SITE PLAN
SCALE: 1:75
300kVA 2771480v
PRIMARY DISTRIBUTION WIRE & COMMUNICATION WIRES CROSSING
TREE TRIMMING & BRUSH CLEARING OVER SR -167 TO BE TRANSFERRED TO NEW POLES
REQUIRED ON ACCESS ROAD
NOP '
26 i
I
I
8701
"MALCOM DRILLING"
SITE SPECIFIC NOTES
900kVAAR 316006
X8722 165664
MALCOLM DRILLING
AREA FOR POTELCO TRUCKS TO PARK
IN STORAGE YARD.
f;
15kVA \
120/240v 4 sssss P01 \\
P01: 316005-165686 (TREE TRIMMING REQUIRED)
-INSTALL NEW 70'H1 POLE, SET DEPTH 14' MAX., INSIDE 13.5'x42.5" STEEL CASING
-INSTALL 11• HEAVY DUTY DBL CROSS ARMS WITH 8 P&G
-INSTALL 336.4 MCM ACSR DBL DEADENDS W/ PRIMARY NEUTRAL DBL DEADEND (STD#6033.3064)
-INSTALL NEW 20" PLATE ANCHOR WEST L= 15'
-TRANSFER AND EXTEND DOWN GUYS EAST & WEST
-TRANSFER 15kVA OH TRANSFORMER CUTOUT
-INSTALL RIGID CLEVIS NORTH FOR SERVICE TRIPLEX
-INSTALL RIGID CLEVIS SOUTH FOR SECONDARY TRIPLEX
-TRANSFER & RECONNECT ALL TRIPLEX
-COMMUNICATIONS TO TRANSFER THEIR OWN WIRE
-REMOVE & RETIRE EXISTING 55' POLE
P02: 316004-165725
-INSTALL NEW 65'H1 POLE
-INSTALL 11' HEAVY DUTY DBL CROSS ARMS WITH 8 P&G
-INSTALL 336.4 MCM ACSR DBL DEADENDS (TREEWIRE TO THE EAST) W/ PRIMARY NEUTRAL DBL DEADEND
(STD#6033.3064)
-INSTALL NEW 20" PLATE ANCHOR EAST L= 12'
-TRANSFER AND EXTEND DOWN GUYS EAST & WEST
-TRANSFER (1)-15kVA & (1)- 25kVA OH TRANSFORMER AND POLE MOUNTED CUTOUTS
-INSTALL RIGID CLEVIS -WEST
-TRANSFER 2" SECONDARY RISER & 1/0 SECONDARY TRIPLEX
-TRANSFER & RECONNECT ALL TRIPLEX
-TRANSFER STREETLIGHT
-COMMUNICATIONS TO TRANSFER THEIR OWN WIRE
-REMOVE & RETIRE EXISTING 65' POLE ( PREVIOUSLY TOPPED AS A 55' POLE)
FOREMAN NOTES
*ROLLING SLOW DOWNS ARE REQUIRED BY WSDOT FOR TRANSFERRING OF OVERHEAD WIRES*
P01 & P02 BEING REPLACE TO GAIN 10' MORE
P01: 316005-165686
-POLE IS LOCATED ON WEST SIDE OF SR -167, ON NORTH SIDE OF MALCOLM DRILLING PROPERTY FENCE.
-NO TRUCK ACCESS OUTSIDE OF FENCE- POTELCO TRUCKS ARE ALLOWED TO PARK ON MALCOLM DRILLING
PROPERTY TO REPLACE POLE, AREA IS MARKED ON SITE PLAN.
-1 DAY PRIOR TO CASING INSTALLATION, CREW TO BE ON SITE TO DE -ENERGIZE THE PRIMARY WIRES & TO
DISCONNECT AND MOVE THE TRIPLEX OUT OF WAY.
-CREW TO BE ON SITE DURING CASING INSTALLATION FOR POLE SAFETY WATCH.
P02: 316004-165725
-POLE IS LOCATED ON EAST SIDE OF SR -167, ACCESS FROM TALBOT RD S ONTO 192ND ST, WHICH IS A
PRIVATE ROAD.
PSE SCOPE
W
ICY
J �Z
O O
m �
ti O
OCO
N2
Co�
J
co�
9 316004 1x25kVA 120/240v
165725 1x15kVA 120/240v
S 192ND ST
0*101111
3b
AS OF 2/4/16 COMCAST AND THE ZAYO GROUPS CABLES WERE AT APPROX. 19' OVER ST 167. ON SATURDAY 2/5/16 COMCAST
ATTACHED A TEMPORARY MULE -TAPE TO THE COMMUNICATION CABLES, FROM A WSDOT METER POLE, TO RAISE THEM UP TO 21
FEET. PSE'S STANDARD 0700.3001 PG 2/3 REQUIRES COMMUNICATIONS CABLES TO BE AT 24FT OVER STATE HIGHWAYS. COMCAST
CABLE NEEDS TO BE RAISE UP 5 FEET AND ZAYO'S CABLE NEEDS TO BE RAISED UP 6 FEET,
NOTIFICATION CREATED FOR POTELCO TO REPLACE THE POLE ON THE WEST SIDE WITH A 15 FOOT TALLER POLE, TO GAIN 10 MORE
FEET IN THE AIR, SET AN EXTRA 5 FEET DEEP DUE TO WET CONDITIONS, AND TO REPLACE THE POLE ON THE EAST SIDE WITH A 10 FOOT
TALLER POLE TO GAIN 10 MORE FEET IN THE AIR.
OUTAGES
P01: 316005-165686
-BILLBOARDS (2)- 19200 SR 167, KENT 98031 - 206-682-3833
P02: 316004-165725
- DOT METERS (2) 192ND ST & SR167 (NOT LISTED IN SYSTEM)
POLE RETIREMENT TABLE
TEMP TRANSFERS
S/L TRANSFERS
SITE
#
POLE DATA
POLE
TEL
TV
FIBER
TRAN
RMVD
ID #
GRID#
HEIGHT
CLASS
YEAR
TOPPED
RMVD
P01
316005-165686
55
1
1981
PROJECT MGR SIERRA VEGA
253-327-3162
5/2/16
1
ENGR - POWER SIERRA VEGA
P02
316004-165725
65
1
1981
IDESCRIPTION
ENGR - GAS N/A
N/A
N/A
COUNTY
Emer Sect
Gas Wk Ctr
POLE TABLE (NEW)
Site
Pole Data
#
Grid #
Height
Class
Year
Remarks / Location Ref.
P01
316005-165686
70
H1
2016
PSE Equip #
P02
316004-165725
65
H1
2016
PSE Equip #
Q : 311 X1531 - —I 1ooT
30 ,, VALLY X1072 C
;3.•.,-i'jTOp�T MED CTR 100T \
31 J., o s �"� :' ...... 3 ti'�Q'V/,•�s 1OOT 469 X66ID 23 tcCARR
02229 17 ti•
X80' ' 4�p•T • 'I . .' . J. S -rs� b :.30
'30 .X4261 100T
•0733 •s .ST S •• . s ' �� U468 �_
X1311 3�': "3� SK83 : 1OOT /.
356 02211 '•�'�'''::30X11075 •';� NO-' S
25T 0 03 00
30.- • 4990 lr
ORI O ' NOP
. X82. ••Q30 N0(00115 0799 22 100T. ¢
• 30 s X3285 c
-7 ........ OOT
30 S 03544 X7229 .......3..... 1• c,.
' c
. ;..... ST : 100T . .... T .... 3 ...�'� .. ; 4 ..... T.....
• OTC
30 ........
3� ; Q :' ; �' 815 A' T7554340T
.............
. 3 0. A
X4450 - ....... 30 30 .65 A X91.45•
100T) ,�
. . ....:. : .
:3� / • ; 03219 B"' C 8 4oT
X D-:: 40T
40T
"" ' 0987 P • S 187 ST a ,�• •34 900KVAR
�tl NO / .�Et.•�S'�31•�F.... 307 ,100 26T62 I
35b s 02024 �i ao .CCr' 3' :33 3 c.•• B..A'•.� ••........cX7446 ie7 sT�
�° •'40T I
...........
018. .3�. �x 3 3�.' ..1OOT OT•• •: C
• 4 18B ' ST
30. :30 U20261 ...
.r 1 s• U827 6T':3D c•' ...
f: • ' X431 S c U986 ��""' i
....ST S • 01894 4QT4 ..Y�d' 'ST ' c:. @2061
14
' T 23 2211
. ' 25261z : 100T
40T •�: -1
NOP ; 5.3 PL 5T I
23 3� X11089 X87 Z TW X11094 X801 OOT • •�• •• C, 1
U1890•S TW_ T 900K AR / FL
U520 S X7116 X880 / X28 IW
25T TAP
•
' ' COT X802 40T ;11•., A ...
:X2039 •3 AI 40T'q
3i ; U I ear :B ► X10460
' S 150E:15T 4 C 1
.... S ...... 3. 40T C
� I I:. ; •�- r' 1� A I
M UIP82 .S 02046 En 1
150E
!D••30� S U2045
X8419
25T
•10
96 ST " X2038 900KVAR '' A 25T X3 1
:..... 40T...So..�........ 30657
JOB SITES
16 4oT X7403 ..
,...
3 0 • 7-i
X1256 X7402 ....... 15T
65T ;
15T X3135 0944
X1219 S X356:; 30; \/ B, !!te�e 97 pV S�
$/,9
91001'
100T X3133 X 1 34 S o Ar A S� s �8 �, 900KVAR C'
...... .. u S �' I 100T -
Q' s 1100T /100T X1505 100�� i00454OTrrn
X4423 '
30 •..... A
KVAR900 • U2043 ��3w S Qf `7� 200 ST X3295�3+d : 40T X6373 '30y 3b'RX11193F253� 40TX2034i;30� 'T :3� � :X330559 X2288`, • ' r' 100T O 1202 S__T.__((��25� C 65T 25T 'S 202 t.: ST C� *'-74�,v��C •3� Z _ ....:� I........:30 87 X5129 i�0 j X394}"Ar S 203 ST
3� 7� __` 0
V : �� �: 345 `moi 30 p X3973..:004 _
IVA
T B .... '• A . B B'• • ' 1�...0 x
C :1� ' 1ST
a
132 • .
65T W • 'e ' 3h'•. X6539 X2175Aj t>
"� �: B ,.�...., '`a C 65T TOOT �n 4
OVERHEAD CIRCUIT MAP
NOT TO SCALE
POWER GENERAL NOTES
1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation
from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the
Foremans' Copy.
2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at
least three (3) working days in advance.
3. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to
commencing work to get the underground facilities located.
4. All work is to be done in accordance with local municipal and county permit requirements as
applicable.
5. Inclement weather conditions may cause delays in construction times and dates.
POTELCO DESIGN AND
QUALITY ASSURANCE
❑ This design complies with PSE
Design/Engineering Standards.
Any/all variations have been
pre-approved/documented by the
appropriate PSE Representative.
Signature
Print Name
Date
EROSION & SEDIMENT CONTROL REQUIREMENTS
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
FOREMAN (CHECK BOX WHEN COMPLETED)
❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
❑ Field Changes RED -LINED on As -built.
❑ Material VERIFIED and CHANGES noted on Paperwork.
❑ Total PRIMARY Cable noted on As -built.
❑ Company ID#'s RECORDED in correct location on As -built.
❑ Indicate correct FUSE SIZE on As -built 8, VERIFY proper PHASE.
❑ Deviations noted on the As -built and their reason.
❑ I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
Foreman's Signature
Print Name Date
PROJECT PHASE
NOTIF# ORDER#
PWR Superior
Removal
Expense
Other
503008230 101098130
108094802
593169196
583053849
*SWITCHING REQUIRED"
Vicinity Map
CALL (800) 424-5555 1
Developer
Yes Yes x PSE 2 BUSINESS DAYS BEFORE YOU DIG
"Locates Required"
No No THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
"Outages Required"
Yes x No REAL ESTATE/EASEMENT
PERMIT
"Flagging Required"
Yes x No N/A
KENT, RENTON
& WSDOT
3
FUNCTION CONTACT
PHONE NO
DATE
2
PROJECT MGR SIERRA VEGA
253-327-3162
5/2/16
1
ENGR - POWER SIERRA VEGA
253-327-3162
5/2/16
REV# DATE
BY
IDESCRIPTION
ENGR - GAS N/A
N/A
N/A
COUNTY
Emer Sect
Gas Wk Ctr
POWER WK CTR
DRAWN BY SIERRA VEGA
253-327-3162
5/2/16
KING
N/A
N/A
QCSOKE
CHECKED BY
1/4 SEC
OP MAP
PLAT MAP
APPROVED BY
,e ., 1
FOREMAN #1 '
NW06, T22N, R05E
N/A
NIA
U -MAP NO (POWER)
OH CKT MAP
UG CKT MAP
CIRCUIT NO
FOREMAN #2
2205EO22
2205EO36
2205EO22
NOP -26
lMAPPING
JOINT FACILITIES ARRANGEMENTS
UTILITIES
N/A, N/A N/A
N/A
CONTACT
N/A, N/A N/A
NIA
PHONE#
N/A, N/A N/A
N/A
NOP -26 LOW COMMS SR -167 CROSSING
CIDENT
N/A
MAOP
N/A
SPUGET OUND
ENERGY
REPLACE 2 POLES TO RAISE WIRES OVER SR -167
POLE 1: 8701 S 192ND ST KENT, WA 98032
[GasOrder Elect Order
N/A 101098130
ALE PAGE
DESIGNED BY POTELCO
POLE 2:9199 S 192ND ST RENTON, WA 98055
1:75
1/1