HomeMy WebLinkAboutMFP17005292DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17005292
IVR Number: 17005292
Permit Informa!on
Permit Name:Century Link Permits
Address/Loca!on:11/08/2017Applica!on Date:0823059168Parcel Number:925 HOUSER WAY N
Permit Type :12/06/2017Issue Date:Franchise
Permit Work Class:12/06/2018Expira!on Date :Minor U)lity
Job Number:N.293131Franchise Type :Telephone
Descrip!on:Century Link to access HH's 800, 915, 919, and HH UKN, PED's 840, 820, 822, 824, and 830 to splice and place new
fiber. Excavate bore pit at HH 919 to bore new conduit and fiber to receiving pit then bore to new customer HH.
Restora)on per City of Renton standards . APPROVED WITH COMMENTS OR REDLINES
Contacts
Name Address PhoneTypeBilling
C/O QWEST CORP 1801 CALIFORNIA ST #4600
Denver, CO 80202
Applicant
Kim Parker
QWest Corpora)on
931 14th St, SUITE 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Heather Binkly
Dycom Industries dba North Sky Communica)ons LLC
11770 Us Hwy 1, SUITE 101
Palm Beach Gardens, FL 33408
B: (360) 254-6920
O: (360) 450-3287
Contractor
Business License Number: BL.036846Construc!on Contractor : NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
X
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
MFP17005292
Restoration per City of Renton Standards.
Scott Warlick 11/9/2017
Justin Johnson 11-27-2017
MFP17005292
Justin Johnson
11-27-2017
8:00 am to 3:00 pm
Monday through Friday
RRRRRRRRRRN 8TH ST
HOUSER WAY NHO
U
S
E
R
W
A
Y
B
Y
P
A
S
SHOUSER WAY NTRAFFIC CONTROL PLAN
JOB # N.293131 C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
Arrowboard (Chevron)
SPOTTER
WORK AREA
11' X 180'
HH 800 ROADWORKAHEADW20-1RO
A
D
WO
R
K
AH
E
A
D
W2
0
-
1 ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5RIGHT LANECLOSEDAHEADW20-5W4-2W4-2ROADWORKAHEADW20-1100'
100'
100'
100'
100'
100'
100'
Comments:
THIS IS TO ACCESS HH 800 LOCATED IN THE NORTH SIDE OF N 8TH ST
WEST OF HOUSER WAY N.
THIS IS A RIGHT LANE CLOSURE OF N 8TH ST WEST OF HOUSER WAY N.
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.
N 8TH ST @ HOUSER WAY N
HH 800 ACCESS
SPEED
LIMIT25
N
100'
www.invarion.com
MFP17005292
RRRRRRRRRRN 8TH ST
HOUSER WAY NHO
U
S
E
R
W
A
Y
B
Y
P
A
S
SHOUSER WAY NTRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
FLAGGER
ROAD
WORK
AHEAD
W20-1ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bBE
PREPARED
TO STOP
W20-7b
W20-7aW20-7aBE PREPAREDTO STOPW20-7bROADWORKAHEADW20-1W20-7aPEDESTAL
822
100'
100'
100'
100'
100'
100'
100'
100'100'
WORK AREA
10' X 100'
Comments:
THIS IS TO ACCESS PEDESTAL 822 LOCATED IN THE EAST SIDE
OF HOUSER WAY N NORTH OF N 8TH ST.
THIS IS A ONE LANE TWO WAY WITH FLAGGERS.
FLAGGERS WILL ASSIST PEDESTRIANS AT WORK AREA.
HOUSER WAY N @ N 8TH ST
PEDESTAL 822 ACCESS
SPEED
LIMIT25
N
www.invarion.com
MFP17005292
may need additional
signs
RRRRRRRRRRN 8TH ST
HOUSER WAY NHO
U
S
E
R
W
A
Y
B
Y
P
A
S
SHOUSER WAY NTRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
PEDESTAL
C820
ROAD
WORK
AHEAD
W20-1
SHOULDER
WORK
W21-5
NO
FROM
TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
SPEED
LIMIT25
N
WORK AREA
8' X 60'
Comments:
THIS IS TO ACCESS PEDESTAL C820 LOCATED IN THE EAST SIDE OF
HOUSER WAY N NORTH OF N 8TH ST.
THIS IS SHOULDER WORK.
PARKING RESTRICTED AT WORK AREA.
HOUSER WAY N @ N 8TH ST
PEDESTAL C820 ACCESS
ROADWORKAHEADW20-1100'
100'
100'
www.invarion.com
MFP17005292
TRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES HOUSER WAY NPEDESTAL C824
WORK AREA
8' X 60'
NO
FROM
TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
SPEED
LIMIT25
N
ROAD
WORK
AHEAD
SHOULDER
WORKROADWORKAHEAD100'
100'
100'
Comments:
THIS IS TO ACCESS PEDESTAL C824 LOCATED IN THE EAST SIDE OF
HOUSER WAY N NORTH OF N 8TH ST.
THIS IS SHOULDER WORK.
PARKING RESTRICTED AT WORK AREA.
HOUSER WAY N @ N 8TH ST
PEDESTAL C824 ACCESS
N 8TH ST
www.invarion.com
HOUSER WAY NN 8TH ST
TRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
PEDESTAL C830
WORK AREA
8' X 60'
NO
FROM
TO
TOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
SHOULDER
WORK
W21-5ROADWORKAHEADW20-1100'
100'
100'
ROAD
WORK
AHEAD
W20-1
Comments:
THIS IS TO ACCESS PEDESTAL C830 LOCATED IN THE EAST SIDE OF
HOUSER WAY N NORTH OF N 8TH ST.
THIS IS SHOULDER WORK.
PARKING RESTRICTED AT WORK AREA.
HOUSER WAY N @ N 8TH ST
PEDESTAL C830 ACCESS
www.invarion.com
MFP17005292
HOUSER WAY N
HOUSER WAY
NLAKE WASHINGTON BLVD NN 8TH S
T
TRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
PEDESTAL
C840
WORK AREA
8' X 60'
NO
FROM
TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
Comments:
THIS IS TO ACCESS PEDESTAL C840 LOCATED IN THE EAST
SIDE OF HOUSER WAY N NORTH OF N 8TH ST.
THIS IS SHOULDER WORK.
PARKING RESTRICTED AT WORK AREA.
SPEED
LIMIT25
N
ROAD
WORK
AHEA
D
W20-1
SHOU
L
D
E
R
WORK
W21-5ROADWORKAHEADW20-1100'
100'
100'
HOUSER WAY N @ N 8TH ST
PEDESTAL C840 ACCESS
www.invarion.com
MFP17005292
HOUSER WAY N
HOUSER WAY
NLAKE WASHINGTON BLVD NN 8TH S
T
TRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
CONES
WORK AREA
WORK AREA
8' X 60'
HH 915
ROAD
WORK
AHEA
D
W20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5100'
100'
100'
Comments:
THIS IS TO ACCESS HH 915 LOCATED IN THE WEST SIDE
OF HOUSER WAY N NORTH OF N 8TH ST.
THIS IS SHOULDER WORK.
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.
PARKING RESTRICTED AT WORK AREA.
NO
FROM
TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
SPEED
LIMIT25
N
HOUSER WAY N @ N 8TH ST
HH 915 ACCESS
www.invarion.com
MFP17005292
HOUSER WAY N
HOUSER WAY
NLAKE WASHINGTON BLVD NN 8TH S
T
TRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
SPOTTER
HH UNK
NO
FROM
TO
TOW AWAY AREA
PHONE 684-5444YOUR COMPANY NAME 555-5555
PARKING
R7-T39
WORK AREA
8' X 60'ROADWORKAHEADW20-1SHOULDERWORKW21-5ROAD
WORK
AHEAD
W20-1
100'
100'
100'
Comments:
THIS IS TO ACCESS HH UNK LOCATED IN THE WEST SIDE OF
HOUSER WAY N NORTH OF N 8TH ST.
THIS IS SHOULDER WORK.
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.
PARKING RESTRICTED AT WORK AREA.
SPEED
LIMIT25
N
HOUSER WAY N @ N 8TH ST
HH UNK ACCESS
www.invarion.com
MFP17005292
HOUSER WAY N
HOUSER WAY
NLAKE WASHINGTON BLVD NN 8TH S
T925HOUSER WAY NTRAFFIC CONTROL PLAN
JOB # N.293131.C.02
PERMIT #
Designed for: CENTURYLINK
Project # N.293131 C.02
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 10/17/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:10/17/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.293131 C.02
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
FLAGGER
HH 919
BORE PIT
BORE PIT
BORE
WORK AREA
+/- 175'NEW HH
PLACEMENT
WORK AREA
12' X 100'
ROAD
WORK
AHEAD
W20-1ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bBE
PREPARED
TO STOP
W20-7b
W20-7aW20-7a100'100'
100'
100'
100'
100'
Comments:
THIS IS TO ACCESS HH 919 LOCATED IN THE WEST SIDE OF
HOUSER WAY NORTH OF N 8TH ST, BORE FROM HH 919 TO
BORE PIT AT 925 HOUSER WAY N , PLACE NEW HH AND
RESTORE AS REQUIRED.
THIS IS A ONE LANE TWO WAY WITH FLAGGERS.
FLAGGERS WILL ASSIST DRIVEWAYS AND PEDESTRIANS AT
WORK AREA.
SPEED
LIMIT25
N
HOUSER WAY N @ N 8TH ST
BORE / HH 919 TO NEW HH PLACEMENT / RESTORE
www.invarion.com
MFP17005292
925N 8TH ST
2525HOUSER WAY
NDrafted by: Engineering Associates LLCSH OF 5 BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:”PLOTTED: 9/13/17 BY: QUAM, FRANCISVICINITY MAPAll underground utility locations shown hereon areapproximate. Construction contractor is responsiblefor the location of municipal and private utilities.23N05E081JOB#: N.293131WIRE CTR: RENTONWC CLLI: RNTNWA01SCOPE OF WORK:CUSTOMER:PERMITSDESIGNED SERVICES:YNHELD ORDERS:R.O.W. REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FROM:CONFORMANCE TEST:(SEE NDS)ERFS DATE:TRENCH OPEN DATE:APPROVED MNEMONICS:ASSOC. PROJECTS:LCON NAME: LORILCON PH#: (425) 226-6881FIBER ENGR: RYAN FLYNNFIBER PH#: (209) 663-9917NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTKELLER SUPPLY CO925 HOUSER WAY NRENTON, WA 98057INSTALL BACKBOARD.SPLICE FIBER AT HH800. PUSH COUNT THRU UNK HH#1, PED822, PEDC820, PEDC824, PEDC830, PEDC840, HH915, UNK HH#2 TO HH919. BORE 241' W/ (1) 2" PVC TO BLDG. PLACE17X30 HH. BUILD 10' RISER UP SIDE OF BLDG AND CORE HOLE THRU WALL. PLACE JUNCTION BOX OUTSIDE AND INSIDE BLDG. PLACE 100' 1.25" ID PLENUM FROM INSIDE JUNCTION BOX TO CUSTOMER MPOP/SERVER RM. PLACE 400' 24F FROM HH919 TOMPOP/SERVER RM IN NEW CLEAR PATH. PLACE & SPLICE NEW FDP & ONT. MFP17005292
301234SH OF 5 BEFORE YOU DIG811CALL TWO WORKING DAYSPLOTTED: 9/13/17 BY: QUAM, FRANCISDrafted by: Engineering Associates LLC2All underground utility locations shown hereon areapproximate. Construction contractor is responsiblefor the location of municipal and private utilities.NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB#: N.293131WIRE CTR: RENTONWC CLLI: RNTNWA01KELLER SUPPLY CO925 HOUSER WAY NRENTON, WA 98057MFP17005292
25N 8TH STHOUSER WAY N2580125HOUSER WAY NSH OF 5RNGE:SECT:TOWN: BEFORE YOU DIG811CALL TWO WORKING DAYSPLOTTED: 9/13/17 BY: QUAM, FRANCISMATCH TO RIGHT3Drafted by: Engineering Associates LLCNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMATCH TO LEFTMATCH TO PAGE 4 LEFT23N05E08JOB#: N.293131WIRE CTR: RENTONWC CLLI: RNTNWA01KELLER SUPPLY CO925 HOUSER WAY NRENTON, WA 98057MFP17005292
91525HOUSER WAY N92591925HOUSER WAY NRNGE:SECT:TOWN:SH OF 5 BEFORE YOU DIG811CALL TWO WORKING DAYSPLOTTED: 9/13/17 BY: QUAM, FRANCIS4Drafted by: Engineering Associates LLCNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMATCH TO SHEET 3 RIGHT23N05E08JOB#: N.293131WIRE CTR: RENTONWC CLLI: RNTNWA01KELLER SUPPLY CO925 HOUSER WAY NRENTON, WA 98057MATCH TO RIGHTMATCH TO LEFTMFP17005292may need to potholearound fire hydrantand water meter.
6"RNGE:SECT:TOWN:SH OF 5 BEFORE YOU DIG811CALL TWO WORKING DAYSPLOTTED: 9/13/17 BY: QUAM, FRANCIS5Drafted by: Engineering Associates LLCNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT23N05E08JOB#: N.293131WIRE CTR: RENTONWC CLLI: RNTNWA01KELLER SUPPLY CO925 HOUSER WAY NRENTON, WA 98057MFP17005292