cable Co., and their respective successors and assigns under and upon the private street(s), if any, and the exterior ten (10) feet of all lots, tracts and spaces with in the plat lying parallel with and adjoining all street(s) in which to construct, operate, maintain, repair, replace and enlarge underground or ground-mounted appurtenances thereto for the purpose of serving this subdivision and other property with electric, gas, telephone and other utility service, together with the right to enter upon the streets, lots, tracts and spaces at all times for the purposes herein stated.101108351FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV N/A 108103292 PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service E-Mail: Cell Phone: Project Manager Contact Information: Manager:RUSSELL PAGE (253) 234-6444 RUSSELL.PAGE@PSE.COM PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" SCALE: 1" = 50' THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP R. PAGE (253) 234-6444 10.4.17 R. PAGE (253) 234-6444 10.4.17 E. HAUSER (714) 893-2405 10.4.17 N/A RENTON BROWN 200A OH PERM SVC 17811 116TH AVE SE, RENTON, WA 98058 N/A N/A N/A 101108351 AS NOTED 1 OF 1 KING N/A N/A CSPSKEIN 32NE-T23N-R05E N/A N/A 2305E125 2305E136 2305E125 PAN-15 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 101108351504895993 1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. 2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. 3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 4.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. 5.SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. 6.Roads shall be paved or have a compacted , crushed rock base in place. 7.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. 8.All work is to be done in accordance with local municipal and county permit requirements as applicable. 9.Inclement weather conditions may cause delays in construction times and dates. 10.EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. POWER GENERAL NOTES - RESIDENTIAL PROJECT CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE PAN-15 06/2017 231.00 208.00 170.00 0.00 1.90 0.00 231.00 209.90 170.00 OVERHEAD CIRCUIT MAP 2305E136 SCALE: 6" = 1 MILE JOB SITE JOB SITE ASPLUNDH CONSTRUCTION CORP. SPAN SPECIFIC NOTES P02 TO M01: -REMOVE SERVICE OH TPX TO "17811" P01 TO M01: -INSTALL 1-RUN 4/0 OH TPX ± 120' SITE SPECIFIC NOTES P01: 316457-166562 -EXISTING POLE AND TRANSFORMER TO REMAIN P02: 316439-166562 -EXISTING POLE TO REMAIN M01: NEW METER BASE -INSTALL 200A METER CIRCUIT FEET ADDED: 0' 64)227$*(64)7 3$1(/6,=($ +($77<3((/(&75,& (67'(0$1'.: /5&$ 9'523 )/,&.(5116TH AVE SEOVERHEAD SERVICE TO GUYED RISER SCALE: NONE