Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P_CAD_N.284237_171006_v1
CONSTRUCTION NOTES: 1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING. 2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE ACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO EXCAVATION. 3. FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS. 4. ALL EXCAVATION. TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926.650 SUBPART P. a .PROVIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS. b .EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH. c BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL BARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILTY. d .FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY. 5. TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS. THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND A MINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE STANDARDS WILL BE SPECIFIED ON THE PLANS). 6. ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. 7. NORMAL/GUIDED—BORING METHOD RECOMMENDED WHEN BORING. 8. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED. 9. BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S). 10. AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING WORK PER STATE AND LOCAL REGULATIONS. 11. ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO BE WITH APPROVED WARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK, PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION ACTIVITIES. 12. EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANS SPECIFICATIONS. 13. THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIOR TO CONSTRUCTION. ESTIMATED TOTALS TOTAL EXISTING CONDUIT USED: 0 LF TOTAL NEW BORE: 0 LF TOTAL NEW DIRT TRENCH 25 LF TOTAL NEW S/W TRENCH 0 LF TOTAL NEW ASPHALT TRENCH 0 s�y TOTAL NEW AERIAL 0 LF SIDEWALK (PCC) R&R: 0 SF ASPHALT (AC) R&R 0 SF CDFS: YESN0: SCOPE OF WORK PLACE ONE NEW COOL PED AND ASSOCIATED CONDUITS Century Link 92 G� 4 S PUgei Dr m 4uge qr 5 S El A�9C+r Dr 4� rr a A cn m �o � s�y e CUSTOMER NAME: SERVICE ORDER: LCON: XXX LCON#: XXX 01 CALL TWO WORKING DAYS BEFORE YOU DIG 81 1 4v a uni con Automotive Seruieea Q P� RemeoCerper L 'n, a �o s�y WORK AREA VICINITY MAP Field Engineer: Jim Christian CTL En ineer: Leslie Ferguson I UvvN- Phone No:(253)720-9502 Phone 206)733-8862 23N NOTICE — NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT 21, 1500 BEACON WAY SE JOB: N.152423 RENTON, WA 98058 G E O CODE: W26226 Drafted by: Mountain LTD/SC WC CLLI: RNTNWA01 SH 1 OF 3 AERIAL LEGEND EXISTING EQUIPMENT LEGEND ANC ANCHOR - CENTERLINE TELEPHONE BULLET PEDESTAL ELECTRIC PEDESTAL/CABINET GAS METER o IRRIGATION METER CA ARM CABLE ARM —aw- -aw- -aw- -aw RIGHT OF WAY TELEPHONE REPEATER ELECTRIC TRANSFORMER GAS VALVE 0 IRRIGATION VALVE CATV CABLE TV —P•--P•--P, PROPERTY LINE TELEPHONE PEDESTAL Q ELECTRIC METER TRAFFIC SIGNAL VAULT/HANDHOLE >--< CULVERT DG DOWN GUY — — — — EASEMENT TELEPHONE VAULT/HANDHOLE O ELECTRIC VAULT/HANDHOLE TRAFFIC SIGNAL POLE C C/L MONUMENT DGA DOUBLE GUARD ARM 0. 0. em 0— EDGE OF PAVEMENT TELEPHONE CABINET O ELECTRIC MANHOLE o WATER METER XO POLE ITEM NO. FGA FIBER GLASS ARM — — — - CURB & GUTTER F(D-1 TELEPHONE MANHOLE 8 ELECTRIC J-BOX S WATER VALVE F/S FIELD SIDE RAILROAD ® TELEPHONE COOL PED d STREETLIGHT b FIRE HYDRANT GA GUARD ARM FENCE E TELEPHONE SAI ® CATV BULLET PEDESTAL © WATER MANHOLE HOA HEIGHT OF ATTACHMENT TELCO USAM TELEPHONE USAM 0 CATV PED STORM DRAIN CATCH BASIN M/R MAKE READY ELECTRIC O TELEPHONE OWNED POLE N CATV VAULT/HANDHOLE STORM DRAIN INLET OHG OVERHEAD GUY — — ^T —°^rv- CATV ® JOINT USE POLE D SEWER MANHOLE STORM DRAIN MANHOLE R/S ROAD SIDE GAS SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER — TRAFFIC SIGNAL SWA SIDEWALK ANCHOR AND GUY w w w WATER T TELEPHONE SEWER TERM TERMINAL STORM DRAIN TRANS TRANSFORMER ° a^° a^° as IRRIGATION TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP SECONDARY POWER CABLES AND/OR TOP OF RISER CABLES SO PROPOSED CABLE CAN BE ATTACHED WITHOUT VIOLATING THE 40" RULE CABLE ARM ATTACHMENT LOCATION: TF TOP FIELD SIDE PROPOSED EQUIPMENT LEGEND TS TOP STREET SIDE TIP TOP INSIDE POSITION PARKWAY TRENCH ❑ 2'x2' RECEIVING PIT ANCHOR & DOWN GUY ns TMP TOP INSIDE STREET SIDE TOP MIDDLE POSITION BORE Ll4'x4' BORE PIT iXi SAI XXX' DOWN GUY ASPHALT TRENCH FOOTAGE TOP TOP OUTSIDE POSITION ASPHALT TRENCH ® COOL PEDESTAL XXX' DIRT OR S/W TRENCH FOOTAGE TOS TOP OUTSIDE STREET SIDE I[ ELECTRIC PEDESTAL XXX' BORE FOOTAGE BF BOTTOM FIELD SIDE AERIAL BUILD T1 TELCO HANDHOLE XXX' AERIAL FOOTAGE BS BOTTOM STREET SIDE ,� AERIAL BUILD SLACK SPAN ® TELCO PEDESTAL BIP BOTTOM INSIDE POSITION L TELCO CABINET AERIAL STRAND BIS BOTTOM INSIDE STREET SIDE TO TELCO MANHOLE BMP BOTTOM MIDDLE POSITION BOP BOTTOM OUTSIDE POSITION BOS BOTTOM OUTSIDE STREET SIDE Field Enggineer: Jim Christian CTL En ineer: Leslie Ferguson TOWN: �RNGE: SECT: Phone No:(253)720-9502 Phone 206)733-8862 23N 5E 21 1 � enurLiV/A�� nk CALL TWO WORKING DAYS BEFORE YOU DIG g NOTICE - NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT 1500 BEACON WAY SE RENTON, WA 98058 JOB: N.152423 GEO CODE: W26226 WC CLLI: RNTNWA01 SH 2 OF 3 Drafted by: Mountain LTD/SC Century Link i SPEED / LIMIT 25 DRIVE E SE W U) I � J _J I J LU }� N O of !/r (<r(rr•-) hJl r�r � � p�1 GET 0 in �317297-166583 A0569061 02 NO W NO WORK POWER PED PL CE 6'-1-4" PVC FOR FIBER l y EXISTING CTL HH J w 3' PLACE 5'-1-4" PVC FOR FIBER LO TRAFFlC SPEED BARRIER LIMIT �c 25 0 EO`P 0 Z W W 0 eeqcoN W,� Y SE -PLACE 14'-1-2" PVC FOR POWER E� SAI PLACE 11'-1-4" PVC FOR COPPER NOTE: ACTUAL LOCATIONS OF THE NEW CONDUITS AND NEW COOL PED MAY VARY ONCE THE EXISTING UNDERGROUND STRUCTURES ARE LOCATED Field Engineer: Jim Christian CTL En ineer: Leslie Ferguson TOWN: RNGE: SECT. Phone No:(253)720-9502 Phone 206)733-8862 23N 5E 21 NOTICE — NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT CALL TWO WORKING DAYS BEFORE YOU DIG 1500 BEACON WAY SE JOB: N.152423 811 RENTON, WA 98058 G E O CODE: W26226 Drafted by: Mountain LTD/SC WC CLLI: RNTNWA01 SH 30F,3