HomeMy WebLinkAboutP_CAD_N.257439_170601_v1CONSTRUCTION NOTES, L CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING. 2. THE EXISTENCE AND L❑CATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO EXCAVATION. 3. FOR UNDERGROUND ACTIVITYt TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS. 4. ALL EXCAVATION, TRENCHING, AND SH❑RING IS TO ADHERE TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926,65.0 SUBPART P, n, PR❑VIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS. b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24' EDGE OF PIT OR TRENCH, c, BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY, ALL BARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY. d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL. STABILITY. 5. TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS. THE TRENCH IS TO BE A MINIMUM OF 36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE STANDARDS WILT_ BE SPECIFIED ON THE PLANS.) 6. ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. 7. NORMAL/ GUIDED -BORING METHOD RECOMMENDED WHEN BORING. 8. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED. 9. BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S). 10. AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING WORK PER STATE AND LOCAL REGULATIONS. 11. ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO BE WITH APPROVED WARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS, IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTED TO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK, PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION ACTIVITIES. 12. EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS. 13. THE FOLLOWING FOOTAGES ARE ESTIMATES, F❑0TAGES TO BE VERIFIED PRIOR TO CONSTRUCTION. King Conservation District O LP sOf d �a ooh � �o SW 16th St G > o .Q x dpi rr, 0 VICINITY MAP Cummins Sales and Service aos 0 Shuttle Express 0 Lowe's Regional Office FWsiness Office SW 16th S1 SW 16t MH T129 HH1054 awn Food Products WORK LOCAON 1101 SW 16TI-IfST 5�. Jul Q) � a f Q � IlkPr SCOPE OF WORK: THIS JOB WILL NEW EQUIPMENT AT 1101 SW 16TH ST, RENTON PLEASE NOTE, THE RECORDS ARE INCORRECT AND THIS JOB WILL REQUIRE ROD AND PROOF FROM THE CUSTOMERS MPOP WORKING TOWARDS THE C.Q. TO MH -T129. FIBER: CTL WILL ACCESS POF MH -T129 VAULT SHOWN ON CAD DRAWING. CTL WILL PLACE APPROX. 687 FEET OF 1-1/41NCH INNERDUCT AND FIBER OUT OF POF VAULT TO CUSTOMERS BLDG'S MPOP. • LRE13, 9-10 NOTE, CUST CLEAR PATH IS APPROX. 75 FEET IN THE ROOM NEXT TO THE MPOP. PATH WILL BE PROVIDED DURING BUILDING CONSTRUCTION REMODEL. PLEASE NOTE, PLANNERS NOTES ADDED BELOW FOR REFERENCE: POF MH T129 LRE13, 9-10 / PLACE NEW 24CT FROM MH 129 TO OUST MPOP, NEED TO FIND BEST PATH. �0 r� A ►7 CenturyLink- All Underground Utility Locations Shown Hereon Are Approximate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities WILMARI RMANCETOOL Q Click Wholesale O Distributing N PERMITS YES/NO DESIGNED SERVICES: ❑ HELD ORDERS: ❑ ROW REQUIRED: ❑ CITY: ® ❑ COUNTY: ❑ STATE: ❑ CUSTOMER: CUSTOMER WILL WANT TO PROVIDE NEW 2'X4' 3/41NCH BACK BOARD ON EAST WALL ALONG WITH NEW POWER. FIELD VERIFIED 1-41NCH CONDUIT IN THE MPOP, FIELD WAS NOT ABLE TO VERIFY CONDUIT IN THE ROW SERVING HAND HOLE 1054. PLEASE NOTE, THE RECORDS ARE IN CORRECT AND THIS JOB WILL REQUIRE ROD AND PROOFING CTL CONDUIT AND CSO CONDUIT STARTING FROM THE MPOP AND WORKING TOWARDS THE C.O. CTL CREWS WILL PLACE 1-1/41NCH INNERDUCT FROM SERVING HAND HOLE TO THE MPOP APPROX. 243 FEET. CALL TWO WORKING DAYS BEFORE YOU DIG 811 PLOTTED: UB11112U11 BY: SARAH 1HA1C:HER 1101 SW 16TH ST RENTON, WA 98057 DRAFTED BY: KILLION COMM. ERFS DATE: TRENCH OPEN DATE: APPROVED MNEMONICS: ASSOCIATED PROJECTS: LCON NAME AND NUMBER: KELLI BAYS 206-573-1204 FIBER ENGINEER: MICHAEL GILLIAM CUSTOMER NAME: AMAZON CUSTOMER ADDRESS: 1101 SW 16TH ST RENTON, WA 98057 FIELD ENGINEER: CORY COATE (503)-961-5023 TOWN: RANGE: SECT: 23N I 4E 1 24 JOB: N.257439 GEO CODE: WC CLLI: RNTNWA01 SH1 OF RAILROAD: ❑ N LOOP QUAL.: ❑ N SW 16 PREMIS FORM: ❑ N CONFORMANCE TEST: ® ❑ SEE NDS CUSTOMER: CUSTOMER WILL WANT TO PROVIDE NEW 2'X4' 3/41NCH BACK BOARD ON EAST WALL ALONG WITH NEW POWER. FIELD VERIFIED 1-41NCH CONDUIT IN THE MPOP, FIELD WAS NOT ABLE TO VERIFY CONDUIT IN THE ROW SERVING HAND HOLE 1054. PLEASE NOTE, THE RECORDS ARE IN CORRECT AND THIS JOB WILL REQUIRE ROD AND PROOFING CTL CONDUIT AND CSO CONDUIT STARTING FROM THE MPOP AND WORKING TOWARDS THE C.O. CTL CREWS WILL PLACE 1-1/41NCH INNERDUCT FROM SERVING HAND HOLE TO THE MPOP APPROX. 243 FEET. CALL TWO WORKING DAYS BEFORE YOU DIG 811 PLOTTED: UB11112U11 BY: SARAH 1HA1C:HER 1101 SW 16TH ST RENTON, WA 98057 DRAFTED BY: KILLION COMM. ERFS DATE: TRENCH OPEN DATE: APPROVED MNEMONICS: ASSOCIATED PROJECTS: LCON NAME AND NUMBER: KELLI BAYS 206-573-1204 FIBER ENGINEER: MICHAEL GILLIAM CUSTOMER NAME: AMAZON CUSTOMER ADDRESS: 1101 SW 16TH ST RENTON, WA 98057 FIELD ENGINEER: CORY COATE (503)-961-5023 TOWN: RANGE: SECT: 23N I 4E 1 24 JOB: N.257439 GEO CODE: WC CLLI: RNTNWA01 SH1 OF AERIAL LEGEND ANC ANCHOR CA ARM CABLE ARM CATV CABLE TV DG DOWN GUY DGA DOUBLE GUARD ARM FGA FIBER GLASS ARM F/S FIELD SIDE GA GUARD ARM HOA HEIGHT OF ATTACHMENT M/R MAKE READY ❑HG OVERHEAD GUY R/S ROAD SIDE SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER SWA SIDEWALK ANCHOR AND GUY T TELEPHONE TERM TERMINAL TRANS TRANSFORMER TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP SECONDARY POWER CABLES AND/OR TOP OF RISER CABLES SO PROPOSED CABLE CAN BE ATTACHED WITHOUT VIOLATING THE 40' RULE, CABLE ARM ATTACHMENT LOCATION, TF TOP FIELD SIDE TS TOP STREET SIDE TIP TOP INSIDE POSITION TIS TOP INSIDE STREET SIDE TMP TOP MIDDLE POSITION TOP TOP OUTSIDE POSITION TOS TOP OUTSIDE STREET SIDE BF BOTTOM FIELD SIDE BS BOTTOM STREET SIDE BIP BOTTOM INSIDE POSITI❑N BIS BOTTOM INSIDE STREET SIDE BMP BOTTOM MIDDLE POSITION BOP BOTTOM OUTSIDE POSITI❑N BOS BOTTOM OUTSIDE STREET SIDE CenturyLink-0 EXISTING EQUIPMENT LEGEND EDGE OF PAVEMENT (0 TELEPHONE BULLET PEDESTAL =) ELECTRIC PEDESTAL/ CABINET C/L CENTERLINE 6 TELEPHONE REPEATER PwR ELECTRIC TRANSFORMER -R/W- -R/W- RIGHT ❑F WAY ® TELEPHONE PEDESTAL CD ELECTRIC METER P/L PROPERTY LINE r HH TELEPHONE VAULT/HANDH❑LE ELECTRIC VAULT/HANDHOLE — — — — — — — — — — EASEMENT = TELEPHONE CABINET Q ELECTRIC MANHOLE CURB & GUTTER ® TELEPHONE MANHOLE B ELECTRIC J -BOX i H - H I-1-H--FH+1++i t I+ RAILR❑AD ® TELEPHONE COOL PED ® SEWER MANHOLE - FENCE IXI TELEPHONE SAI ® STORM DRAIN CATCH BASIN - - -TEL- - - -TEL- - - -TEL-- TELCO MR TELEPHONE USAM ®STORM DRAIN INLET ELEC ELECTRIC O TELEPHONE OWNED POLE ® SEWER DRAIN MANHOLE CATV CATV ® JOINT USE POLE OO C/L MONUMENT GAS ® CATV BULLET PEDESTAL ® POLE ITEM NO. - TRAFFIC TRAFFIC SIGNAL Tv CATV PED WATER WATER WATER Tv CATV VAULT/HANDH❑LE SEWER SEWER SEWER ® TRANSFORMER POLE STORM STORM STORM IRRIG IRRIG IRRIGATION ----------------- PARKWAY TRENCH i%/%///////// All Underground Utility Locations Shown Hereon Are Approxi mate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities AERIAL BUILD AERIAL BUILD SLACK SPAN AERIAL STRAND GAS METER GAS VALVE LA WATER METER ® WATER VALVE FIRE HYDRANT ® WATER MANHOLE Q IRRIGATION METER ® IRRIGATION VALVE >—< CULVERT Ts TRAFFIC SIGNAL VAULT/HANDH❑LE Q TRAFFIC SIGNAL POLE B STREETLIGHT PR❑PDSED EQUIPMENT LEGEND I CALL TWO WORKING DAYS BEFORE YOU DIG 811 PLOTTED: 08/1712017 BY: SARAH THATCHER ® 2'x2' RECEIVING PIT ® 4'x4' RECEIVING PIT Fix11SAI ® COOL PEDESTAL ELECTRIC PEDESTAL HH TELCO HANDHOLE ® TELCO PEDESTAL U TELCO CABINET ® TELCO MANHOLE >— ANCHOR & DOWN GUY .— DOWN GUY xxx' ASPHALT TRENCH FOOTAGE xxx' DIRT OR S/W TRENCH FOOTAGE xxx] BORE FOOTAGE xxx AERIAL FOOTAGE 1101 SW 16TH ST RENTON, WA 98057 DRAFTED BY: KILLION COMM. JOB: N.257439 GEO CODE: WC CLLI: RNTNWA01 SH 2 OF 3