HomeMy WebLinkAboutP_Design_101112382_V1_180712N
Vicinity Map
101112382OVERHEAD CIRCUIT MAP (2306E076)
SCALE: 6" = 1 MILE
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
SCALE: NONE
UNIVERSAL MAP (2305E054)
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
Renton 14
POLE RELOCATION
PSE CAPITAL PROJECT
GENERAL SPECIFICATIONS
Scope of Work
PSE project limits
General
-All work is to be completed per PSE Standards & Practices. Copies of all PSE
Standards are available upon request.
-Work sites shall be kept clear of debris and all construction materials; equipment
and packing shall be removed daily.
-Return all unused and removed poles, transformers and hardware to PSE,
storeroom. All copper shall be coiled and returned the day it is removed from the
poles. Remove all unused pins and insulators.
-Return all streetlights, area lights and floodlights to Sumner yard.
Preconstruction
- Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by
permitting agency, in advance of starting work in Right-of-way involving a Permit.
- All system switching shall be approved by System Operations (425-882-4652) a
minimum of 48 hours in advance.
- Notify customers of all outages 48 hours in advance.
Work Drawings & Documents
- Field design changes shall be approved by PSE Project Manager or Engineer.
- Mark all field changes, equipment ID numbers and Underground cable information in
red on Foreman's copy of worksketch.
- Return one Foreman's copy of worksketch to Project Manager at completion of job.
- When permits are required, a copy shall be available on work site at all times.
Safety
- Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements.
- Refer to PSE standards 6275.9050 for personal protective grounding requirements.
- Refer to PSE standards 6275.9150 for vehicle grounding and barricading
requirements.
- Proper line clearances shall be taken at the beginning, and released at the end, of
each work day, or as otherwise instructed by the System Operator.
- Provide signs, barricades, and traffic control in conformance with permit regulations.
- Utilize flagging and other vehicle traffic control as necessary and in conformance with
local traffic regulations.
- Maintain traffic flow as required by permitting agency.
Erosion & Sediment Control
- Refer to PSE standards 0150.3200 for minimum requirements.
- Comply with all requirements of permitting agency.
- Installed erosion & sediment devices shall be maintained until vegetation has been
re-established or disturbed soil has been otherwise permanently stabilized.
Joint Facilities
- Coordinate with Communication Companies for transfers.
OVERHEAD CONSTRUCTION
Poles & Structures
- Poles are to be installed or relocated as staked. Unless otherwise noted, all pole
location measurements are from the center of the pole.
- All new poles set shall be the class indicated on the sketch, or better. Do not set a
lower class pole than specified.
- Install ground plate assembly on all new poles. Install Switch Ground Assembly per
standard specification 6014.1000 at new gang operated switch locations.
- Install grid numbers on all new and existing poles as shown on sketch.
- Straighten existing poles as indicated or as necessary.
- Treat all field-drilled poles with copper napthenate wood preservative.
- Remove old poles after communication companies have transferred off and return to
PSE storeroom. Fill and crown pole holes and restore area similar to adjacent
landscaping.
Conductors & Equipment
- Transfer all overhead and underground primary, secondary and service conductors
and guys to new poles set, unless otherwise indicated on this sketch.
- Transfer existing transformers to new poles unless otherwise indicated on this sketch.
- Use stirrups to connect all overhead and underground primary taps, and all
transformers. Install at all sites being worked within the scope of the project where
they are currently missing.
- Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600
amp switch jumpers. Install tree wire conductor for jumpers on all poles that are
double deadended with tree wire.
- Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
- Connect primary taps and transformers to same phase as existing unless otherwise
shown on the drawing.
- All neutral connections to be made with solid compression connectors. Connect all
pole grounds to common neutral.
- Use Load-interrupter cutouts (with arc shields) on all primary overhead and
underground taps with fused protection above 40T.
- Install Wildlife Protectors on all transformers.
UNDERGROUND CONSTRUCTION
Excavation
-Trenching outside of the Right-of-way shall be of sufficient depth to provide a
minimum of 36” of cover for primary conductors and 24” of cover for secondary
conductors.
-Road crossings and all trenches within the Right-of-way shall be of sufficient depth
to provide a minimum of 36” of cover for all conductors or as required by the
permitting Agency.
-All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand
cover.
-No rocks larger than 6” shall be included in backfill.
-Backfill in road crossings and within the Right-of-way shall be compacted to 95%
density or as required by the permitting Agency.
-Restore all excavated areas to original condition.
- If four or more six inch conduits are installed in a trench, fluidized thermal backfill
(FTB) shall be installed around the conduits to a depth of six inches above and to
the sides of the conduit, and two inches underneath, per PSE Standard 6790.0140.
Vaults & Handholes
- Refer to PSE standard 6775.0040 “Vault and Handhole Installation”
- Vaults shall be placed level and 2” above final grade in landscaped areas and flush
with final grade when placed in hard surface areas.
- A minimum 6” bed of 5/8” crushed rock shall be placed under all vaults.
- All conduit entrances shall be grouted.
Conductors & Conduit
- Refer to PSE standard 6800.6000 “PVC Conduit Installation”.
- Unless splices are called for, or otherwise noted or approved, conduit risers shall be
plumbed directly to road crossing conduits.
- Install insulating caps on all unused primary bushings.
- All “spare” conduits shall be capped at each end.
Owner / Developer Contact Info
officeATTN:
Renton 4, LLC/Mundy Jo Holdings, LLC
2800 156th Ave SE Suite 120
Bellevue, WA 98007
Michael Crowson 206-972-6711PHONE
CABLE TV
505920574 101112382
583059471
108106542
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Removal
OH Expense 593195929
Xfmr Removal
LEGEND
CONDUIT RISER
OVERHEAD TRANSFORMER
JUNCTION VAULT/JUNCTION BOX
NEW CONDUCTOR AND OR TRENCH LINE
DISCONNECT - FUSED
PULL VAULT OR SPLICE VAULT
EXISTING POLE
DOWN GUY
DISCONNECT - UNFUSED
NEW POLE
PADMOUNT TRANSFORMER
SECONDARY HANDHOLE
EXISTING CONDUCTOR TO BE REMOVED
OR ABANDONED
STREET LIGHT
TOTAL UNDERGROUND TRANSFORMER
ENERGY CUSTOMER DEMAND POINT
OR
OR
OR
OVERHEAD JUMPER CONNECTION
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:Lee Brown
425-417-8620
lee.brown@pse.com
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Lee Brown 425-417-8620 05/07/18
Joanna Yang 206-503-0706 05/07/18
N/A N/A N/A
Joanna Yang 206-503-0706 05/07/18
N/A RENTON
RENTON 14
POLE RELOCATION
6201 NE 4TH ST, RENTON WA 98059
N/A N/A
N/A 101112382
AS NOTED 1 of 2
KING N/A N/A CSPSKEIN
NW 14-23N-05E N/A N/A
2305E054 2306E076 N/A MAP-16
COMCAST
DANIEL LAROCHE
253-358-5460
CENTURYLINK/QWEST
KENNETH LUU
206-346-0144
T-MOBILE
360-440-0003
PSE PROJECT MANAGER
LEE BROWN
425-417-8620
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
mcrowson@mjhdevco.com e-mail
SITE
SITE
PLACE PEA GRAVEL
BAGS (MID 9995892)
FOR SEDIMENT TRAP
PLACE STRAW MULCH
ON DISTURBED AREAAUGERED HOLE
POLE
TYPICAL AUGERED WORK SITE - 0150.3200
TECHNIQUES FOR EROSION AND SEDIMENT CONTROL
DITCH OR SENSITIVE AREA
SITE
REMOVE
CUSTOMER OWNED
SERVICE POLE
UNMETERED BARN
CUSTOMER OWNED
SERVICE WIRE TO BE
REMOVED
CUSTOMER OWNED
SERVICE WIRE TO BE
REMOVED42'ROWNE 4TH STREET
84
FEED MAP
16
MAP
17
MAP
16
Aɸ
FOREIGN
OWNED #2ACSROH SEC TPXT-MOBILE CELL
TOWER
TO REMAIN
336.4MCM ACSR
336.4MCM ACSR
NEW
TRANSFER
U018043703
SITE PLAN 101112382SCALE: 1" = 20'
MATCHLINE SEE THIS PAGE
AA
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Lee Brown 425-417-8620 05/07/18
Joanna Yang 206-503-0706 05/07/18
N/A N/A N/A
Joanna Yang 206-503-0706 05/07/18
N/A RENTON
RENTON 14
POLE RELOCATION
6201 NE 4TH ST, RENTON WA 98059
N/A N/A
N/A 101112382
AS NOTED 2 of 3
KING N/A N/A CSPSKEIN
NW 14-23N-05E N/A N/A
2305E054 2306E076 N/A MAP-16
COMCAST-EVERETT
DANIEL LAROCHE
253-358-5460
CENTURYLINK/QWEST
KENNETH LUU
206-346-0144
T-MOBILE
360-440-0003
PSE PROJECT MANAGER
LEE BROWN
425-417-8620
MATCHLINE SEE THIS PAGE AA
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
318074-167834
37.5
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P2A 318079-167833 45 3 2018 PSE Equip #
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P04 318061-167832 40'1966
WIRE REMOVAL TABLE
Location
Wire Size & Type Quantity
Length
(per
conductor)RemarksFromTo
P02 P03 #2 ACSR
PRI/NTRL 2 105'
P03 P04 OH SEC TPX 1 180'
210 Total Feet (#2ACSR PRI/NTRL) Removed
180 Total Feet (OH SEC TPX) Removed
Installed at site:
Grid Number:
kVA Rating:
TRANSFORMER INSTALLATION (OH)
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
Foreman to redline the following information
25kVA 120/240v
6211250
P2A
318079-167833
CONSTRUCTION NOTES
P2A NEW 315965-165051
-INSTALL NEW 45'CL3 POLE & GROUNDS, AS STAKED (PD453) 6010.1000
-INSTALL NEW DEADEND FRAMING (1ɸ - #2ACSR) (DE2115) 6031.1040
-INSTALL NEW 25 KVA TRANSFORMER (TRFNXF) 6025.1000
--TAP Aɸ & FUSE AT 10T
-INSTALL NEW 2'' SECONDARY RISER (RIS2CSS) 6042.1000
-INSTALL NEW 10'' SINGLE HELIX ANCHOR SOUTH; L = 10 FT (ANDH1) 6012.1000
-INSTALL NEW 3/8'' PRIMARY DOWN GUY (GYD3SA) 6013.0100
-INSTALL NEW 3/8'' NEUTRAL DOWN GUY (GYD3SAN) 6013.0100
-INSTALL NEW GRID NUMBER
IP1
-INTERCEPT EXISTING SERVICE CABLES AND RE-ROUTE TO NEW H01
SPAN NOTES
P02 TO P2A
-TRANSFER EXISTING #2ACSR PRIMARY/NEUTRAL FROM P01
2-23
2-24
2-24
2-26
2-27
2-129
NEW
NEW 1-2''
NEW 4/0 UG TPX
101112382UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
Lee Brown 425-417-8620 05/07/18
Joanna Yang 206-503-0706 05/07/18
N/A N/A N/A
Joanna Yang 206-503-0706 05/07/18
N/A RENTON
RENTON 14
POLE RELOCATION
6201 NE 4TH ST, RENTON WA 98059
N/A N/A
N/A 101112382
AS NOTED 2 of 3
KING N/A N/A CSPSKEIN
NW 14-23N-05E N/A N/A
2305E054 2306E076 N/A MAP-16
COMCAST-EVERETT
DANIEL LAROCHE
253-358-5460
CENTURYLINK/QWEST
KENNETH LUU
206-346-0144
T-MOBILE
360-440-0003
PSE PROJECT MANAGER
LEE BROWN
425-417-8620
SIDE VIEW
15"
23-1/4"
32-3/4"
2"
Captive L-Bolt
Lock Cover, 10 lbs
24"
Approx
Approx
13"
Customer's
service
conductors
4-3/4" X 4-3/4"
KNOCKOUT IN 2 PLACES
Conductors enter from
beneath and shall be
folded back with handhole
Set handhole flush
to final grade
Captive L-Bolt
Lock Cover
SINGLE PHASE SECONDARY HANDHOLE
Not to scale
6" to 12"
Under Normal
Conditions
40" Min for Single Helix
65" Min for Triple Helix
Not To Scale
ANCHOR DETAIL - SINGLE HELIX
JOINT TRENCH DETAIL
NOTES:
1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. *
If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. *
2. Rocks greater than 10 inches diameter are not permitted in the final backfill.
3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the
side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line.
4. Utilities shall not be stacked over the gas line in the trench.
5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements.
6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies.
* Alternatives to full-width trench shading require PSE approval.
Primary & Secondary-Mainline Gas & Communications (NTS)
Primary
Dirt Pile
Final Grade
24" Min
36"
Min Cover
Over Power
48"
Max
Depth
Final Backfill
Gas
4" Sand Bedding
Property Line
intercept (depth varies).
SidewalkCurb
Location of roof drain
48" Typical
Width may vary per
Number of Utilities
and Conduits
6" or 12" Min Sand Shading
Over Gas after Compaction
12" Min
R/W or
Excavated
12" Typical
Power
Secondary
Power
TV & TEL
12" Min
12" Min
Separation
4,5
1,2
1
3
6
6" or 12" Min Sand Shading
Over Power after Compaction1
CABLE AND CONDUIT DIAGRAM
NOT TO SCALE
NOT TO SCALE
TYPICAL POLE WITH RISER DETAIL
Schedule 80 Bend
Ground Line
10' (Overall)
Schedule 80
Conduit8'
Min.
20'
DB 120
Conduit
36" Primary
24" Secondary
Note: Schedule 80 conduit shall
extend a minimum of 8' above
and 12" below ground line.
Ground Line
Common Neutral
6" Minimum above common neutral.
even with the common neutral for secondary.
12
13
10
11
3
5"
Min.
5
6 7
1
4
2
CL
Climbing
Space
Climbing
Space
Direction of Vehicular Traffic
5" Min.
Conduit
Conduit Clamp
Standoff Bracket
15" Min Length
Field Face
Quadrant
Road Face
Quadrant
SECONDARY CABLE & CONDUIT TABLE
LOCATION CABLE Assumed
Lot Corner
CONDUIT VOLTAGE
DROP
VOLTAGE
FLICKER ASBUILT INFORMATION
SIZE LENGTH
Design
(ft)
SIZE LENGTH
Design
(ft)
BENDS
Foreman - Complete
FROM TO (1/0,4/0,350)to Meter(ft)(in)90°45°22°11°(Percent)(Percent)Actual Amount Installed (Conduit & Cable)
P2A H01 4/0 60 2 30 1 1.0 1.8
SECONDARY HH/PEDESTAL TABLE
Site Pedestal
or
Handhole
Number of
Positions
Required
Remarks
H01 Handhole 2 HH16350
2-34
2-36x30 2-54Ax60