HomeMy WebLinkAboutP_CAD_N.236745_170605_v1CONSTRUCTION NOTES,
1. CALL UTILITY LOCATE AT 811 72 HOURS PRI❑R TO
N
PERMITS
TRENCHING OR DIGGING,
2.
THE EXISTENCE AND L❑CATION OF ANY UNDERGROUND
YES/NO
UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS
WERE OBTAINED BY FIELD INSPECTI❑N AND A SEARCH OF VICINITY MAP
DESIGNED SERVICES:
❑
THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE
ACTUAL LOCATION AND NATURE OF THE UNDERGROUND
FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT
HELD ORDERS:
❑
SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO
EXCAVATI❑N.
3.
FOR UNDERGROUND ACTIVITYt TEST AND VENTILATE
ROW REQUIRED:
❑
MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING
DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND
USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL,
®
❑
STATE, AND LOCAL REGULATIONS.
CITY:
4,
ALL EXCAVATI❑N, TRENCHING, AND SH❑RING IS T❑ ADHERE
TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926 650
❑
SUBPART P.
COUNTY'
a.
PROVIDE ALL PITS WITH 1'xi' SLOPE AT ONE END OF MH113
EXCAVATION F❑R TECHNICIAN INGRESS/EGRESS.
11b.
EXCAVATED SP❑ILS ARE TO BE NO LESS THAN 24' EDGE OF SW 7th 5t
S�r�l 7l
STATE:
PIT OR TRENCH,
c.
BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC
SAFETY. ALL BARRICADES MUST BE EQUIPPED WITH FLASHING
RAILROAD:
❑
LIGHTS FOR NIGHT VISIBILITY,
d.
FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE
5,
SHORING FOR WALL STABILITY. WORK LOCATION
TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS,
LOOP QUAL.:
❑
333 SW 7TH ST
DEBRIS, AND CLODS. THE TRENCH IS TO BE A MINIMUM OF
36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF
COVER IN UNDEVELOPED AREAS (ANY VARIANCE FR❑M THESE
PREMIS FORM:
❑
STANDARDS WILL BE SPECIFIED ON THE PLANS.)
6.
ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED,
5Columbia
DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION
CONFORMANCE TEST:
®
❑
SHALL BE RESTORED TO ORIGINAL C❑NDITI❑N OR BETTER.
7.
NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING,
SEE JDS
8.
ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.
9.
BOND BURIED/AERIAL FACILITIES AS REQUIRED BY
JURISDICTI❑NAL AGENCY(S).
10.
AERIAL FACILITIES ARE TO BE TESTED PRI❑R TO BEGINNING
ERFS DATE:
WORK PER STATE AND LOCAL REGULATIONS.
11.
ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO
BE WITH APPROVED WARNING DEVICES AND PLACED PER
TRENCH OPEN DATE:
STATE DEPARTMENT OF TRANSPORTATION AND/DR PUBLIC
WORKS ENGINEERING DEPARTMENT STANDARDS AND
SPECIFICATI❑NS, IF REQUIRED, A TRAFFIC CONTROL PLAN
APPROVED MNEMONICS:
SHALL BE SUBMITTED TO THE REQUESTING PERMITTING
AGENCY, PRIOR TO BEGINNING WORK, PERMITTING AGENCIES
MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTI❑N
ACTIVITIES.
12,
EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS
ASSOCIATED PROJECTS:
SHALL BE MAINTAINED AT ALL TIMES, AS NECESSARY,
TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS
SHALL BE PROVIDED AND MAINTAINED PER STATE
DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS
ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS.
13,
THE FOLL❑WING FOOTAGES ARE ESTIMATES. F❑❑TALES TO BE
VERIFIED PRIOR TO CONSTRUCTION.
SCOPE OF WORK:THISJOB WILL PLACE NEW EQUIPMENT AT 333 SW 7TH ST, RENTON
FIBER:
CTL CREWS WILL PLACE APPROX. 274 FEET OF 1-1/41NCH INNERDUCT AND 24CT FIBER FROM MH113 THRU CTL PED AND INTO CUSTOMERS
BLDG'S MPOP.
FIBER COUNT: LRE28, 3-4
PLANNER NOTES ADDED FOR REFERENCE BELOW:
POINT OF FEED:
POF MH 113 LRE28, 3-4 / PLACE NEW 24CT FROM MH113 TO OUST MPOP
CenturyLink--
All
Underground Utility Locations Shown Hereon Are
Approximate. Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
CUSTOMER: FIELD VERIFIED 2-41NCH CONDUIT IN THE MPOP WITH 1 BEING VACANT AND HAVING A PULL
STRING IN IT. CTL CREWS WILL PLACE 1-1/41NCH INNERDUCT FROM CTL SERVING PED TO BLDG'S MPOP.
CALL TWO WORKING DAYS
BEFORE YOU DIG
81 1
PLOTTED: 04111/2017 BY: SARAH THATCHER
FIELD ENGINEER: CORY COATE
(503)-961-5023
TOWN: RANGE: SECT:
23N I SE 1 19
NOTICE - NOT FOR DISCLOSURE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
JOB: N.237645
333 SW. 7TH STREET
RENTON, WA 98057 1 GEO CODE:
DRAFTED BY: KILLION COMM.
WC CLLI: RNTNWA01
SH 1 OF 3
AERIAL LEGEND
ANC ANCHOR
CA ARM CABLE ARM
CATV CABLE TV
DG DOWN GUY
DGA DOUBLE GUARD ARM
FGA FIBER GLASS ARM
F/S FIELD SIDE
GA GUARD ARM
HOA HEIGHT OF ATTACHMENT
M/R MAKE READY
OHG OVERHEAD GUY
R/S ROAD SIDE
SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER
SWA SIDEWALK ANCHOR AND GUY
T TELEPHONE
TERM TERMINAL
TRANS TRANSFORMER
TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP
SECONDARY POWER CABLES AND/OR TOP OF RISER
CABLES S❑ PROPOSED CABLE CAN BE ATTACHED
WITHOUT VIOLATING THE 40' RULE.
CABLE ARM ATTACHMENT LOCATION,
TF TOP FIELD SIDE
TS TOP STREET SIDE
TIP TOP INSIDE POSITION
TIS TOP INSIDE STREET SIDE
TMP TOP MIDDLE POSITION
TOP TOP OUTSIDE POSITION
TOS TOP OUTSIDE STREET SIDE
BF BOTTOM FIELD SIDE
BS BOTTOM STREET SIDE
BIP BOTTOM INSIDE POSITION
BIS BOTTOM INSIDE STREET SIDE
BMP BOTTOM MIDDLE POSITION
BOP BOTTOM OUTSIDE POSITION
BOS BOTTOM OUTSIDE STREET SIDE
CenturyLink-
I
EXISTING EQUIPMENT LEGEND
EDGE OF PAVEMENT ® TELEPHONE BULLET PEDESTAL I-7_1 ELECTRIC PEDESTAL/CABINET
C/L
CENTERLINE
®
TELEPHONE
REPEATER
PWR
ELECTRIC TRANSFORMER
-R/W- -R/W-
RIGHT OF WAY
®
TELEPHONE
PEDESTAL
CD
ELECTRIC METER
P/L ---
PROPERTY LINE
TELEPHONE
VAULT/HANDHOLE
=)
ELECTRIC VAULT/HANDH❑LE
— — - — — — — — —
EASEMENT
TELEPHONE
CABINET
Q
ELECTRIC MANHOLE
CURB & GUTTER
®r
TELEPHONE
MANHOLE
B
ELECTRIC J-B❑X
H FH F ++i+�L Fi+-H+I l+ tT#i F1 1 tH+H+h
RAILR❑AD
®
TELEPHONE
COOL PED
®
SEWER MANHOLE
FENCE
iXl
TELEPHONE
SAI
®
STORM BRAIN CATCH BASIN
X X X X
--- - - -TEL -- - -TEL- - - -TEL
TELCO
sA
TELEPHONE
USAM
®STORM
DRAIN INLET
ELEC
ELECTRIC
Q
TELEPHONE
OWNED POLE
®
SEWER DRAIN MANHOLE
CATV
CATV
®
JOINT USE
POLE
C/L MONUMENT
GAS
CATV BULLET
PEDESTAL
®
POLE ITEM NO.
- TRAFFIC
TRAFFIC SIGNAL
Tv
CATV PED
WATER WATER
WATER
FTT7,
CATV VAULT/HANDH❑LE
SEWER SEWER
SEWER
STORM STORM
STORM
IRRIG IRRIG
IRRIGATION
PR❑P❑SED EQUIPMENT LEGEND
- - - - - - - - - - - - - - - - PARKWAY TRENCH
All Underground Utility Locations Shown Hereon Are
Approximate. Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
AERIAL BUILD
AERIAL BUILD
SLACK SPAN
AERIAL STRAND
CALL TWO WORKING DAYS
BEFORE YOU DIG
U811
® 2'x2' RECEIVING PIT
® 4'x4' RECEIVING PIT
1X1 SAI
�] COOL PEDESTAL
ELECTRIC PEDESTAL
[7) TELCO HANDHOLE
Z TELCO PEDESTAL
[ T_] TELCO CABINET
TELCO MANHOLE
GAS METER
GAS VALVE
0 WATER METER
® WATER VALVE
FIRE HYDRANT
O WATER MANHOLE
0 IRRIGATI❑N METER
9 IRRIGATION VALVE
�- -< CULVERT
rs TRAFFIC SIGNAL VAULT/HANDH❑LE
Q TRAFFIC SIGNAL POLE
d STREETLIGHT
>�-- ANCHOR & DOWN GUY
-a DOWN GUY
<2xx!> ASPHALT TRENCH FOOTAGE
xxx• DIRT OR S/W TRENCH FOOTAGE
xxx' BORE FOOTAGE
xxx AERIAL FOOTAGE
FIELD ENGINEER: CORY COATE
(503)-961-5023
TOWN: RANGE: SECT:
23N 5E 1 19
NOTICE - NOT FOR DISCLOSURE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
JOB: N.237645
333 SW. 7TH STREET
RENTON, WA 98057 GEO CODE:
WC CLLI: RNTNWA01
PLOTTED: 04/11/2017 BY: SARAH THATCHER I DRAFTED BY: KILLION COMM. f SH 2 OF 3
—R/W—
ECP EdP - EDP
C/L C/L —
76'
— R/W—
C/L
-- ELIP EDP —
SID
-CTL TO ACCESS MH113 TO PUSH
FIBER COUNT LRE28, 3-4 AND TO
PL 24CT FIBER TO CUST BLDG
-PL 274' OF 1-1/4" INNERDUCT AND
24CT FIBER FROM MH113 TO BLDG MPOP
CenturyLink-
CM p
o
o
+LO
O Q
O p
H
,S#r 7TH ,ST
C/L C/L C/L C/L -
All Underground Utility Locations Shown Hereon Are
Approximate. Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
CALL TWO WORKING DAYS
BEFORE YOU DIG
811
PLOTTED: 04/11/2017 BY: SARAH THATCHER
C/L
24' CTL DUCT
FIELD ENGINEER: CORY COATE
(503)-961-5023
TOWN: RANGE: SECT:
23N 5E 19
NOTICE - NOT FOR DISCLOSURE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
JOB: N.237645
333 SW. 7TH STREET
GEO CODE:
RENTON, WA 98057
WC CLLI: RNTNWA01
DRAFTED BY: KILLION COMM. SH 3 OF 3