HomeMy WebLinkAboutP_Original_Permit_MFP16003421_V1_180226DEPARTfT,IERT OF •
FranchiseAND ECONOMIC DEVELOPMENT --------,w�Renton 0
•
003421
IVR Number: 16003421
Permit Name:
PSE - Electric
Address
Phone
Address/Location:
2525 ABERDEEN AVE NE
Parcel Number: 3343902000 Application Date:
06/22/2016
Permit Type:
Franchise
Issue Date:
06/22/2016
Permit Work Class:
Minor Utility
Expiration Date:
06/22/2017
Franchise Type:
Electric
Job Number: 105081331 Est. Completion:
06/29/2016
Description:
Install riser on pole in ROW, bore under Aberdeen with SCH 80' pvc and pull wire to new transformer set on private
Billing Type
Name
Address
Phone
X Contact
Carli Bunkelman
6905 S 228th St
B: (253) 437-6708
PSE/POTELCO - Billing
Kent, WA 98032
Contractor
VICKI HENSON
8001 212th St S
B: (253) 863-0484
POTELCO INC
Kent, WA 98032
Electrical Contractor: POTELI*34404
Business License Number:
BL.005109
Construction Contractor: POTELI*227PL
Owner
Hannah Miller
City of Renton
• Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved
plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
• This permit and plans must be posted at the job site at all times.
• 1 hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton
Trench Restoration and Street Overlay Requirements .
• Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in
the Right of Way.
• Call 8 11 to locate underground utilities at least two full business days prior to any excavation .
• In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline
company prior to performing any construction or excavation activities . This requirement to consult with the transmission pipeline
company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Signature) (Date)
THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Page 1 of 2
RVIA311 KK ZW/rKAfVLHISE U F ILI FY MKIM F APPLILoA 14UP4
Phone: (425) 430-7266 Fax: (425) 430-7231 franchise!2rentonwa.gov
T® THE APPLICANT: 'Submit 3 copies 6 of plans with application. Perrrfit cosi 'is $350:50. inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
CITY PERMIT NO: MFP �` � -�
Date of Application:
5/20/16
Franchise Agency: Puget Sound Energy
Mailing Address for Permit: 6905 S 228th St, Kent, WA
Contact Name::Cr1i Bunlcelman
Job Number: 105081331
Job Site Address: 2525 Aberdeen Ave NE
zip: 98032
Phone: 25.3-437=67(38
e-mail; Carli.Bunkelman@pse.com
Project Name: 3 Lot Short Plat
Description of Worlc: Install riser on pole in ROW, bore under Aberdeen with SCH 80' pvc and
pull wire to new transformer set on pvt prop. Please see attached design.
New Construction ❑Repair/Relocate
❑ Open trench R Bore El# of feet:
Estimated Job completion date: 6/29/16
Contractor name: Potelco Inc.
City of Renton Business License Number: B
❑ Sidewalk ❑Street
Phone: 253'43"7-6708
L005�'0� State Contractors License Number: Poteli*227PL
"! certify that. I amthe ap�applicant'st's owner or authorized agent. and dohereby agree• to al�Fde to. the. terrors and.
conditions s
�" "'
et: forth
under this permit and shall comply with the City of Renton's Trench Restoration and Street Overlay Requirements. "
�''�`
Manta G. Bond �
q
Signature � Date 5/20/16
CITY INSPECTOR SHALL BE NOTIFIED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK
BY CALLING THE INSPECTION LJNE AT 425-430-i203
Jobs are required to be called in for job start, re -inspection and project final.
pment Services
lity Inspector
Public Works Permit Supervisor
2/13
Date
Date
Date
Approved as Submitted
❑ On -Site Pre -Con Required
❑ Approved with Comments or Redlines
Traffic Control Plan Attached
❑ Camera Inspect1vwc UUtiiitieN$ Required
RECEIVED
Issue Date:
Permit expires 6 months from issue date
SERVICES
WORK
ORDER NO.:
87029
Franchise Agency: Puget Sound Energy
Mailing Address for Permit: 6905 S 228th St, Kent, WA
Contact Name::Cr1i Bunlcelman
Job Number: 105081331
Job Site Address: 2525 Aberdeen Ave NE
zip: 98032
Phone: 25.3-437=67(38
e-mail; Carli.Bunkelman@pse.com
Project Name: 3 Lot Short Plat
Description of Worlc: Install riser on pole in ROW, bore under Aberdeen with SCH 80' pvc and
pull wire to new transformer set on pvt prop. Please see attached design.
New Construction ❑Repair/Relocate
❑ Open trench R Bore El# of feet:
Estimated Job completion date: 6/29/16
Contractor name: Potelco Inc.
City of Renton Business License Number: B
❑ Sidewalk ❑Street
Phone: 253'43"7-6708
L005�'0� State Contractors License Number: Poteli*227PL
"! certify that. I amthe ap�applicant'st's owner or authorized agent. and dohereby agree• to al�Fde to. the. terrors and.
conditions s
�" "'
et: forth
under this permit and shall comply with the City of Renton's Trench Restoration and Street Overlay Requirements. "
�''�`
Manta G. Bond �
q
Signature � Date 5/20/16
CITY INSPECTOR SHALL BE NOTIFIED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK
BY CALLING THE INSPECTION LJNE AT 425-430-i203
Jobs are required to be called in for job start, re -inspection and project final.
pment Services
lity Inspector
Public Works Permit Supervisor
2/13
Date
Date
Date
Approved as Submitted
❑ On -Site Pre -Con Required
❑ Approved with Comments or Redlines
Traffic Control Plan Attached
❑ Camera Inspect1vwc UUtiiitieN$ Required
RECEIVED
Issue Date:
Permit expires 6 months from issue date
SERVICES
CITY OF RENTON
TRAFFIC CONTROL PLAN
ll'[CJSJ1 C)
PROJECT NAME: 105081331- 2525 Aberdeen Ave NE PERMIT#
CONSTRUCTION COMPANY: PSE/Potelco Inc. PHONE#.
CONTACT NAME: Carle Bunkelman PHONE#: 253-437-6708
ADDRESS: 6905 S 228th St, Kent, WA 98032CELL#:
E-MAILADDRESS: Carll.Bunkelman@pse.com FAX#:
PROJECT LOCATION: 2525 Aberdeen Ave NE N/E/S/W OF:
WORKTIME: TBD APPROVED BY:
WORK DATE: TBSAPPROVAL DATE: -6;L4 �2aj
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain,City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney's fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder's agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City's reasonable attorney's fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: Marita Bond DATE: 6/13/16
Manta G. Bond IXgitally signed by Madta G. Bond
DN: cn=Marita G. Bond, o=Puget Sound Energy, ou=Pertrdnifg,
SIGNATURE: emal1�nadla.bond@pse.com, a=U
S
Dale: 2016.06.13 14:16:26-07'00'
OFFICE COPY
T -
CONTRACTOR
DEV. SERVICE, INSPECTION
P. MILLER
,SERVICE, PLAN REVIEW
B. BANNWARTH
POLICE
CHARLES KARLEWICZ
FIRE
FIRE MARSHALL FS #13
NOTES;
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City's PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-2044455) or any public/private agency to be affected
bY a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow -away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City's maintenance shop
(3555 NE 2nd Street).
SKETCH
-- NORTH --
N
0
C
N
O
V01
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Gadke
Card No. 007599
Card Exp.5/31/2017
stephen.gadke@pse.com
(4�2q5-) 424-64331(�Q� �' n
Naonn
NE 27TH ST
CHANNELIZATION
DEVICE SPACING
MPH
TAPER
TANGENT
55/70
40
80
35/45
30
60
25/30
20
40
Naonn
NE 27TH ST
A®
P01
� I
, k JAY
P t 5 r e kj I
`� Jobi�105081331
2525 Aberdeen AV NE Renton, WA
May 12, 2016
Sheet 1 of 2 stephen.gadke@pse.com
(425) 424-6431
I�lOfeS:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3 Channeiizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
b. Crew is required to leave a minimum of 11' for
traveling lane width,
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
LEGEND
i�
A®
P01
� I
, k JAY
P t 5 r e kj I
`� Jobi�105081331
2525 Aberdeen AV NE Renton, WA
May 12, 2016
Sheet 1 of 2 stephen.gadke@pse.com
(425) 424-6431
I�lOfeS:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3 Channeiizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
b. Crew is required to leave a minimum of 11' for
traveling lane width,
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
LEGEND
V01
Puget Sound Energy
Traffic Control Supervisor:
Stephen R Ga
Card No, 007599
Card Exp.5/31/2017
stephen.gadke@pse.com
( 424Qn 6431
NE 27TH ST
P01
1.:
Job#105081331
2525 Aberdeen AV NE Renton, WA
May 12, 2016
Sheet 2 of 2 stephen.gadke@pse.com
(425) 424-6431
Notes:
f. Alf'signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Sign size can be a minimum of 48" x 48 and
shall not obstruct pedestrian access.
5_ Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
CHANNELItATION
DEVICE SPACING
MPH
TAPER
TANGENT
55/70
40
80
35/45
30
60
25/30
20
40
NE 27TH ST
P01
1.:
Job#105081331
2525 Aberdeen AV NE Renton, WA
May 12, 2016
Sheet 2 of 2 stephen.gadke@pse.com
(425) 424-6431
Notes:
f. Alf'signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Sign size can be a minimum of 48" x 48 and
shall not obstruct pedestrian access.
5_ Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
LEGEND
VE LANE
p
ROAD
CV
MEAD
LEGEND
CP
-a
W
z
Lv
Q
Z
UJ
W
0
W
W
M
L0
,N
L /
N
r7
N
0
N
r0
0
L0
W
Z
Ld
EC
Z
w
0
LIJ
m
Q
�0
N
L0
N
.-
V)
rn
N
0
0
L0
CD
0
N
0
Z
.0
Lw
a
m
E
4-
M
t0
o
N
Mw
W
a
M
1 a
t
319: '66460 ,
I• I
37,5 24 ? . I
Y
` t
.
:
...........-11 11.,.,.V..........................:.........................�.,,...,.,..........
•
v 1111.....,>w 1111.
I.
w _ _........:.:....... a,_,.................. �� ����
a w ................... w ...................
,1111
€1111
r ��
_ 1111,......................�......................_ �...................... r� ...................... „f l
�� ��T� tt
:.:�
. .
. ,
. ,
CIR UIT FEET ADDED: 215 :
t,
SCHED•PLAT 4000 SQ. FT. =•
\.�
; 355
MAX LRC = 140 AMPS
♦1111 >' .24
�; ^zf .
.',a~: / I
�
OW 60' --
SITE SPECIFIC NOTES
P01
-EXISTING POLE AND EQUIPMENT TO REMAIN
-INSTALL 1/0 AL SINGLE-PHASE TERM ON EPDXY ARM
-INSTALL UB C/O & SURGE ARRESTER, FUSE @ 15T
-INSTALL SW# T77036
-INSTALL STIRRUP TAP C PHASE
-INSTALL 2" PRIMARY RISER ORI NEW S/O BRKTS
V01
-INSTALL MP HH & GNDS
-INSTALL 37.5kVA PM TRF 120/240v
-INSTALL (1) UB ELBOW & (1) DUST CAP
-INSTALL GRID #319083-166461
-INSTALL 3-6 POS CONNECTOR BARS
"PULL CALCS = FWD PULL = 2 r'9.5LBS / REV PULL = 365.4LBS**
OUTAGE LIST
2525 ABERDEEN AVE NE, RENTON WA 98056
2025 NE 27TH ST, RENTON WA 98056
P01 TO V01
-
-INSTALL t 255' OF 1/0 AL JKT LI PRIMARY CABLE, (EHC164-CO)
• w_�.................
..................
.
" 1
1
........�..�........�...................... ............ A 2 . CH L 80 PVC CONDUI
^........,,�,..................................... w.
INSTALL
. 1111.....
...................11,11
F
319083 Pa 1 319090 12C� 24�v
37.5kVA V01 f V01 TO LOT1
166461 215 166482
..rte" #T7 �3 -CUSTOMER I NSTALL 1-3" SCH't. 80 PVC CONDUIT, t 65'
22 1224ov •
....................................................I.....................................................,„„„„,,,,,,, 1111.... L........................ I................. 1111 : • •
• 1111....«.,,,,,„„,.,
.,'.11
50....................65.....................................�
•.,..•......................................................................................:
. -INSTALL ELECTRONIC MARKEF;
I E =_Y
P j 1
.
-,.
......�..V..,.........
W : :
: i ..............................,,......... ........ ...........................
11 11.....,,,,« ....................,,,...
01 TOL 4
i '
z -INSTALL 1-3" SCH'L 80 PVC CONDUIT, t 62'
W ,
-INSTALL 1 RUN OF 4/0 UG TPX 65'
>
t :
: Q DEVELOPER CIVIL CONTRACTOR NO TES:
. Z
-REQUIRED TO PRO VIDE A 4' X 4' PI T A T EXISTING POLE (' j.
,.
f- X` LOT 4 LOT 3 LOT 2 LOT 1 W ,
., HIG i -REQUIRED TO PRO VIDE A 6 X 6 PIT A T TRANSFORMER VAULT V01 .
W : j
15 :
_............................................................................................................... �w ,...................................................................................... Q -REQUIRED TO PROVIDE AND hAVE E UIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCHES ATALL TIMES.
Q
i -CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION &RESTORATION
t �' W
:
:. , PER PUGET SOUND ENERGY S rANDARDS# 6750.6500.
z...........
;- �°
0 025354 ; ** tat
DE VEL OPER NEEDS TO FOLLOW ALL TRENCH DE TAILS ON SELECT BACKFILL
a
�� _ .................� 1111.
• 1111....
:,1111,. : 73 ��
--r......................... ...,,.,.,.,.,:,.., ..................
: {.
....- .......................... .1111... •. •.......� 11:11.:
:
1111
r
5{ ........... .......... 4 ......................
f.......... ,`rta i
E a
#
11........11 <
1111..,.,�,�........................, .......,............................................,...�...
M ...........; .............................. _ _ ............. i.......... ra
w _..............................................
.
: >rra >.aA SL,
...I ........... ..
....
.....,. ,
:
g
w,�, ;1111..
1111,,
,...
:p.. ,,; i
{ :v : '''•✓,, as
';;. ,•: ;
•'� ? i .
��
'...✓. . : .: .;dn 1111,
..11.11
��� �� 2
. F.... ...........
3 �..
.
..................., .,_...............11..11 2kV 1224
,1111.�...,,,:..,......................,,,�..,,,....................:.................. w w ...................,� ,_,1111.. .
.................,,,,,.,.......................................x,...,'„:,.,,,.,.,,...........
;
W
I I F
L.; LJ
i
. .
SITE PLAN
SCALE: 1 "=50'
Trench and backfill requirements for primary electric line extension trenches (No PSE gas}
A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter.
- A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter.
Excavated Dirt Pile
11
ROADSIDE 32 Typical \��\\\\r
Power Gas and 24" Min '�/\°' �'�'''�`'\'�'\
( °°\�,`\\/ \fir' \�
I s
unlcat on
o m \
FI
na Grade
Cm 1111.\
\1111..
}
1111... ,�\,�\ ,�\ 1111 , .'�\,�\
11
48
Max
\
\
Backfill
� 11 •
\ r
oc s over 10 diamete
Nor k
\ ``.
\/ nd in after Com action
6 or
12 Min Sa Shad
9
p
L
P
rima Power
Gas
ry
ables o Conduit
C r
Com
munlcations
T REN H
DETAIL
JO
IN T C
Primary -Mainline Gas & Communications (NTS}
Bac�ll for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8 " in diameter.
Excavated Dirt Pile
32 Typical °':: \N\ ,"...�\\\
Power, Gas, 11 :/� // //....; s /f�,
• To Excavated Dirt Plle .moi' - - - F ' %"
Final Grade Phone &Cable} �� /_ XIX \ \/
F ::\ �/,
A " 11 .r
• 12 Min 12 Min \:::'�
24" Min /
to :`�1:`�. Separation Separation �f( ;N. Backfill for Conduit
6" Max . \ t / Free of rocks
3� F -'i 11
Cover � \//\ larger than 8
:- `-• 12" Min \'� In diameter
.: Separation
. - �'/ 36" MINIMUM COVER
\. \
\,:; F Q ,/ \,'r I N RIGHT OF WAY
\ P /\ , F \ ., / / '
Gas Service Line TV & TEL Electric Service Cable in Conduit
in Conduit 3" Schedule 40 Grey PVC
Schedule 40 White PVC
JOINT TRENCH DETAIL
Joint Service Line in Conduit (NTS}
PSE PRO VIDES CONDUITS:
-PO 1 TO V01: t 215' OF 2" CONDUIT SCH'L 80.
-VO 1 TO LOT 1: f65' OF 1 3" CONDUIT w/ STUB.
-V01 TO LOT 4: t65' OF 1 3" CONDUIT w/ STUB.
-PSE TO PROVIDE 3/8 NON-POL Y WHITE PULL ROPE OR MULE TAPE IN ALL CONDUITS.
DE VEL OPER SERVICE CONNECTION NOTE:
"WHEN READY FOR SECONDARY SERVICE CONNECTIONS AT THE INDIVIDUAL HOUSES, PLEASE CONTACT PSE AT
1 -888 -CALL -PSE. FEED COMES FROM P01 GRID #319090-166482 AT NEW TRANSFORMER V01 GRID #319083-166461
Conduit
Standoff Bracket
Climbing 15" Min Length
Space Conduit Clamp
Field Face 5" Min
Quadrant
__ ---�
Road Face
Quadrant
Climbing
Space
Direction of Vehicular Traffic
TOP VIEW
CONDUIT RISER PLACEMENT DETAIL
Not to Scale
PRIMARY CABLE &CONDUIT TABLE
CIRCUIT: HIG-15
AS OF 2015
4X4 WORK PIT
1-3" SCH'L 80 CONDUIT, t 65'
V01 � RUN OF 4/0 UG TPX, t 65'
---- 215'--------� P01
(1) RUN OF 1/0 AL JKT PRI, t 255'
6X6 WORK PIT 1-2" SCH'L 80 CONDUIT, t 215'
1-3" SCH'L 80 CONDUIT, t 65'
CONDUIT DIAGRAM
SCALE: NONE
1950 Ib
42" _` i- 4811
Zvi
CIRCUIT LOADING TABLE
6'
# 'M-,�• f
. ,� r `:
..'' ,{d ;
✓� / ;� - >
@ f'
1111. yv LL s"; J`r,
///; \£
/': � .
' .. '� "
yr
TOP VIEW 211
\•� �/'< /��<
6 11
'� Crushed 3'-6"
'`•: Rock
��1 _ f. 1
�'/�\'/�\'/-,-.:..''Z.\'/�\'/�\:.:•'":