Loading...
HomeMy WebLinkAboutMFP17004995DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP17004995 IVR Number: 17004995 Permit Informa!on Permit Name:Century Link Permits Address/Loca!on:10/24/2017Applica!on Date:1253810010Parcel Number:3401 LIND AVE SW Permit Type :11/02/2017Issue Date:Franchise Permit Work Class:11/02/2018Expira!on Date :Minor U(lity Job Number:N.307590Franchise Type :Telephone Descrip!on:Century Link to access MH373. No disturbance to surface. All other work to be performed on private property. Contacts Name Address PhoneTypeBilling C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Kim Parker QWest Corpora(on 931 14th St, SUITE 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky Communica(ons LLC 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: BL.036846Construc!on Contractor : NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing X General Condi!ons & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date MFP17004995 Scott Warlick 10/25/2017 Justin Johnson 11-1-2017 MFP17004995 Justin Johnson 11-1-2017 8:00 am to 3:00 pm Monday through Friday LIND AVE SW @ SW 34TH ST MH 373 Comments: ACCESS MH 373 LOCATED IN GRASS STRIP ON THE EAST SIDE OF LIND AVE SW, SOUTH OF SW 34TH ST. THIS IS A RIGHT LANE CLOSURE NORTHBOUND. TRAFFIC WILL SHIFT INTO THE LEFT LANE. SIDEWALK IS ACCESSIBLE SPOTTER WILL ASSIST PEDESTRIANS. SW 34TH ST SW 34TH ST TRAFFIC CONTROL PLAN JOB # N. 091350. C. 02 PERMIT # MH 373 ROAD WORK AHEAD W20-1 RIGHT LANE CLOSED AHEAD W20-5 W4-2 Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY TAPER 50' TO 100' max Comments: MERGING TAPER LENGTH TAPER ("L") LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac WORK AREA 10' X 200' N SPEED LIMIT 35 Legend Work Area WORK TRUCK CONES SPOTTER Arrowboard (Chevron) Designed For: CENTURYLINK Project # N. 091350.C.02 Kathy Hubbard Traffic Control Supervisor TCS # 008909 Approved 10/23/2017 Phone 253-737-5198 tcpnd@comcast.net _______________________ Date:10/23/2017 Author:Kathy Hubbard, Traffic Control Supervisor Project:N. 091350.C.02 CERT:TCS # 008909 Designed for CenturyLink:By Kathy Hubbard (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF AUBURN requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: KATHY HUBBARD, TCS# 008909, tcpnd@comcast.net LIND AVE SWwww.invarion.com ------------------- N.307590 MFP17004995 © 2017 HERE © 2017 Microsoft Corporation EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 30TOWNSHIP: 23NRANGE: 5ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: BADEN SPORTS, INCCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-563CONTRACT ENGINEERCHC ENGINEER: PAULINA MENDOZAPHONE: (619) 786-2017SCALE:JOB: N.307590DATE: 10/18/2017SHEET: OF 3ISSUE: 1RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 3401 LIND AVE SWCONSTRUCTION NOTES:1.CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES ORSTRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTIONAND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THEACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BESOMEWHAT DIFFERENT FROM THAT SHOWN. THE CONTRACTOR IS REQUIRED TOVERIFY PRIOR TO EXCAVATION.3.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULTPRIOR TO ENTRY. PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,AND LOCAL REGULATIONS.4.ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OFFEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.a. PROVIDE ALL PITS WITH 1'X1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c.BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL BARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY.d.FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY5.TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS.THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND AMINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESESTANDARDS WILL BE SPECIFIED ON THE PLANS).6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGESAS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITIONOR BETTER.7.NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE ANDLOCAL REGULATIONS.11.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVEDWARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATIONAND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANDSPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OFCONSTRUCTION ACTIVITIES.12.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINEDAT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS ANDWALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENTOF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENTSTANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIORTO CONSTRUCTIONS.PERMITSYES /NODESIGNED SERVICES:HELD ORDERS:ROW REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FORM:ADDITIONAL PERMIT INFO:CONFORMANCE TEST:SEE NDSERFS DATETRENCH OPEN DATE:----APPROVED MNEMONICS:ASSOCIATED PROJECTS:LCON NAME:GEROGIE HEATHLCON NUMBER:253-883-5112FIBER ENGINEER:VICTOR NOVELOFIBER ENGINEER CONTACT:(253) 372-563CUSTOMER NAME:BADEN SPORTS, INCADDRESS:3401 LIND AVE SW,RENTON, WA 98057EQUIPMENT: (1) ADTRAN TA3204, (1) 24 PORT FDP, (+/- 86’) PLENUM FIBERNARRATIVE: AT POF MH 373, PUSH COUNT LDMH373, 7 FROM EXISTING 24CT FIBER CABLE (PC-5B12LT-024) TO EXISTING 48CT FIBER CABLE (PC-5B12LT-048). COUNT FLOWS TO HH 542. AT HH 542, PULL NEW 1.25” CONDUIT WITH 24CT PLENUM FIBER FROM HH 542 TO CUSTOMER MPOPTHROUGH THE CUSTOMER CONDUIT (+/- 80’). SPLICE COUNT FROM EXISTING 48CT FIBER CABLE (PC-5B12LT-048) TO NEW 24CT PLENUM FIBER (UO24PL-I/O). COUNT FLOWS TO MPOP. PLACE NEW 24 PORT FDP AND ADTRAN TA3204 ON NEW WEST WALL BACKBOARD. SPLICE COUNT TO FDP.CUSTOMER REQUIREMENTS:CUSTOMER TO VERIFY OR PLACE CONDUIT FROM CUSTOMER PREMISES TO HH 542.CUSTOMER TO PLACE 4X4 BACKBOARD ON WEST WALL OF MPOP ROOM.CUSTOMER WILL PROVIDE CAT5 CABLE FROM MPOP TO SERVER ROOM (+/- 125’).VICINITY MAP1NTSRETAIL - IPCPOFCUSTOMERWORK AREASW 34TH STLIND AVE SW LIND AVE SW Splitter locationMFP17004995 EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 30TOWNSHIP: 23NRANGE: 5ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: BADEN SPORTS, INCCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-563CONTRACT ENGINEERCHC ENGINEER: PAULINA MENDOZAPHONE: (619) 786-2017SCALE:JOB: N.307590DATE: 10/18/2017SHEET: OF 3ISSUE: 1RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 3401 LIND AVE SW2C/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEANTSTELEPHONE BULLET PEDESTALTELEPHONE REPEATERTELEPHONE PEDESTALTELEPHONE VAULT/HANDHOLETELEPHONE CABINETTELEPHONE MANHOLETELEPHONE COOL PEDTELEPHONE SAITELEPHONE USAMTELEPHONE OWNED POLEJOINT USE POLEACCESS POINTAERIAL SPLICE CLOSUREELECTRIC PEDESTAL/CABINETELECTRIC TRANSFORMERELECTRIC METERELECTRIC VAULT/HANDHOLEELECTRIC MANHOLEELECTRIC J-BOXSTREETLIGHTCATV BULLET PEDESTALCATV PEDCATV VAULT/HANDHOLESEWER MANHOLEGAS METERGAS VALVETRAFFIC SIGNAL VAULT/HANDHOLETRAFFIC SIGNAL POLEWATER METERWATER VALVEFIRE HYDRANTWATER MANHOLESTORE DRAIN CATCH BASINSTORM DRAIN INLETSTORM DRAIN MANHOLEIRRIGATION METERIRRIGATION VALVECULVERTC/L MONUMENTPOLE ITEM NO.XXX'XXX'XXX'XXX'MHTHH HHEXAUSAMMHTHH HHEPWREEETVTVSVTSVWSDVCENTERLINERIGHT OF WAYPROPERTY LINEEASEMENTCURB & GUTTEREDGE OF PAVEMENTRAILROADFENCETELCOELECTRICCATVGASTRAFFIC SIGNALWATERSEWERSTORM DRAINIRRIGATIONANCHOR & DOWN GUYDOWN GUYASPHALT TRENCH FOOTAGEDIRT OR S/W TRENCH FOOTAGEBORE FOOTAGEAERIAL FOOTAGE2'x2' RECEIVING PIT4'x4' BORE PITSAICOOL PEDESTALELECTRIC PEDESTALTELCO HANDHOLETELCO PEDESTALTELCO CABINETTELCO MANHOLEPARKWAY TRENCHBOREASPHALT TRENCHAERIAL BUILDAERIAL BUILDSLACK SPANAERIAL STRANDR/WEOPTECATVGASTSWSSDC/LIRRIGMFP17004995 3400CUSTOMER:3401 LIND AVE SWEOPEOPEOPEOPEOPEOPEO P C/L C/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W C/LC/LC/LC/LC/LC/L C/LC/LC/LC/LC/LC/L EOPEOPEOPE O P EOPEOPEOPEOP C/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEOPEOPEOPEOPEOPC/LEOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSIDEWALKSIDEWALK SIDEWALKSIDEWALKD/WD/WD/WD/WD/WD/WSIDEWALKSIDEWALK SIDEWALKMPOP ROOMPOESW 34TH STLIND AVE SW 35SPEEDLIMIT25SPEEDLIMITR/WR/WR/WR/WR/WR/WR/WR/WR/WR /WP/LP/L P/L P/L P/LP/L P/L P/L P/L HH HHPARKING LOTPARKING LOTGRASSGRASS0+000+800+8680' 10' 11' 11' 11' 12' 5'PARKING LOTSIDEWALK SIDEWALK MH10'10'12'11'12'6'R/W R/W R/W R/W R/W R/WR/WR/WR/WR/W82'EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 30TOWNSHIP: 23NRANGE: 5ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: BADEN SPORTS, INCCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-563CONTRACT ENGINEERCHC ENGINEER: PAULINA MENDOZAPHONE: (619) 786-2017SCALE:JOB: N.307590DATE: 10/18/2017SHEET: OF 3ISSUE: 1RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 3401 LIND AVE SW31" = 50'FDP AND ADTRAN TO BE PLACEDON NEW WEST WALL BACKBOARDNew BackboardHH 542(15' from EOP)Pull new 1.25" ID through CBOwith new 24ct plenum fiber to customer premises (86').Customer to verify or place CBO from customer premises to HHPOFMH 373(18' from EOP)Existing FiberExisting 1x16 splitterMFP17004995