Loading...
HomeMy WebLinkAboutP_Design_101112397_V1_180521317074-167402 37.5kVA 120/240v S E 1 5 8 T H S T JOB SITE GAS PHONE CABLE TV N/A 584043182 N/A 594120789 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior XFMR Expense UG Expense Removal Temporary Job Order Distribution HP Main HP Svc/MSA PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)101112397N Vicinity Map NOT TO SCALE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Correct QC Checklist(s) reviewed. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP S. RUSSU 253-395-6352 5/2/18 S. RUSSU 253-395-6352 5/2/18 A. CABRERA 562-292-0135 5/2/18 N/A RENTON XFMR RAISE - RENTON XFMR RAISE 15809 140TH CT SE RENTON, WA 98058 ASPLUNDH CONSTRUCTION CORP. 101112397 AS NOTED 1/1 KING QCSOKE 2305E088 2305E088 FWD-162305E088 OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE MAP#: 2305E088 11417842 101112397 SITE MAP SCALE: 1" = 50' CIRCUIT FEET ADDED: NONE Owner / Developer Contact Info officeATTN: CONTACT PSE PROJECT MANAGER SERGEY RUSSU 253-208-9712 SITE SPECIFIC NOTES V01 (317074-167402) -REMOVE ALL ROTTEN RETAINING RAILROAD TIES WALL -REMOVE SOIL TO EXPOSE EXISTING 37.5kVA PADMOUNT TRANSFORMER -INSTALL (2) 6" RISERS (MID: 7807901) -INSTALL (1) 4" RISER (MID: 7807900) -INSTALL 32" HILLHOLDER (MID: 7661510) -INSTALL NEW 37.5kVA PM TFR (MID: 6246050) -INSTALL (2) ELBOW PER STD 6041.1000 (ELB10J) -INSTALL (3) CONNECTOR BLOCKS (MID: 4842001) -SPLICE & EXTEND PRIMARY CABLE BØ33749 -SPLICE & EXTEND SERVICE CABLE THOMAS GUIDE 656-C5 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. E-Mail: Cell Phone: Project Manager Contact Information: Manager:SERGEY RUSSU 253-208-9712 SERGEY.RUSSU@PSE.COM COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA @ V01 PLACE PEA GRAVEL BAGS (MID 9995892) FOR SEDIMENT TRAP PLACE STRAW MULCH ON DISTURBED AREA AUGERED HOLE POLE TYPICAL AUGERED WORK SITE - 0150.3200 TECHNIQUES FOR EROSION AND SEDIMENT CONTROL DITCH OR SENSITIVE AREA @ V01