Loading...
HomeMy WebLinkAboutMFP17002616DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17002616 IVR Number: 17002616 Permit Informa!on Permit Name:Century Link Permits Address/Loca!on:06/05/2017Applica!on Date:1457500119Parcel Number:14302 160TH AVE SE Permit Type :06/29/2017Issue Date:Franchise Permit Work Class:06/29/2018Expira!on Date :Minor U’lity Job Number:N.218129Franchise Type :Telephone Descrip!on:Trench 80' across 160th Ave SE. Restora’on per City of Renton Standards. Contacts Name Address PhoneTypeBilling QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Applicant QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 ContactX Kim Parker QWest Corpora’on 931 14th St, SUITE 1000A Denver, CO 80202 B: (303) 992-0752ContractorX Business License Number: BL.000953Construc!on Contractor : QWESTC*000QG CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010 ) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date MFP17002616 Restoration per City of Renton Standards Justin Johnson 6-29-2017 6-29-2017Holly Powers MFP17002616 Justin Johnson 6-29-2017 8:00 AM TO 3:00 PM MONDAY THROUGH FRIDAY TRAFFIC CONTROL PLAN JOB # N. 218129. C. 14 PERMIT # Comments: MERGING TAPER LENGTH TAPER ("L") LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Comments: TRENCH 80' ACROSS 160TH AVE SE & RESTORE. ONE-LANE TWO-WAY TRAFFIC OPERATION. FLAGGERS WILL ASSIST WITH DRIVEWAYS. FLAGGERS WILL ASSIST WITH PEDESTRIANS. FLIP SETUP HALFWAY ACROSS ROADWAY.NDate:5/18/2017 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 218129. C. 14 CERT:TCS # 008931 CENTURYLINK:Certified Traffic Control Plan [DO NOT ALTER]LOC::4097 Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY tAPER 50' TO 100'max Designed For: CENTURYLINK Project # N. 218129. C. 14 Jeffrey D. Hubbard Traffic Control Supervisor TCS # 008931 Approved 5/18/2017 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ 160TH AVE SE @ SE 144TH ST TRENCH / RESTORE UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTER THIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM: JEFFREY D. HUBBARD, TCS# 008931, JHUBBARD.TCP@GMAIL.COM SPEED LIMIT 25 14302 160TH AVE SE BE PREPAREDTO STOPROADWORKAHEADW20-1W20-7BW20-7ABE PREPAREDTO STOPROADWORKAHEADW20-1W20-7BW20-7ASE 144TH STSE 144TH STP.317580 160TH AVE SE 160TH AVE SE SHOULDER SHOULDER TRENCH RESTORE WORK AREA 16' X 150'11' 11'11' 11' SHEET 1 OF 2 Legend CONES FLAGGER WORK AREA WORK TRUCK www.invarion.com TRAFFIC CONTROL PLAN JOB # N. 218129. C. 14 PERMIT # Comments: MERGING TAPER LENGTH TAPER ("L") LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Comments: TRENCH 80' ACROSS 160TH AVE SE & RESTORE. ONE-LANE TWO-WAY TRAFFIC OPERATION. FLAGGERS WILL ASSIST WITH DRIVEWAYS. FLAGGERS WILL ASSIST WITH PEDESTRIANS. FLIP SETUP HALFWAY ACROSS ROADWAY.NDate:5/18/2017 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 218129. C. 14 CERT:TCS # 008931 CENTURYLINK:Certified Traffic Control Plan [DO NOT ALTER]LOC::4097 Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY tAPER 50' TO 100'max Designed For: CENTURYLINK Project # N. 218129. C. 14 Jeffrey D. Hubbard Traffic Control Supervisor TCS # 008931 Approved 5/18/2017 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ 160TH AVE SE @ SE 144TH ST TRENCH / RESTORE UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTER THIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM: JEFFREY D. HUBBARD, TCS# 008931, JHUBBARD.TCP@GMAIL.COM SPEED LIMIT 25 14302 160TH AVE SE BE PREPAREDTO STOPROADWORKAHEADW20-1W20-7BW20-7ABE PREPAREDTO STOPROADWORKAHEADW20-1W20-7BW20-7ASE 144TH STSE 144TH STP.317580 160TH AVE SE 160TH AVE SE SHOULDER SHOULDER TRENCH RESTORE WORK AREA 16' X 150'11' 11'11' 11' SHEET 2 OF 2 Legend CONES FLAGGER WORK AREA WORK TRUCK www.invarion.com