HomeMy WebLinkAboutP_Design_101109876_V1_18031416427
316895-166187
316915-166180
37.5 kVA 120/240V (A)
316901-166194
SLAG4262
NEW 25 kVA 120/240V (A)
33
6
.
4
M
C
M
A
C
S
R
3
3
6
.
4
MCM
AC
SR
B
E
N
S
O
N
R
D
S
S 28TH ST
PARCEL#
0087000007 65.5'ROL
15
16501
16425
16427
16515 16533
16543
16415
2705
1408 1414
1409
140914051307
1305
- CUSTOMER TO INSTALL 1-3" SCH'L 40 CONDUIT, ±50'
- PSE TO INSTALL 1-RUN 4/O UG TPX, ±80'
CUSTOMER SUPPLIED
4' X 4' WORK PIT
CUSTOMER SUPPLIED
CUSTOMER SUPPLIED
4' X 4' WORK PIT
CUSTOMER SUPPLIED
3/4" CUBIC YARD OF SAND 1 CUBIC YARD 5/8" CRUSHED ROCK
SITE PLAN
POWER GENERAL NOTES - RESIDENTIAL PROJECT
N
Vicinity Map
N/A
Owner / Developer Contact Info
officeATTN:
OLEG KALINICHENKO
18108 5TH AVE S
BURIEN, WA 98148
OLEG KALINICHENKO 253.988.8892
OVERHEAD CIRCUIT MAP 2305E136
SCALE: 6" = 1 MILE
SCALE: NONE
NEW CABLE & CONDUIT DIAGRAM
CUSTOMER-SUPPLIED SERVICE TRENCH
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
CIRCUIT LOADING TABLE
AS OF
EXIST. PEAK LOAD
EST. NEW LOAD
TOTAL
CIRCUIT:
A PHASE B PHASE C PHASE
ROL-15
6/8/2017
305.00 310.00 329.00
1.75 0.00 0.00
306.75 310.00 329.00
HP Svc/MSA
Distribution
Job Order
Temporary
OH Maintenance
OH Transformer
Removal
Superior
ORDER#NOTIF#
PWR
PROJECT PHASE
N/AN/A
N/A
N/AN/A
N/AN/A
N/AN/A
583058506N/A
108104526N/A
CABLE TV
PHONE
GAS
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
10.
7.
6.
5.
4.
3.
2.
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Inclement weather conditions may cause delays in construction times and dates.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
LRC:
% V. Drop:
% Flicker:
Sq. Footage:
Panel Size:
Heat Type:
Est. Demand:
4500
200A
GAS
12KW
65A
3.0%
2.54%
8.
9.
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
X
X
X
X
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
P01
316901-166194
25kVA
6211250
SCALE: 1" = 50'101109876THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
Service Stubs
101109876
N/A
N/A
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
D. HONEYSETT 253.245.0883 1/16/2018
D. HONEYSETT 253.245.0883 1/16/2018
E. ORTIZ 714.893.2405 1/16/2018
N/A RENTON
KALINICHENKO NEW SFR
TRF INSTALL, SECONDARY UPGRADE, OH TO UG PERM SVC
16427 BENSON RD S, RENTON, WA 98055
N/A N/A
N/A 101109876
AS NOTED 1 OF 1
KING N/A N/A CSPSKEIN
29NW-T23R-05E N/A N/A
2305E114 2305E136 2305E114 ROL-15
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
505297366
N/A
CIRCUIT FEET ADDED: 0 SITE SPECIFIC NOTES
AT P01: 316901-166194
-EXISTING 45' CL 1 POLE (2003) TO REMAIN
-INSTALL 25kVA 120/240v (FUSE @ 10T) (TRFRXF) PER STD 6025.1000
,167$//$/80,18067,5583&/$03 7$3$2254100)
-CONNECT NEW 4/O OH TPX SECONDARY (SW) & ST LIGHT TO TRF
AT P02: 316895-166187
-EXISTING 30' CL UNK POLE (1959) TO REMAIN
-INSTALL 3" SEC RISER (RIS3CSS) PER STD 6042.1000
-TRANSFER EXISTING OH SVC "16501" TO NEW 4/O OH TPX SEC
AT P03: 316915-166180
-EXISTING 45' CL 2 POLE (2009) TO REMAIN
M01 AT "16427": NEW PERMANENT METER
-PSE METER DEPARTMENT TO SET CL200A METER
M02 AT "16427": REMOTE TEMP METER
-PSE METER DEPARTMENT TO REMOVE TEMP METER
SPAN SPECIFIC NOTES
P01 TO P02:
5(029((;,67,1*22+73;6(&21'$5<
,167$//5812+73;6(&21'$5<
P02 TO M01 "16427":
&86720(572,167$//',6&217,18286*5(<6&+
/&21'8,7
,167$//58128*73;¶
P02 TO M02 "16427" (TEMP METER):
-REMOVE EXISTING OH SVC CONDUCTOR
P01 TO P03:
5(029((;,67,1*22+73;6(&21'$5<
-EXISTING OH TPX BRIDLE SVC TO "16425" TO REMAIN
JOB SITE
JOB SITE
TV & TEL Electric Service Cable in Conduit
3" Schedule 40 Grey PVC
Excavated Dirt Pile
Final Grade
24" Min
24" Min
to
36" Max
Cover
Backfill for Conduit
Free of rocks
larger than 8"
in diameter
Separation
12" Min
in Conduit
Schedule 40 White PVC
Gas Service Line
32" Typical
(Power, Gas,
Phone & Cable)
Separation
12" Min
12" Min
Separation
36" MINIMUM COVER
IN RIGHT OF WAY
JOINT TRENCH DETAIL
Joint Service Line in Conduit (NTS)
To Excavated Dirt Pile
Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.
CUSTOMER & DEVELOPER NOTES
THE CUSTOMER IS RESPONSIBLE TO PROVIDE ALL TRENCHING, SELECT BACKFILL, COMPACTION &
RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500
5(48,5('723529,'( ,167$//´',6&217,182866&+('8/(39&&21'8,7)520P02-M01 +/- 50'
5(48,5('723529,'( ,167$//´12132/<38//523(,1$//&21'8,76
-REQUIRED TO PROVIDE 4' X 4' WORK PIT & 1 CUBIC YARD 5/8" CRUSHED ROCK AT P01
5(48,5('723529,'(¶;¶:25.3,7 &8%,&<$5'2)6$1'$7M01
-REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL
-REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES
-REQUIRED TO EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION
-PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL
-PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE
-RENTON CITY INSPECTION & APPROVAL IS REQUIRED 5 BUSINESS DAYS PRIOR TO CONNECTION
OUTAGE LIST
-16427 BENSON RD S, RENTON, WA 98055 - OLEG KALINICHENKO
-16501 BENSON RD S, RENTON, WA 98055 - TEODOLFO C SAIREZ
WIRE STRINGING
PRIMARY & SECONDARY
Location
Pri Sec Wire Size & Type Quantity
Length
(per
conductor)ToFromTo
P01 P02 S 4/0 OH TPX 135 135
WIRE REMOVAL TABLE
Location Wire Size & Type Quantity
Length
(per
conductor)
Remarks
From To
P01 P02 1/0 OH TPX 135 135
P01 P03 1/0 OH TPX 160 160
P02 M02 #2 OH TPX 60 60
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:DAVE HONEYSETT
253-245-0883
DAVE.HONEYSETT@PSE.COM
METER DETAIL @ M01
SCALE: NONE
32"
Typical
24"
Min
24"-36"
4'Top View
Electric & Joint Utility
Work Pit Dimensions
36"
Min
Drainage Pipe
12" Minimum Clearance
from Gas Service Lines
Conduit Depth
24" to 36" Max
Regulator
Gas Meter
Assembly
48"
4'8"
Service (Permanent Detail:)
Not to Scale
Conduit
Ends
Closed
4'8"
24" Min
36" Typical
3'
To Trench
Property Line
Conduit Stakes
Customer Provided
3" Schedule 40 Grey PVC
Power Cable Conduit
Customer Provided
Gas Service Line Conduit
Sch 40 White PVC
Customer Provided
3" Conduit Service Riser
Customer Provided
Elec. Mtr Base
Elec Mtr
utility provided
Gas Meter
Relief Vent
Building Wall
Elec. Mtr
Vent
Utility
Provided
Seal
24"-36"