Loading...
HomeMy WebLinkAboutMFP18002335DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP18002335 IVR Number: 18002335 Permit Informaon Permit Name:Century Link Permits Address/Locaon :05/02/2018Application Date:7227900095Parcel Number:2833 NE SUNSET BLVD Permit Type:07/30/2018Issue Date:Franchise Permit Work Class:07/30/2019Expiration Date:Minor Utility Job Number:N.351569Franchise Type:Telephone 11/19/2018Finalize Date: Description:REVISION: Access additional pole at end of path (Pole 9), place aerial fiber from pole 8 to pole 9, place 2 4'X4' bore pits, remove/replace 10'X10' sidewalk panel, bore 63' across kirkland ave, trench 7', access Ped and replace with 3048HH, place riser on pole 9, place new 233LA HH. Restoration per City of Renton standards. Conditions of Approval: 1. Any existing height violations would need to be resolved at the time of construction. New aerial fiber must have a minimum vertical clearance of 15' 6". 2. Any abandoned or unused cable would need to be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Century Link’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Century Link shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City, from the first event triggering the requirement to underground the aerial lines. Contacts Name Address PhoneTypeBilling C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP18002335 (Date)(Signature) Page 2 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov REVISION - FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Only Current Issued Permits Qualify for a Revision. For any work related to an expired or finaled permit, a new Franchise Permit Application shall be required. Submit an electronic copy of the plans with the Revision Franchise Permit Application to franchisepermits@rentonwa.gov. Permit # Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Approved Description of Work: Proposed Description of Work: Reason for change of work: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Amy Silbaugh MFP18002335 Qwest Corp d/b/a CenturyLink N.351569 Amy Silbaugh 253-372-5311 amy.silbaugh@centurylink.com 2833 NE Sunset Blvd Access to MH509, HH23021, and 8 poles. No disturbance of surface Access additional pole at end of path (pole 9), place aerial fiber from pole 8 to pole 9, place two 4'x4' bore pits, remove/replace 10'x10' sidewalk panel, bore approx 63' across Kirkland Ave, trench approx. 7', access Ped and replace with 3048HH, place riser on Pole 9, place new 233LA HH. Disturbance of hard and soft surface to be restored to city standard Original path found not viable once in field. New path required to bring service to customer 09/04/2018 4 Scott Warlick 9/11/2018 Justin Johnson 9-24-2018 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: N.351569 MFP18002335 North Sky Communications 206-962-5116 Amy Silbaugh 253-372-5311 23315 66th Ave S Kent, WA 98032 amy.silbaugh@centurylink.com 253-372-5176 2833 NE Sunset Blvd Reset FormPrint Form Amy Silbaugh Amy Silbaugh 09/04/18 Justin Johnson 9-24-2018 8:00 am to 3:00 pm Monday through Friday SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY TAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.351569 C.46 PERMIT # KIRKLAND AVE NE @ NE 11TH ST SET UP BP 1 & BP 2 BORE SHOULDER WORK UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:08/31/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.351569 C.46 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTH TAPER ('L') LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.351569 C.46 Designed for CenturyLink by Sharon Martos Approved 08/31/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Legend Not to scale Scale Marker Work Truck Work Area Cone SpotterNot to scaleNOT TO SCALE KIRKLAND AVE NE Comments: SET UP BORE PITS, EAST & WEST SIDES OF KIRKLAND AVE NE, SOUTH OF NE SUNSET BLVD NE. BORE FROM BP1 - BP2. SHOULDER WORK. PARKING RESTRICTED. SIDEWALK CLOSED. CURB WILL BE RAMPED PER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS. SPEED LIMIT25 ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5N E 1 1 T HPLDWYNE SUNSET BLVD34' N BP 2 BP 1 WORK AREA 8 X 45 DETOURM4-9bDETOURM4-9bNO FROM TO TOW AWAY AREA PHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 2833 NE SUNSET BLVD www.invarion.com MFP18002335 Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY TAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.351569 C.46 PERMIT # KIRKLAND AVE NE @ NE 11TH ST P8 - P9 AERIAL MOVING OPERATION UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:08/31/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.351569 C.46 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTH TAPER ('L') LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.351569 C.46 Designed for CenturyLink by Sharon Martos Approved 08/31/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Legend Not to scale Scale Marker Work Area Work Truck flagger symbol Not to scaleNOT TO SCALE KIRKLAND AVE NE Comments: SE CORNER KIRKLAND AVE NE & NE 11TH ST. MOVING OPERATION WITH FLAGGERS. WORK TRUCKS WILL TRAVEL WITH TRAFFIC. PARKING RESTRICTED. FLAGGERS WILL HOLD ALL TRAFFIC FOR CROSSINGS. SIDEWALK ACCESSIBLE. FLAGGERS WILL ASSIST PEDESTRIANS. SPEED LIMIT25 ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1N E 1 1 T HPLDWYNE SUNSET BLVD34'BE PREPAREDTO STOPW20-7bBE PREPA R E D TO STO P W20-7bBE PREPAREDTO STOPW20-7bBE PREPA R E D TO ST O P W20-7 bBE PREPAREDTO STOPW20-7bW20-7aW20-7 aW20-7aSPEED LIMIT 35 350 ft 350 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft X X P8 P9 N 2833 NE SUNSET BLVD www.invarion.com MFP18002335 Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY TAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.351569 C.46 PERMIT # KIRKLAND AVE NE @ NE 11TH ST PED REPLACEMENT - NEW HH SHOULDER WORK UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:08/31/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.351569 C.46 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTH TAPER ('L') LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.351569 C.46 Designed for CenturyLink by Sharon Martos Approved 08/31/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Legend Not to scale Scale Marker Work Truck Work Area Cone SpotterNot to scaleNOT TO SCALE N KIRKLAND AVE NE Comments: ACCESS EXISTING PED. EAST SIDE KIRKLAND AVE NE, SOUTH OF NE SUNSET BLVD. SHOULDER WORK. PARKING RESTRICTED. SIDEWALK IS ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. SPEED LIMIT25 PED WORK AREA 8 X 40 ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5100 ft N E 1 1 T HPLDWYNE SUNSET BLVD34' NO FROM TO TOW AWAY AREA PHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING 2833 NE SUNSET BLVD www.invarion.com MFP18002335 Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 35 / 45 30' 60' 25 / 30 20' 40' ONE LANE TWO WAY TAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.351569 C.46 PERMIT # KIRKLAND AVE NE @ NE 11TH ST TRENCH - RISER PLACEMENT - P9 SHOULDER WORK UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:08/31/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.351569 C.46 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTH TAPER ('L') LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.351569 C.46 Designed for CenturyLink by Sharon Martos Approved 08/31/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Legend Not to scale Scale Marker Work Truck Work Area Cone SpotterNot to scaleNOT TO SCALE KIRKLAND AVE NE Comments: TRENCH FROM NEW HH - P9. PLACE RISER. EAST SIDE KIRKLAND AVE NE, SOUTH OF NE SUNSET BLVD. SHOULDER WORK. PARKING RESTRICTED. SIDEWALK IS ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. SPEED LIMIT25 ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1SHOULDERWORKW21-5100 ft N E 1 1 T HPLDWYNE SUNSET BLVD34' N X P9 WORK AREA 8 X 45 NEW HH NO FROM TO TOW AWAY AREA PHONE 684-5444YOUR COMPANY NAME 555-5555 PARKING R7-T39 2833 NE SUNSET BLVD www.invarion.com MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 01 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- NARRATIVE / SPECIAL REMARKS HELD ORDER INFORMATION ASSOCIATES PROJECTS MISC. INFORMATION Site Survey For: 2833 NE SUNSET BLVD, RENTON, WA 98056, USA WORK LOCATION T.23N R.05E 9 T.23N R.05E 4 Rev 3 - Per Pole Attachment Info Rev Date - 08/30/2018 Reviewed By - Nadim Serhal MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 02 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- MARGIN LABELS MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 03 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- MARGIN LABELS POF: MH VIEW SCALE: 1:20 MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 04 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- MARGIN LABELS HH/POLE VIEW SCALE: 1:10 MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 05 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- MARGIN LABELS POLE VIEW SCALE: 1:20 MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 06 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- MARGIN LABELS POLE VIEW SCALE: 1:20 MFP18002335 CONFIDENTIAL - Disclose and Distribute Soley to CTL Employees Having a Need to Know SHEET NUMBER: SHEET 07 OF 07 Name: Phone Number: Name: Phone Number: Name: Phone Number: Engineering Contact Contact Engineer Construction Coordinator Revision Number: WC CLLI: Remote Switch Key: Project Description: Project #: Community Name: Exchange Key: GOLDEN WEST DIAMOND CORP N.351569 RENTON RNTNWA01 EMILY STARKEL (206) 379-6516 JOSE ORTIZ (360) 929-5338 BILL JIRA (425) 451-5031 TOWNSHIP: RANGE: SECTION: 23N 05E 9 Revision Date: --------- --------- MARGIN LABELS BUILDING VIEW SCALE : 1:10 MFP18002335 City of Renton Dept. of Community & Economic Development Phone: 425-430-7266 / franchise@rentonwa.gov This letter is in response to an Aerial Variance request for explanation regarding CenturyLink permit request to place fiber on job N.351569 to provide fiber to CenturyLink customer order. This customer is currently being fed by an existing underground copper feed from the east side of Kirkland Ave NE and their conduit stops 65ft out of the MPOP. The most efficient and cost-effective way to upgrade the customer to fiber is to bore across Kirkland Ave NE and replace the Ped with a new HH. From there we can trench in the grass and place a riser to pole A0505526. Then we can place aerial to pole A0505527 and proceed as originally requested. This costs us approximately, $18,000. If we were to replace this with an underground, this would cost us nearly double at $30,000. The aerial path allows for less ground disturbance, concrete disturbance, restoration, and traffic impact. If this is acceptable to the City of Renton we will proceed as planned, otherwise we will not be able to provide this service to the customer as requested. Thank You, Emily Starkel CenturyLink Engineering CDFS Fiber Engineer 23315 66th Ave S Kent, WA 98032 206-379-6516 Emily.starkel@centurylink.com MFP18002335 January 22, 2019 Amy Silbaugh Qwest Corp d/b/a CenturyLink 23315 66th Avenue S Kent, WA 98032 Via Email: amy.silbaugh@centurylink.com SUBJECT: Revision Request for Undergrounding Exemption (N.351569, MFP18002335, 2833 NE Sunset Blvd) Dear Ms. Silbaugh: The City of Renton has reviewed your request to grant CenturyLink an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. CenturyLink proposes to have North Sky Communications install a new 48-count aerial fiber connection on existing Puget Sound Energy (PSE) power poles along Kirkland Avenue NE beginning approximately 100 feet south of NE 10th Street on the west side of Kirkland Avenue NE. The new fiber connection will extend north approximately 650 lineal feet to north property line of 1033 Kirkland Avenue NE, then cross to the east side of Kirkland Avenue NE to the south property line of 1058 Kirkland Avenue NE, and continue north to south property line of 3005 NE Sunset Blvd. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090(D)(1)(h) i and ii. City of Renton Municipal Code 5-19-2.B.1 and 2 states that “Except as otherwise provided herein, any telecommunications carriers who desire to construct, install, operate, maintain, or otherwise locate telecommunications facilities in, under, over or across any public way of the City, and to also provide telecommunications service to persons or areas in the City, shall first obtain a franchise granting the use of such public ways from the City pursuant to Section 5-19-3 of this Chapter.” CenturyLink does not have a franchise agreement with the City, as its predecessor-in-interest held a blanket grant of authority, dating back to territorial times, and therefore has unique status as compared to other telecommunications purveyors. Per Eric J. Schwalb, Senior Corporate Counsel for CenturyLink, RCW Section 35.99.030 states that a city or town may not require a “master permit” from service providers seeking access to public rights-of-way who have an existing statewide grant, as Century Link has. Furthermore, the Washington State Constitution, Article XII, Section 19, grants the right to construct and maintain lines of telegraph and telephone within this state. While we concur that VOIP is allowed per the RCW and Washington State Constitution, cable service is not a right granted without a franchise. CenturyLink N.351569 (Revision) Page 2 of 2 January 22, 2019 Therefore, this analysis will focus on the overhead fiber proposed to be installed for Data/VOIP, and not the provision of future cable. In evaluating this proposal, staff considered RMC 4-6-090.D. which allows for exemptions due to technological difficulties; when costs outweigh the general welfare consideration implicit in underground installation; or, if the growth pattern of the area has not been sufficiently established to determine the ultimate service routes. In this instance, the portion of the route proposed for aerial installation is an area with existing overhead facilities that are likely to remain for a period of time. DECISION: The requested exemption from underground utility installation requirements (RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with exemption criteria of RMC 4-6-090(D)(1)(h) i and ii. Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Century Link’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Century Link shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, February 5, 2019. Sincerely, Brianne Bannwarth, PE Development Engineering Manager cc: C.E. “Chip” Vincent, CED Administrator Gregg Zimmerman, PW Administrator Jennifer Henning, Planning Director Justin Johnson, Civil Engineer II Scott Warlick, Engineering Specialist II Holly Powers, Permit Technician Pat Miller, Construction Inspection Supervisor Emily Starkel, CenturyLink Engineering Emily.starkel@centurylink.com Franchise Permits