Loading...
HomeMy WebLinkAboutMFP19000210DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP19000210 IVR Number: 19000210 Permit Informaon Permit Name:Puget Sound Energy - Electric Address/Locaon :01/11/2019Application Date:7224000235Parcel Number:212 PARK AVE N Permit Type:01/22/2019Issue Date:Franchise Permit Work Class:01/22/2020Expiration Date:Minor Utility Job Number:101116670Franchise Type:Electric Description:Install overhead Bridal Service. Overhead work on Pole P01 and Pole P02. Install guy wire and Bridal Service. Contacts Name Address PhoneTypeBilling ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Applicant Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner ANISH KUMAR PUGET SOUND ENERGY - ELECTRIC 6905 S 228th St Kent, WA 98032 B: (253) 208-2183Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Puget Sound Energy - Electric 101116670 Anish Kumar 253-208-2183 anish.kumar@pse.com 212 Park Ave N 98057 101116670 Crew will be installing OH bridal service. Crew will do overhead work on P01 (318013-166178) and P02 (317994-166177) which is on private property to install guy wire and bridal service to '212'. City of Renton has approved overhead exemption for ***continued below Potelco Inc.253-208-2183 BL005109 Poteli*227PL 1/3/2019 MFP19000210 Holly Powers Scott Warlick 1/22/2019 1/22/2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: Reset FormPrint Form 101116670 PSE/Potelco Inc. Timothy LoPresto 425-393-4185 6905 S 228th St, Kent, WA 98032 timothy.lopresto@pse.com 212 Park Ave N TBD 1/21/2019 Anish Kumar 1/3/2019 MFP19000210 Scott Warlick 1/22/2019Monday - Friday 8:00AM - 3:30PM SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). the OH service modification to 212 Park Ave N. There will be one lane closed for installation of service. No pavement cuts anticipated. Restoration per City of Renton standards. 212 Park Ave N Renton WA 98057 USABUSSTOPMOVE BUS STOP TEMPORARILY 125' NORTH RIGHT LANE CLOSED AHEAD W20-5RW4-2LROAD WORK AHEAD W20-1200'200'200'ROADWORKAHEADW20-1ROADWORKAHEADW20-1100'ROADWORKAHEADW20-1 200'W20-7A N 2ND STPARK AVE NM6-2P01 P02 11 11 11 111515 1414CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 N PSE PUGET SOUND ENERGY JOB#101116670 212 PARK AVE N, RENTON, WA 12/21/2018 ryan.perkins@pse.com 425-424-6621 SHEET 1 of 1 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 008997 Card Exp. 08/13/2019 gregory.harwood@pse.com (425)424-6425 TEMPORARY TRAFFIC CONTROL PLAN Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m. 28" TRAFFIC CONE LEGEND TRAFFIC FLOW SIGN LOCATION FLAGGER STOP POLE WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY ROW ROW MFP19000210 224 1200 1206 223 221 217 220 216 214 212 210 204 200 215 211 1010 1/0 OH TPLX L=75' 318013-166178 25 kVA 120/240V (C) 2ND ST PARK AVE N317994-166177 65T X4009 WORKSITE GAS PHONE CABLE TV N/A 108110410 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior OH Removal Relocation Removal Temporary Job Order Distribution HP Svc/MSA Owner / Developer Contact Info officeATTN: FLORENCE WONG-HODGKIN 212 PARK AVE N RENTON, AW 98057 RYAN HUGHES 206-423-5064 Vicinity Map TG PG 656-D2 SITE SPECIFIC NOTES FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. SITE PLAN SCALE: 6" = 1 MILE OVERHEAD CIRCUIT MAP E-Mail: Cell Phone: Project Manager Contact Information: Manager:TIMOTHY LOPRESTO 425-393-4185 timothy.lopresto@pse.com PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" X X X X SCALE: 1" = 50' THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) Service Stubs 101116670 N/A N/A UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT Gas Order SCALE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO OH CKT MAP CIRCUIT NOUG CKT MAP T. LoPRESTO 425-748-6367 T. LoPRESTO 425-748-6367 N/A N/A QC. NGUYEN 425-748-6369 N/A RENTON RYAN HUGHS-WEST SEATTLE ELEC OH MODIFIED SVC 212 PARK AVE N, RENTON, WA N/A N/A AS NOTED KING N/A N/A QCNOKE NW17 T23N R05E N/A N/A 2305E066 2305E066NE 2305E088 GRA-17 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 506612108 N/A P01 GRID #318013-166178 -EXISTING POLE WILL REMAIN P02 GRID #317994-166177 - EXISTING POLE WILL REMAIN P01 TO P02 - EXISTING 4/0 NEUTRAL TO REMAIN P01 TO "212" - INSTALL OH BRIDAL SERVICE 1/0 [BSTPX] PER STD 6024.1000 35' FROM P01 - INSTALL 1/0 OH TPLX, L≈75'(___') CUSTOMER NOTES: **CUSTOMER PAYS ONLY FOR OH MODIFIED SERVICE** 6. TREAT ALL FIELD-DRILLED POLES WITH COPPER NAPHTHENATE WOOD PRESERVATIVE. 1. POLES, CONDUCTORS, DEVICES TO BE INSTALLED PER PSE STANDARDS & SPECIFICATIONS. 2. POLES ARE TO BE INSTALLED OR RELOCATED AS STAKED. 3. ALL NEW POLES SET SHALL BE THE CLASS INDICATED ON THE SKETCH OR BETTER. 4. INSTALL GROUND PLATE ASSEMBLY ON ALL NEW POLES. 5. INSTALL GRID NUMBERS ON ALL NEW AND EXISTING POLES AS SHOWN ON SKETCH. GENERAL OVERHEAD NOTES: NOTE: If the common neutral wire is 2/0 ACSR or larger, the mid span clamp may be attached to the common neutral and the span guy eliminated. Do not use the mid span clamp on any size of copper neutrals (see application statement). #2 ACSR may be substituted for 3/8 steel guy wire as an alternate method to support the bridle service wire. Ñ Automatic Guy Grip or Automatic Deadend #2 ACSR Preformed Guy Grip or 6 Alum “H” Conn#2 ACSR 13 10 Secure service wire to span guy with plastic zip ties as needed to prevent it from sagging into communications safety space. Mid-Span Tap Clamp 3 4 7 Service Wedge 1 2 8 Rigid Clevis 7 7 Service Wedge Common Neutral Typically up to 125 maximum for #2 or 1/0, 75 maximum for 4/0. 3/8 Span Guy #2 ACSR or Attach the service wedge deadend bail to the mid span tap clamp. 5 11 1 9 5/8 Eye Bolt with Curved Washer 12 4 To supporting structure or house Top View Service Wedge Bail Service Line Neutral Service Wedge Bail Mid span tap clamp fits steel guy and #4 4/0 ACSR common neutral conductor. Mid Span Clamp Detail Figure 1 Overhead bridle service, triplex or quadraplex wire OVERHEAD BRIDLE SERVICE @XFMR (P01) Load: 37.58 kW LRC: 65 A % V. Drop: 3.1% % Flicker: 1.5% LRC: Length: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: % V. Drop: Size: 800 SQ.FT. 200 AMPS GAS 8 KW 65 AMPS 75' 2.3% 3.5% 1/0 OH TPLX P01 - MTR "212" MFP19000210