HomeMy WebLinkAboutP_CAD_N.207384_v1CONSTRUCTION NOTES, 1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING. 2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO EXCAVATION. 3. FOR UNDERGROUND ACTIVITY, TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS. 4. ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926.650 SUBPART P. a. PROVIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS. b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24' EDGE OF PIT OR TRENCH. c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY, ALL BARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY. d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY. 5. TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS, THE TRENCH IS TO BE A MINIMUM OF 36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE STANDARDS WILL BE SPECIFIED ON THE PLANS.) 6. ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. 7. NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING. 8. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED. 9, BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S). 10, AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING WORK PER STATE AND LOCAL REGULATIONS. 11, ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO BE WITH APPROVED WARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTED TO THE REQUESTING PERMITTING AGENCY, PRIOR TO BEGINNING WORK, PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION ACTIVITIES. 12. EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS. 13. THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIOR TO CONSTRUCTION. THIS JOB WILL PLACE NEW EQUIPMENT AT 620 S 7TH ST, RENTON. NOTE, THIS JOB IS AN IPC, PLEASE CONTACT FIELD ENGINEER WITH ANY QUESTIONS OR CONCERNS - CORY COATE 503-961-5023 FIBER: CTL WILL PLACE APPROX. 1363 TOTAL FIBER AND INNERDUCT. CTL WILL ACCESS VAULTS MH3-207.1, MH3C-293, HH UN -166, AND CUST SERVING HH UN -165 TO PLACE AND SPLICE FIBER. CTL WILL PLACE 1X16 SPLITTER IN MH293. CTL WILL ATTEMPT TO PLACE APPROX. 350 FEET OF FIBER AND INNERDUCT FROM CUSTOMER SERVING HH UN -165 TO THE CUST MPOP IN A 2INCH CONDUIT ALONGSIDE WHAT LOOKS TO BE LIKE A 100 PAIR CABLE. IF CTL IS NOT SUCCESSFUL CUSTOMER WILL WANT TO WORK WITH CTL ENGINEER TO LOOK AT OPTIONS TO CREATE A NEW PATH INTO THEIR BLDG. ALSO NOTE CTL WILL ATTEMPT TO PLACE CAT5E CABLE FROM IST FLOOR TELCO ROOM TO THE CUSTOMERS 2ND FLOOR SERVER ROOM APPROX. 125 FEET. NOTE, THIS PATH HAS TWO HOLES 1 -HOLE IN THE WALL AND THE OTHER IN THE CEILING AS A RISER TO THE 2ND FLOOR, THESE HOLES ARE PACK WITH EXISTING CATS CABLE. CenturyLinkr- All Underground Utility Locations Shown Hereon Are Approximate.Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities NEW IPC JOB USE FW# N.207384 POF MH 207 LRE 14,15 / PLACE NEW 24CT FROM MH 207, TO MH 293, PLACE 1X16 SPLITTER IN MH 293, PLACE NEW 24CT FROM MH 293 THRU HH UN -166, THRU HH UN -165 TO CUST MPOP CUSTOMER: WILL WANT TO PROVIDE A NEW 4'X4' 3/41NCH BACK BOARD ON THE NORTH WALL OF 1ST FLOOR TELCO ROOM. CALL TWO WORKING DAYS BEFORE YOU DIG Q 811 PLOTTED: 03/23/2017 BY: PHILLIP PRICE NOTICE - NOT FOR DISCLOSURE OF 620 S. 7TH STREET RENTON, WA 98057 DRAFTED BY: KILLION COMM. FIELD ENGINEER: CORY COATE (503)-961-5023 23N I 5E 1 18 AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT GEO CODE: WC CLLI: RNTNWA01 SH 1 OF 3 PERMITS YES/NO VICINITY MAP DESIGNED SERVICES: ❑ HELD ORDERS: ❑ ROW REQUIRED: ❑ ® ❑ CITY: ;. 8 © COUNTY: ❑ ❑ I� STATE: Dojo3Q Renton City j 8 Municipal COurt® RAILROAD: ❑ I LOOP QUAL.: ❑ 11127111 WORK LOCATION 620 S 7TH ST. 620 South 7th Str«t PREMIS FORM: ❑ I CONFORMANCE TEST: ® ❑ CarWashSEEJDS (Briownar vron ERFS DATE: lOSam's Club TRENCH OPEN DATE: ARCMH-207 APPROVED MNEMONICS: f of ASSOCIATED PROJECTS: !y �1 Triton Tower One NOTE, THIS JOB IS AN IPC, PLEASE CONTACT FIELD ENGINEER WITH ANY QUESTIONS OR CONCERNS - CORY COATE 503-961-5023 FIBER: CTL WILL PLACE APPROX. 1363 TOTAL FIBER AND INNERDUCT. CTL WILL ACCESS VAULTS MH3-207.1, MH3C-293, HH UN -166, AND CUST SERVING HH UN -165 TO PLACE AND SPLICE FIBER. CTL WILL PLACE 1X16 SPLITTER IN MH293. CTL WILL ATTEMPT TO PLACE APPROX. 350 FEET OF FIBER AND INNERDUCT FROM CUSTOMER SERVING HH UN -165 TO THE CUST MPOP IN A 2INCH CONDUIT ALONGSIDE WHAT LOOKS TO BE LIKE A 100 PAIR CABLE. IF CTL IS NOT SUCCESSFUL CUSTOMER WILL WANT TO WORK WITH CTL ENGINEER TO LOOK AT OPTIONS TO CREATE A NEW PATH INTO THEIR BLDG. ALSO NOTE CTL WILL ATTEMPT TO PLACE CAT5E CABLE FROM IST FLOOR TELCO ROOM TO THE CUSTOMERS 2ND FLOOR SERVER ROOM APPROX. 125 FEET. NOTE, THIS PATH HAS TWO HOLES 1 -HOLE IN THE WALL AND THE OTHER IN THE CEILING AS A RISER TO THE 2ND FLOOR, THESE HOLES ARE PACK WITH EXISTING CATS CABLE. CenturyLinkr- All Underground Utility Locations Shown Hereon Are Approximate.Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities NEW IPC JOB USE FW# N.207384 POF MH 207 LRE 14,15 / PLACE NEW 24CT FROM MH 207, TO MH 293, PLACE 1X16 SPLITTER IN MH 293, PLACE NEW 24CT FROM MH 293 THRU HH UN -166, THRU HH UN -165 TO CUST MPOP CUSTOMER: WILL WANT TO PROVIDE A NEW 4'X4' 3/41NCH BACK BOARD ON THE NORTH WALL OF 1ST FLOOR TELCO ROOM. CALL TWO WORKING DAYS BEFORE YOU DIG Q 811 PLOTTED: 03/23/2017 BY: PHILLIP PRICE NOTICE - NOT FOR DISCLOSURE OF 620 S. 7TH STREET RENTON, WA 98057 DRAFTED BY: KILLION COMM. FIELD ENGINEER: CORY COATE (503)-961-5023 23N I 5E 1 18 AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT GEO CODE: WC CLLI: RNTNWA01 SH 1 OF 3 AERIAL LEGEND EXISTING EQUIPMENT LEGEND AMC ANCHOR --- -=------- --- _ ----- --- EDGE OF PAVEMENT ;o, TELEPHONE BULLET PEDESTAL O ELECTRIC PEDESTAL/CABINET A GAS METER CA ARM CABLE ARM — C/L — CENTERLINE ® TELEPHONE REPEATER ava ELECTRIC TRANSFORMER 2 GAS VALVE CATV CABLE TV - R/W- - R/W- RIGHT OF WAY ® TELEPHONE PEDESTAL CID ELECTRIC METER G1 WATER METER P/L PROPERTY LINE TO TELEPHONE VAULT/HANDHOLE � ELECTRIC VAULT/HANDHOLE ® WATER VALVE DG DOWN GUY — — — — — — — — — — EASEMENT TELEPHONE CABINET QT ELECTRIC MANHOLE -5 FIRE HYDRANT DGA DOUBLE GUARD ARM - __-_.- ,---_ -•------_---_---- CURB & GUTTER ®T TELEPHONE MANHOLE e ELECTRIC J-BOX ® WATER MANHOLE ----- ,--- "- -- - RAILROAD ® TELEPHONE COOL PED Q SEWER MANHOLE [A IRRIGATION METER FGA FIBER GLASS ARM ------ -< -- - - -- - - FENCE EI TELEPHONE SAI ® STORM DRAIN CATCH BASIN ® IRRIGATION VALVE F/S FIELD SIDE — - - -TEL- - - -TEL- - - -TEL— TELCO MR TELEPHONE USAM ® STORM DRAIN INLET CULVERT GA GUARD ARM ELEC ELECTRIC O TELEPHONE OWNED POLE ® SEWER DRAIN MANHOLE -- TRAFFIC SIGNAL VAULT/HANDHOLE CATV CATV ® JOINT USE POLE C/L MONUMENT �_�; TRAFFIC SIGNAL POLE HOA HEIGHT OF ATTACHMENT -------- - - GAS Q CATV BULLET PEDESTAL ® POLE ITEM NO. STREETLIGHT M/R MAKE READY TRAFFIC SIGNAL Evj CATV PED OHG OVERHEAD GUY WATER WATER — WATER F-TV-1 CATV VAULT/HANDHOLE — SEWER SEWER — SEWER R/S ROAD SIDE STORM STORM STORM SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER IRRIG IRRIG IRRIGATION SWA SIDEWALK ANCHOR AND GUY T TELEPHONE TERM TERMINAL TRANS TRANSFORMER PROPOSED EQUIPMENT LEGEND TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP SECONDARY POWER CABLES AND/OR TOP OF RISER CABLES SO PROPOSED CABLE CAN BE ATTACHED - - - - - - - - - - - - - - - - PARKWAY TRENCH ® 2'x2' RECEIVING PIT >- ANCHOR & DOWN GUY WITHOUT VIOLATING THE 40' RULE. ® 4'x4' RECEIVING PIT DOWN GUY BORE CABLE ARM ATTACHMENT LOCATIONS X7, SAI xxx• ASPHALT TRENCH FOOTAGE TF TOP FIELD SIDE ASPHALT TRENCH ® COOL PEDESTAL xxx' I DIRT OR S/W TRENCH FOOTAGE TS TOP STREET SIDE BORE FOOTAGE F-E-1 ELECTRIC PEDESTAL x x-)-rj TIP TOP INSIDE POSITION AERIAL BUILD OT TELCO HANDHOLE xxx• AERIAL FOOTAGE TIS TOP INSIDE STREET SIDE AERIAL ® TELCO PEDESTAL TMP TOP MIDDLE POSITION SLACK PAND OT TELCO CABINET TOP TOP OUTSIDE POSITION Al A ERIAL STRAND TELCO MANHOLE TOS TOP OUTSIDE STREET SIDE BF BOTTOM FIELD SIDE BS BOTTOM STREET SIDE BIP BOTTOM INSIDE POSITION BIS BOTTOM INSIDE STREET SIDE BMP BOTTOM MIDDLE POSITION BOP BOTTOM OUTSIDE POSITION Bos BOTTOM OUTSIDE STREET SIDE FIELD ENGINEER: CORY COATE (503}961-5023 TOWN: RANGE: SECT: 23N 5E 18 All Underground Utility Locations Shown Hereon Are NOTICE - NOT FOR DISCLOSURE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT JOB: N.207384 �� Approximate.Construction Contractor Is Responsible CALL TWO WORKING DAYS For The Location Of Municipal And Private Utilities BEFORE YOU DIG 44 e n t U ry L 1 n R n 620 S. 7TH STREET RENTON, WA 98057 CODE: GEO CODE: 811 WC RNTNWA01 WC PLOTTED: 03/23/2017 BY: PHILLIP PRICE SH 2 OF 3 DRAFTED BY: KILLION COMM. I ----/L3 -- c/L --- — MH3T61E r STA.0+00 r STA. +07 - -.--- STA. +11 V o I 0 161' CTL DUCT N M N 7STA1+30 I J u STA. [1 +46 10' HH UN -2 o -T7 STA. 1+59 0 0 N N N M M th n n � 128' CTL �~ 5' DUCT - STA. 2+73 T. STA. 2+77 10' 112' CTL DUCT C/L -- C/L --- — 115' CTL DUCT STA. 2+98 o rn 0 0 0 Q I� r� v1 CenturyLink­ C/L 3 HH514 60' C/ /W_ #1rj6Z14AfS A PE S -HH528 LID NOT ABLE TO OPEN ALL WAY C/L -TRENCH 2'1-2" DUCT TO BORE PIT -CTL TO REMO 16'X10' SIDEWALK PANEL AT DRIVE WAY OF 538 ALSO REPLACE C/L --- C/L W -NOTE THIS PROPOSED BORE WILL HAVE TO BE LOOKED AT BY ROW DEPARTMENT LOOKS LIKE HH UN -165 IS ON CITY OF RENTON PROPERTY KING COUNTY GIS O p N O N N N !n \ FQ- tn -PL 1233' OF I.D. AND FIBER TOTAL BORE 1-2" DUCT 346' p to N N h N O N O N O O N r r r N N N n r N a HH540-1 , BORE PIT 8' 9' r HH UN -165 1 r 111 O _-- -I HH520 I HH528 8 ADA RAMP 108' CTL DUCT 153' CTL DUC 110' CTL DUCT + rn — C/L C/L + N BURYVETT APES `� �' CO All Underground Utility Locations Shown Hereon Are Approximate.Constructlon Contractor Is Responsible For The Location Of Municipal And Private Utilities CALL TWO WORKING DAYS BEFORE YOU DIG Q 811 NOTICE - NOT FOR DISCLOSURE OF 620 S. 7TH STREET RENTON, WA 98057 FIELD ENGINEER: CORY COATE (503)-961-5023 23N I 5E 1 18 AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT GEO CODE: WC CLLI: RNTNWA01 11 1 PLOTTED: 03/23/2017 BY: PHILLIP PRICE I DRAFTED BY: KILLION COMM. I - SH 3 OF 3 11 N N N !n \ FQ- tn -PL 1233' OF I.D. AND FIBER TOTAL All Underground Utility Locations Shown Hereon Are Approximate.Constructlon Contractor Is Responsible For The Location Of Municipal And Private Utilities CALL TWO WORKING DAYS BEFORE YOU DIG Q 811 NOTICE - NOT FOR DISCLOSURE OF 620 S. 7TH STREET RENTON, WA 98057 FIELD ENGINEER: CORY COATE (503)-961-5023 23N I 5E 1 18 AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT GEO CODE: WC CLLI: RNTNWA01 11 1 PLOTTED: 03/23/2017 BY: PHILLIP PRICE I DRAFTED BY: KILLION COMM. I - SH 3 OF 3 11