Loading...
HomeMy WebLinkAboutP_Traffic_Contol_Plans_N.452422_181128_v1Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF KENT TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:11/27/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.452422 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF KENT requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. TRAFFIC CONTROL PLAN JOB # N.452422 C.45 PERMIT # 1 : 1536NOT TO SCALE Sharon Martos Project # N.452422 C.45 Designed for CenturyLink by Sharon Martos Approved 11/27/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com N OAKESDALE AVE SW @ SW 34TH ST MH 454 RIGHT LANE CLOSURE SPEED LIMIT35 Comments: ACCESS MH 454 EAST SIDE OAKESDALE AVE SW, SOUTH OF SW 34TH ST. RIGHT LANE CLOSURE. SPOTTER WILL ASSIST PEDESTRIANS. Legend Arrowboard (Chevron) Cone 1 : 1536 Scale Marker Spotter Work Area Work TruckROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2ROADWORKAHEADW20-1OAKESDALE AVE SW SW 34TH ST350 ft 350 ft 350 ft 10' 10'10'10'12'205 ft MH 454 WORK AREA 10 X 245 www.invarion.com Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF KENT TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:11/27/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.452422 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF KENT requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. TRAFFIC CONTROL PLAN JOB # N.452422 C.45 PERMIT # 1 : 1536NOT TO SCALE Sharon Martos Project # N.452422 C.45 Designed for CenturyLink by Sharon Martos Approved 11/27/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com N OAKESDALE AVE SW @ SW 34TH ST PED - CUSTOMER TRENCH RIGHT LANE CLOSURE SPEED LIMIT35 Comments: ACCESS PED WEST SIDE OAKESDALE AVE SW, SOUTH OF SW 34TH ST. TRENCH SOUTH APPROX 32' TO CUSTOMER FENCE. RIGHT LANE CLOSURE. SIDEWALK ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. Legend Arrowboard (Chevron) Cone 1 : 1536 Scale Marker Work Area Work Truck ROADWORKAHEADW20-1OAKESDALE AVE SW 10' 10'10'10'12'RRRRRIGHT LANECLOSEDAHEADW20-5W4-2SW 34TH ST350 ft350 ft350 ft205 ft PED CUSTOMER PED - CUSTOMER WORK AREA 10 X 260 DWY www.invarion.com Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF KENT TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:11/27/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.452422 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF KENT requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. TRAFFIC CONTROL PLAN JOB # N.452422 C.45 PERMIT # 1 : 1536NOT TO SCALE Sharon Martos Project # N.452422 C.45 Designed for CenturyLink by Sharon Martos Approved 11/27/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com N OAKESDALE AVE SW @ SW 41ST ST HH UN RIGHT LANE CLOSURE SPEED LIMIT35 Comments: ACCESS HH UN WEST SIDE OAKESDALE AVE SW @ SW 41ST ST. RIGHT LANE CLOSURE. SIDEWALK ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. Legend Arrowboard (Chevron) Cone 1 : 1536 Scale Marker Spotter Work Area Work Truck RRRRRRRRROADWORKAHEADW20-1ROAD WORK AHEAD W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2205 ft HH UN WORK AREA 10 X 145 DWY DWY SW 41ST STOAKESDALE AVE SW 350 ft350 ft350 ft 10' 10'11' 10' 10' www.invarion.com Comments: SIGN SPACING MPH "X" 45+ 500' 35 350' 30 200' 25 100' 150' Seattle 200' Sea Tac UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF KENT TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:11/27/2018 Author:Sharon Martos, Traffic Control Supervisor Project:N.452422 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF KENT requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. TRAFFIC CONTROL PLAN JOB # N.452422 C.45 PERMIT # 1 : 1536NOT TO SCALE Sharon Martos Project # N.452422 C.45 Designed for CenturyLink by Sharon Martos Approved 11/27/2018 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com SW 41ST ST @ OAKESDALE AVE SW MH 387 RIGHT LANE CLOSURE SPEED LIMIT25 Legend Cone 1 : 1536 Scale Marker Spotter Work Area Work TruckROADWORKAHEADW20-1ROAD WORK AHEAD W20-1OAKESDALE AVE SWSW 41ST ST Comments: ACCESS MH 387 SOUTH SIDE OF SW 41ST ST, EAST OF OAKESDALE AVE SW. RIGHT LANE CLOSURE. SIDEWALK IS ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. N MH 387 WORK AREA 10 X 75 ROADWORKAHEADW20-1W1-4DWY10'10' 10' 10' www.invarion.com