Loading...
HomeMy WebLinkAboutP_Design_101098130_V1_180523S 192ND ST 8895 100T 316006 X8807 165600 (105031736) -- 315990-165594 112.SkVA 277/430v SITE PLAN SCALE: 1:75 300kVA 2771480v PRIMARY DISTRIBUTION WIRE & COMMUNICATION WIRES CROSSING TREE TRIMMING & BRUSH CLEARING OVER SR -167 TO BE TRANSFERRED TO NEW POLES REQUIRED ON ACCESS ROAD NOP ' 26 i I I 8701 "MALCOM DRILLING" SITE SPECIFIC NOTES 900kVAAR 316006 X8722 165664 MALCOLM DRILLING AREA FOR POTELCO TRUCKS TO PARK IN STORAGE YARD. f; 15kVA \ 120/240v 4 sssss P01 \\ P01: 316005-165686 (TREE TRIMMING REQUIRED) -INSTALL NEW 70'H1 POLE, SET DEPTH 14' MAX., INSIDE 13.5'x42.5" STEEL CASING -INSTALL 11• HEAVY DUTY DBL CROSS ARMS WITH 8 P&G -INSTALL 336.4 MCM ACSR DBL DEADENDS W/ PRIMARY NEUTRAL DBL DEADEND (STD#6033.3064) -INSTALL NEW 20" PLATE ANCHOR WEST L= 15' -TRANSFER AND EXTEND DOWN GUYS EAST & WEST -TRANSFER 15kVA OH TRANSFORMER CUTOUT -INSTALL RIGID CLEVIS NORTH FOR SERVICE TRIPLEX -INSTALL RIGID CLEVIS SOUTH FOR SECONDARY TRIPLEX -TRANSFER & RECONNECT ALL TRIPLEX -COMMUNICATIONS TO TRANSFER THEIR OWN WIRE -REMOVE & RETIRE EXISTING 55' POLE P02: 316004-165725 -INSTALL NEW 65'H1 POLE -INSTALL 11' HEAVY DUTY DBL CROSS ARMS WITH 8 P&G -INSTALL 336.4 MCM ACSR DBL DEADENDS (TREEWIRE TO THE EAST) W/ PRIMARY NEUTRAL DBL DEADEND (STD#6033.3064) -INSTALL NEW 20" PLATE ANCHOR EAST L= 12' -TRANSFER AND EXTEND DOWN GUYS EAST & WEST -TRANSFER (1)-15kVA & (1)- 25kVA OH TRANSFORMER AND POLE MOUNTED CUTOUTS -INSTALL RIGID CLEVIS -WEST -TRANSFER 2" SECONDARY RISER & 1/0 SECONDARY TRIPLEX -TRANSFER & RECONNECT ALL TRIPLEX -TRANSFER STREETLIGHT -COMMUNICATIONS TO TRANSFER THEIR OWN WIRE -REMOVE & RETIRE EXISTING 65' POLE ( PREVIOUSLY TOPPED AS A 55' POLE) FOREMAN NOTES *ROLLING SLOW DOWNS ARE REQUIRED BY WSDOT FOR TRANSFERRING OF OVERHEAD WIRES* P01 & P02 BEING REPLACE TO GAIN 10' MORE P01: 316005-165686 -POLE IS LOCATED ON WEST SIDE OF SR -167, ON NORTH SIDE OF MALCOLM DRILLING PROPERTY FENCE. -NO TRUCK ACCESS OUTSIDE OF FENCE- POTELCO TRUCKS ARE ALLOWED TO PARK ON MALCOLM DRILLING PROPERTY TO REPLACE POLE, AREA IS MARKED ON SITE PLAN. -1 DAY PRIOR TO CASING INSTALLATION, CREW TO BE ON SITE TO DE -ENERGIZE THE PRIMARY WIRES & TO DISCONNECT AND MOVE THE TRIPLEX OUT OF WAY. -CREW TO BE ON SITE DURING CASING INSTALLATION FOR POLE SAFETY WATCH. P02: 316004-165725 -POLE IS LOCATED ON EAST SIDE OF SR -167, ACCESS FROM TALBOT RD S ONTO 192ND ST, WHICH IS A PRIVATE ROAD. PSE SCOPE W ICY J �Z O O m � ti O OCO N2 Co� J co� 9 316004 1x25kVA 120/240v 165725 1x15kVA 120/240v S 192ND ST 0*101111 3b AS OF 2/4/16 COMCAST AND THE ZAYO GROUPS CABLES WERE AT APPROX. 19' OVER ST 167. ON SATURDAY 2/5/16 COMCAST ATTACHED A TEMPORARY MULE -TAPE TO THE COMMUNICATION CABLES, FROM A WSDOT METER POLE, TO RAISE THEM UP TO 21 FEET. PSE'S STANDARD 0700.3001 PG 2/3 REQUIRES COMMUNICATIONS CABLES TO BE AT 24FT OVER STATE HIGHWAYS. COMCAST CABLE NEEDS TO BE RAISE UP 5 FEET AND ZAYO'S CABLE NEEDS TO BE RAISED UP 6 FEET, NOTIFICATION CREATED FOR POTELCO TO REPLACE THE POLE ON THE WEST SIDE WITH A 15 FOOT TALLER POLE, TO GAIN 10 MORE FEET IN THE AIR, SET AN EXTRA 5 FEET DEEP DUE TO WET CONDITIONS, AND TO REPLACE THE POLE ON THE EAST SIDE WITH A 10 FOOT TALLER POLE TO GAIN 10 MORE FEET IN THE AIR. OUTAGES P01: 316005-165686 -BILLBOARDS (2)- 19200 SR 167, KENT 98031 - 206-682-3833 P02: 316004-165725 - DOT METERS (2) 192ND ST & SR167 (NOT LISTED IN SYSTEM) POLE RETIREMENT TABLE TEMP TRANSFERS S/L TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID # GRID# HEIGHT CLASS YEAR TOPPED RMVD P01 316005-165686 55 1 1981 PROJECT MGR SIERRA VEGA 253-327-3162 5/2/16 1 ENGR - POWER SIERRA VEGA P02 316004-165725 65 1 1981 IDESCRIPTION ENGR - GAS N/A N/A N/A COUNTY Emer Sect Gas Wk Ctr POLE TABLE (NEW) Site Pole Data # Grid # Height Class Year Remarks / Location Ref. P01 316005-165686 70 H1 2016 PSE Equip # P02 316004-165725 65 H1 2016 PSE Equip # Q : 311 X1531 - —I 1ooT 30 ,, VALLY X1072 C ;3.•.,-i'jTOp�T MED CTR 100T \ 31 J., o s �"� :' ...... 3 ti'�Q'V/,•�s 1OOT 469 X66ID 23 tcCARR 02229 17 ti• X80' ' 4�p•T • 'I . .' . J. S -rs� b :.30 '30 .X4261 100T •0733 •s .ST S •• . s ' �� U468 �_ X1311 3�': "3� SK83 : 1OOT /. 356 02211 '•�'�'''::30X11075 •';� NO-' S 25T 0 03 00 30.- • 4990 lr ORI O ' NOP . X82. ••Q30 N0(00115 0799 22 100T. ¢ • 30 s X3285 c -7 ........ OOT 30 S 03544 X7229 .......3..... 1• c,. ' c . ;..... ST : 100T . .... T .... 3 ...�'� .. ; 4 ..... T..... • OTC 30 ........ 3� ; Q :' ; �' 815 A' T7554340T ............. . 3 0. A X4450 - ....... 30 30 .65 A X91.45• 100T) ,� . . ....:. : . :3� / • ; 03219 B"' C 8 4oT X D-:: 40T 40T "" ' 0987 P • S 187 ST a ,�• •34 900KVAR �tl NO / .�Et.•�S'�31•�F.... 307 ,100 26T62 I 35b s 02024 �i ao .CCr' 3' :33 3 c.•• B..A'•.� ••........cX7446 ie7 sT� �° •'40T I ........... 018. .3�. �x 3 3�.' ..1OOT OT•• •: C • 4 18B ' ST 30. :30 U20261 ... .r 1 s• U827 6T':3D c•' ... f: • ' X431 S c U986 ��""' i ....ST S • 01894 4QT4 ..Y�d' 'ST ' c:. @2061 14 ' T 23 2211 . ' 25261z : 100T 40T •�: -1 NOP ; 5.3 PL 5T I 23 3� X11089 X87 Z TW X11094 X801 OOT • •�• •• C, 1 U1890•S TW_ T 900K AR / FL U520 S X7116 X880 / X28 IW 25T TAP • ' ' COT X802 40T ;11•., A ... :X2039 •3 AI 40T'q 3i ; U I ear :B ► X10460 ' S 150E:15T 4 C 1 .... S ...... 3. 40T C � I I:. ; •�- r' 1� A I M UIP82 .S 02046 En 1 150E !D••30� S U2045 X8419 25T •10 96 ST " X2038 900KVAR '' A 25T X3 1 :..... 40T...So..�........ 30657 JOB SITES 16 4oT X7403 .. ,... 3 0 • 7-i X1256 X7402 ....... 15T 65T ; 15T X3135 0944 X1219 S X356:; 30; \/ B, !!te�e 97 pV S� $/,9 91001' 100T X3133 X 1 34 S o Ar A S� s �8 �, 900KVAR C' ...... .. u S �' I 100T - Q' s 1100T /100T X1505 100�� i00454OTrrn X4423 ' 30 •..... A KVAR900 • U2043 ��3w S Qf `7� 200 ST X3295�3+d : 40T X6373 '30y 3b'RX11193F253� 40TX2034i;30� 'T :3� � :X330559 X2288`, • ' r' 100T O 1202 S__T.__((��25� C 65T 25T 'S 202 t.: ST C� *'-74�,v��C •3� Z _ ....:� I........:30 87 X5129 i�0 j X394}"Ar S 203 ST 3� 7� __` 0 V : �� �: 345 `moi 30 p X3973..:004 _ IVA T B .... '• A . B B'• • ' 1�...0 x C :1� ' 1ST a 132 • . 65T W • 'e ' 3h'•. X6539 X2175Aj t> "� �: B ,.�...., '`a C 65T TOOT �n 4 OVERHEAD CIRCUIT MAP NOT TO SCALE POWER GENERAL NOTES 1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy. 2. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. 3. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. 4. All work is to be done in accordance with local municipal and county permit requirements as applicable. 5. Inclement weather conditions may cause delays in construction times and dates. POTELCO DESIGN AND QUALITY ASSURANCE ❑ This design complies with PSE Design/Engineering Standards. Any/all variations have been pre-approved/documented by the appropriate PSE Representative. Signature Print Name Date EROSION & SEDIMENT CONTROL REQUIREMENTS EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) FOREMAN (CHECK BOX WHEN COMPLETED) ❑ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. ❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED. ❑ Field Changes RED -LINED on As -built. ❑ Material VERIFIED and CHANGES noted on Paperwork. ❑ Total PRIMARY Cable noted on As -built. ❑ Company ID#'s RECORDED in correct location on As -built. ❑ Indicate correct FUSE SIZE on As -built 8, VERIFY proper PHASE. ❑ Deviations noted on the As -built and their reason. ❑ I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Foreman's Signature Print Name Date PROJECT PHASE NOTIF# ORDER# PWR Superior Removal Expense Other 503008230 101098130 108094802 593169196 583053849 *SWITCHING REQUIRED" Vicinity Map CALL (800) 424-5555 1 Developer Yes Yes x PSE 2 BUSINESS DAYS BEFORE YOU DIG "Locates Required" No No THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES "Outages Required" Yes x No REAL ESTATE/EASEMENT PERMIT "Flagging Required" Yes x No N/A KENT, RENTON & WSDOT 3 FUNCTION CONTACT PHONE NO DATE 2 PROJECT MGR SIERRA VEGA 253-327-3162 5/2/16 1 ENGR - POWER SIERRA VEGA 253-327-3162 5/2/16 REV# DATE BY IDESCRIPTION ENGR - GAS N/A N/A N/A COUNTY Emer Sect Gas Wk Ctr POWER WK CTR DRAWN BY SIERRA VEGA 253-327-3162 5/2/16 KING N/A N/A QCSOKE CHECKED BY 1/4 SEC OP MAP PLAT MAP APPROVED BY ,e ., 1 FOREMAN #1 ' NW06, T22N, R05E N/A NIA U -MAP NO (POWER) OH CKT MAP UG CKT MAP CIRCUIT NO FOREMAN #2 2205EO22 2205EO36 2205EO22 NOP -26 lMAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES N/A, N/A N/A N/A CONTACT N/A, N/A N/A NIA PHONE# N/A, N/A N/A N/A NOP -26 LOW COMMS SR -167 CROSSING CIDENT N/A MAOP N/A SPUGET OUND ENERGY REPLACE 2 POLES TO RAISE WIRES OVER SR -167 POLE 1: 8701 S 192ND ST KENT, WA 98032 [GasOrder Elect Order N/A 101098130 ALE PAGE DESIGNED BY POTELCO POLE 2:9199 S 192ND ST RENTON, WA 98055 1:75 1/1