HomeMy WebLinkAboutP_Design_101113708_V1_181106cV
CIRCUIT FEET REMOVED: 720' 317965-166061 J04
CIRCUIT FEET ADDED: 945' J
Sq. Footage: 61,500 — —
Panel Size: 2500AMPS
Heat Type: ELEC j
317964-166060
Est. Demand: 226KW
LRC: 616A
% V. Drop: 1.8%
% Flicker: 2.2%
720" I I
I
I
I I
S TOBIN ST
li
I 1 1 75
17911 iK
I
I I 1
I 317942-166061 V03
100kVA 120/240v O -�
"81.,
"87"
I
tot — —
1 119111
91" 1
317 26-166036 I 1
119511
P I
p
L--- \
9911
I �
t �
- I �
I
FL
L "101" /
I
317912 166036 — — --�
X96 I I 1 /
X9557 I "107" 1 I /
110'
— — 4 P2
317903-166060 I IP3
500kVA 120/208V V02 T
VO1 �
DEVELOPER RESPONSIBLE
FOR CONDUITNVIRE FROM M H H 1 I
VAULT TO METER LOCATION Moll (TYPICAL)
IP4 J02 31789 -1660 3
317897-166036
37.5kVA 120/240v 3179 -166067
225WV 120/208v
? I (10504312) 317901e
a I 75kVA 1
3 893- 66062 \
"116"
I I
I
'
60
I I ROW I
I I
"124"
I
I I
317881-166065
3 X 50kVA 120/240v
@ IL1023283
I
I
I
I
-� 317948-166066
"74"
/ "78"
L I
317938-1 6063 "82"
I "84„
I (
co
a
Q
J
O ` 317928-166066
I
"94"
31791E-166062 j'gg"
EROSION & SEDIMENT CONTROL REQUIREMENTS
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
CUSTOMER OWNED AND INSTALLED SECONDARY WIRE TABLE
BLDG.
SPAN
SOURCE
# OF RUNS
WIRE SIZE
REMARKS
TO
METERS
-
-
-
UPGRADE TO 500kVA
"104"
1
V02
9
350KCMIL
11358974
317902-16606
75kVA 120/24
DEMO/REBUILD
"104"
I /
I
I /
/
317883-166035 /
"71 0"
317877-166059 J01
SITE PLAN
I SCALE: 1" = 50'
DEDICATED FACILITIES (101113708) for LRC
17910-166066
J03 /
J /�
SITE
#
SPAN
ADDITIONAL
FOOTAGE
REMARKS
LABOR UNITS
FROM
TO
V02
-
-
-
UPGRADE TO 500kVA
-
ALL CUSTOMER -OWNED WIRE MUST BE INSTALLED ACCORDING TO THIS TABLE
� 6..
51�1'
4'-8"
44"
20"
0 0
3'-6"
4'-8" �' 4'-8"
VAULT DETAIL V02
SCALE: NONE
SIDE VIEW
Excavation - 10-1/3 cubic yards
SITE SPECIFIC NOTES
AT V01 (317902-166060)
-REMOVE EXISTING 30 JBUS
AT J02 (317898-166073)
-INSTALL NEW 575 VAULT AND (4) J -BUSSES
AT HH1
-REMOVE EXISTING CONCRETE HANDHOLE
AT IPI
-INTERCEPT EXISTING 2" CONDUIT AND RE-ROUTE TO J02
AT IP2 & IP3
-INTERCEPT EXISTING 4" CONDUIT AND RE-ROUTE TO J02
AT IN
-INTERCEPT EXISTING 4" CONDUIT AND RE-ROUTE TO J02
-RE-ROUTE EXISTING 30 PRIMARY TO J02
TAGS: AOAC1696, BOACI697, COAC1698
CUSTOMER DEVELOPMENT NOTES
A PRE CONSTRUCTION MEETING IS REQUIRED WITH YOUR PROJECT MANAGER
PRIOR TO STARTING ANY SITE WORK.
CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL,
COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS &
LOCAL MUNICIPALITY.
**DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL**
CUSTOMER IS RESPONSIBLE FOR THE FOLLOWING:
VAULTS & WORK PITS.
-PROVIDE A 5'X 10' WORK PIT AT IP1, IP2.
-PROVIDE A 9'X 11' WORK PIT & 5/8 MINUS CRUSHED ROCK AT J02 & V02.
TRENCHING & CONDUIT.
-PROVIDE ±150' OF TRENCHING FROM J02 TO V02.
-PROVIDE ±10' OF TRENCHING FROM J02 TO IP1.
-PROVIDE ±10' OF TRENCHING FROM J02 TO IP1.
JOB SITE READINESS.
-JOB SITE NEEDS TO BE 100% READY FOR INSPECTION 5 BUSINESS DAYS PRIOR
TO CONSTRUCTION DATE.
-ALL WORK IN RIGHT OF WAY MUST BE COORDINATED WITH PROJECT MANAGER
AND LOCAL MUNICIPALITY.
-ALL TRENCH, AND LOCAL ELECTRICAL MUNICIPALITIES AKA "L&I, CITY",
INSPECTIONS MUST BE COMPLETED 5 BUSINESS DAYS PRIOR TO SCHEDULED
CONSTRUCTION DATE.
-REQUIRED TO OPERATE AND PROVIDE EQUIPMENT TO PUMP OUT WATER FOR
WORK PITS, VAULTS & TRENCH AT ALL TIMES.
-REQUIRED TO HAVE EXCAVATION EQUIPMENT AND BE ON SITE THE DAY OF
CONSTRUCTION TO COMPLETE BACKFILLING.
-IF A SECOND INSPECTION IS REQUIRED, ADDITIONAL FEE'S WILL BE APPLIED.
-PLEASE REVIEW THE CITY OR KING COUNTY TRENCHING REQUIREMENTS UNDER
THE PERMIT.
-IF A PRE -CON IS REQUIRED BY THE CITY, COUNTY OR W.S. DOT A PSE PROJECT
MANAGER WILL SET-UP AND SCHEDULE A MEETING WITH THE MUNICIPALITY
BEFORE ANY EXCAVATION OR INSTALLATION BEGINS.
LOW PROFILE SITE PLAN
NOT TO SCALE
y
TOP VIEW
SIDE VIEW
.7
000 000
000 000
000 000
000 000
Excavation - 19-1/2 cubic yards
6„
Crushed 51-411
Rock
THREE PH PRIMARY J -BOX DETAIL @ J02
Not to scale 6055.1030-01
POWER GENERAL NOTES - COMMERCIAL PROJECT
1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
3. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
4. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
5. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
6. Roads shall be paved or have a compacted, crushed rock base in place.
7. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
8. All work is to be done in accordance with local municipal and county permit requirements as applicable.
9. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
10. Inclement weather conditions may cause delays in construction times and dates.
11. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
CIRCUIT LOADING TABLE
CIRCUIT: GRA -17
AS OF 6.6.18 A PHASE B PHASE C PHASE
EXIST. PEAK LOAD
200
198
217
EST. NEW LOAD
13
13
13
FOTAL 213 211 230
ABANDONED / REMOVE / REPLACED CABLE SCHEDULE
CABLE NO.
SAP
EQUIP
LOCATIONS
CABLE EXISTING CABLE EXISTING CABLE
(LF) EST MFG. NAME MFG. DATE
CABLE
REPLACED?
Notes
FROM
TO
AOAC1699
11358975
V01
J04
655
594123431
COAFG338
11358974
655
BOAFG337
11358973
V03
V01
390
DRAWN BY T. MULLENIX
206.305.6912 10.23.18
AOAEK271
11478346
V01
J03
70
PLAT MAP
N/A
APPROVED BY
BOAEK272
11478347
70
U -MAP NO (POWER)
2305EO69
COAEK273
11478348
70
FOREMAN #2
TOTAL 1610'
FOREMAN (CHECK BOX WHEN COMPLETED)
❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
❑ Field Changes RED -LINED on As -built.
❑ Material VERIFIED and CHANGES noted on Paperwork.
❑ Total PRIMARY Cable noted on As -built.
❑ Company ID#'s RECORDED in correct location on As -built.
❑ Indicate correct FUSE SIZE on As built & VERIFY proper PHASE.
❑ Deviations noted on the As -built and their reason.
❑ I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
Foreman's Signature
Print Name Date
PROJECT PHASE
NOTIF#
ORDER#
PWR Superior
Perm. Service
TESP Install
TEST Removal
TESP UG Expense
506165395
104306923
506165393
101113708
108107752
11461049
101114712
1
108108632
594123431
206.305.6912 10.23.18
REV# DATE
BY DESCRIPTION
ENGR - GAS N/A
N/A N/A
COUNTY
KING
Emer Sect Gas Wk Ctr
N/A N/A
POWER WK CTR
QCNOKE
DRAWN BY T. MULLENIX
Project Manager Contact Information:
Manager.' VAL BUZUNOV
Cell Phone: 425-457-9938
E -Mail: VAL.BUZUNOV@PSE.COM
Vicinity Map
47.4823,-122.2064
N
Salvation Army Church sy.
S Tobin St L�'s�
aAOr yR�y
at � w
Q
3
Jones Park;,
W� W
� f
m � —
� b
SOB SITE
U.S. Bank Branch n
`y A
ase Bank o Cheers Bar & jFJ N
'" Grill Renton
Q S 2nd St
9 R( nton Park & Ride g
- m
d y
W � b
Owner/ Developer Contact Info
MGP 47 LLC C/O MERRILL GARDEN
1938 FAIRVIEW AVE E, SUITE 300
SEATTLE, WA 98102
ATTN: JAY WERNER 425-462-9441 office
For contacts below dial 1 -888 -CALL PSE (225-5773)
CALL (8001424-5555
Developer YesX
"Locates Required" No
"Outages Required" YesX
"Flagging Required" YesX
YesX PSE 2 BUSINESS DAYS BEFORE YOU DIG
No THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
No REAL ESTATE/EASEMENT PERMIT
No RW -111377 RENTON
3
FUNCTION CONTACT
PHONE NO DATE
2
PROJECT MGR VAL BUZUNOV
425-457-9938 9.17.18
1
ENGR - POWER T. MULLENIX
206.305.6912 10.23.18
REV# DATE
BY DESCRIPTION
ENGR - GAS N/A
N/A N/A
COUNTY
KING
Emer Sect Gas Wk Ctr
N/A N/A
POWER WK CTR
QCNOKE
DRAWN BY T. MULLENIX
206.305.6912 10.23.18
CHECKED BYIx
t3f/
1/4 SEC
NE 18 -23N -05E
OP MAP
N/A
PLAT MAP
N/A
APPROVED BY
FOREMAN #1
U -MAP NO (POWER)
2305EO69
OH CKT MAP
2305EO76
JUGCICTMAIP
2305EO69
ICIRCUITNO
GRA -17
FOREMAN #2
MAPPING
JOINT FACILITIES ARRANGEMENTS
UTILITIES
N/A
N/A RIGHT OF WAY
N/A
CONTACT
PHONE#
N/A
N/A AMBER YANG
N/A
WA N/A 425.456.2774
NIA
PUGET SOUND
ENERGY
104 BURNETT AVE S
3fTS PRIMARY LINE EXTENSION
104 BURNETT AVE S, RENTON, WA 98057
INCIDENT MAOP
N/A N/A
Gas Order Elect Order
N/A 101113708
SCALE PAGE
AS NOTED 1/2
z
0
+ 5'X 10 WORK PIT
I
IP1 IP2 I PSE TO SUPPLY & INSTALL
±10' OF 4" SCHL 80 CONDUIT
PSE TO SUPPLY & INSTALL IP2
±10' OF 2" SCHL 80 CONDUIT - __q0
9'X 11' WORK PIT 8' 4"R 5' X 10' WORK PIT
9' X 11' WORK PIT _ _ 140_ r PSE TO SUPPLY & INSTALL
C49"R
00 J02 ±10'OF 4" SCHL 80 CONDUIT
I133
I
PSE TO SUPPLY & INSTALL
±150' OF 4" SCHL 80 CONDUIT
CONDUIT DIAGRAM
SCALE: NONE
AOEIB704
COEIB706
1
PSE TO INSTALL ±700' OF
/20 1/0 AL JKT PRIMARY
CABLE
I
PSE TO INSTALL ±400' OF (�
10 1/O AL JKT PRIMARY
CABLE
B0EIB705
a0EI6701
PSE TO INSTALL ±10' OF 10 BOEIB702
1/0 AL JKT PRIMARY CABLEV01 COEIB703
A0EIB707 0-1 J03
B0E1B711
BOEIB708 — —
COEIB709
JPSE TO INSTALL ±85' OF 30
027\2:)0
V02 1/0 AL JKT PRIMARY CABLE
PSE TO INSTALL ±160' OF
30 1/0 AL JKT PRIMARY
CABLE
BOEIB710
PSE TO INSTALL ±10' OF
10 1/O AL JKT PRIMARY
JUMPER CABLE
CABLE DIAGRAM
SCALE: NONE
SCALE: 6" = 1 MILE
PRIMARY CABLE & CONDUIT TABLE
LOCATION
CONDUIT
CABLE
TYPE & SIZE
ASBUILT INFORMATION - FOREMAN COMPLETE
FROM
TO
SIZE
(IN)
SIZE
QTY.
DESIGN
LENGTH
(FT)
BENDSPULL
PULL
{LBS)
REV
(LBS)
CABLE SIZE
DESIGN
LENGTH
(FT)
PHASE - ID TAG
RECORD
RECORD PHASE TAPPED & ACTUAL
FOOTAGE INSTALLED
900
A
B
C
MANUFACTURER
COMPOUND
YEAR
NOTES
CONDUIT
CABLE
J02
J03 (IP3)
4
SCHL 80
1
10
-
279
320
30 1/0 AL JKT
85
EIB701
EIB702
EIB703
I
COAEK276
31 908-166067
CHARGE TO TESP
o 2 SWA 1201208v
J02
J04 (IP2)
4
SCHL 80
1
10
COAC1698
393
298
20 1/0 AL JKT
700
EIB704
EIB706
V02
166066
CHARGE TO TESP
208Y/120
3
J02
V02
4
SCHL 80
1
150
Matid: 6258250
267
232
30 1/0 AL JKT
160
EIB707
EIB708
EIB709
J -Box Below Grade
104 BURNETT AVE S
30 PRIMARY LINE EXTENSIONGas
104 BURNETT AVE S, RENTON, WA 98057
INCIDENT MAOP
N/A N/A
Order Elect Order
N/A 101113708
GE
SCALE72/2
AS NOTED
V03
J02
V03 (IP1)
2
SCHL 80
1
10
122
99
10 1/0 AL JKT
400
EIB705
CHARGE TO TESP
Matid: Existing
J02
Vol
CABLE ONLY
31
31
10 1/0 AL JKT
10
EIB711
EXIST
166059
CHARGE TO TESP
w/4-Pos J -Bus x3
3
J02
JUMPER
CABLE ONLY
2" PVC (FT) & RFNn.q = I n
10 1/0 AL JKT
10
Matid: Existing
EIB710
CHARGE TO TESP
317898
4'8"x7'x5'
4" PVC (FT) & BENDS = 180 1
VAULT & EQUIPMENT TABLE
1/O AL JKT TOTAL (FT) = 1900
TRANSFORMER INSTALLATION
Installed at site: V02
Grid Number: 317948-166066
kVA Rating: 500kVA
Material ID#: 6258250
Foreman to redline the following information
Company ID#:
Primary phase connected to:
Tested Secondary Voltage /
Top View, 12 kV Cable Routing
Cables should enter the vault so that all of
the cables will lay in the same direction.
ADW637
REAL ESTATE/EASEMENT
EASEMENT
TYPE & SIZE
PRIMARY
BUSHINGS
12" Min 12" Min
AS -BUILT INFORMATION
(No rocks over 10" diameter)
AOAEK271
VAULT SIZE &
EQUIPMENT IN
BOAEK272
TRANSFORMER ID
w
LB
DC
SITE #
GRID #
COVER
VAULT
NUMBERS (COMPANY ID)
FOREMAN: INCLUDE PHASE TAPPED
T. MULLENIX
206.305.6912
4'8"x7'x5'
J -Box Below Grade
BY DESCRIPTION
J
N/A
Vol
317902
w/2-3' Sq Doors
w/4-Pos J -Bus x3
1
-
AOUNK �
206.305.6912
EXIST
166060
Matid: Existing
100kVA TUT
317902-166060
I
COAEK276
31 908-166067
75kVA 1201240v
o 2 SWA 1201208v
AOAC1696
Matid: Existing
BOAC1697
OH CKT MAP
2305EO76
I UG CKT MAP
2305EO69
COAC1698
317948
7'x7'x4' w/60"x24"
500kVA 30 PM TRF
JOB SITE
V02
166066
access w/8' Sq Cover
208Y/120
3
-
317881-166065
COAC1692
N/A
3X50kVA 1201240v
Matid: 7917901
Matid: 6258250
BOUNK
317
7-166059
COUNK
N/A N/A N/A N/A
4'8"x7'x5'
J -Box Below Grade
104 BURNETT AVE S
30 PRIMARY LINE EXTENSIONGas
104 BURNETT AVE S, RENTON, WA 98057
INCIDENT MAOP
N/A N/A
Order Elect Order
N/A 101113708
GE
SCALE72/2
AS NOTED
V03
317942
w/2-3' Sq Doors
w/4-Pos J -Bus x3
1
-
EXIST
166061
Matid: Existing
100kVA TUT
Matid: Existing
J01
317877
4'8"x7'x5'
J -Box Below Grade
EXIST
166059
w/2-3' Sq Doors
w/4-Pos J -Bus x3
3
-
Matid: Existing
Matid: Existing
317898
4'8"x7'x5'
J -Box Below Grade
J02
166073
w/2-3' Sq Doors
w/4-Pos J -Bus x4
15
1
Matid: 9996200
Matid: 7625900
J03
317910
4'8"x7'x5'
J -Box Below Grade
EXIST
166066
w/2-3' Sq Doors
w/4-Pos J -Bus x3
3
-
Matid: Existing
Matid: Existing
J04
317965
4'8"x7'x5'
J -Box Below Grade
EXIST
166061
w/2-3' Sq Doors
w/4-Pos J -Bus x3
2
-
Matid: Existing
Matid: Existing
TRANSFORMER INSTALLATION
Installed at site: V02
Grid Number: 317948-166066
kVA Rating: 500kVA
Material ID#: 6258250
Foreman to redline the following information
Company ID#:
Primary phase connected to:
Tested Secondary Voltage /
Top View, 12 kV Cable Routing
Cables should enter the vault so that all of
the cables will lay in the same direction.
ADW637
REAL ESTATE/EASEMENT
EASEMENT
COAFG338
Min\\
12" Min 12" Min
AOAC1699
(No rocks over 10" diameter)
AOAEK271
Separation Separation
DATE
BOAEK272
48" SAA
w
COAEK273
�Ai
Q
9.17.18
1
07
ENGR - POWER
T. MULLENIX
206.305.6912
10.23.18
REV# DATE
BY DESCRIPTION
J
N/A
N/A
_J
COUNTY
N/A
Emer Sect as Wk Ctr
N/A N/A
IPOWER WK CTR
N/A
317910-166 66
AOUNK �
206.305.6912
AOAEK274
CHECKED BY
I1 j�3
BOAEK275
317902-166060
I
COAEK276
31 908-166067
75kVA 1201240v
o 2 SWA 1201208v
AOAC1696
FOREMAN #1
BOAC1697
OH CKT MAP
2305EO76
I UG CKT MAP
2305EO69
COAC1698
FOREMAN #2
JOB SITE
317884-1
AOAC1690
100kVA 12
BOAC1691
UTILITIES
317881-166065
COAC1692
N/A
3X50kVA 1201240v
CONTACT
PHONE#
BOUNK
317
7-166059
COUNK
N/A N/A N/A N/A
AOUNK
J
104 BURNETT AVE S
30 PRIMARY LINE EXTENSIONGas
104 BURNETT AVE S, RENTON, WA 98057
UNDERGROUND CIRCUIT MAP
SCALE: 6" = 1 MILE
CURB OR EDGE OF PAVEMENT
5'
MIN
3'
�- MIN
I
COOLING
FINS
REQUIRED
WORK SPACE
AREA
5' MIN
3' MIN
TYP. PAD
& TRANS-
FORMER
3' MIN
5' MIN
5' MIN
=1= �-■ — ACCESS
DOOR
`�-- 10' MIN -
— — �-� -- ACCESS
—� DOOR
CONCRETE PAD
__7
Trench and backfill requirements for primary electric line extension trenches (No PSE gas)
- A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter.
- A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter.
Excavated Dirt Pile
ROADSIDE 32" Typical
(Power, Gas, and 24" Min
Final Grade Communications)
\\ii\\ii\\ice\\i/\,
\12" Min
\i Separation
36"
REAL ESTATE/EASEMENT
EASEMENT
Backfill
Min\\
12" Min 12" Min
(No rocks over 10" diameter)
Cover
i
Separation Separation
DATE
2
48" SAA
PROJECT MGR
�Ai
Max\\—
9.17.18
1
6" or 12" Min Sand Shading after Compaction
4" Sand Bedding
Gas -J I- Primary Power
Communications Cables or Conduit
JOINT TRENCH DETAIL
Primary -Mainline Gas & Communications (NTS)
CUSTOMER -SUPPLIED TRENCH FOR PRIMARY CABLE
SCALE: NONE
Excavated Dirt Pile
20" Min 24" Min
Final Grade To Excavated Dirt Pile
24 Min Backfill for Conduit
to Free of rocks
ROAD OR 36" Max // /� larger than 8"
\/ 12" Min
PARKING AREA Cover �/\ Separation //j in diameter)
I
CURB OR EDGE OF PAVEMENT -I"-
MINIMUM
"-MINIMUM CLEARANCES FOR PSE EQUIPMENT
Not to scale
lJ
FLOW DIRECTION
LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL,
SECURE WITH PEA GRAVEL BAGS (MID 9995692).
TECHNIQUES FOR EROSION AND SEDIMENT CONTROL
SILT FENCE DETAIL
Not to Scale 0150.3200
ROAD SIDE (PREFERRED)
3' MIN
0 0
31 ® 3'
MIN MIN
6' MIN
FIELD SIDE (PREFERRED)
CLEAR WORKING SPACE FOR VAULTS
NOT TO SCALE
6775.0035
3'
8"
— — 1— ��� 36" MINIMUM COVER
�� IN RIGHT OF WAY
TV & TEL - / Electric Service Cable in Conduit
3" Schedule 40 Grey PVC
JOINT TRENCH DETAIL
0
LO
PRIMARY SPLIT
Electric Service Cable in Conduit (NTS)
i=XICTInIr' I Ir DDIRAARY
SPLICE PIT DETAIL
4'-0"
;Y
SCALE: NONE
REAL ESTATE/EASEMENT
EASEMENT
PERMIT
RENTON
3
FUNCTION
CONTACT
PHONE NO
DATE
2
PROJECT MGR
VAL BUZUNOV
425-457-9938
9.17.18
1
ENGR - POWER
T. MULLENIX
206.305.6912
10.23.18
REV# DATE
BY DESCRIPTION
ENGR - GAS
N/A
N/A
N/A
COUNTY
N/A
Emer Sect as Wk Ctr
N/A N/A
IPOWER WK CTR
N/A
DRAWN BY
MULLENIX
206.305.6912
10.23.18
CHECKED BY
I1 j�3
1/4 SEC
N/A
OP MAP
N/A
I
PLAT MAP
N/A
APPROVED BY
,� J
II fk
FOREMAN #1
U -MAP NO (POWER)
2305EO69
OH CKT MAP
2305EO76
I UG CKT MAP
2305EO69
CIRCUIT NO
N/A
FOREMAN #2
MAPPING
JOINT FACILITIES ARRANGEMENTS
UTILITIES
N/A
N/A
N/A
N/A
CONTACT
PHONE#
N/A
N/A
N/A
N/A
N/A N/A N/A N/A
PU/ GE r`rT
SOUND
ENERGY
104 BURNETT AVE S
30 PRIMARY LINE EXTENSIONGas
104 BURNETT AVE S, RENTON, WA 98057
INCIDENT MAOP
N/A N/A
Order Elect Order
N/A 101113708
GE
SCALE72/2
AS NOTED