Loading...
HomeMy WebLinkAboutP_Plan Drawings_170612_V1FLAGGER TO ASSIST TRAFFIC ENTERING AND EXITING DRIVEWAY rn N 1 1 I I 1 1 1 1 I 1 1 I 1 I 1 I I / I1 I I I / I I / i I / I / I I 1 / I / I I / / c � / c i / S 177th St job #107054302 PUGET SOUND ENERGY Job#106324722 400 S 43rd St Renton, WA June 1st, 2017 Sheet 1 of 1 mitchell.peterson@pse.com 425-398-6071 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. 4. Sign size can be a minimum of 48" x 48" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m. 8. Work area will be 12'W of Talbot Rd S & 232'N of C/L of S 177th St. LEGEND ® 28" TRAFFIC CONE ® BORE PIT TRAFFIC FLOW FLAGGER WORK VEHICLE SIGN LOCATION WARNING FLAG CHANNELIZATION DEVICE SPACING MPH TAPER TANGENT 55/70 40 80 35/45 30 60 25/30 20 40 rn N 1 1 I I 1 1 1 1 I 1 1 I 1 I 1 I I / I1 I I I / I I / i I / I / I I 1 / I / I I / / c � / c i / S 177th St job #107054302 PUGET SOUND ENERGY Job#106324722 400 S 43rd St Renton, WA June 1st, 2017 Sheet 1 of 1 mitchell.peterson@pse.com 425-398-6071 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. 4. Sign size can be a minimum of 48" x 48" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m. 8. Work area will be 12'W of Talbot Rd S & 232'N of C/L of S 177th St. LEGEND ® 28" TRAFFIC CONE ® BORE PIT TRAFFIC FLOW FLAGGER WORK VEHICLE SIGN LOCATION WARNING FLAG PROPOSED SERVICE 2' MPE f I A I I 1I 1 PROPOSED PIPE 2" MPE IP MAIN\ T / PE I ELBOW 2"X90° MPE INSERTED IN CUSTOMER PROVIDED 19 fi o I u 4"YELLOW CONDUIT oa 232'N CIL & 328W CIL 232W CIL, ON OIL 328'N IN CIL& WCA. I L END OF CONDUIT ,W _ I 1 (-7 I KI t i� D END OF CONDUIT END OF MAIN CAP 2' MPE 128'N C1L & 458W C2 IN CIL &_W CIL I - I I POLYVALUE 2' MPE (OPEN J i PROPOSED EASEMENT �TM VALVE BOX &SUPPORT t5 St L I 232'NCA&21'WCIL _T 'NCA. &_'WCA. 1 11 I I U 'tJI I r • II PROPOSED PIPE 2' MPE IP MAIN INSERTED IN CUSTOMER PROVIDED ' 4"YELLOW CONDUIT J 32WWCIL, WCIL I IF 1 1 CP TEST LEAD BOX COMPLETE (BRING VNRE UP IN 80X) 'N CIL & W C2 PROPOSED PIPE 2' MPE IP MAIN INSERTED IN CUSTOMER PROVIDED 4"YELLOW CONDUIT 128'N CIL, IN CIL PLOT PLAN ELBOW 2'X90° MPE 12TN CIL & 328'W CIL 'N C1L 8 W C/L 50'N, l� TIE IN TEE FIV 2'X2' MPE 232'N CIL & 18W C2 _N CIL & _'W CIL I \ S 177TH ST N o�Ey N� 2" STW IP 18'S n Backfill for Conduit -The final backfill may be soil -based select material or native soil, but free of construction debris and shall not contain rocks larger than 10"4n. diameter to prevent ilnpedence of gas system maintenance. VEHICLE S DEESS Excavated Dirt Ptle—N, 12 Min Final Grade n 24" Min Cover 24" Min Final Backfill (See Definition Above) Service Unein PVC Conduit TYPICAL GAS MAIN IN CONDUIT TRENCH DETAIL Not to Scale RESIDENTIAL Backfill for Conduit -The final backfill may ba sdFbased select material or native soil. but bee of construction debris and shall not contain rocks larger than 10" -in. dlarrleter to prevent impedence of gas system maintenance. VEHICLE ACCESS Excavated Dirt SIDE 12'-18" 24" Min — Final Grade Min �~ Min Final Backfill Cover �O (See Definition Above) Service Une in PVC Conduit TYPICAL GAS SERVICE IN CONDUITTRENCH DETAIL Not to Scale RESIDENTIAL HOLE HOG TABLE CALLOUT LOCATION DEPTH LENGTH BP1 START BP2 END BP3 START BP4 END BP5 START BP6 END BP7 START BPB END BP9 START BP10 END BP71 START BP12 END BP13 START BP14 END BP15 START BP16 END BP77 START BP78 END BP19 START BP20 END FITTER'S CHECKLIST (cHEaceozrD CQ1rFIRM coePLErnro ❑ Inspected Shat antl PE PPa Par G052450.1400aM 2450.1500 ❑ RevieeedaM �pnpt+d rti6 ell mrslrvc8an rwtes. ❑ Recorded all regdre-0iNomution on rhe as-hW perG05500.1]W. ❑ Gaamkaaa Poll bee�,6on e,ePeamncercos z5zs.t2eo and Szs2TW. p Lanu,a worxaraa raaerean era ser w. Foreman§Name (piMedJ Oan4u l INraSowce C"nsNtttion Oats ANDARD GAS CONSTRUCTION NOTES: i. FlELOLOCATE ALL UDERGROUD L1rILMES. EXCAVATOR TO CALL IOtX ' TWOWOR101D DAYS PROR TO TO CIX151RUCTOIL IN WESTERN WASHWTO11 CALL: 18064245565.OR GALL 11ATKNMIDE: 811 2 rATIFYAPPROPRATE PER&ITTIM AGEtiCY PRIOR TO AB START (ME PERIAT REOUREI,fEJnS). 3. ALLG0115TRl1CTIWI ISTO CIXFORMTO ME GAS OPERATING STNDAROS AID GAS FIELD PROCEDLRES. 4. ERO5101lND SEDINEtnCOm1aD. SHALL BE PER ME STNrOViD PRACTICE 01503200 MMrFTL1ES FOR TEMPORARY ERG6ION ND SEOtMn'C0lrTROL NO AIN AOOPONAL LOCAL Rh85DCTl(xl ftEOUREME1nS. i rDnFYPROPFRrY OLW>ERS ADI n-70PROPO.SEDCONSTRl1CTIXl ACTIVITIES A WAIAW OF TYNWORKaG DAYB PRIOR TOBEGItabtD CIXr51RI1CilIXl. t15E ISiTO CSTFrIBU1E FLYERS IF JQB IS LMGE OTIERIMSE RAID PERGAS OPERATIDSTPltl]ARD 2550.1600. ALLONADEWATE TR1E FORCISTOM1ER DECISIONND RE6PWiSE. 6. NlYCHAtDEW ROUTE, PIPE S¢ PE, TNN RIErHODOR ADDIMAL M1WU FOOTAGE MUST BE APPROVED BY TIE P.PPROPFBATE PSE PIGRIEER OR PSE REPRESEWATiVE. ]. CJM11PlETE'flPE MOF REPORI'Or ALL METNUC PSE FAGUTIES. CHECK BOX "I REPORT FOR WIRE BOX REST LEAD) IUSTALLTTKx1 B. flPEUIlE MARKERS AID VMRMtD SIGHS SHALL BE RISTALLED AD RECORDED BY THE CIXURACTOR PER PSE GAS oPeRAnrD srurDVD552sm. 9. INBTALL M1WN VALVES pUTOFTRAFFIC\14EFE P0561a1E. VALVE MFOR ARKERS SHALL BE nIFTAllEOAHD RECORDED BY TECIXnRACTOrt PERLE, AID N1VGBTAID4RD 25252EWMFSIOAF WAY IFTIERE 7HE VNIS tDTREAULY ACGESSIBIE, NA FOR ALL VKVES VALEr2E PERSISTFJn5tXg5FALLM1AYOBSCURETHE VALVE BDX. f0. TOPftEYEIn'AC]MITAL OVERPRESSLRE OF ADXxtAM SYSTEMS, W TVA AWNS SHALL. BE M14ECTED EXCEPT AS SF4DWT! IX! THS DESIGN ULESS APPROVED BY APPROPRIATE ME ENGINEER OR PSE REPRESEWATVE, 11. SYSTEIA I.UOP OEIDTED BY: YSTEM IADP=45 PSD 12. GAWENAAIOMTOR USE OFALL STOPPERS TO EI4SUFd: ADEQUATE FEED. 13. RESTORE ALLDPoVEWAYS SU OTTO OPEN CUr TO OPoGIIAL OR BETTER COIOn"ON. 14. PU2GE KNInS AID PRESSURE TAPS TO BE Ir1STALLED PER PSE GAS OP Tlrn STNDARDS 55.3300, AND 5x25.1200. 15. MAtSNASERVICES SHALL BE TESTED NO PURGED PER PSE GAS OPERAND STNAARDS 2553300 ND2525.3400. to IF I.fETPLLIC PIPE IS ONOLVED, COORDItLATE ItISTALLAMI V.1TH CP TECH 1]. IDTEALLACTWLFOOTAGE, LOCATIXINDMATEPLILCHNDESONTHE A6-BULTIN RE4( 1DF1DTE8 FOOTAGE BETWEEN FITTItDS. 18. E%CE55 RONVNVE TO BE INSTALLED ONNL NEW BESTCEtmPLSERVICE5 PER 60825002200. (RECOREX1 INFCHWAnIXI IXr D-4 CARD) Wcinity M1Tap Owner/Developer Contact Info — VNLEY MEDICAL CENTER 144105E PETROVITBKV RD BUTTE 104 RENTON, WA 98058 ATRl: JEFF BNVDER 20x.305.5750 office Name: ALFREDJACKBON Cea Pirone: 253.396.6956 CgLL 811 AT LEAST 2 BUSINESS DAYS BEFORE YOU DIG E -Mai: alaetl.jadwnQpx.mm THSScrcH r:orro 6ER5um wriFat6w,cTtocanwr of 6xrsnrrc FAdGnFs