HomeMy WebLinkAboutP_Traffic_Control_Plan(TCP)_109103065_V1_171208Powell Ave SW3rd Pl
S
W
19
19
255
1111
1010111113
13
3rd Pl
S
W FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFRO
M
TOTOW
A
W
A
Y
A
R
E
A
PHON
E
8
8
8
-
9
9
9
9
INFRA
S
O
U
R
C
E
L
L
C
0
0
0
0
0
0
0
0
0
0
NO PAR
K
I
N
G
STOP
FLAGGER
STOP
FLAGGER ONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7A100'100'100'ONE
L
A
N
E
ROAD
AHEA
D W20-4ROAD
WOR
K
AHEA
D
W20-1W20-7A100'100'100'PATH OF INSTALLATION
Resident(s) will be informed
of temporary driveway
closure
Emergency vehicles will be
allowed to pass
construction zone.'X'
SIGNS TO BE USED AFTER
HOURS PRECEDING AREAS
(LANES) THAT HAVE PLATES
ON ROADWAY
CAUTION
STEEL PLATE
ON ROADWAY
T78-A
MOTORCYCLES
USE EXTREME
CAUTION
W21-1701
'X'X'X'PLACE W20-1 SIGNS ON ALL
ADJACENT STREETS WITHIN
FEET OF WORK AREA
ROAD
WORK
AHEAD W20-1ROADWORKAHEADW20-1100'
12
12
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Job#109103065
255 Powell Avenue Southwest, Renton, WA
August 22, 2017
Sheet 1 of 4 ina.ustemchuk@pse.com
(425) 424-6425
N
PSE PUGET
SOUND
ENERGY
PRINT ON
11X17" SHEETS ONLY
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
8. Work area will be 11' WCL of Powell Ave SW & from
462' to ____' NCL of SW 3rd Pl.
PATH OF INSTALL
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
FLAGGER
STOP
Powell Ave SW3rd Pl
S
W
19
19
255
1111
1010111113
13
3rd Pl
S
W81ST AVE SPowell Ave SWSTOP
FLAGGER
STOP
FLAGGER
STOP
FLAGGER
ONE L
A
N
E
ROAD
AHEA
D W20-4ROAD
WOR
K
AHEA
D W20-1W20-7A100'100'100'ONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7A100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'
100'
100'
PATH OF INSTALLATION FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGSTOP
FLAGGER
FRO
M
TOTOW
A
W
A
Y
A
R
E
A
PHO
N
E
8
8
8
-
9
9
9
9
INFRA
S
O
U
R
C
E
L
L
C
0
0
0
0
0
0
0
0
0
0
NO PAR
K
I
N
G
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
FROM
TOTOW
A
W
A
Y
A
R
E
A
PHON
E
8
8
8
-
9
9
9
9
INFRA
S
O
U
R
C
E
L
L
C
0
0
0
0
0
0
0
0
0
0
NO PAR
K
I
N
G
NO-PARKFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
OAKESDALE A
V
E
S
W
B
E
P
R
E
P
A
R
E
D
T
O
S
T
O
P
W3-4
R
O
A
DWO
R
K
A
H
E
A
D
W20-1
W20-7A100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'100'100''X'
SIGNS TO BE USED AFTER
HOURS PRECEDING AREAS
(LANES) THAT HAVE PLATES
ON ROADWAY
CAUTION
STEEL PLATE
ON ROADWAY
T78-A
MOTORCYCLES
USE EXTREME
CAUTION
W21-1701
'X'X'X'PLACE W20-1 SIGNS ON ALL
ADJACENT STREETS WITHIN
FEET OF WORK AREA
ROAD
WORK
AHEAD W20-1ROADWORKAHEADW20-1100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Job#109103065
255 Powell Avenue Southwest, Renton, WA
August 22, 2017
Sheet 2 of 4 ina.ustemchuk@pse.com
(425) 424-6425
N
PSE PUGET
SOUND
ENERGY
PRINT ON
11X17" SHEETS ONLY
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
8. Work area will be 11' WCL of Powell Ave SW & from
____' NCL to 71' SCL of SW 3rd Pl.
PATH OF INSTALL
28" TRAFFIC CONE
LEGEND
TRAFFIC FLOW
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
FLAGGER
STOP
Powe
l
l
A
v
e
S
W3rd Pl SW25511111010
111111111313 3rd Pl SW81ST AVE S
3rd Pl SWPowe
l
l
A
v
e
S
W
PATH OF INSTALLATIONFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARK
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PA
R
K
FROM
TOTOW
A
W
A
Y
A
R
E
A
PHON
E
8
8
8
-
9
9
9
9
INFRA
S
O
U
R
C
E
L
L
C
0
0
0
0
0
0
0
0
0
0
NO PAR
K
I
N
G
NO-PARK
FRO
M
TOTOW
A
W
A
Y
A
R
E
A
PHON
E
8
8
8
-
9
9
9
9
INFRA
S
O
U
R
C
E
L
L
C
0
0
0
0
0
0
0
0
0
0
NO PAR
K
I
N
GSTOPFLAGG
ER
STOPFLAGGE
RSTOPFLAGG
ER
STOPFLAGG
ER
ONE L
A
N
E
ROAD
AHEA
D W20-4ROAD
WORK
AHEA
D W20-1W20-7A100'100'100'ONE LANEROADAHEADW20-
4ROADWORKAHEADW20-
1
W20-
7
A 100'100'100'ONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7A100'
100'
100'BEPREPAREDTOSTOPW3-4 ROADWORKAHEADW20-1 W20-7A 100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'100'100''X'SIGNS TO BE USED AFTERHOURS PRECEDING AREAS(LANES) THAT HAVE PLATESON ROADWAYCAUTIONSTEEL PLATEON ROADWAYT78-AMOTORCYCLESUSE EXTREMECAUTIONW21-1701'X'X'X'PLACE W20-1 SIGNS ON ALLADJACENT STREETS WITHIN FEET OF WORK AREAROADWORKAHEADW20-1 ROADWORKAHEADW20-1100'OAKESDA
L
E
A
V
E
S
W
Job#109103065255 Powell Avenue Southwest, Renton, WAAugust 22, 2017Sheet 3 of 4 ina.ustemchuk@pse.com(425)424-6425CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040NPSEPUGETSOUNDENERGYPRINT ON11X17" SHEETS ONLYNotes:1. All signs and spacing to conform to the MUTCDand City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.4. Sign size can be a minimum of 48" x 48" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.m.8. Work area will be 6' SCL of SW 3rd St & from 28'WCL to ____' ECL of Powell Ave SW.PATH OF INSTALL28" TRAFFIC CONELEGENDTRAFFIC FLOWWORK VEHICLESIGN LOCATIONWARNING FLAGFLAGGERSTOP
Powell Ave SW
13131212111110101111
1111 13133rd Pl SWTHO
M
A
S
A
V
E
S
W3rd Pl SWPowell Ave SW STOPFLAGGER
STOPFLAGGE
R
ONE L
A
N
E
ROAD
AHEA
D W20-4ROAD
WORK
AHEA
D W20-1W20-7A100'100'100'ONE LANEROADAHEADW20-4ROADWORKAHEADW20-1W20-7A100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1 W20-7A 100'100'100'BEPREPAREDTOSTOPW3-4ROADWORKAHEADW20-1W20-7A100'100'100'FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGFROM
TOTOW
A
W
A
Y
A
R
E
A
PHON
E
8
8
8
-
9
9
9
9
INFRA
S
O
U
R
C
E
L
L
C
0
0
0
0
0
0
0
0
0
0
NO PAR
K
I
N
G
PATH OF INSTALLATIONResident(s) will be informedof temporary drivewayclosureEmergency vehicles will beallowed to passconstruction zone.'X'SIGNS TO BE USED AFTERHOURS PRECEDING AREAS(LANES) THAT HAVE PLATESON ROADWAYCAUTIONSTEEL PLATEON ROADWAYT78-AMOTORCYCLESUSE EXTREMECAUTIONW21-1701'X'X'X'PLACE W20-1 SIGNS ON ALLADJACENT STREETS WITHIN FEET OF WORK AREAROADWORKAHEADW20-1 ROADWORKAHEADW20-1100'Job#109103065255 Powell Avenue Southwest, Renton, WAAugust 22, 2017Sheet 4 of 4 ina.ustemchuk@pse.com(425)424-6425CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040NPSEPUGETSOUNDENERGYPRINT ON11X17" SHEETS ONLYNotes:1. All signs and spacing to conform to the MUTCDand City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.4. Sign size can be a minimum of 48" x 48" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.m.8. Work area will be 6' SCL of SW 3rd St & from ____'ECL of Powell Ave SW to 299' WCL of Thomas AveSW.PATH OF INSTALL28" TRAFFIC CONELEGENDTRAFFIC FLOWWORK VEHICLESIGN LOCATIONWARNING FLAGFLAGGERSTOP