Loading...
HomeMy WebLinkAboutR-398008Z N (0 T W co M - S1° 31 39.44„W!I 114TH AVE SE STA +00 = SE 162ND STA 10+00 CONIC MONUMENT W/ BRASS - N 170084.65 9 - E 1305087.02 ° a a a ° J Jj �r-9z�0) Cn Oj O ZNN �I� ° O o O =1 c�i�CDC-O �z00z ° Q ill Q STA 21 +51.68, 13.00' LT m L 16 IDE DRIVEWAY z0-) SEE SHEET C5 FOR O ( ONSITE UTILITY PLANS W O I� O U� N �0 1 LINE (TYP) J 1 RIQIECT EX UTILITY POLE � 4' WIDE ACP LANDING 1 SLOPE AT 2.0% MAX ACP RAMP, SLOPE AT 12• -T MAX, MATCH EX GRADE \ CB #5 1 3 1 „ D 0 00 E- Ir2�-e�m ! m _ !m j FILL AND GRADE TO DRAIN ! ELEC CABINET, ! I SEE LIGHTING PLANS 1 �2+00#6 i rn m STA 21 +79.12, 13.00' LT END CURB AND GUTTER AND PROJECT SIDEWALK STArr'k1f77.12. 42.24' LT 1 1 1 1 1 1 J m ' .......... _ N ...... Lin 1 . . . . . . . . . . CV cV W CV �_ 485 ..........,. .......... ; p w ....... c w ...... a' w w o . . . . . . ..EX CENTERLINE i �� L + p� o��___ _r + C68+ rnp a; 060-) r- �p rn cflr7 GRADE ! p. 00 00 � a EX GRADE AT ROADWAY N co s N ¢ Q � 4 � + w N � + m N c� � � CO� REMOVE EX 12"1 1 c~i� U iY !�' CENTERLINE PROPOSED TOP OF CURB ELEVATION cn m i� LEI 00 z E w � CULVERT Ln w 1. 480 ............ ............... 1 FILL AND GRADE - 1 - . -030% �� TO DRAIN 45 LF 12" DI SD 1.0% Q EX - - ........... - .... - �q� .: - - - - i m O ............................................................. 6"SS, FIELD VERIFY ELEVATION ......�. ..... ... ..... .. ........' rn ...... . ................. PRIOR TO CONSTRUCTION � .. �:..-.- ._ — 14 LF �, — ------ 1(A 475 ... .- • % L12 FIELD VERIFY ELEVATION OF EX 8" I .......... 1 ITI WATER MAIN PRIOR TO CONSTRUCTION I m TO ENSURE 6" CLEARANCE FROM 470 PROPOSED 12" SD, NOTIFY ENGINEER OF POTENTIAL CONFLICTS EX 6" SS, FIELD VERIFY ELEVATION ... .. 1 - o PRIOR TO CONSTRUCTION 0 - U o p W SAME STRUCTURE CB 6 1 cn z �-' SAME STRUCTURE CB #5 1 465 � �, p ,� O 475 1 �w a_ 1 g1 - +mo,� N C.� 1. 460 00 470 15 LF 12'' L" � � w SD 2.00% O i STA 21 +93.00, 17.5' LT 1 48" CB #6 TYPE 2 W/ SOLID LID ! 455 RIM 479.15 1 IE 473.73(N), 469.93(SE), 476.55(8" NE) 1 M0) C�o OOr?CR co 1`-�N!n C�o co CO Lnpr 00 LgpcV 00 m 00 m 00 m 00 m 06 O 00 ai 450 ��� mF-m ��� mom c)�� mom ��� mom ��� mom ��� mom 20+00 20+50 21+00 21+50 22+00 Know what's below. Call before you dig. co.:,erra ENGINEERING PLLC 321 3rd Ave South, Suite 307 Seattle, Washington 98104 ph 206.596.7115 coterraengineering.com 114TH AVE SE PROFILE SCALE: HORZ. 1 " = 10' VERT. 1 " = 5' 7 SHARED DRIVEWAYS 6 CITY COMMENTS 5 CITY COMMENTS 4 CITY COMMENTS NO. REVISION SURVEYED: MB 3 29 17 PA DESIGNED: MB MB 9 09 16 PA MB 8 15 16 PA DRAWN: MB MB 7 07 16 PA CHECKED: PA BY I DATE I AP P R APPROVED: SCALE: 1 a_ 10, HORIZONTAL: N D 11983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Egm 2N 475 NOTES 1. SEE SHEET C1, C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS. 2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13. 3. SEE SHEET C11 FOR ROADWAY SECTIONS. 4. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS. 5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND ASSUMED CONFIGURATION. THE CONTRACTOR SHALL UNCOVER ALL PIPING WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL ADJUST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED CLEARANCES. 6. COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS IS MAINTAINED AS REQUIRED. 7. PROTECT UTILITIES TO REMAIN. 8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO CURRENT CITY OF RENTON STANDARDS. 9. THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATE PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THE EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6: 1. MAX. LEGEND -- 1 CB TYPE-1 C14 \� CB TYPE-2 48" C 14 - - - - - - - STORM DRAIN MAIN SANITARY SEWER MAIN SANITARY SERVICE LINE — WATER SERVICE LINE WATER/FIRE MAIN ASPHALT CONIC PAVEMENT 470 CEM. CONC. PAVEMENT 465 PERVIOUS 3 CONCRETE C 15 460 SIDEWALK 455 - - - - - - - - SAWCUT LINE IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATER UTILITY DEVELOPMENT ENGINEERINGn,77 rstraka 06/20/2017 'rianne B Bannwarth 06/22/2017 CONSTRUCTION PERMIT SUBMITTAL DATE: n �% CITY OF L I M E L I T E SHORT PLAT FlELD3/29/17 IMU REN TON 16204 114TH AVE SE, RENTON, WA 98055 PAGE: Planning/Building/Public Works Dept. DRAWING NO: FRONTAGE IMPROVEMENTS 114TH AVE SE R-398008