HomeMy WebLinkAboutMFP18003011DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP18003011 IVR Number: 18003011 Permit Informaon Permit Name:Puget Sound Energy - Electric Address/Locaon :06/06/2018Application Date:7224000580Parcel Number:332 PARK AVE N Permit Type:07/05/2018Issue Date:Franchise Permit Work Class:07/05/2019Expiration Date:Minor Utility Job Number:101112247Franchise Type:Electric Description:Remove 2 submersible transformers, install two padmount transformers, install two concrete secondary handholds, re plumb and re route existing primary and secondary to new transformers and handholds. Pothole all existing utilities. Restoration per City of Renton Standards. Contacts Name Address PhoneTypeBilling ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: BL.005109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 101112247 Anish Kumar 253-208-2183 anish.kumar@pse.com 332 Park Ave N 98056 101112247 Remove 2 submersible transformers, install two padmount transformers, install two concrete secondary handholes, re-plumb and re-route existing primary and secondary to new transformers and handholes. No pavement cuts. Restoration per City of Renton standards. Potelco Inc.253-208-2183 BL005109 Poteli*227PL 5/31/2018 Scott Warlick 6/6/2018 MFP18003011 Justin Johnson 7-5-2018 pothole all existing utilities. CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form 101112247 PSE/Potelco Inc. Marc Bayley 253-234-6432 6905 S 228th St, Kent, WA 98032 marcus.bayley@pse.com 332 Park Ave N TBD 6/24/2018 Anish Kumar 5/31/2018 MFP18003011 8:00 am to 3:00 pm Monday through Friday Justin Johnson 7-5-2018 SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). 12121212121211111111111111777710200' 200'100'100'100'100'100'100'MATCHLINE SEE ABOVE 12121212121220202020200' 200' 200' MATCHLINE SEE BELOW Job#101112247332 Park Ave N, Renton, WAMay 11, 2018Sheet 1 of 2 gregory.harwood@pse.com(425) 424-6425www.trafficmanagement.com800.763.3999Traffic Control Services - Sales & RentalsPermits & Consulting - Engineering - TrainingPLAN PREPARED BY:DATE: 5/11/18PLAN ORDER: 36953TMI CONTACT PERSON: Michael FlanaganTCS CERT #: 301872CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040LANEWIDTHSPOSTED SPEED LIMITS20253035404510111255 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MFP18003011 121212121212121212121212202020201111201111111110100'100'100'200'200'100'100'100'Job#101112247332 Park Ave N, Renton, WAMay 11, 2018Sheet 2 of 2 gregory.harwood@pse.com(425) 424-6425www.trafficmanagement.com800.763.3999Traffic Control Services - Sales & RentalsPermits & Consulting - Engineering - TrainingPLAN PREPARED BY:DATE: 5/11/18PLAN ORDER: 36953TMI CONTACT PERSON: Michael FlanaganTCS CERT #: 301872CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040LANEWIDTHSPOSTED SPEED LIMITS20253035404510111255 +60/6545/5535/403025SIGN SPACING"X"800500'350'200'100'MFP18003011 318 310 304 300 1304 248 240 238 230 235 238 326 247 1211 1207 1201250 248 240 236 232235 247 301 315 249 J J J318061-166207 37.5 kVA 120/240V (C) 318061-166191 50 kVA 120/240V (C) 318061-166203 50 kVA 120/240V (C) 318061-166217 37.5 kVA 120/240V (C) N 3RD STPARK AVE NGARDEN AVE N318057-166223 318061-166233 50 kVA 120/240V (C) 318064-166224 X3470 X3470 SLAG7883 318073-166224 10 kVA 120/240V (A) SLAG7884 SLAG7885 318044-166223 UNK SLAG7882 318049-166178 UNK 318069-166179 25 kVA 120/240V (C) 318074-166174 318049-166178 UNK 318073-166214 500 kVA 120/208V 60'PCR 14 PCR 14 PCR 14 318064-166224 X3470 X3470 SLAG7883 J J J PROPOSED 10' EASEMENT PROPOSED 10' EASEMENT (3) 750KCMIL(1) 1/0 AL SOL 336.4KCMIL ACSRABC336.4KCMIL ACSRABC 00 1"2" 00 50'100' SITE PLAN N Vicinity Map N/A Owner / Developer Contact Info officeATTN: Renton School District #409 7812 S 124th ST Seattle, wA 98178 Matt Feldmeyer (425) 204-4475 SITE SPECIFIC NOTES OVERHEAD CIRCUIT MAP SCALE: 6" = 1 MILE FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. 108106462 584043027 594120879 PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X E-Mail: Cell Phone: Project Manager Contact Information: Manager:Marc Bayley (253) 259-4494 Marcus.Bayley@PSE.com SCALE: 1" = 50' Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: V01 318061-166217 37.5kVA 6247050 101112247THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Marc Bayley (253) 234-6432 5/4/18 Nate Linville (253) 970-7284 5/4/18 Nate Linville (253) 970-7284 Required City of Renton Sartori Elementary Relocation Remove (2) TUT, Install (2) PM Transformers 332 Park AVE N, Renton, WA 98056 101112247 As Noted 1 of 3 King CSPSKEPM NW-17-23N-05E 2305E066 2305E088 2305E066 GRA-17 101112247505910446 Installed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER INSTALLATION Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: V03 318061-166203 50kVA 6247100 Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V02 318061-166207 37.5kVA Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V04 318061-166191 50kVA AT J01: EXISTING 318057-166223 EXISTING VAULT TO REMAIN REMOVE EXISTING B/O 4POS JBUS ON (S) WALL [594120879 2-45] -INSTALL (1) NEW 4POS JBUS ON (S) WALL AT V01: NEW 318061-166217 - 101112242 -INSTALL (1) 36" X 42" X 38" UNI-STRUT MINI-PAD HAND HOLE PER STD 6045.1010 (MINU15S) [2-60] -INSTALL (1) 37.5kVA 120/240V 1Ø PM TRANSFORMER (MID: 6247050) [2-45] -INSTALL (2) LB ELBOWS PER STD 6041.1000 (ELB10J) [2-57 X2] -INSTALL (3) 5/8" STUD #6-350KCMIL 6POS SECONDARY CONNECTION BARS (MID: 4842001) -INSTALL GRID 318061-166217 TRANSFER CABLE #CØ-10159 FROM V02 -INSTALL CABLE #CØ-EHX807 AT HH1: NEW -INSTALL (1) 2'6" X 2'6" X 2' CONCRETE SECONDARY HAND HOLE W/ ANTI-SKID DOOR PER STD 6050.2000 (HH14350AS) [2-34] -INSTALL (3) #10-350KCMIL SECONDARY CONNECTION BLOCKS TRANSFER CABLE #CØ-10159 TO V01 AT V02: REMOVE 318061-166207 REMOVE EXISTING 37.5kVA 120/240V TUT AND RETURN TO PSE YARD [2-45] REMOVE EXISTING 4'8" X 4'8" X 6' VAULT [2-60] AT V03: NEW 318061-166203 -INSTALL (1) 36" X 42" X 38" UNI-STRUT MINI-PAD HAND HOLE PER STD 6045.1010 (MINU15S) [2-60] -INSTALL (1) 50kVA 120/240V 1Ø PM TRANSFORMER (MID: 6247100) [2-45] -INSTALL (1) LB ELBOW & (1) DUST CAP PER STD 6041.1000 (ELB10J) [2-57] -INSTALL (3) 5/8" STUD #6-350KCMIL 6POS SECONDARY CONNECTION BARS (MID: 4842001) -INSTALL GRID 318061-166203 AT HH3: NEW -INSTALL (1) 2'6" X 2'6" X 2' CONCRETE SECONDARY HAND HOLE W/ ANTI-SKID DOOR PER STD 6050.2000 (HH14350AS) [2-34] -INSTALL (3) #10-350KCMIL SECONDARY CONNECTION BLOCKS INTERCEPT EXISTING 3" CONDUIT, PLUMB FROM V03 TO NEW HAND HOLE INTERCEPT EXISTING UG SECONDARY TRPLEX TO HH4 AT V04: REMOVE 318061-166191 REMOVE EXISTING 37.5kVA 120/240V TUT AND RETURN TO PSE YARD [2-45] REMOVE EXISTING 4'8" X 4'8" X 6' VAULT [2-60] AT J02: EXISTING 318049-166178 EXISTING JBOX TO REMAIN REMOVE NEUTRAL TIE FROM V04 TO J02 SPAN NOTES IP1 & IP2 TO V01 INTERCEPT EXISTING 2" CONDUIT, PLUMB INTO V01 [2-36] STRIP BACK CABLE #CØ-10159 FROM V02 AND ROUTE TO V01 IP3 TO V01 INTERCEPT EXISTING 2" CONDUIT, PLUMB INTO V02 [2-36] IP4 TO HH2 INTERCEPT EXISTING 3" SECONDARY CONDUIT [2-36] REMOVE EXISTING 350KCMIL SECONDARY TPLX CABLE V01 TO HH1 -INSTALL (1) RUN 350KCMIL SEC TPLX ±70' _____' ACTUAL [2-54A] HH1 TO HH2 INSTALL (1) RUN 350KCMIL SEC TPLX ±80' _____' ACTUAL [2-54A] V02 TO HH1 REMOVE EXISTING (1) 350KCMIL SEC TPLX ±10' [2-54A] V03 TO HH2 -INSTALL (1) RUN 350KCMIL SEC TPLX ±50' _____' ACTUAL [2-54A] V04 TO HH2 REMOVE EXISTING (1) 350KCMIL SEC TPLX ±10' [2-54A] DEVELOPER & CUSTOMER NOTES: THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS 6750.6500 -REQUIRED TO PROVIDE 6' X 6' WORK PIT & 1 CUBIC YARD OF 5/8" MINUS AT V01 & V03 -REQUIRED TO PROVIDE 6' X 6' WORK PIT FOR IP1& IP2, IP3, AND IP4 -REQUIRED TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL -REQUIRED TO PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS & TRENCH AT ALL TIMES -EXCAVATE & EXPOSE EXISTING PSE UG FACILITIES 48 HOURS PRIOR TO CONSTRUCTION -PSE INSPECTION IS REQUIRED PRIOR TO FINAL BACKFILL -PSE WILL NOT ENERGIZE FACILITIES UNTIL BACKFILL IS COMPLETE -L&I INSPECTION & APPROVAL IS REQUIRED 72 HOURS PRIOR TO CONNECTION -RESPONSIBLE FOR ALL TREE TRIMMING AND BRUSH CLEARING UNDERGROUND CIRCUIT MAP SCALE: NONE JOB SITE JOB SITE CIRCUIT FEET ADDED: 180 CIRCUIT FEET REMOVED: 200' MFP18003011 318061-166217 37.5kVA 120/240V 318061-166203 50kVA 120/240V EXISTING 2" CONDUIT EXISTING 2" CONDUIT 6' X 6' WORK PIT CUSTOMER PROVIDED 9' X 10' WORK PIT CUSTOMER PROVIDED 6' X 6' WORK PIT CUSTOMER PROVIDED 6' X 6' WORK PIT ±20'90° R=48"±20'90° R=48" 90° R=48"±20'318061-166217 37.5kVA 120/240V 318061-166203 50kVA 120/240V CØ-EHX803 318061-166217 37.5kVA 120/240V 318061-166203 50kVA 120/240V PSE PROVIDED & INSTALLED (1) NEW 1/0 AL SOL CØ-EHX803 EXISTING 1/0 AL SOL CØ-10159 PRIMARY CABLE ONE-LINE DIAGRAM SCALE: NONE 101112247UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Marc Bayley (253) 234-6432 5/4/18 Nate Linville (253) 970-7284 5/4/18 Nate Linville (253) 970-7284 Required City of Renton Sartori Elementary Relocation Remove (2) TUT, Install (2) PM Transformers 332 Park AVE N, Renton, WA 98056 101112247 As Noted 2 of 3 King CSPSKEPM NW-17-23N-05E 2305E066 2305E088 2305E066 GRA-17 UNDERGROUND CIRCUIT MAP (AFTER) SCALE: NONE PRIMARY CONDUIT DIAGRAM SCALE: NONE UNDERGROUND CIRCUIT MAP (before) SCALE: NONE PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT PRIMARY CABLE ASBUILT INFORMATION SIZE Qty LENGTH Design (ft) BENDS PULL PULL Cable LENGTH Design (ft) Cable Numbers Foreman Please Record Foreman - Complete FROM TO (in)90°45°22°11°(lbs) Rev (lbs)Size A B C Manufacturer Compound Year Actual Amount Installed (Conduit & Cable) J01 V01 2 1 EX 130 NEW 30 2 0 0 0 48 46 PRI 12KV 1/0 UG 160 10159 V01 V03 2 1 30 EXISTING 140' 2 0 0 0 33 33 PRI 12KV 1/0 UG 160 EHX807 ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE CABLE REPLACED?FROM TO 10159 10502898 IP1 V02 30' 10158 10502887 V02 V04 180 TOTAL 180' GUARD POSTS FOR PADMOUNT EQUIP. TYPICAL TRANSFORMER 0700.1600Not to scale 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 5' MAX 3' MIN 8' x 8' OR 10' x 10' CONCRETE PAD GUARD POSTS ACCESS DOOR SWING 4' MIN 18' MIN 3' MIN CL CL 18' MIN COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 6775.0035 Not to scale Communications Primary Power Cables or Conduit Excavated Dirt Pile ROADSIDE Final Grade 24" Min 12" Min Separation 36" Min Cover 48" Max Backfill (No rocks over 10" diameter) Separation 12" Min Gas 4" Sand Bedding 32" Typical (Power, Gas, and Communications) JOINT TRENCH DETAIL Primary-Mainline Gas & Communications (NTS) Separation 12" Min 6" or 12" Min Sand Shading after Compaction - A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. FLOW DIRECTION LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL, SECURE WITH PEA GRAVEL BAGS (MID 9995692). 6' 3' 8" TECHNIQUES FOR EROSION AND SEDIMENT CONTROL SILT FENCE DETAIL Not to Scale 0150.3200 MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF10' 10' 10' MFP18003011 318061-166217 37.5kVA 120/240V 318061-166203 50kVA 120/240V EXISTING (1) 3" CONDUIT CUSTOMER PROVIDED 6' X 6' WORK PIT CUSTOMER PROVIDED 6' X 6' WORK PIT CUSTOMER PROVIDED 6' X 6' WORK PIT 90° R=36" 45° R=36"±20'±70'±70'EXISTING (1) 3" CONDUIT PSE PROVIED (1) 3" SCH80 PVC CONDUIT PSE PROVIED (1) 3" SCH80 PVC CONDUIT CUSTOMER PROVIDED 6' X 6' WORK PIT ±50'±20'±40'90° R=36" 318061-166217 37.5kVA 120/240V 318061-166203 50kVA 120/240V ±20'90° R=36"45° R=36"±20'±70'±70'EXISTING (1) 350KCMIL SEC TPLX NEW (1) 350KCMIL SEC TPLX IN EXISTING 3" CONDUIT ±40' ±50' PSE PROVIDED (1) 350KCMIL SEC TPLX PSE PROVIDED NEW (1) 350KCMIL SEC TPLX 90° R=36" SECONDARY CONDUIT DIAGRAM SCALE: 1" = 50'101112247UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Marc Bayley (253) 234-6432 5/4/18 Nate Linville (253) 970-7284 5/4/18 Nate Linville (253) 970-7284 Required City of Renton Sartori Elementary Relocation Remove (2) TUT, Install (2) PM Transformers 332 Park AVE N, Renton, WA 98056 101112247 As Noted 3 of 3 King CSPSKEPM NW-17-23N-05E 2305E066 2305E088 2305E066 GRA-17 SECONDARY CABLE DIAGRAM SCALE: NONE TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts VAULT & EXCAVATION DETAIL AT V01 & V03 Not to scale 6045.1000 1950 lbs PROPOSED UG PRIMARY EXISTING UG PRIMARY PRIMARY SPLICES SPLICE PIT DETAIL IP1 & IP2 SCALE: NONE TO V03FROM J01 TO V01 SINGLE PHASE SECONDARY CONCRETE HANDHOLE AT HH1 & HH3 Not to scale 6050.2020-1 TOP VIEW SIDE VIEW 2'-4" EXCAVATION: 5-1/3 CUBIC YARDS 6'-0" 6'-0" 6" Crushed rock 2" 2'-6" Install PVC bell ends and grout into wall 2'-6" Handhole 820 lbs Conduits and conductors shall enter from ends of handhole through knockouts provided Typical customer run service conductors in duct Steel Door Seal conduit with foam Customer-installed grounding wires ( the "4th" wire on the single-phase systems and the "5th" wire on the three-phase systems) shall not be connected to PSE's ground or neutral bus. They shall be removed by customer or cut off at the vault wall. PROPOSED UG PRIMARY EXISTING UG PRIMARY PRIMARY SPLICES SPLICE PIT DETAIL IP3 SCALE: NONE FROM V01 TO V03 MFP18003011