HomeMy WebLinkAboutMFP17000545 - RevisionDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17000545
IVR Number: 17000545
Permit Informa!on
Permit Name:Qwest dba CenturyLink QC
Address/Loca!on:02/02/2017Applica!on Date:1823059046Parcel Number:620 S 7TH ST
Permit Type :02/02/2017Issue Date:Franchise
Permit Work Class:02/02/2018Expira!on Date :Minor U’lity
Est. Comple!on:03/07/2017Job Number:N.207384Franchise Type :Telephone
Descrip!on:Revised for new fiber placement path: Access MH 207, MH 293 and HH UN 166 to place and splice fiber. Access MHT
61E, HH UN 2, HH UN 1, HH 504, HH 514, HH 520, HH 528, HH 540 1 and bore ~364'. HH UN 165 will be accessed on
private property. Hard surface disturbance. NOTE: On site pre con required. Please call 72 hours prior to schedule.
Contacts
Name Address PhoneTypeBilling
Craig Schweikl
CenturyLink
B: (253) 854-4074Applicant
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
ContactX
Joe Riehl
Dycom Industries dba North Sky Communica’ons LLC
11770 Us Hwy 1, SUITE 101
Palm Beach Gardens, FL 33408
B: (425) 481-0979
H: (561) 627-7171
C: (425) 754-8134
Contractor
Business License Number: BL.036846Electrical Contractor : NORTHSC958NE
Construc!on Contractor : NORTHSC857Q4
Kari Roller
City of Renton
1055 S Grady Way
Renton, WA 98057-3232
B: (425) 430-6851
C: (425) 430-6931
Owner
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the condi’ons hereon and according to the approved
plans and specifica’ons pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all ’mes .
I hereby cer’fy that no work is to be done except as described above and in approved plans, and that work is to conform to Renton
Trench Restora’on and Street Overlay Requirements .
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspec’ons and for ANY work in
the Right of Way.
Call 8 1 1 to locate underground u’li’es at least two full business days prior to any excava’on .
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic
Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consulta’on with the transmission pipeline company prior
to performing any construc’on or excava’on ac’vi’es . This requirement to consult with the transmission pipeline company is in
addi’on to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 6TH ST
HH 540-1
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
N
BURNETT AVE S S 6TH STBURNETT AVE S
Comments:
ACCESS HH 540-1 LOCATED BEHIND SIDEWALK ON THE
EAST SIDE OF BURNETT AVE S, NORTH OF
S 6TH ST, FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
NOTIFY HOME OWNER PRIOR TO START
OF WORK REGARDING ACCESS TO DRIVEWAY.
SIDEWALK IS ACCESSIBLE.
SPOTTER WILL ASSIST PEDESTRIANS.
ONE WAY
R6-1
ONE WAY
R6-1
NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444
YOUR COMPANY NAME 555-5555
R7-T38
HH 540-1
WORK AREA
8 X 60ROADWORKAHEADW20-1SHOULDERWORKW21-5ROADWORKAHEADW20-1Legend
Work Area
Cone
Spotter
truck
www.invarion.com
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 6TH ST
SPLICE & FIBER PLCMT
HH 528
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
N
S 6TH STBURNETT AVE S
Comments:
ACCESS HH 528 LOCATED IN SIDEWALK ON THE
EAST SIDE OF BURNETT AVE S, NORTH OF
S 6TH ST, FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED AND NON-SKID STEEL PLATES
PLACED ON PLANTER STRIP TO MEET ADA
REQUIREMENTS.
SPOTTER WILL ASSIST PEDESTRIANS.
ONE WAY
R6-1
DETOURM4-9bDETOURM4-9bHH 528
WORK AREA
8 X 60ROADWORKAHEADW20-1SHOULDERWORKW21-5NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444
YOUR COMPANY NAME 555-5555
R7-T38ROADWORKAHEADW20-1Legend
Cone
Spotter
truck
Work Area
www.invarion.com
BURNETT AVE SONE WAYR6-1ONE WAYR6-1BURNETT AVE SS 5TH ST
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 5TH ST
SPLICE & FIBER PLCMT
HH UN-1
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
Comments:
ACCESS HH UN-1 LOCATED IN SIDEWALK ON THE
NE CORNER OF BURNETT AVE S & S 5TH ST,
FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED TO MEET ADA
REQUIREMENTS.
SPOTTER WILL ASSIST PEDESTRIANS.
HH 520
WORK AREA
8 X 60NOPARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444
YOUR COMPANY NAME 555-5555
R7-T38
N
DETOUR
M4-9bDETOURM4-9bWILLIAMS AVE SONE WAYR6-1ROAD
WORK
AHEAD
W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDER
WORK
W21-5ROADWORKAHEADW20-1Legend
Cone
Spotter
truck
Work Area
www.invarion.com
S 5TH ST
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 LComments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
S 5TH ST @ WILLIAMS AVE S
SPLICE & FIBER PLCMT
MH T-61E
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
Comments:
ACCESS MH T-61E LOCATED IN IN THE NW
QUADRANT OF INTERSECTION AT
S 5TH ST & WILLIAMS AVE S,
FOR SPLICING & PLACING FIBER.
THIS IS A LANE SHIFT AROUND WORK AREA.
PARKING RESTRICTED IN WORK AREA.
CROSSWALK IS ACCESSIBLE.
SPOTTER WILL ASSIST PEDESTRIANS.
N
WILLIAMS AVE SONE WAYR6-1ROAD
WORK
AHEAD
W20-1
LANE
SHIFT
AHEAD
W5-5
W1-4
ROADWORKAHEADW20-1NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
R7-T38 NOPARKING7AM - 6PMFROM TOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555R7-T38MH T-61E
WORK AREA
8 X 80 SHOULDERWORKW21-5ONE WAYR6-1WELLS AVE SLegend
Cone
truck
flagger symbol
Work Area
www.invarion.com
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 6TH ST
SPLICE & FIBER PLCMT
HH 520
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
N
S 6TH STBURNETT AVE S
Comments:
ACCESS HH 520 LOCATED IN SIDEWALK ON THE
EAST SIDE OF BURNETT AVE S, NORTH OF
S 6TH ST, FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED AND NON-SKID STEEL PLATES
PLACED ON PLANTER STRIP TO MEET ADA
REQUIREMENTS.
SPOTTER WILL ASSIST PEDESTRIANS.
ONE WAY
R6-1
DETOURM4-9bDETOURM4-9bHH 520
WORK AREA
8 X 60ROADWORKAHEADW20-1SHOULDERWORKW21-5NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444
YOUR COMPANY NAME 555-5555
R7-T38ROADWORKAHEADW20-1Legend
Cone
Spotter
truck
Work Area
www.invarion.com
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 5TH ST
SPLICE & FIBER PLCMT
HH 514
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
N
S 6TH STBURNETT AVE S
Comments:
ACCESS HH 514 LOCATED IN SIDEWALK ON THE
EAST SIDE OF BURNETT AVE S, SOUTH OF S 5TH ST,
FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED AND NON-SKID STEEL PLATES
PLACED ON PLANTER STRIP TO MEET ADA
REQUIREMENTS.
SPOTTER WILL ASSIST PEDESTRIANS.
ONE WAY
R6-1
DETOURM4-9bDETOURM4-9bHH 514
WORK AREA
8 X 60ROADWORKAHEADW20-1SHOULDERWORKW21-5NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
R7-T38ROADWORKAHEADW20-1Legend
Cone
Spotter
truck
Work Area
www.invarion.com
BURNETT AVE S ONE WAY
R6-1
ONE WAY
R6-1
BURNETT AVE S
S 5TH STProject # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 5TH ST
SPLICE & FIBER PLCMT
HH 504
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
NComments:
ACCESS HH 504 LOCATED IN SIDEWALK ON THE
EAST SIDE OF BURNETT AVE S, NORTH OF
S 6TH ST, FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED TO MEET ADA
REQUIREMENTS.
SPOTTER WILL ASSIST PEDESTRIANS.DETOURM4-9bDETOURM4-9bHH 504
WORK AREA
8 X 60
NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444
YOUR COMPANY NAME 555-5555
R7-T38ROADWORKAHEADW20-1SHOULDERWORKW21-5Legend
Cone
Spotter
truck
Work Area
www.invarion.com
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
BURNETT AVE S @ S 6TH ST
BORE PIT 2
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
N
BURNETT AVE S S 6TH STBURNETT AVE S
Comments:
SET UP BORE PIT 2 IN SIDEWALK ON THE
EAST SIDE OF BURNETT AVE S, NORTH OF
S 6TH ST.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED TO MEET ADA REQUIREMENTS.
NOTIFY HOME OWNER PRIOR TO START
OF WORK REGARDING ACCESS TO DRIVEWAY.
SPOTTER WILL ASSIST PEDESTRIANS.
ONE WAY
R6-1
ONE WAY
R6-1
ROADWORKAHEADW20-1SHOULDERWORKW21-5ROADWORKAHEADW20-1HH 540-1
WORK AREA
8 X 60
BP 2 DETOURM4-9bDETOURM4-9bNO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
R7-T38
Legend
Cone
flagger symbol
truck
Work Area
www.invarion.com
BURNETT AVE SONE WAYR6-1ONE WAYR6-1NO PARKING
7AM - 6PM
FROM TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
R7-T38
BURNETT AVE SS 5TH ST
Project # N.207384 C.02
Designed for CenturyLink by
Sharon Martos
Traffic Control Supervisor
TCS # 007602
Approved 05/04/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
TRAFFIC CONTROL PLAN
JOB # N.207384 C.02
PERMIT #
Date:05/04/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.207384 C.02
CERT:TCS # 007602 Designed for CenturyLink:By Sharon Martos
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
S 5TH ST @ WILLIAMS AVE S
SPLICE & FIBER PLCMT
HH UN-2
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 007602 sharon.martos@gmail.com
Comments:
ACCESS HH UN-2 LOCATED IN SIDEWALK ON THE
NORTH SIDE OF S 5TH ST, WEST OF
WILLIAMS AVE S,FOR SPLICING & PLACING FIBER.
THIS IS SHOULDER WORK.
PARKING RESTRICTED IN WORK AREA.
SIDEWALK CLOSED IN WORK AREA.
PEDESTRIANS ROUTED AROUND WORK AREA.
CURB TO BE RAMPED TO MEET ADA
REQUIREMENTS.
SPOTTER WILL ASSIST PEDESTRIANS.
N
WILLIAMS AVE SONE WAYR6-1ROAD
WORK
AHEAD
W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5DETOURM4-9bDETOURM4-9bHH UN-2
WORK AREA
8 X 60 ROADWORKAHEADW20-1Legend
Cone
Spotter
truck
Work Area
www.invarion.com