HomeMy WebLinkAboutP_Design_105085461_V2_180426LANE LANE 2 543 STORM TRACT 14 13 12 11 10 1 76 9 8 SE 139TH PL 156TH AVE SE154TH AVE SE336.4 MCMACSRABC ABC336.4 MCMACSRFUSE @ 100T SW#T79976 DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM H2B TO METER LOCATION #2 ACSR ST LT 53' 53'FEED60' N Vicinity Map 47.4780, -122.1333 Owner / Developer Contact Info officeATTN: SSHI LLC DBA D.R. HORTON 12910 TOTEM LAKE BLVD NE KIRKLAND, WA., 98034 PATRICK DANNER 425-821-3400 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 504719088 105085461 N/A 105087299 N/A N/A N/A N/A N/A N/A N/A N/A N/A 107054471 N/A 106326123 N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Comm. H.H. Relocation Removal Temporary Job Order Distribution Service Stubs HP Svc/MSA 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4" BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE. ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY CABLES PER THE CIRCUIT ONE-LINE DIAGRAM. UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER PUGET SOUND ENERGY STANDARDS. AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3) MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE. (EXCAVATION: 3' SQ.) AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT. AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE STREET LIGHT STANDARDS. ) INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES AND DATES. POWER GENERAL NOTES - PLAT PROJECT 105085461107054471DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP LEE BROWN 425-417-8620 3/2/18 J.SINGLETON 253-395-6967 3/2/18 J.SINGLETON 253-395-6967 3/2/18 D.KANOWSKY .7/10/17 REDT # ( RW-101556 )RENTON MEADOW VUE 1Ø PRIMARY U/G LINE EXTENSION - 14 S/F LOTS 13833 156th AVE SE, RENTON, WA 98059 PUGET SOUND ENERGY N/A IP 088-60 107054471 105085461 1" = 50'1 OF 1 KING 30 CIKNC QCSOKE 14SW-T23-R05E 208.086 209.088 2305E055 2306E076 2306E055 MAP-13 COMCAST BILL WALKER 253-288-7538 CENTURY LINK AMY ALLISTON 206-794-8534 RIGHT OF WAY VAL CONNEL 425-462-3518 . . . 11. E-Mail: Cell Phone: Project Manager Contact Information: Manager:LEE BROWN 425-417-8620 lee.brown@pse.com x x x x ... ... ... x x EMAIL CONTACT 1" = 50' SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 589' 27 3600 140AMPS SITE PLAN CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE MAP-13 6/17/17 49 8 32 -9 - 49 17 32 VAULT DETAIL @ V01 NOT TO SCALE TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONTTYPICAL NOTCH-OUT FOR TRANSFORMER, NOT TO SCALE & SECONDARY PEDESTAL/HANDHOLE BACK OF EASEMENT STANDARD EASEMENT LINE ROW 10' PL 1' 4' - 5' Min. 1' 7'7' TRANSFORMER (WHEN PRESENT) JOINT TRENCH DETAIL NOT TO SCALE JOINT TRENCH DETAIL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. * 2. Rocks greater than 10 inches diameter are not permitted in the final backfill. 3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. Primary & Secondary-Mainline Gas & Communications (NTS) ROAD SIDE NATIVE SECONDARY POWER PEDESTAL MATERIAL P/L Power Secondary Power Primary Conduit Tel. & TV 12" Min 12" Sand Cover when gas line is in trench Sand 6" or 12" 4" Sand Bedding 1' 36" Cover 42" Gas 12" 18" Lower 2" 10" Pedestal PSE 10' FRONTAGE EASEMENT 1' Cover ROAD SIDE MINIPAD MINIPAD FIELD SIDE VAULT 6" of crushed rock (base for vault) P/L Power Secondary Power Primary Gas 12" Min Horizontal Separation Communications 42" Min 21"1' Feeder 38" 2" 4" Sand Bedding 12" Sand Cover 36" Cover 4" Sand Bedding 42" 6" Additional depth when Feeder is required PSE 10' FRONTAGE EASEMENT 1' TRANSFORMER Final Backfill Initial Backfill Trench Depth 42" - 48" Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 VAULT DETAIL @ V02 NOT TO SCALE STD 6775.0030 EXCAVATION: _____ CUBIC YARDS 3'-6" SIDE VIEW 2" 6" CRUSHED ROCK TOP VIEW 7' 7' 6 1/3 FAULT CURRENT TABLE ‘3075$16)250(56 9 120V WINDINGS 240V WINDINGS LOCATION SIZE R/X MIN. %Z FAULT CURRENT MIN. %Z FAULT CURRENT V02 75KVA 0.5 2.30 36,200 AMPS 1.80 23,100 AMPS Developer Note: The following Fault Current information MUST BE conveyed to the builder of the units: All units may require upgraded house electrical equipment as the fault current at the meter base may exceed 10,000 amps. CROSSINGS CONDUIT TABLE GAS POWER Length X-ING Location Size Type Qty Location Size Type Qty NO.from to (in)sched each N-S-E-W (in)sched each (ft) X01 LOT 8 LOT 9 2 40 1 WEST 3 80 1 55 SECONDARY, GAS SERVICE X02 LOT 6 LOT 11 2 40 1 EAST 3 2 55 SECONDARY, GAS SERVICE X03 LOT 4 LOT 13 2 40 1 EAST 3 2 55 SECONDARY, GAS SERVICE X04 LOT 3 LOT 14 2 40 1 WEST 3 1 55 SECONDARY, GAS SERVICE X05 3 1 55 SECONDARY ONLY 2" SCHED 40 YELLOW PVC (ft) =220 385 3" SCHED80 GREY PVC (ft) Total 2" PVC Plug /Caps =8 14 = Total 3" PVC Plug Caps Remarks (type of crossing) (Primary, Feeder, Secondary, St. Light, Gas only, etc.,) LOT 1 STM TR 80 80 80 80 SITE SPECIFIC NOTES At P01 - (317716-167906) 2018 CLASS 2 - 45' INSTALL (1) 2" PRIMARY RISER ON S/O BRACKETS (RIS2CSS) 6042.1000 STIRRUP (2254100) ALUM "H" CONN (2168000) FUSE @ 100T (3412700), TAP 'B' PHASE INSTALL SW#T79976 INSTALL 1Ø TERM ON FIBERGLASS ARM W/ LOAD INTERRUPTER CUTOUT & SURGE ARRESTOR (TSU1L1) 6043.1000 336.4 MCMACSRABC 336.4 MCMACSRFUSE @ 100T SW#T79976 #2ACSR CFEEDNEW 1/0 EHO878-BØ NEW 1/0 EHO879-BØ FUSE @ 40T SW#T79976 2 4 53 1014131211 1 76 8 9 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP LEE BROWN 425-417-8620 3/2/18 J.SINGLETON 253-395-6967 3/2/18 J.SINGLETON 253-395-6967 3/2/18 D.KANOWSKY .7/10/17 REDT # ( RW-101556 )RENTON MEADOW VUE 1Ø PRIMARY U/G LINE EXTENSION - 14 S/F LOTS 13833 156th AVE SE, RENTON, WA 98059 PUGET SOUND ENERGY N/A IP 088-60 107054471 105085461 AS SHOWN 2 OF 2 KING 30 CIKNC QCSOKE 14SW-T23-R05E 208.086 209.088 2305E055 2306E076 2306E055 MAP-13 COMCAST BILL WALKER 253-288-7538 CENTURY LINK AMY ALLISTON 206-794-8534 RIGHT OF WAY VAL CONNEL 425-462-3518 . . . ... ... ... THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) EX OVERHEAD CIRCUIT MAP ######## SCALE: 6" = 1 MILE NEW PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAM NOT TO SCALE EX UNDERGROUND CIRCUIT MAP ######## SCALE: 1" = 100' SITE SITE Site Grid Vault Size Type & Size Primary Bushings Transformer ASBUILT INFORMATION Number & Cover Equipment ID Numbers Foreman-Complete in Vault LB DC (Company ID)(Include Trf Phase tapped) 317712 42X48X38 50KVA MP TRF 167890 Unistrut HH 120/240 2 -MINU1SL 6045.1010 (BØ) Matid:7663001 Matid:6247100 317713 54X54X38 75KVA MP TRF 167862 Unistrut HH 120/240 1 1 MINU1LR 6045.1010 (BØ) Matid:7663002 Matid:6247150 Vault & Equipment Table V01 V02 PRIMARY CABLE & CONDUIT TABLE CONDUIT LOCATION Size Qty Design BENDS PULL PULL Cable Design Foreman- Complete Cable Numbers from to (in) Length (ft)90°45°22°11°(lbs) Rev (lbs)Size Length (ft)A B C Manufacturer Compound Year P01 V01 2 1 200 1 1 2 62 154 1/0 AL JKT 245 EHO878 V01 V02 2 1 270 110 110 1/0 AL JKT 290 EHO879 V02 E01 2 1 140 1 1 2" PVC (ft) & Bends =610 1 2 3 0.81 0.26 Qts 535 = Total 1/0 AL JKT (ft) PRIMARY CABLE Foreman Please Record Actual Amount Installed (Conduit & Cable) ASBUILT 42" 45°42" 1' 45°Property LineRoad Side Top View of Mainline Trench for Single Stubout Location 3'Property LineRoad Side Top View of Mainline Trench for Pedestal or Double Stubout Location 42"45° 3' 45° STUBOUT EXCAVATION DIMENSIONS NOT TO SCALE MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF10' 10' 10' COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 3' MIN @ H2A, H2B SHALL BE STAGGERED CONNECTOR BARS IN THE FRONT NEUTRALS SHALL BE 18" 16" 13" 12"10" 2" 10" Pedestal will accept up to six 3" conduits SEALED WITH FOAM CONDUIT SHALL BE 120 PVC CONDUIT ELBOWS TYPICAL 24" RADIUS DB SIDE VIEW WITH CONDUIT 10" 18" 16" 13" 10" 2" 36" FRONT VIEW WITH CONDUIT SECONDARY PEDESTAL DETAIL NOT TO SCALE CLEAR WORKING SPACE FOR VAULTS NOT TO SCALE FIELD SIDE (PREFERRED) ROAD SIDE (PREFERRED) 6' MIN 3' MIN 3' MIN 3' MIN NOT TO SCALE NEW CONDUIT DIAGRAM SECONDARY 2" SECONDARY 3" PRIMARY 2" CONDUIT LEGEND SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE Assumed CONDUIT VOLTAGE VOLTAGE ASBUILT INFORMATION SIZE LENGTH Lot Corner SIZE LENGTH BENDS DROP FLICKER Foreman - Complete FROM TO (1/O,4/O, 350) Design (ft) to Meter (ft)(in) Design (ft)ƒƒƒƒ(Percent)(Percent)Actual Amount Installed (Conduit & Cable) V01 LOT 6 1/O 15 50 2 15 1 1.9 3.0 V01 LOT 7 1/O 15 50 2 15 1 1.9 3.0 V01 LOT 8 4/O 80 50 3 80 1 2.1 3.6 V01 LOT 9 350 155 50 3 100 2 2.2 3.8 V01 LOT 10 4/O 80 50 3 25 2 2.1 3.6 V01 LOT 11 4/O 75 50 3 20 1 2.1 3.5 V02 H2A 350 150 3 150 2 2.0 2.1 V02 H2B 350 190 3 135 3 0.9 2.4 V02 LOT 1 4/O 80 50 3 80 1 1.9 3.0 V02 LOT 2 1/O 15 50 2 15 1 1.6 2.4 V02 LOT 3 1/O 15 50 2 15 1 1.6 2.4 V02 LOT 14 4/O 85 50 3 30 2 1.9 3.1 H2A LOT 4 1/O 50 2 2.5 3.2 H2A LOT 5 1/O 50 2 2.5 3.2 H2A LOT 12 4/O 90 50 3 35 2 2.7 3.8 4/O TO METER H2A LOT 13 4/O 85 50 3 30 1 4/O TO METER 1/O UG Triplex (ft) =60 2" PVC & Bends =60 4 0.2 4/O UG Triplex (ft) =575 3" PVC & Bends =685 17 2.0 350 UG Triplex (ft) =495 Total Qts of Glue =2.2 2.7 3.7 HH/PEDESTAL TABLE Site Pedestal Number of Remarks or Positions (Include phasing information) Handhole Required H2A Handhole 5 SEPL6 6050.1000 (BØ) H2B Pedestal 2 SEPS3 6050.1000 (BØ)CHARGE TO WO#105087299 1 Standoff Bracket 15" Min Length Conduit Clamp Conduit Field Face Quadrant Climbing Space Road Face Quadrant Climbing Space 5" Min CL LCDirection of Vehicular Traffic CONDUIT RISER PLACEMENT DETAIL TOP VIEW NOT TO SCALE COMM HH - CHARGE TO 105087299