Loading...
HomeMy WebLinkAboutP_CAD_N.307590_171024_v1© 2017 HERE © 2017 Microsoft Corporation EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 30TOWNSHIP: 23NRANGE: 5ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: BADEN SPORTS, INCCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-563CONTRACT ENGINEERCHC ENGINEER: PAULINA MENDOZAPHONE: (619) 786-2017SCALE:JOB: N.307590DATE: 10/18/2017SHEET: OF 3ISSUE: 1RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 3401 LIND AVE SWCONSTRUCTION NOTES:1.CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES ORSTRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTIONAND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THEACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BESOMEWHAT DIFFERENT FROM THAT SHOWN. THE CONTRACTOR IS REQUIRED TOVERIFY PRIOR TO EXCAVATION.3.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULTPRIOR TO ENTRY. PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,AND LOCAL REGULATIONS.4.ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OFFEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.a. PROVIDE ALL PITS WITH 1'X1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c.BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL BARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY.d.FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY5.TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS.THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND AMINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESESTANDARDS WILL BE SPECIFIED ON THE PLANS).6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGESAS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITIONOR BETTER.7.NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE ANDLOCAL REGULATIONS.11.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVEDWARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATIONAND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANDSPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OFCONSTRUCTION ACTIVITIES.12.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINEDAT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS ANDWALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENTOF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENTSTANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIORTO CONSTRUCTIONS.PERMITSYES /NODESIGNED SERVICES:HELD ORDERS:ROW REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FORM:ADDITIONAL PERMIT INFO:CONFORMANCE TEST:SEE NDSERFS DATETRENCH OPEN DATE:----APPROVED MNEMONICS:ASSOCIATED PROJECTS:LCON NAME:GEROGIE HEATHLCON NUMBER:253-883-5112FIBER ENGINEER:VICTOR NOVELOFIBER ENGINEER CONTACT:(253) 372-563CUSTOMER NAME:BADEN SPORTS, INCADDRESS:3401 LIND AVE SW,RENTON, WA 98057EQUIPMENT: (1) ADTRAN TA3204, (1) 24 PORT FDP, (+/- 86’) PLENUM FIBERNARRATIVE: AT POF MH 373, PUSH COUNT LDMH373, 7 FROM EXISTING 24CT FIBER CABLE (PC-5B12LT-024) TO EXISTING 48CT FIBER CABLE (PC-5B12LT-048). COUNT FLOWS TO HH 542. AT HH 542, PULL NEW 1.25” CONDUIT WITH 24CT PLENUM FIBER FROM HH 542 TO CUSTOMER MPOPTHROUGH THE CUSTOMER CONDUIT (+/- 80’). SPLICE COUNT FROM EXISTING 48CT FIBER CABLE (PC-5B12LT-048) TO NEW 24CT PLENUM FIBER (UO24PL-I/O). COUNT FLOWS TO MPOP. PLACE NEW 24 PORT FDP AND ADTRAN TA3204 ON NEW WEST WALL BACKBOARD. SPLICE COUNT TO FDP.CUSTOMER REQUIREMENTS:CUSTOMER TO VERIFY OR PLACE CONDUIT FROM CUSTOMER PREMISES TO HH 542.CUSTOMER TO PLACE 4X4 BACKBOARD ON WEST WALL OF MPOP ROOM.CUSTOMER WILL PROVIDE CAT5 CABLE FROM MPOP TO SERVER ROOM (+/- 125’).VICINITY MAP1NTSRETAIL - IPCPOFCUSTOMERWORK AREASW 34TH STLIND AVE SW LIND AVE SW Splitter location EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 30TOWNSHIP: 23NRANGE: 5ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: BADEN SPORTS, INCCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-563CONTRACT ENGINEERCHC ENGINEER: PAULINA MENDOZAPHONE: (619) 786-2017SCALE:JOB: N.307590DATE: 10/18/2017SHEET: OF 3ISSUE: 1RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 3401 LIND AVE SW2C/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEANTSTELEPHONE BULLET PEDESTALTELEPHONE REPEATERTELEPHONE PEDESTALTELEPHONE VAULT/HANDHOLETELEPHONE CABINETTELEPHONE MANHOLETELEPHONE COOL PEDTELEPHONE SAITELEPHONE USAMTELEPHONE OWNED POLEJOINT USE POLEACCESS POINTAERIAL SPLICE CLOSUREELECTRIC PEDESTAL/CABINETELECTRIC TRANSFORMERELECTRIC METERELECTRIC VAULT/HANDHOLEELECTRIC MANHOLEELECTRIC J-BOXSTREETLIGHTCATV BULLET PEDESTALCATV PEDCATV VAULT/HANDHOLESEWER MANHOLEGAS METERGAS VALVETRAFFIC SIGNAL VAULT/HANDHOLETRAFFIC SIGNAL POLEWATER METERWATER VALVEFIRE HYDRANTWATER MANHOLESTORE DRAIN CATCH BASINSTORM DRAIN INLETSTORM DRAIN MANHOLEIRRIGATION METERIRRIGATION VALVECULVERTC/L MONUMENTPOLE ITEM NO.XXX'XXX'XXX'XXX'MHTHH HHEXAUSAMMHTHH HHEPWREEETVTVSVTSVWSDVCENTERLINERIGHT OF WAYPROPERTY LINEEASEMENTCURB & GUTTEREDGE OF PAVEMENTRAILROADFENCETELCOELECTRICCATVGASTRAFFIC SIGNALWATERSEWERSTORM DRAINIRRIGATIONANCHOR & DOWN GUYDOWN GUYASPHALT TRENCH FOOTAGEDIRT OR S/W TRENCH FOOTAGEBORE FOOTAGEAERIAL FOOTAGE2'x2' RECEIVING PIT4'x4' BORE PITSAICOOL PEDESTALELECTRIC PEDESTALTELCO HANDHOLETELCO PEDESTALTELCO CABINETTELCO MANHOLEPARKWAY TRENCHBOREASPHALT TRENCHAERIAL BUILDAERIAL BUILDSLACK SPANAERIAL STRANDR/WEOPTECATVGASTSWSSDC/LIRRIG 3400CUSTOMER:3401 LIND AVE SWEOPEOPEOPEOPEOPEOPEO P C/L C/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W C/LC/LC/LC/LC/LC/L C/LC/LC/LC/LC/LC/L EOPEOPEOPE O P EOPEOPEOPEOP C/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEOPEOPEOPEOPEOPC/LEOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPSIDEWALKSIDEWALK SIDEWALKSIDEWALKD/WD/WD/WD/WD/WD/WSIDEWALKSIDEWALK SIDEWALKMPOP ROOMPOESW 34TH STLIND AVE SW 35SPEEDLIMIT25SPEEDLIMITR/WR/WR/WR/WR/WR/WR/WR/WR/WR /WP/LP/L P/L P/L P/LP/L P/L P/L P/L HH HHPARKING LOTPARKING LOTGRASSGRASS0+000+800+8680' 10' 11' 11' 11' 12' 5'PARKING LOTSIDEWALK SIDEWALK MH10'10'12'11'12'6'R/W R/W R/W R/W R/W R/WR/WR/WR/WR/W82'EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 30TOWNSHIP: 23NRANGE: 5ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: BADEN SPORTS, INCCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-563CONTRACT ENGINEERCHC ENGINEER: PAULINA MENDOZAPHONE: (619) 786-2017SCALE:JOB: N.307590DATE: 10/18/2017SHEET: OF 3ISSUE: 1RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 3401 LIND AVE SW31" = 50'FDP AND ADTRAN TO BE PLACEDON NEW WEST WALL BACKBOARDNew BackboardHH 542(15' from EOP)Pull new 1.25" ID through CBOwith new 24ct plenum fiber to customer premises (86').Customer to verify or place CBO from customer premises to HHPOFMH 373(18' from EOP)Existing FiberExisting 1x16 splitter