Loading...
HomeMy WebLinkAboutP_CAD_N.265866_170823_v1CONSTRUCTION NOTES, 1, CALL UTILITY LOCATE AT 811 72 HOURS PRI❑R TO PERMITS TRENCHING TRENCHING OR DIGGING, AND LOCATION OF VICINITY MAP YES/NO 2, THE EXISTENCE ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF DESIGNED SERVICES: ❑ THE AVAILABLE CITY OR COUNTY RECORDS, SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT ❑ HELD ORDERS: SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO EXCAVATION. 3. FOR UNDERGROUND ACTIVITY, TEST AND VENTILATE ROW REQUIRED: ❑ MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND 110 EYE AND HEAD SAFETY PROTECTION PER FEDERAL, � CITY: ® El STATE, AND LOCAL REGULATIONS, 4. ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE CODE OF FEDERAL RE5LILAIIOUS (CER) 1926,650 WORK LOCATION STHE UBPART R t+ )ostaid's 0 m 4621 NE SUNSET BLVD COUNTY: a, PR❑VIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF OHoneyCreekApartment EXCAVATION FOR TECHNICIAN INGRESS/EGRESS, ❑ lo, EXCAVATED SP❑ILS ARE TO BE NO LESS THAN 24' EDGE OF STATE: PIT OR TRENCH, c, BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL BARRICADES MUST BE EQUIPPED WITH FLASHING Q Redbox0 0 RAILROAD: ❑ LIGHTS FOR NIGHT VISIBILITY. Big Lots 0 Coinsta d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE Highlands Ace iardwafe aF 12th St SHORING FOR WALL STABILITY.1 11 1583 Planet Fitness0 AlbeMsons ® © c LOOP QUAL.: ❑ 5. TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS, m DEBRIS, AND CLODS. THE TRENCH IS TO BE A MINIMUM OF n 36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF Renton Highlands `m ❑ COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE KinderCareo x• Z m PREMIS FORM: STANDARDS WILL BE SPECIFIED ON THE PLANS.) M 1 N 6, ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, s ® ❑ DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION r CONFORMANCE TEST: SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER, s SEE NDS 7. 8. NORMAL/GUIDED-B❑RING METHOD RECOMMENDED WHEN B❑RING, ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED,HH MH437 o z z 1-25 HH UN 156 HH UN9 �9 9. BOND BURIED/AERIAL FACILITIES AS REQUIRED BY - JURISDICTIONAL AGENCY(S), NE 121h St NE 12th St NE 121h St ERFS DATE: 10. AERIAL FACILITIES ARE TO BE TESTED PRI❑R TO BEGINNING WORK PER STATE AND LOCAL REGULATIONS. NE 12th St NE 12th St z TRENCH OPEN DATE: 11, ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO m BE WITH APPROVED WARNING DEVICES AND PLACED PER APPROVED MNEMONICS: STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC ` ASSOCIATED PROJECTS: WORKS ENGINEERING DEPARTMENT STANDARDS AND The venue y SPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN Apartment Homes m SHALL BE SUBMITTED TO THE REQUESTING PERMITTING 0 Kingdom Hadi of D `° LCON NAME AND NUMBER: AGENCY, PRIOR TO BEGINNING WORK, PERMITTING AGENCIESJehovahswitnesses MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION m SANDY RHINEHART 206-510-2228 ACTIVITIES. 12, EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY, FIBER ENGINEER: TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE MIKE GILLIAM DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS. 13. THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE CUSTOMER NAME: VERIFIED PRIOR TO CONSTRUCTION. SAFEWAY, INC. SCOPE OF WORK: PLACE FDP AND CIENA ON B.B. IN MPOP ON EAST WALL IST FLOOR FIBER: POF: MH 437-1 LRE23, 343-344 /PLACE NEW 24CT FROM MH 437-1 THRU MH 583, THRU HH 1-25, THRU HH UN -156, THRU HH UN9 TO CUST MPOP OUT OF MH 437 PLACE A BORE PIT TO BORE NORTH ON THE WEST SIDE OF ANACORTES. JUST ACROSS THE STREET FOR HH583. PLACE RELIVING PIT. NEXT TO HH583 AL.50 PLACE A RECIVING PIT TO TIE NEW 4" INTO HH. ****THE CBO RUN LOOKS ROUGH PLEASE SEE PICS BELOW OF ALL HAND HOLES. All Underground Utility Locations Shown Hereon Are Approximate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities 1CenturyLink-- CUSTOMER:: ID SAY THEY NEED TO PROVE THE CBO PATH DUE TO THE CONDITIONS FROM THE SURFACE. CALL TWO WORKING DAYS BEFORE YOU DIG 811 PLOTTED: 06/26/2017 BY: SARAH THATCHER 4621 NE SUNSET BLVD RENTON, WA 98059 DRAFTED BY: KILLION COMM. ADDRESS: 4621 NE SUNSET BLVD RENTON, WA 98059 FIELD ENGINEER: PATRICK MARKS (503)-347-1137 TOWN: I RANGE: I SECT: 23N 5E 3,10 JOB: N.265866 GEO CODE: WC CLLI: RNTNWA01 SH 1 OF 3 AERIAL LEGEND ANC ANCH❑R CA ARM CABLE ARM CATV CABLE TV DG DOWN GUY DGA DOUBLE GUARD ARM FGA FIBER GLASS ARM F/S FIELD SIDE GA GUARD ARM HOA HEIGHT OF ATTACHMENT M/R MAKE READY OHG OVERHEAD GUY R/S ROAD SIDE SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER SWA SIDEWALK ANCHOR AND GUY T TELEPHONE TERM TERMINAL TRANS TRANSFORMER TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP CURB & GUTTER SECONDARY POWER CABLES AND/OR TOP OF RISER TELEPHONE CABLES S❑ PROPOSED CABLE CAN BE ATTACHED B WITHOUT VIOLATING THE 40' RULE. CABLE TF ARM ATTACHMENT L❑CATI❑Ni TOP FIELD SIDE TS TOP STREET SIDE TIP TOP INSIDE POSITION TIS TOP INSIDE STREET SIDE TMP TOP MIDDLE P❑SITI❑N TOP TOP OUTSIDE POSITION TOS TOP OUTSIDE STREET SIDE BF BOTTOM FIELD SIDE BS BOTTOM STREET SIDE BIP BOTTOM INSIDE P❑SITI❑N BIS BOTTOM INSIDE STREET SIDE BMP BOTTOM MIDDLE POSITION BOP BOTTOM OUTSIDE POSITI❑N BOS BOTTOM OUTSIDE STREET SIDE 1 w W'- � '�qw CenturyLink­ EXISTING EQUIPMENT LEGEND PROPOSED EQUIPMENT LEGEND - - - - - - - ---- - --- PARKWAY TRENCH t����������������i����*��� AERIAL BUILD AERIAL BUILD - SLACK SPAN All Underground Utility Locations Shown Hereon Are Approximate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities AERIAL STRAND r CALL TWO WORKING DAYS BEFORE YOU DIG 811 ® 2'x2' RECEIVING PIT ® 4'x4' RECEIVING PIT Fix -1 SAI ® COOL PEDESTAL [� ELECTRIC PEDESTAL HH TELCO HANDH❑LE ® TELCO PEDESTAL TELCO CABINET ® TELCO MANHOLE PLOTTED: 0612612017 BY: SARAH THATCHER GAS METER GAS VALVE 0 WATER METER ® WATER VALVE -& FIRE HYDRANT Qw WATER MANHOLE 0 IRRIGATI❑N METER 0 IRRIGATION VALVE )--� CULVERT TRAFFIC SIGNAL VAULT/HANDHOLE TRAFFIC SIGNAL POLE STREETLIGHT >.--- ANCHOR & DOWN GUY DOWN GUY xxx' ASPHALT TRENCH FOOTAGE rx-R-71 DIRT OR S/W TRENCH FO❑TAGS xxx BORE FOOTAGE xxx' AERIAL FOOTAGE 4621 NE SUNSET BLVD RENTON, WA 98059 DRAFTED BY: KILLION COMM. JOB: N.265866 GEO CODE: WC CLLI: RNTNWA01 SH2 OF3 EDGE OF PAVEMENT ® TELEPHONE BULLET PEDESTAL 0 ELECTRIC PEDESTAL/CABINET C/L CENTERLINE ® TELEPHONE REPEATER PwR ELECTRIC TRANSFORMER -R/W- -R/W- RIGHT OF WAY ® TELEPHONE PEDESTAL ELECTRIC METER P/L PROPERTY LINE HH TELEPHONE VAULT/HANDH❑LE ELECTRIC VAULT/HANDHOLE — — — — — — — — — — EASEMENT TELEPHONE CABINET Qr ELECTRIC MANHOLE - --. CURB & GUTTER ® TELEPHONE MANHOLE B ELECTRIC J -BOX 'r-+ +H -j 4-H+I4W-i1 11 1 1 i 11 1 11 i 1 f fiH FH 1 RAILROAD ® TELEPHONE COOL PED SEWER MANHOLE --)4�_- - X X -.--X-----X-- X FENCE IXI TELEPHONE SAI ® STORM DRAIN CATCH BASIN - -TEL- - - -TEL- - - -TEI— TELCO sA TELEPHONE USAM STORM DRAIN INLET - ELEC ELECTRIC Q TELEPHONE OWNED POLE ® SEWER DRAIN MANHOLE CATV CATV ® JOINT USE POLE OO C/L MONUMENT GAS ® CATV BULLET PEDESTAL Cx7 POLE ITEM NO. TRAFFIC SIGNAL Tv CATV PED WATER WATER WATER Tv CATV VAULT/HANDHOLE SEWER SEWER SEWER TRANSFORMER POLE STORM STORM STORM IRRIG IRRIG IRRIGATION PROPOSED EQUIPMENT LEGEND - - - - - - - ---- - --- PARKWAY TRENCH t����������������i����*��� AERIAL BUILD AERIAL BUILD - SLACK SPAN All Underground Utility Locations Shown Hereon Are Approximate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities AERIAL STRAND r CALL TWO WORKING DAYS BEFORE YOU DIG 811 ® 2'x2' RECEIVING PIT ® 4'x4' RECEIVING PIT Fix -1 SAI ® COOL PEDESTAL [� ELECTRIC PEDESTAL HH TELCO HANDH❑LE ® TELCO PEDESTAL TELCO CABINET ® TELCO MANHOLE PLOTTED: 0612612017 BY: SARAH THATCHER GAS METER GAS VALVE 0 WATER METER ® WATER VALVE -& FIRE HYDRANT Qw WATER MANHOLE 0 IRRIGATI❑N METER 0 IRRIGATION VALVE )--� CULVERT TRAFFIC SIGNAL VAULT/HANDHOLE TRAFFIC SIGNAL POLE STREETLIGHT >.--- ANCHOR & DOWN GUY DOWN GUY xxx' ASPHALT TRENCH FOOTAGE rx-R-71 DIRT OR S/W TRENCH FO❑TAGS xxx BORE FOOTAGE xxx' AERIAL FOOTAGE 4621 NE SUNSET BLVD RENTON, WA 98059 DRAFTED BY: KILLION COMM. JOB: N.265866 GEO CODE: WC CLLI: RNTNWA01 SH2 OF3 PLACE UP1248 I BORE PIT BORE PIT MH437 ELIP d W COULD NOT OPEN THIS HH NO HANDLES BORE PIT � I I 3 d' I E+ 5' �E E 5' -780' TOTAL FIBER -PERMIT FOR MH 437 i Eh w ALBERTSONSISAFEWAY I I C BIG LOT'S PLANET FITNESS 1 4621 NE SUNSET BLVD w PLACE 24X FIBER E1W 1-1.25" I.D. IN EXISTING 4" CBO 540' HH 1-25 HH UN156 THIS HH IS CRUSHED THIS HH IS STUCK AND FULL OF WATER SHUT le N M a U N —C/L— —C/L— —CIL— BORE AND PLACE 4" CONDUIT E1W 3-1.25" I.D. �I E� 5' AND 24X FIBER 200' It- 22' --- IN—i ACCESS TO APARTMENTS CenturyLink- All Underground Utility Locations Shown Hereon Are Approximate.Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities (SEE PIC'S ABOUT H.H.-S) N'' I,?T'ff ,ST — —C/L——CIL— PLOTTED: 06/2612017 BY: SARAH THATCHER HH UN9 THIS HH LOCKS WOULD NOT RELEASE (DIFFERENT MODEL) le 0 H U) —CIL— —C/L- M PO P I STA.7+40 J Y 4621 NE SUNSET BLVD RENTON, WA 98059 DRAFTED BY: KILLION COMM. FIELD ENGINEER: PATRICK MARKS TOWN: 23N (503)-347-1137 RANGE: SECT: 5E 3,10 JOB: N.265866 � WC CLLI: RNTNWA01 3 SH3 OF I I " 3 I N 3 w I � I 65' 3 DRIVEWAY I / STA_1+59 f HH583 r PLACE UP1248 I BORE PIT BORE PIT MH437 ELIP d W COULD NOT OPEN THIS HH NO HANDLES BORE PIT � I I 3 d' I E+ 5' �E E 5' -780' TOTAL FIBER -PERMIT FOR MH 437 i Eh w ALBERTSONSISAFEWAY I I C BIG LOT'S PLANET FITNESS 1 4621 NE SUNSET BLVD w PLACE 24X FIBER E1W 1-1.25" I.D. IN EXISTING 4" CBO 540' HH 1-25 HH UN156 THIS HH IS CRUSHED THIS HH IS STUCK AND FULL OF WATER SHUT le N M a U N —C/L— —C/L— —CIL— BORE AND PLACE 4" CONDUIT E1W 3-1.25" I.D. �I E� 5' AND 24X FIBER 200' It- 22' --- IN—i ACCESS TO APARTMENTS CenturyLink- All Underground Utility Locations Shown Hereon Are Approximate.Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities (SEE PIC'S ABOUT H.H.-S) N'' I,?T'ff ,ST — —C/L——CIL— PLOTTED: 06/2612017 BY: SARAH THATCHER HH UN9 THIS HH LOCKS WOULD NOT RELEASE (DIFFERENT MODEL) le 0 H U) —CIL— —C/L- M PO P I STA.7+40 J Y 4621 NE SUNSET BLVD RENTON, WA 98059 DRAFTED BY: KILLION COMM. FIELD ENGINEER: PATRICK MARKS TOWN: 23N (503)-347-1137 RANGE: SECT: 5E 3,10 JOB: N.265866 GEO CODE: WC CLLI: RNTNWA01 SH3 OF