Loading...
HomeMy WebLinkAboutP_Design_105081331_V1_180226HIG15ABERDEEN AVE NE 50'65'215'LOT 1LOT 2LOT 3LOT 4ROW 60'6X6 WORK PIT4X4 WORK PIT6&+ /&21'8,7“ 6&+ /&21'8,7“ 5812)8*73;“  5812)$/-.735,“ 6&+ /&21'8,7“ 215'SITE PLANNVicinity MapN/AOwner / Developer Contact InfoofficeATTN:2525 ABERDEEN, LLC728 3RD ST UNIT DMUKILTEO, WA 98275BILL HEGGER (206)679-5131THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGFor contacts below dial 1-888-CALL PSE (225-5773)105081331FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.GASPHONECABLE TV503202931105081331N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/APROJECT PHASEPWRNOTIF#ORDER#SuperiorPerm. ServiceRelocationRemovalTemporaryJob OrderDistributionHP MainHP Svc/MSAARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.CIRCUIT LOADING TABLEAS OFEXIST. PEAK LOADEST. NEW LOADTOTALCIRCUIT:A PHASE B PHASE C PHASEHIG-152015230148143--1.32230148144.32PhoneINTOLIGHT Contact Information:N/AN/ASCHED.SQ. FT.MAX LRC = CIRCUIT FEET ADDED: 215'PLAT4000140 AMPSDESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPBRAD ELKIN425-495-648905/05/16BRAD ELKIN425-495-648905/05/16N/AN/AN/AJ. REIBMANN/A05/05/16EASMENT REQUIREDCITY OF RENTON2525 ABERDEEN AVE NE3 LOT SHOT PLAT2525 ABERDEEN AVE NE, RENTON WA 98056PSEPSEN/AN/A105081331AS NOTED1/1KINGN/AN/ACSPSKEINT23N, R05E, NE SEC 05N/AN/A2305E0172305E0402305E017HIG-15N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A10.9.8.7.6.5.4.3.2.1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCHPROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITESSUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVESTABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FORVAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4"BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IFREQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FORDISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALLTRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE.ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTHINDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLEDTO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARYCABLES PER THE CIRCUIT ONE-LINE DIAGRAM.UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROADCROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ONWORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PERPUGET SOUND ENERGY STANDARDS.AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES INCONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE &CONDUIT TABLE.AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES INCONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE &CONDUIT TABLE.AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER.ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE.AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3)MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE.(EXCAVATION: 3' SQ.)AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT ASINDICATED ON VAULT TABLE.AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT.AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OFSTANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TOEXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THESTREET LIGHT STANDARDS. )INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMESAND DATES.POWER GENERAL NOTES - PLAT PROJECT11.E-Mail:Cell Phone:Project Manager Contact Information:Manager:BRAD ELKIN425-495-6489brad.elkin@pse.comPSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required"SCALE: 1"=50'SCALE: 6" = 1 MILEOVERHEAD CIRCUIT MAPTV & TELElectric Service Cable in Conduit3" Schedule 40 Grey PVCExcavated Dirt PileFinal Grade24" Min24" Minto36" MaxCoverBackfill for ConduitFree of rockslarger than 8"in diameterSeparation12" Minin ConduitSchedule 40 White PVCGas Service Line32" Typical(Power, Gas,Phone & Cable)Separation12" Min12" MinSeparation36" MINIMUM COVERIN RIGHT OF WAY JOINT TRENCH DETAILJoint Service Line in Conduit (NTS)To Excavated Dirt PileBackfill for In Conduit - The backfill layer shall be soil that is free from construction debris,glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.TOP VIEWSIDE VIEWEXCAVATION: 4-2/3 CUBIC YARDSRockCrushed6"3'-6"2"6'6'48"42"36"38"42"StrutsVAULT & EXCAVATION DETAILNot to scale6045.10001950 lbs32"Typical24"Min24"-36"24"-36"4'Top ViewElectric & Joint UtilityWork Pit Dimensions36"MinDrainage Pipe12" Minimum Clearancefrom Gas Service LinesConduit Depth24" to 36" MaxRegulator VentGas Meter AssemblyUtility Provided48"4'8"Service (Permanent Detail:)Not to ScaleSealConduitEndsClosed4'8"24" Min36" Typical3'To TrenchProperty LineConduit StakesCustomer Provided3" Schedule 40 Grey PVCPower Cable ConduitCustomer ProvidedGas Service Line ConduitSch 40 White PVCCustomer Provided3" Conduit Service RiserCustomer ProvidedElec. Mtr BaseElec Mtrutility providedGas MeterRelief VentBuilding WallElec. MtrSCALE: NONEMETER DETAIL @ M01, M02, M03, & M04Standoff Bracket15" Min LengthConduit ClampConduitField FaceQuadrantClimbingSpaceRoad FaceQuadrantClimbingSpace5" MinCLLCDirection of Vehicular TrafficCONDUIT RISER PLACEMENT DETAILTOP VIEWNot to ScaleInstalled at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER INSTALLATIONCompany ID#:Primary phase connected to:Tested Secondary VoltageV01319093-16646137.5kVAP01-EXISTING POLE AND EQUIPMENT TO REMAIN-INSTALL 1/0 AL SINGLE-PHASE TERM ON EPOXY ARM-INSTALL L/B C/O & SURGE ARRESTER, FUSE @ 15T-INSTALL SW# T77036-INSTALL STIRRUP TAP C PHASE-INSTALL 2" PRIMARY RISER ON NEW S/O BRKTSV01-INSTALL MP HH & GNDS-INSTALL 37.5kVA PM TRF 120/240v-INSTALL (1) L/B ELBOW & (1) DUST CAP-INSTALL GRID #319083-166461-INSTALL 3-6 POS CONNECTOR BARS**PULL CALCS = FWD PULL = 279.5LBS / REV PULL = 365.4LBS**SPAN NOTESP01 TO V01P01 TO V01,167$//“ 2)$/-.78*35,0$5<&$%/( (+&&‘ &86720(572,167$//  6&+ /39&&21'8,7“ V01 TO LOT1&86720(5,167$//6&+ /39&&21'8,7“ -INSTALL ELECTRONIC MARKERP01 TO LOT4,167$//6&+ /39&&21'8,7“ -INSTALL 1 RUN OF 4/0 UG TPX, 65'DEVELOPER CIVIL CONTRACTOR NOTES:-REQUIRED TO PROVIDE A 4' X 4' PIT AT EXISTING POLE (P01).-REQUIRED TO PROVIDE A 6' X 6' PIT AT TRANSFORMER VAULT (V01).-REQUIRED TO PROVIDE AND HAVE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCHES AT ALL TIMES.-CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATIONPER PUGET SOUND ENERGY STANDARDS# 6750.6500.**DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL **PSE PROVIDES CONDUITS:3729“ 2)  ´ CONDUIT SCH'L 80.972/27“ 2)  ´ CONDUIT w/ STUB.972/27“ 2)  ´ CONDUIT w/ STUB.-PSE TO PROVIDE 3/8 NON-POLY WHITE PULL ROPE OR MULE TAPE IN ALL CONDUITS.DEVELOPER SERVICE CONNECTION NOTE:***WHEN READY FOR SECONDARY SERVICE CONNECTIONS AT THE INDIVIDUAL HOUSES, PLEASE CONTACT PSE AT1-888-CALL-PSE. FEED COMES FROM P01 GRID #319090-166482 AT NEW TRANSFORMER V01 GRID #319083-166461SITE SPECIFIC NOTESSCALE: NONECONDUIT DIAGRAMJOB SITEPRIMARY CABLE & CONDUIT TABLELOCATIONCONDUITPRIMARY CABLEASBUILT INFORMATIONSIZEQtyLENGTHDesign(ft)BENDSPULLPULLCableLENGTHDesign(ft)Cable NumbersPlease RecordForeman - CompleteFROMTO(in)ƒƒƒƒ(lbs)Rev(lbs)SizeABCManufacturerCompoundYearActual Amount Installed (Conduit & Cable)P01V012121541/0255EHC164OUTAGE LIST2525 ABERDEEN AVE NE, RENTON WA 980562025 NE 27TH ST, RENTON WA 98056CommunicationsPrimary PowerCables or ConduitExcavated Dirt PileROADSIDEFinal Grade24" Min4" MinSeparation36"MinCover48"MaxBackfill(No rocks over 10" diameter)Separation12" MinGas4" Sand Bedding32" Typical(Power, Gas, andCommunications)JOINT TRENCH DETAILPrimary-Mainline Gas & Communications (NTS)Separation12" Min6" or 12" Min Sand Shading after Compaction- A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter.Trench and backfill requirements for primary electric line extension trenches (No PSE gas)- A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter.