HomeMy WebLinkAboutP_Traffic_Control_Plans_N.153292_171017_v1.pdfTRAFFIC CONTROL PLAN
JOB # N. 153292. C. 02
PERMIT #
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
ACCESS MH-T-131 LOCATED IN ROADWAY.
LANE-SHIFT WESTBOUND SW 16TH ST.
CENTER-LANE CLOSED EASTBOUND.
DRIVEWAY REMAINS OPEN/ACCESSIBLE.
PEDESTRIANS ARE NOT IMPACTED.
N
Date:10/16/2017 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 153292. C. 02
CERT:TCS # 008931 CENTURYLINK:Certified Traffic Control Plan [DO NOT ALTER]LOC::4097
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
tAPER 50' TO 100'max
Designed For: CENTURYLINK
Project # N. 153292. C. 02
Jeffrey D. Hubbard
Traffic Control Supervisor
TCS # 008931
Approved 10/16/2017
Phone 253-737-5198
jhubbard.tcp@gmail.com
_______________________
SW 16TH ST @ MAPLE AVE SW
MH-T-131 ACCESS
UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTER
THIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM:
JEFFREY D. HUBBARD, TCS# 008931, JHUBBARD.TCP@GMAIL.COM
LEGEND
CONES WORK AREA
WORK TRUCKDRIVEWAY W20-1ROADWORKAHEADLANESHIFTAHEADW20-1ROADWORKAHEADKEEPRIGHTWORK AREA
10' X 150'12121211111136
SIDEWALK
SIDEWALK W20-1ROADWORKAHEADSW 16TH ST
SW 16TH ST MAPLE AVE SWSPEED
LIMIT
35
WORK AREA
250' TOTAL
MH-T-131
ACCESS
SIDEWALKSIDEWALKSIDEWALK www.invarion.com
TRAFFIC CONTROL PLAN
JOB # N. 153292. C. 02
PERMIT #
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
Comments:
ACCESS MH-545, BORE TO POLE,
PLACE AERIAL DROP, & RESTORE.
THIS WILL BE SHOULDER WORK.
TRAFFIC FLOW IS NOT IMPACTED.
SPOTTER WILL ASSIST PEDESTRIANS.
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
tAPER 50' TO 100'max
Designed For: CENTURYLINK
Project # N. 153292. C. 02
Jeffrey D. Hubbard
Traffic Control Supervisor
TCS # 008931
Approved 10/16/2017
Phone 253-737-5198
jhubbard.tcp@gmail.com
_______________________
UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTER
THIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM:
JEFFREY D. HUBBARD, TCS# 008931, JHUBBARD.TCP@GMAIL.COM
LEGEND
BORE PIT CONES
S SPOTTER WORK AREA
WORK TRUCK
WORK AREA
8' X 40'
MH-545
ACCESS
SIDEWALK
SIDEWALK
SIDEWALKMAPLE AVE SW
SW 16TH ST361212
PARKINGSPEED
LIMIT
25SW 16TH STDEAD ENDSHOULDERWORKROADWORKAHEADNMAPLE AVE SW @ SW 16TH ST
MH-545 ACCESS / BORE / PLACE AERIAL / RESTORE
S
DRIVEWAYDRIVEWAYBORE
PLACE
AERIAL DROP
WORK AREA
8' X 40'
Date:10/16/2017 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 153292. C. 02
CERT:TCS # 008931 CENTURYLINK:Certified Traffic Control Plan [DO NOT ALTER]LOC::4097
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
www.invarion.com