Loading...
HomeMy WebLinkAboutP_CAD_N.317960_171208_v1© 2017 HERE © 2017 Microsoft Corporation MHHHHH HHHH HHHH MHEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/2017CONSTRUCTION NOTES:1.CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES ORSTRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTIONAND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THEACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BESOMEWHAT DIFFERENT FROM THAT SHOWN. THE CONTRACTOR IS REQUIRED TOVERIFY PRIOR TO EXCAVATION.3.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULTPRIOR TO ENTRY. PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,AND LOCAL REGULATIONS.4.ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OFFEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.a. PROVIDE ALL PITS WITH 1'X1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALLBARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY.d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY5.TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS.THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND AMINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESESTANDARDS WILL BE SPECIFIED ON THE PLANS).6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGESAS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITIONOR BETTER.7.NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE ANDLOCAL REGULATIONS.11.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVEDWARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATIONAND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANDSPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OFCONSTRUCTION ACTIVITIES.12.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINEDAT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS ANDWALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENTOF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENTSTANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIORTO CONSTRUCTIONS.PERMITSYES /NODESIGNED SERVICES:HELD ORDERS:ROW REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FORM:ADDITIONAL PERMIT INFO:CONFORMANCE TEST:SEE NDSERFS DATETRENCH OPEN DATE:----APPROVED MNEMONICS:ASSOCIATED PROJECTS:LCON NAME:MIKE PAYNELCON NUMBER:(425) 531-2836FIBER ENGINEER:VICTOR NOVELOFIBER ENGINEER CONTACT:(253) 372-5363CUSTOMER NAME:CINTASADDRESS:1001 SW 34TH ST,RENTON, WA 98057EQUIPMENT: (1) CIENA 3916, (1) 24 PORT FDP, (+/- 1361') 72CT MICRO-FIBER, (+/- 1361') 7 WAY FUTUREPATH, (+/- 261') 24CT TRANSITION FIBER, (+/- 261') 1.25" IDNARRATIVE: AT POF MH 265, PUSH COUNT LKO22, 573-574 FROM EXISTING 144CT FIBER [CYQ1] TO EXISTING 48CT CABLE [A0RN9] THAT FLOWS TO MH 387. AT MH 387, PUSH COUNT ONTO 72CT STUB [A31MK], PLACED BY JOB N.295278, THEN PUSH COUNT ONTOEXISTING 24CT FIBER [BD09] WHICH FLOWS THOUGH HH UN TO HH UN-106. AT HH-106, JET NEW FP WITH NEW 72CT MICRO-FIBER THOUGH EXISTING COPPER/FIBER OCCUPIED CONDUIT TO HH 454. AT HH-106, SPLICE COUNT ONTO NEW 72CT MICRO-FIBERCOUNT FLOWS TO HH 454. AT HH 454, PULL NEW 1.25" ID WITH NEW 24CT TRANSITION FIBER TO MPOP. AT HH 454 SPLICE COUNT FROM NEW 72 CT MF TO NEW 24CT TRANSITION FIBER. COUNT FLOWS TO MPOP. AT MPOP PLACE A NEW 24 PORT FDP AND A NEWCIENA 3916 ON EXISTING NORTH WALL CUSTOMER BACKBOARD. SPLICE COUNT TO FDP.CUSTOMER REQUIREMENTS: NONEVICINITY MAP1NTSWHOLESALE - CDFSCUSTOMER1001 SW 34TH STPOFMH 265OAKESDALE AVE SW WORK AREASW 43RD ST / S180TH STSW 34TH ST EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/20172C/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEANTSTELEPHONE BULLET PEDESTALTELEPHONE REPEATERTELEPHONE PEDESTALTELEPHONE VAULT/HANDHOLETELEPHONE CABINETTELEPHONE MANHOLETELEPHONE COOL PEDTELEPHONE SAITELEPHONE USAMTELEPHONE OWNED POLEJOINT USE POLEACCESS POINTAERIAL SPLICE CLOSUREELECTRIC PEDESTAL/CABINETELECTRIC TRANSFORMERELECTRIC METERELECTRIC VAULT/HANDHOLEELECTRIC MANHOLEELECTRIC J-BOXSTREETLIGHTCATV BULLET PEDESTALCATV PEDCATV VAULT/HANDHOLESEWER MANHOLEGAS METERGAS VALVETRAFFIC SIGNAL VAULT/HANDHOLETRAFFIC SIGNAL POLEWATER METERWATER VALVEFIRE HYDRANTWATER MANHOLESTORE DRAIN CATCH BASINSTORM DRAIN INLETSTORM DRAIN MANHOLEIRRIGATION METERIRRIGATION VALVECULVERTC/L MONUMENTPOLE ITEM NO.XXX'XXX'XXX'XXX'MHTHH HHEXAUSAMMHTHH HHEPWREEETVTVSVTSVWSDVCENTERLINERIGHT OF WAYPROPERTY LINEEASEMENTCURB & GUTTEREDGE OF PAVEMENTRAILROADFENCETELCOELECTRICCATVGASTRAFFIC SIGNALWATERSEWERSTORM DRAINIRRIGATIONANCHOR & DOWN GUYDOWN GUYASPHALT TRENCH FOOTAGEDIRT OR S/W TRENCH FOOTAGEBORE FOOTAGEAERIAL FOOTAGE2'x2' RECEIVING PIT4'x4' BORE PITSAICOOL PEDESTALELECTRIC PEDESTALTELCO HANDHOLETELCO PEDESTALTELCO CABINETTELCO MANHOLETRENCHBOREASPHALT TRENCHAERIAL BUILDAERIAL BUILDSLACK SPANAERIAL STRANDR/WEOPTECATVGASTSWSSDC/LP/LIRRIG S 180TH ST/ SW 43RD STC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEOPEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEO P EOPEOP EOPEOPEOPEOPEOPEO P EOP EOP C/L C/L C/L C/LC/LC/L R/WR/WR/WR/WR/WR/WR/WR/WR/W P/LP/LR/WR/WR/WR/WR/WR/W R/WR/W P/LP/LR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WD/WD/WD/WD/WD/WP/L P/LParcel #: 362304908679798009100012001250Parcel #: 3623049114Parcel #: 3623049108Parcel #: 3623049112Parcel #: 3623049100Parcel #: 3623049096D/WPOFMH 265(5' from EOP)35SPEEDLIMITMH35SPEEDLIMIT78'11'11'11'11'12'6'SidewalkSidewalkSidewalkSidewalkSidewalk Sidewalk Sidewalk 92'5'10'12'11'11'10'104'5'11'11'12'11'11'5' EOPEOP EOPEOPEOPEOPEOPEOP6'0+00OAKESDALE AVE SW TO MH 387 SEE SHEET 4Existing fiberEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201731" = 40' SW 41ST STC/LC/LC/LC/LC/LC/LC/LEOP EOPEOPEOPEOPEOPEOPEOPEOPR/W R/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPEOPEOPEOPEOP C/L C/L HHHH 25SPEEDLIMITHH UN(24' from EOP)No AccessEOPEOPEOPEOPEOPEOPEOPEO P EOPEOP OAKESDALE AVE SW SidewalkSidewalk Sidewalk Island D/WD/WD/WParcel #: 3623049001P/LP/L R/WR/WR/WR/WR/WR/WP/L R/W R/W R/WR/WR/WR/WR/WR/WR/WP/LP/LP/LP/LP/L35SPEEDLIMITParcel #:3623049104Parcel #: 36230490324001Parcel #: 3623049033Parcel #: 362304UNKNParcel #: 3623049109Parcel #: 36230491121001MATCH TO SHEET 5MATCH TO SHEET 41012101078' 10' 11' 10' 12' 6'8'11'13'12'10'6'94'12+23MH 387(17' from EOP)MHTO MH 265 SEE SHEET 3 Existing fiberExisting fiber10+91 EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201741" = 40' EOPEOPEOPEOP R/WR/WR/W EOPEOPEOPEOP C/L C/L C/L C/L C/L HH HHHH UN-106(24' from EOP & 70' from RR)OAKESDALE AVE SW EOP EOP EOP EOP EOP EOP EOP EOP C/LC/LC/LC/L C/LC/L C/L C/L Sidewalk D/WSidewalk 1012R/WR/WR/WR/WR/WR/W P/LP/LR/W R/W R/W R/WP/LP/LP/LP/LP/LP/L1010MATCH TO SHEET 5MATCH TO SHEET 4Parcel #: 3623049001Parcel #:3623049104Parcel #: 36230490324001Parcel #: 1253810390Parcel #: 1253810305P / L P / L P / L P / LP/LP/LP/LP / L P / L P / L P / LP/ L P/ L P / LP/ L P/ L Parcel #: 1253810060P a r c e l # : 1 2 5 3 8 1 U N K N P a r c e l # : 1 2 5 3 8 1UN KN Parcel #: 1253810240P a r c e l # : 2 5 2 3 0 4 9 0 5 4 35SPEEDLIMIT93'5'11'23'11'11'15+63Existing fiberJet new 7 way futurepath with new 72ct MFthrough existing copper/fiber occupied conduit to HH 454 (1361').TO HH 454SEE SHEET 6 EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201751" = 40' CUSTOMER:1001 SW 34TH STSW 34TH STOAKESDALE AVE SWHHHHHH 454(24' from EOP)EOP EOP EOP EOP EOP EOP EOP EOPR/W R/W R/W R/W R/W R/W R/W R/WEOPEOPEOPEOPEOPEOPEOP EOPEOPEOPEOPEOPEOPEOPEOPR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WC/LC/LC/LC/LC/LC/L C/LC/LC/LC/LC/LC/L SidewalkSidewalk D/W31+85MPOPNEW CIENA AND FDP TO BE PLACEDON EXISTING NORTH WALL BACKBOARDCUSTOMER WILL REMOVE OLD EQUIPMENTParcel #: 1253810260Parcel #: 1253810305Sidewalk29+24POE35SPEEDLIMITJet new 7 way futurepath with new 72ct MFthrough existing copper/fiber occupied conduit to HH 454 (1361').TO HH UN-106SEE SHEET 5 30+54Pull new 1.25" ID with new 24ct fiber through existing copper-occuiped customer CBO to MPOP (261').CONSTRUCTION TO ROD AND PROVE PATHWAY FROM HH TO MPOP.91'10'11'12'11'11'EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201761" = 40'