Loading...
HomeMy WebLinkAboutAB-3980REFER TO SHEETS C6- FOR FRONTAGE DRAINAGE IMFR6�E� ENTS ugD .40 f � t.f100 40 I — — — — , 00 40 is + I 1 1 � 1 1 1 REFER TO SODS CREEK SANITARY SEWER PLANS FOR SIDE SEWER AND SEWER MAIN EXTENSION PLANS L- I PROTECT - EX IT ]TY POLE TO RE AIN I - —SE 162ND ST - 1 I UJ I I 1 � 1= � I Know what's be I ow. Call before you dia. it � I RY TERRANE, INC. DF 'A SURVEY CONDUCTED 1. LOT � I I l — RIM 480,4c RIM=480,19 - _- : FI+I FUTURE STUB FOR FUTURE IE 477-57 IE=477,54 I -_ _ _�ONINECT1ON BLDG. CONNECTION '-� ' IE 478.45 - ] 16 LF 8" SID f f 1 F' •` / .J r f %I I PROPERTY LIFE �., R M *8036 RIM=480,47 jfJJ r` IF 477-25 RIM=477,32 I L I 1 1 I p.1 I � I SHARED UTILITY J 1 EASEMENT (TYP) I fT6 I I Ri��.�a IF 476.45 IE=476,45 _ _ _ -�- -� f r 4T-eI+-BASIN TYPE I I I - —CATCH BASIN TYPE 1 RIM=479,98 1- STUB FOR FUTURE f � I _ -= IE_ � IE S=476,83 - � �� RIM r.� RIM=4818,04 _eiD.-crNT�oI _ IE N&E-47�9-3 - IE IE 47 f r I IE 476,81 - �i ■i-.--.-- -.--Si LF 8r5D -- -- -- - _ _ -� - SD MANHOLE 54" Vd/ ! - LOW. CONTROL STPI_ICTURE PRIVATE I; �I �_ RIM.-479,5..5: UNDERGROUND DETENTION (FACILITY( I_ -, �, = — - - I� $ 5 �LQI,4MET _.1Kd MLO SYSTEM 1 c� ? ll - IF 78" 469.32 l (6" DEAD STOIRZE ^ ' Sn T Afi0.81 ii12" ��2 �69,97 1E 419.11 �3.1" E, 1N) 36" E=469,�� F ---------1P I ` I: I=-- ------------__.----------- m DOMESTIC SERVICE CONNECTION PER SOiOS CREEK STANDARD PLANS. CONFIRM ME -ER AND SERVICE SIZING WITH PLIJOI dG DESIGNER (TYW-f NP VU-88 — 6"'_SS_ S7iJB, SEE _c=S CRE1=lC _SANITARY SEINER PLANS (TAP) - I ECORD DRAWING F'ORMATION ADDEI E (RESENT RESUL S I�OT 2 vULY1 2018 gLDG. CONNECTION IF 477.69 f I I f I 13448 N 4804F 3" SID 1 •f' SHARED 1-1-1. Irl 1 EASEMENT (TYF)LLOT: 1 I DETENTION ACCESS WATER SERVICE ,r i I RISER (TYP) (TYP) � f` 20 LF 8" SID STUB FOR FUTURE BLDC, r .--.-- CONNECTION •I I IE 475 39 f / - - - - - - - - _ — — — — r� _ .14 WAT SERVICE TYP) . �— -� — ��' � ---- -- � -- 479.25 CATCH BA:�IN TYPE 1 CD TYPE 1 SWALE r° 1 - . f RIM� ;. _ , -: _ 1.�1 �..�� . �-� 1_,] -- RIM �86-8D RIM=480,94 _ IE 47s.7 I..: L IF IE=477,84 coicerra ENGINEERING PLLC 321 3rd Ave South, Suite 307 Seattle, Washington 98104 ph 206-596,7115 cote rraenglneering.com IS7 _�_UZIA4 7 SHARED DRIVEWAYS 6 CiTY COMMENTS 5 CfTY COMMENTS 4 CITY COMMENTS %(). I REVISION. 3U�iC•1 i,[ mB 3 2 17 PA ;=S,CNEC. MB MAD 9 09 1 B PA M E3 8 15 16 PA meMB 47 1 PA .•..LC[iEG. I _. ; I .. 1. 1 API p I APPROVED. SME- 1 "=10' ONE INµ eT FULL Fi ALE IF NOT ONE .WCFF SCAUk A,CCOROINGL` LERi1CAL fuVO 19M HOWZWAL, NAD 9?h3fl931 DATIJ M IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Brianne Bannwarth 06122/2017 SURFACE WATER UTILITY rstraka 06/20I2017 CURRENT PLANNING i mdavis 06120/2017 NOTES 1. SEE SHEET CI AND C2 FOR GENERAL NOTES, GENERAL STORMWA•rER NOTES, AND GENERAL SANITARY SEWER NOTES, 2. ALL ROOF DGWNSPOUT CONNECTIONS TO THE FUTURE BUILDING STUB OUTS ]HALL BE PERFORATE] PIPE. MAINTAIN 5' MIN, SEPARATION FROM BUILDING. 3. ALL WORK SHALL BE IN ACCORDANCE WFrH CITY OF RENTON AND SODS CREEK SEWER AND 'HATER STANDARDS AND REQUIREMENTS. 4. SEE 5005 CREEK SEWER PLANS FOR SANITARY SEWER MAIN WORT{ AND 51DE SEWER STU195 WITHIN THE RIGHT -OP -WAY. 5- VERIFY SIZE OF NEW WATER METER AND SERVICES WITH PLUMBING DESIGNER AT TIME OF BUILDING PERMIT. $. CC1ORDINATE METER [INSTALLATION WITH BUILDING PERMIT. PROVIDE 18" MIN. COVER OVER DOMESTIC WATER SERVICE. (DOMESTIC WATER SERVICES SHOWN FOR INFORMATION ONLY.) LEGEND ❑ ■TYPE-1 1 CB TYPt� 1 DETENTION TANK MAINTENANCE ACCESS 213 TYPE-? 48" �• 1 � - - - , - STORM DRAIN MAIN STORM DRAIN SERVICE ■.. SANITARY SEWER MAIN: • • SANITARY SERVICE LINE 0 CLEAN OUT WATER SERVICE LINE WATER/FIRE MAIN - SWALE 1 WATER METER ASPHALT CONC PAVEMENT � G15 TABLE OF DRAINAGE AREAS TOTAL LOT AREA MAX IMPERV BY 704ING REDUCED MAX IMPERV REDUCTION 1N IMPERV LOT 1 5,039 3,779 2,728 1 1,0.52 LOT 2 5,032 3,774 2,724 1,050 LOT 3 5,940 4,455 3,215 1,240 LOT 4 8.834 5.625 41782 1.843 LOT 5 5,065 3,799 2,742 1,057 (ALL AREAS IN SF) TOTAL FLOW CONTROL BMP IMPERVIOUS AREA CREDIT 1,052 1,050 785 0 1,057 3,943 CONSTRUCTION PERMF SUBM TTAL DAYEL CI /29/17 TY OF LIMELITE SHORT PLAT u, FIE1Ad��K. RENTON 18204 114TH AVE SE, RENTON, DIVA 98055 �r- ¢R"ING NO: Planning/Building/Public Works Dept. D NA AND LMLTY PLAN I 45 SKF7: OF: �i 0 N SE 162N D ST STA 1 Q+t3 = 1-WH 'APSE STA--0+ CONIC MONUMENT W1 BRASS DISC N 170084.65 = E 1305087.02 S88' 29' 38-90" E 10+50 RIM=480.2 LiJ ch rr NAVD 8 8 CONLLJ TRACTOR SHALL COMPLY WITH THE CITY OF Q CD w � � RENTON 5 TRENCH RESTORATION AND STREET ~ OVERLAY REQUIREMENTS. W � E: LLJ = Lv 1 o - - - - - - - _ :2 4 , 00 C - _ - - - r E SEE SODS CREEK SEWER MAIN - - G� - - Lj I o + - o¢o PLANS FOR SANITARY SEWER { : ` a o i 1 +QQ IMPROVEMENTS- (TYP) w 12'IE SW&E=4j7,54 _ - - 11+,)a T Ez ' ` 121+00 { STA 10+37.99, 13.00' RT CB 8 PERVIOUS CONCRETE SIDEWALK ! . - -� - SAWCUT LINEADA RAMP r -114,2 LF- @1,58% 12, 5D f = f '1 40 — - - r # - - - V M=482,10 STA 10+37.99: • 38-W - CO f STA 10+12.99, 37.99' RT � PC - 0 Me m 475 470 CMel tz� �I—I N N c� t,-j r� + + � v + �, CIL r C ca un r' li o Wm M EL Ln Vn c� w V� CIL Ln CB #9 12+50 483.43t(E) �. �ff-�— . RIM=483.43 - - -- y EL CHK , 48297 61k(� 30 31 1100' RT 482.901(E) ENO C 'AND GUTTER GRA E 2.1 MAX & l MATCA fX E}ITCH -GRADE-S ----_ - -w �.._ .#_ If ¢P3..7F 4'X5'X12-' THICK RIP RAP ACP RAMP, SLOPE AT 12:1 1 — _ . -� MAA, M1> I k H EX UMADE RECORD,PRAWINGI r][, �. � - _ ,� � � � . � ..�-- _ - - 4' WIDE ACP LANDING WAS1 `SLOPE AT 2.0% MAX G INFORMATION -ADD D BY TERRANE, INC. STA 1�+30.31, 24QQ' RT ENI) kEWALK - Id 15025 � , ; SENTS THE RESU TS OF SURVEY CONDUCTED I JULY, 2018 �SZ �GISTLR� �a ANAL LA�� r 1-79% SEE SHEET C8 FOR SD PROFILE SEE SHEET SS1 FOR SODS CREEK SEWER EXTENSION PLANS O O d- co -4- ¢ mom 10+50 EX TOP OF CURB ELEVATION O f- PROPOSED TOP OF CURB ELEVATION Eli GRADE AT ROADWAY CENTERLINE �.oDoL-� � re) 0� LID � � N LQ O ry Cv 00. ; X� [r,- Q0 � mf--m ❑7 m m m m m 11+00 11+ 0 SE 162ND ST PROFILE SCALE; HOR2. 1 " = 10' VERT. 1 " = 5' CURB RETURN TABLE NO. ❑ R STA PC LOCATION TOP OF CURB ELEVATION STA PT LOCATION PC 1 1 4 1 1 2 1 3 4 1 PT 89'58'41.7" 25' 10+12.99, 37,99' RT 479.55 48114 480.09 480.57 480.74 10+37.99, 13,00' RT Know what's below. Call before you dig. coterra ENGINEERING PLLC 321 3rd Ave South, Suite 307 Seattle, Washington 95104 ph 206,596,7115 cote rra en g i neeri n g. c o m NOTES m I� m 1- SEE SHEET C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS- 2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5%C 13. 3, SEE SHEET C7 FOR ROADWAY SECTIONS. 4, ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BUONO THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS. surrvvErEn, 7 SHARED DRIVEWAYS MB '{ 32917 PA .&CNED: �B 6 CITY COMMENTS MB 9 0916 PA 5 CITY COMMENTS MB 8 15 16 PA MA'N: Lis 4 CITY COMMENTS I M13 17/07/161 PA CHECKED, PA i::' REVISION BY I DATE I APPR APPROVED: LEGEND Am-1 I��� 1 I CB TYPE-1 C14 CB TYPE-7 48" - C14 — — — — — — — STORM DRAIN MAIN SANITARY SEWER MAIN SANITARY SERVICE LINE — — — WATER SERVICE LINE WATER/FIRE MAIN CURB & GUTTER G1 ASPHALT CONIC f PAVEMENT 1 w 495 CEM. CONIC, PAVEMENT 490 o o o rn LE CT)T "] Op N W + co co PERVIOUS 3 r u li CONCRETE < __j SIDEWALK 1 LLJ J ��w 485 1-I}7 SAWCUT LINE 175 PROP. F.G. CONTOUR 21 LF 12" SD 1,19% — — 480 N WATER VALVE I,--480.65 ' PIPE OUTLET 475 m1� 12+00 10c) co Ln co r'} Do 0:D mom 5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND ASSUMED CONFIGURATION. THE CONTRACTOR SHALL UNCOVER ALL PIPING WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL ADJUST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED CLEARANCES- 6 cDaRDIKIATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACOE55 IS MAINTAINED AS 470 465 12+50 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATER UTILITY DEVELOPMENT ENGINEERING rstraka 06120/2017 Brianne Sannwarlli 0612212017 CURRENT PLANNING mdavis 06/20/2017 REQUIRED- 7, PROTECT UTILITIES TO REMAIN. 8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO CURRENT CITY OF RENTON STANDARDS. CONS 1 uc 1 1 PERMIT �AL SCALE: 1 1 PERMIT GATE: VERTICAL: NAV➢ 1988 1"-10' HORIZOWAL: Hap 1ya3/19s1 CITY OF L I ELITE SHORT PLAT 3 2.91 19 FIEuDGODK. ry RENTON 16204 114TH AVE SE, RENTON, I#A 98055 PAGE, ONE INCH V TI i Ffg)WAGE IMPROVEMENTS TS GRiWING N4; AT FULL SCALE L7 Panning/Building/Public Works Qept. C6 IF NOT ONE INCH �a+� J w w SCALE ACCORDINGLY w 162ND SHEET- OF GR4 p� WASFlj ®d7 W 15025 s �EGIS1�✓R�� � TONAL L CE:111 475 470 465 e D D EMMOW7 x 1 4,:ir•;IRt'lC f�N SHALL COMPLY WITH THE 0FV OF RENTON'S TRENCH RESTORATION ARID STREET 1 OVERLAY REQUIREMENTS. 1 NAVD�88 ROW LINE (TYP) 1 PROTECT Ex WATER -~ "� � �� • - _.� 1 1 - —1 REMOVE EX 12" — C8 #4 ; 1 - - - - - - - - - - - CU LVERT 1 12" E D }• C` Q ' � i l _ � 1 ` I ✓� � l � _ I � _ ! � I " .}� — — — — � — — 1 L'] 1 RESTORE EEC SURFACES �:RESTORE EX - SURFACES (TYP) PROTECT EX WASTER 1 -� W _ FILL AND GRADE TO � SAWCLIT LINE W; DRAIN FILL AND GRADE TO - IT — - -- T `24-50 � FILL AND GRADE TO - IT — 23fD� D _3�-7C DRAB REMOCULVVE EX 12' ' co RT Wj 1 W- RECORD DRAWI r c; ;m 1 1 INFORMATION A DD B E R A E11 o REPRESENTS THE RESULTS OF A SURVEY CONDUCTED IN 1 1 JULY1 2018 1 1 �1 1 1 1 1 1 1 1 1 OD W W W W W; 1 1 1 1 1 1 1 1 22+50 1 1 Know what's below. Cal before you dig. coterra ENGINEERING PLLC 321 3rd Ave South, Suite 307 Seattle. Washington 98104 ph 206.596.7115 c otelrrae ng i nee r i n g. com NO CONFLICT WITH PROPOSED 12" SD 23+00 CONSTRUCTION TO CONFIRM NO CONFLICT WITH PROPOSED 12" SD U-)o 00 00 � II II �cl- W (W �I �i/ \U 23+50 114TH AVE SE PROFILE SCAI..E: HDRZ_ I.. - 10' VERT. I" = 24+00 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATER LITIL.ITY rFR straka 06/20/2017 DEVELOPMENT ENGINEERING 11 13rianne 13annwarth 0612212017 1 1 1 1 1 1 1 1 1 �M IM �co Im iM 1� 1� 10 1 1 1 1 1 1 1 1 1 24+50 ' )EE SHEET C 1, C2 & C 12 FOR GENERAL NOTES AND ROADWAY DETAILS. 2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13 3. SEE SHEET C1 1 FOR ROADWAY SECTIONS. 4. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF TI4E CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL EXISTING INFORMATION AND TO FURTHER, DISCOVER AND AVOID ANY OTHER UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS. 5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND ASSUMED CONFIGURATION. T14E CONTRACTOR SHALL UNCOVER ALL PIPING WHERE CROSSING, INTERFERENCES. OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE TH APPROPRIATE PROVISION FOR PROTECTION OF SMD FACILITIES AND SHALL ADJLIS7 WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED. CLEARANCES. 6. COORDINATE ALL WORk WITH CITY OF RENTON TO ENSURE FACILITY ACCESS IS MAINTAINED AS REQUIRED. 7. PROTECT UTILITIES TO REMAIN. 8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO CURRENT CITY OF PENTON STANDARDS. 9. THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATE PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THi EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6:1. MAX. .111111=1W =121W 1 CB TYPE-1 14 ry k. I CB TYPE-2 48" 14 — — • — — — - STORM DRAIN MAIN [A!00] SANITARY SE4')ER MAIN SANITARY SERVICE LIME 475 — — WATER SERVICE LINE WATER/FIRE MAIN 470 FIRE HYDRANT CONC THRUST BLOCKING HORl2 455 WATER TEE WATER METER '�S 3 460 ASPHALT CONIC PAVEMENT CEM_ CONC. PAVEMENT PERVIOUS 3 CONCRETE 1 SIDEWALK CONSTRUCTION PERMF SUBM TTAL 5URVF1En: 5cn4E: 7ti 3/29/17 V III 1 140RIi0NTA: NAO T9-n/1%A1 r�i6B0 - � Q 4ERilCAt NAVQ 1986 7 SHARED DRIVEWAYS MB 3� 17 PA OESIGNEn: �CITY O� L I M E L I T E SHORT PLAT CITY COMMENTS+B 16 4B ha RENTON 16204 114TH AVE SE, RENTON, WA 98055 W-L 5 CITY COMMENTS MB 8 15 1fi PA °R'"'N A 1'1� �g ONE INCH � QATUIV4 IRANINC N6 # CITY COMMENTS BV 177 ,s APA CN•C1 E� IF PA WFULL ,7 ONEN CH Planning fBu�Iding/Public Wc,rks Dept. FRONTAGE IMPROVEMENTS 114TH AVE ME C9 NO. REVISION 3 1 DA I L API FR 4PPRO-1. 5CAlE ACCOREANIGLY 5nf� Of' RErmORD DRAWINI CONTRACTOR SHALL COMPLY WITH THE CITY Of ; NAVD-88 RENTON'S TRENCH RESTORATION AND STREET OVERLAY REQUIREMENTS. ROW LINE (TYP) FILL AREA GRADE TO DRAIN— GD #3 CO #2 FILL AREA GRADE TO DRAIN Wi�m Liiiiiiiiii i t 12" SID ADDITIONAL -CB � i 12" S D r l i i r i i r i i i iFQj REMOVE EX 12 CULVERT SAWGUT LINE 50 RESTORE EX 'SURFACES (TYP) . GR - RC: D DRAWING _ _ - 26+DO OV WASk��_�1. INFORMATION ADDED BY TERRANE, INC. W ! REPRESENTS THE RESULTS OF A SURVEY CONDUCTE D IN JULY, 2018 15025 WLLA"SN'. Uj 1 1 1 1 1 I ' u 1 Li ' 480 — u w cu 1 T CO �.D 1 �W 475 1, 1 FILL AND GRADE TO DRAIN (TYP) r LJ- W 470 Z - V 13QLF t2`' SD 0 547. 1 W1- EX 6" SS, FIELD VERIFY ELEVATION 465 1 PRIOR TO CMSTRUCTION TO CONFIRM W 1 NO CONFLICT WITH PROPIDSED 72" SID 1 1 1 460 1 1 1 24+50 Know what's below. Call before you dig. S" TOPSOLL,- HYDROSEED OR SOD (TYP} FILL (TYP) Ex 8" w EX 8" 55 f 25+00 coterra ENGINEERING PLLC 321 3rd Ave South, Suite 307 Seattle. Washington 98104 ph 206.596.7115 c oterrae ng i nee r i n g. com ILL] rL Lu J m rti ,D `D LLJ � . ��- EX CENTERLINE GRADE LiJ REMOVE EX 12" CULVERT 99LF@0,64% ............. 54LF@0,63% Ex 6" SS. FIELD v-RIFY - ELEATIGN PRIOR TO CONSTRUCTION T 0 CONFIRM NO EX E," 55, FIELD VERIFY ELEVATION CONFLICT WITH PROPOSED 12" SO PRIOR TO CONSTRUCTION TO CONFIRM NO CONFLICT WITH PROPOSED. 12" SD 475 470 465 25+50 114TH AVE SE PROFILE 4 WA i Ao SCALE: HORZ. I" = 10' VERT. 1" = 5 7 SHARED DRIVEWAYS 6 CITY COMMENTS 5 CITY COMMENTS CITY COMMENTS TONAL ' lVd. REVISION 00 Ln Ln 't Im m01) r, - r- kD `D `D "t Pq 0- � U LLJ — � 00 LLJ 0- a_ U t1 U Z U ^- l V Q II Z 0 LLJ Q Q H Q!� I —I I —I H FILL AND CRADE TO DRAT (TYP) SAME STRUCTI.IRE CB #1 REMOVE EX INLET E21;'v1 472.59 IE 12" CPEP N 470.26 IE 12" CPEP E 470.24 CE 12" CPEP W 469.84 I 1 I � I I I L I 26+50 26+56 I 1 I 1 I � �1 I RESTORE PAVEMENT I �1 I MAR1 INGS (TYP) I I � 1 I 1 I I I I 1 1 I 1 ti I CONNECT TO Ex CI3 I 3 O O � O o ZL CU x R w J O Ln CD cn rn � M1I� f 0 8LF@9,281 FIELD VERIFY ELEVATION OF EX 8" WATER MAIM PRIOR TO CONSTRUCTION AND NOTIfY r-NGINEER CIF PQ I LN I IAL CONFLICTS 66 LF 12" SD 1,00% 67LF@ 0.4 CONNECT TO EX CB IE 467.06 26+00 SE 164TH ST STORM PROFILE 26+50 SVRVFrE CI: MB 2917 PA DESIGNED' MID MB U9 16 PA p9 U PA DR 'wrl MIR {■�� MB 71,6 /1 C6 f M! 1Sl PA Cr+3 d�E7 f?A BY LATE A APP R APR?1EE ':/ 475 470 465 475 470 465 LEGEND ❑� CB TYPE-1 1 013 7YPE-2 48" C1� - — — — — — - STORM DRAIN MAIN SANITARY SEWER MAIN aft now + SANITARY SERVICE LINE • — WATER SERVICE LINE WATER/FIRE MAIN FIRE HYDRANT CONC THRUST BLOCKING HORIZ WATER TEE 1 WATER METER r r. (VOTES I. SEE SHEET C 1, C2 k C 12 FOR GENERAL NOTES AND ROADWAY DETAILS. 2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/013. 3. SEE SHEET C11 FOR ROADWAY SECTIONS. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSJBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS. 5. CROSSING UTILITIES ARE SHOWN( IN THEIR APPROXIMATE LOCATION AND ASSUMED CONFIGURATION. THE CONTRACTOR' SHALL UNCOVER ALL PIPING WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE ACTUAL LOCATIONS, SIZE, AND (MATERIAL. THE CONTRACTOR SHALL MAKE THE APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL ABJU'ST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED CLEARANCES. 6 COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS IS MAINTAINED AS REQUIRED. ;. PROTECT UTILITIES TO REMAIN. 8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO CURRENT CITY OF RENTON STANDARDS. 9 THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATF PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THE; EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6-.1- MAX. IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATF-R UTILITY rstraka 06/20/2017 DEVELOPMENT ENGINEERING _,,,_ Brianne Banmarth 06122l2017 CONSTRUCTnON PERMIT SUBMITTAL SCASE: 7AT 4ERiW- ND ,��s 3/29/17 1"=10" Ht,Rl28FlTlk N0,9@S„ , CITY O� LIMELITE SHORT PLAT RENTON 16204 114TH AVE SE, RENTON, WA 98055 94E INCH1 1t1 ERA'h,NG Na I�AT V I� AT FULL P anningfBuifding/Public Works Dept. FRONTAGE IMPROVEMENTS 114TH AVE SE C10 IF NO"f ONE 1NCH INC SCALE ACCOREIN Y U D DRAWING FACTORY FABRICATED WELDED MANIFOLD END SECTIONS (TYR). PROVIDE LAYOUT PLAN SHOWING JOINT LOCATIONS AS PART OF SUBMITTALS FOR ENGINEER APPROVAL, 6" PERFORATED UNDERDRAIN, PRnVIDE CLEANOLITS AT ALL 90' BENDS AND EVERY 75 FT (a 54" DIA. CONTROL STRUCTURE 36" DIA. STORM PIPE CONNECTING WELDED STUB IE 469.81 CONNECT TO CB WITH WATER TIGHT CONNECTION $" SD INLET If 475.00 SEE PLAN FOR TIGHTLINE DISCHARGE OF SUBSURFACE DRAIN PIPE 475 jti urn. CONTROL 1 STRUCTURE FLEVATION NAVD-88 REMOVABLE WATERTIGHT CDUPLING OR FLANGE JOT VERIFIED NOTE: CONTRACTOR SHALL PROVIDE LAYOUT PLAN, BOUYANCY CALCULATIONS AND FOUNDATION PLAN TO COUNTERACT BOUYANCY AS REQUIRED. PROVIDE A MINIMUM 236 LF OF DETENTION PIPE. 7554 CF. DETENTION PIPE AND ALL STRUCTURES SHALL MEET CITY OF RENTON STANDARDS AND SPECIFICATIONS, 36" ACCE' RISER 480 °a SACKFILL PER as o- = �° o° 475 ° DETAIL-5 4° ..... °0° °�.° moo... SHEET C13 .o 00 a BEDDINO PER 0 o0 00 0 5' DEAD STORAO 0c DETAIL:5 SHEET c�3 . IDID 0 0 0 40 00 0 470 _..._.�._yy. p- 0 0 0 0 0 a 0 4 3 PER RA fi" PERFORATED TRENCH . - 78' DIA. STORM PIPE ALUMINIZED CMP OR- APPROVEb 5 6" PERFORATED 465 A IJ" R :16 BOTTOM 468.5M EQUAL (TYP) C16 UNDERDRAIN SECTION A fo"i\DETENTION TANK RECORD DRAWING\u'/ '""°"„"°"k INFORMATION ADDED BY TERRANE, INC. REPRESENTS THE RESULTS OF A SURVEY CONDUCTED 16 RISER PIPE IN JULY, 2018 z jj� S2 Ij Ln cG. ►w T /"'�Drslav MATCH CURVATURE OF PIPE HOLE DRILLED AT TIME OF ASSEMBLE o' LADDER BASE PLATE NTS 0.25" I 1 � TOP PLAT � SUPPORTS Xj2 R29.75" RnTT❑M PLATE SUPPORTS TO HAVE A Y4" X } " CURVE: FOR TOP PLATE TO REST ON. NOTES: 1, HDPE OR PP SHEET STOCK, �" THICK CNC. 2. WELD TO BOTTOM OF PIPE, BOLT HOLE TO BE HAND DRILLED AT FAB PLANT, 3, TRIM BASE PLATE AS NEEDED. coterra ENGINEERING PLLC 321 3rd Ave South, Suite 307 Seattle, Washington 98104 ph 206596.7115 c oterraeng i n ee r i n g. co m 24" ROUND LOCKING FRAME AND COWER MARKED "DRAM" MOUNTED OVER 24" DIA. ECCENTRIC OPENING PRECAST 60" DIA_ MANHOLE TOP SLAB WITH 24" DIA. ECCENTRIC OPENING 78" DETENTION PIPE ALUMINIZED CMP MINIMUM 3/8" SS/GALV BOLT LADDER BRACKET (GALV, SS, PP) PLAN 36" CMP ACCESS RISER NT- . BOLTS, ASHERS AIL R PIPE SS WASHER PLACE BOLT ON CROWN OF RISER CORRUGATION SS NUT PLATE WEL WITH ORIFICE AS SPECIFIED ELBOW-RESTRICTOR 1. PIPE SIZES AND SLOPES: PER PLANS. 2. EXCEPT AS SHOWN DR NOTED, UNITS SHALL BE CONSII ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BAS 54" MIN- DIAMETER- 3- PIPE SUPPORTS AND RESTRICTOR%SEPARATOR SHALL BE MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING 13Y DIAMETER STAINLESS STEEL EXPANSION BOLTS OR EMBE IN WALL. 4_ THE RESTRiCTOR/SEPARATOR SHALL BE FABRICATED FR( ALUMINUM OR .064" ALJMIN17ED STEEL. 5, OUTLET SHALL BE CONNECTED TO CULVERT OR STORM WITH STANDAD COUOPUNG BAND FOR CORRUGATED MET OR GROUTED INTO THE BELL OF CONCRETE PIPE. 6, FRAME AND LADDER OR STEPS OFFSET 5O THAT: A. C GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE 15 OF RISER AND CLEEWOUT GATE. C. FRAME IS CLE CURB. 7- IF METAL PIPE CONNECTS NTH CEMENT CONCRETE PIPE PIPE TO HAVE SMOOTH Q.D. EQUAL TO CONCRETE PIPE 1 /4". FLOW CONTROL STRUCTURE NTS 24' ROUND LOCKING FRAME AND COVER MARKED "DRAIN" MOUNTED OVER 24' DIA. ECCENTRIC OPENING CEIM. CONC. GRADE ----- RINGS AS REQ. COMPACTED MAINTAIN I" GAP BETWEEN BOTTOM OF BACKFILL SLAB AND TOP OF RISER. PROVIDE PLIABLE GASKET TO EXCLUDE DIRT 78" DETENTION PIPE ALUMINIZED CMP ♦ 36" RISER PIPE LADDER ANGLED ATTACHMENTS. MIN- 4 PER LADDER - MAX. VERTICAL SPACING, 36" x Q LADDER BASE PLATE, PLACE AS LOW 3 AS POSSIBLE AND TRIM AS NEEDED, C 1 fi SEE DETAIL SECTION NOTES; 1. RISER SHALL BE WELDED OR FUSED TO TANK. 2. ALL MATERIALS SHALL MEET CITY OF RENTON STANDARDS AND SPECIFICATIOINS. 3. MAINTAIN 1" GAP BETWEEN BOTTOM OF SLAB & TOP OF RISER, PROVIDE PLIABLE GASKET TO EXCLUDE DIRT 4. LADDER SHALL BE PLACED SO THAT TOP RUNG IS LESS THAN 8-INCHES FROM TOP OF RISER AND BOTTOM RUNG IS AS LOW AS POSSIBLE AND LESS THAN 12-INCHES TO BOTTOM INVERT OF PIPE 5. TOP OF LADDER SHALL BE AT LEAST 2-INCHES BELOW TOP OF RISER, 6. BOTTOM OF LADDER SHALL BE ATTACHED TO BASE PLATE WITH SS/GALV HARDWARE 7. WEIGHT OF LADDER TO REST ON BASE PLATE 5UR SCALE; 4ERi1S'.AL NAVE 19M8 7 SHARED DRIVEWAYS M❑ESlcnm. B 3 29 17 PA 1 "=10' HORIIONiAL: NAD rasa%1991 f CITY COMMENTS MB 09 16 PA MIS 5 CRY COMMENTS `MB 8 /1�5 1�6 PA ❑RAWN: MB 11 4 CITY COMMENTS MB 7 q7 16 PA CHECKED- 11� ONE IHCH d�TulVl PA RT Fl1LL SCW E IF NOT ONE INCH NO. RE,VIS*N F,3Y DAIE APP?R APPRoVE0 SCALE ACCORDINGLY Id 9,97 GRAVEL BATE ' I rno na�talc (WSDDT/API DETENTION TANK PER DETAIL 1/CIE GEOTEXTILE FABRIC- MIRAFI 140N OR APPRV'D EQUIV- 4" PERF- PVC SCH- 40 W f SOLVENT WELD JOINTS. EMBED IN CLEAN WASHED GRAVEL BACKFILL FOR DRAINS 6" ON EACH SIDE AND WRAP WITH MkRAFI 140N WITH T 2" OVERLAP. EXTERIOR FOOTING DRAIN C1fi NTS F— CONSTRUCTION PERM T BUBm TTAL 7ATE: CITY OF LII (ELITE SHORT PLAT FIELCB0Ok� K- R E N TO N 16204 114TH AVE SE, RENTON, WA 98055 PAGE MAWJNG NO: Planning/Building/public Works Dept- CML DETAILS C16 n RECORD DRAWING GRE FwAs�I� INFORMATION ADDEROBY TERRANE, INC. >1502� �w REPRESENTS THE RESU TS OF A SURVEY rGISTEg�� ��4 9L LAj;'Q CONDUCTED IN JULY, 20 8 490 crp ts, . J+ � c m M { a �(L 480 e J 'Ed Dole, 1 I1 10+00 NE 1 41 SEC 2 , T23N, R5E, W.M. RECORD DRAWING NAVD-88 EX T6P OF CURB ELEVATIN PROPOSED TOP OF CURB `3 ELEVATION 1;46 €� cn CIO [i 7 ty cc _ _BUD O'nrr, III LLJ BUILT 11+00 _ r9 + .r,¢`r L .Q w z co LJ w D<w cn U Li w LLJ a� -EX GRADE AT ROADWAY CENTERLINE 143 I:F A' ok,r CORE DRILL AND CONNECT TO EX SSMh I` f 469.53 RECHANNEL MH 12+00 500 m 470 C10-141 L m SE 162ND ST PROFILE DATUM NAV D +f i SCALE- HORZ. = 20' VERT. 1" = 1 G' 1 I � SERVED B # ,ERVEID 11 EX 8" SEWER �y 24 0 20 SERVED KInTF• nt D 4" AG ABANDONED IN PLACE SCALE: 1 = 20' (TYP) EX 6" WATER (TYP) REMOVE & RESTORE EXISTING g STA..1.0a:00 EX 8" SEWER ASPHALT PAVEMENT IN ACCORDANCE I1 C.ONC # r�UM!`NT Wf BRASS - DISC- , _ �70084 _ff:- • - — -- — L - - - - -- WITH CITY OF RENTON REQUIREMENTS - - -v-- --. — -- - a+a SE 162ND ST SAwcul �aN1 _ S88' 29' 38.90"E7E 1305087-02 1 +ao - = 1 +5i} r' '+ 12+ao � - 12+50 13+00 MH1299-11 "NUNN ' S EX 8" SEWER. _ _._.�._ _ --- - - EX 8" SEWER —mot ��--{ -� . _ I 62 `- - EX MH #62-ti Fes[ L& _ _ w RIM = 48.3-41 SERVED R;?= _ CTR CHAN = 469-43 CTR CHAR, = 466-02 STUB F 'LOT-j kDG.- CONNECTION EX 6" SS STUB , t r FIELD :LOCATE .. EX 6" SS STUB FOR r" f SERVED E 473 'BLDG, CONNECTION -77777777777777-7 - _ T.L. 2+88+37' X 7.5 r STUB FOR-1-tfl C3fE LOT 2 BLDG. CONNECTION jl 1 I .�I�I�I� PROPOSED IE 477.00 PROPOSED BLDG. NOTE:' A 4" AC � � EST. FF = 481-54f HOUSE F LOT 2 (TYP) � �4BANDOND PLACE I { } 11427 SE 162ND ST II i I r LDT 1 PARCEL # 0088000260 EST. FF = 482.50± II _-T, FF = 483.50t 1"� (Typ) Ti + STUB FOR LDT �k BL r - �. PROPERTY LINE. 3` 3 CUNNECTaOhi li [ 1£204 14TH AVE SE I IE 474.00 I. �I PARCEL # 0088000280 r - 5 LOT SHORTPLAT #' I SEE CITY OF RENTON LOT I FIELD LOCATE EX 6" 5S STUB' FOR ON -SITE DEVELOPMENT ��; - PLANS FOR DRAINAGE LOT 4 & 5 BLDG- CONNECTIO S j J i - EST. FF = 480-;,�.It -STUB FOR LOT 5'BLDG. (APPROX. 6 FT DEEP, IE 473Z), 91 j t -LOT S-BTOG.- - CONNECTION IMPROVEMENTS PROVIDE 6" WYE AND VERIFY IE _ - --- .- CONNECTION IE 476.00 PRIOR TO CONSTRUCTION -- _ _ .-- -_]E 474.00 FIELD VERIFY LOCATION AND 6" 5�51C i CONNECT TO EX N" SS CORE DRILL AND CONNECT TO EX SSMH, RECHANNEL IE 472.00 ,E, + EST. FF - 480.50+ r t' 21 EX MH #62--79 - ff RIM = 479.35 I: �. �. _.._..,. :..,..�..,..,. :..,. ,..,..,..�. 6" PVC IN NW & NE S" OUTS- CTR CHAN = 47t95 •...•��`",,�"�i�, _ - __, f =F 4�5 `=64 16220 114TH AVE SE /I DEX 8" SEWER SERVED PARCEL # 0088000281 C i i.' IE=475,58 ' K Rltj i SENDER GENERAL NOTES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE SPECIFICATIONS OF SOOS CREEK WATER AND SEWER DISTRICT, ALSO REFERRED TO HEREINAFTER AS "DISTRICT". 2- THE DEVELOPER SHALL FURNISH THE DISTRICT A COPY OF THE COMMERCIAL AND/OR SUBDIVISION PLANS APPROVED BY THE GOVERNING AGENCY PRIOR TO ANY SEWER MAIN CONSTRUCTION_ 3. PRIOR TO CONSTRUCTING ANY SEWER MAINS, THE APPROPRIATE STREETS AND LOTS SHALL BE CLEARED. GRADED, AND STAKED BY THE DEVELOPER/CONTRACTOR AND ALL EXISTING UTILITIES SHALL BE LOCATED. 4, FOLLOWING SEWER MAIN CONSTRUCTION, ANY REVISION OF ROADWAY OR EASEMENT GRADES REQUIRING THE MAINS TO BE RECONSTRUCTED SHALL BE MADE AT THE DEVELOPER'S/CONTRACTOR'S EXPENSE. 5, RECONSTRUCTION SHALL CONFORM TO THE SPECIFICATIONS OF THE DISTRICT. ALL COSTS FOR INSPECTING SUCH RECONSTRUCTION SHALL BE CHARGED TO THE DEVELOPER IN ADDITION TO THE STANDARD CHARGES, AND SHALL BE PAID BEFORE ACCEPTANCE BY THE DISTRICT. 6, NO SIDE SEWER CONNECTIONS SHALL BE MADE TO THE EXISTING SYSTEM UNTIL COMPLETION OF THE BILL OF SALE AND ALL EASEMENTS, OBTAIN SIDE SEWER PERMIT FROM THE DISTRICT FOR EACH SIDE SEWER CONNECTION PRIOR TO MAKING CONNECTION. BILL OF SALE WILL NOT BE PROCESSED UNTIL PUGET SOUND ENERGY HAS EITHER PROVIDED A WORK SKETCH OR INSTALLED THEIR VAULTS, HAND HOLES AND LIGHT STANDARDS, OR THE DEVELOPER HAS PROVIDED A SIGNED HOLD HARMLESS AGREEMENT (FORM SUPPLIED BY THE DISTRICT). 7. ALL COSTS OF SEWER MAIM RE -STAKING SHALL BE PAID BY THE DEVELOPER/CONTRACTOR. 8, PROPERTY CORNERS SHALL BE PINNED WITH REFERENCE TACK ON CURBS SY THE DEVELOPER /CONTRACTOR 9. THE DEVELOPER/CONTRACTOR SHALL NOTiFY THE DISTRICT AT (253) 630-9900 TO SCHEDULE A PRE -CONSTRUCTION MEETING AT THE DISTRICT OFFICE. AFTER THE PRE -CONSTRUCTION MEETING, THE DEVELOPER/ CONTRACTOR SHALL NOTIFY THE DISTRICT'S FIELD REPRESENTATIVE AT LEAST 48 HOURS (REGULAR WORKING HAYS) BEFORE STARTING WORK. 10. THE DEVELOPER/CONTRACTOR SHALL OBTAIN ALL REQUIRFD FINAL INSPECTIONS TO MEET PERMIT REQUIREMENTS. INSPECTIONS MUST BE SCHEDULED AT LEAST 48 HOURS IN ADVANCE. 11, CONNECTION TO EXISTING SEWER MAINS SHALL BE MADE ONLY WITH THE WRITTEN APPROVAL OF THE DISTRICT AND ONLY AFTER AT LEAST 48 HOURS (TWO REGULAR WORKING DAYS) ADVANCE NOTICE. 12, EXISTING SEWERS TO REMAIN IN SERVICE AT ALL TIMES- 13. ALL WATER AND OR CONSTRUCTION DEBRIS SHALL BE REMOVED FROM NEW SEWERS AND SHALL NOT BE PERMITTED TO ENTER THE EXISTING SYSTEM. 14, EXISTING MH #52-11 AND MH #62-79 SHALL BE CORE DRILLED AND RE-CHANNELIZED AS REQUIRED TO RECEIVE INCOMING FLOW FROM NEW SEWER. NOTES 1. ' FIELD VERIFY ELEVATIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2. THIS PLAN IS FOR SEWER D.E. (DEVELOPER EXTENSION). CONTACT SODS CREEK WATER AND SEWER DISTRICT FOR WATER SERVICE REQUIREMENTS AND PERMITS. 3. REFER TO SHEET 4 FOR APPLICABLE SODS CREEP( WATER AND SEWER DISTRICT SANITARY SEWER DETAILS. SHEET INDEX SH.NO. DESCRIPTION 1 SEINER PLAN AND PROFILE NOTES 2 CONSTRUCTION PROVISIONS 3 MATERIALS SURFACE RESTORATION j 4 SERVER DETAILS 7f, PROJECT i s E 13 SnVET SE 162ND STFEEr VICINITY MAP PLAN REVIEW 04-12 "16 fa' ' � 35183 l�C1STv��!v w k ?4 � ¢ w U Q6 Q Q� C) LZ �1 V —00 0 � O CS r� 00 O z a )Fx a..R C m u� ro L U cn ,� s` Lu v �.�, rri z Q om, Q a CL .0 �t � z, �4� ULU "a)z0 r+1 +) CL u CV �Ci II II L °z LIJ z O L� 0 z J OL Lu .j 0 cr)LL W w W T_ CL co ❑ C) W W w W a_ cn J w BASE MAP SHEET 1 OF 4 DRAinrNG B-280 RECORD DRAWING Z _0 P 20 STA 10+36.78, 12.21' RI CATCH BASIN RIM 460.61 RIM=480,24 IF 477.75 IE=477154 1 o00 N o 00 `� --LJ4zlCD r 1 w w ^� -1 � _° g� / �N1 0 = ! f � - i 1 I I C� 1 I II I w L �� I CU C yy Ln VSTA 20+39.88, I7k3' LT TYPE 2 W/ SDLID LID f I RIM 48a.og RIM=480110 � � NTH AVE �� IE 477.30 (NE), 472,81 (S)12"S IE=472,60 E-47519� +0 I Lim -- STLIRM ,'I- n l V O LJ I_ CC) I,-- II � r � LL Fi El I" WATER o CD } o I I o II' co w IE 472.81 "q- V)Z I I 1=1 �U T� _CL 06> w C� ��W Parcel NLimber:0088000280 Applicant Name: REVISI❑N 1" WATER Ex 6' SS, FIELD VERIFY ELEVATION PRIOR TO CONSTRUCTION 148 LF C-900 SD 0 1 0 153 LE @2101% In m Lo�,D In LO Ld II CU I- H IcI CU G a� of cc Q � J � R LO Lri g-, a", o 00 II II 2: w H H OR Lmm -11 NOW- I" WATER —IE 469.81 JE 471.33 1E 4fi9-45 PROJECT,:- BERNASCONI a ra Scale I" = 10' STA 21+93,00, 17.5' L — r 413" (-b 'lt� I Yf''E e W1 BEEHIVE ...UHA RIM 476.6o RIM=478 83 12" IE 469.63 (S, OUT)IE=1469,66 12" IE 469.63 (NW, IN)IE-469153 8" IE 473.60 (Sk IN)IE 475.53 12" IE 471.20 (N, IN) IE 469,53 1� I f- I � 1 STA 21+76.i2, €€.-84' LT INLET RIM 476,95 RIM=479109 I €E 475-90 �8' D1 S1:0IE=476189 +0 co 00�,DMMM CC) �,DLOLOU-) r-MMU�C� LLJ WL II II II II i1J H F I� w W I—i H N m � W 00 N [V n1 Site Address: 16204 1 14TH AVE SE, RENTON DNA 98055 IE 4fi9-63 �. �pWAS.�j��,�n, -t 1,555 LO2 5 ,AL LA�� � RECORD DR WING INFORMATIO ADDED BY TERRANE, INC. REPRESENTS TH RESULTS OF A SURVEY CONDUCTED IN JULY, 2018 Engineering Scale: 1" _ - Sheet of PREPARED B K IAA RBER T ENGINEERS 4620 ��200 TH S T SW SUITE B WAL YNN WOOD, 98036 PHONE- (206) 311— 3019 L ISA HA RBER TOOU TL 0OK. cOM Project File Number: