HomeMy WebLinkAboutMFP18004226DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP18004226
IVR Number: 18004226
Permit Informaon
Permit Name:Puget Sound Energy - Electric
Address/Locaon :08/01/2018Application Date:7225000180Parcel Number:335 PELLY AVE N, 1/2
Permit Type:08/13/2018Issue Date:Franchise
Permit Work Class:08/13/2019Expiration Date:Minor Utility
Job Number:101107973Franchise Type:Electric
Inspector:Althea Bradshaw 206-316-7663
Description:Trench and install 3" conduit from P01 to new HH located at southeastern corner of property '335'. Trench and install
2" conduits to meter base 2 M01 and M02, remove existing OH services. Restoration per City of Renton standards.
REVISION: Pavement cuts made. Restoration per City of Renton standards.
Contacts
Name Address PhoneTypeBilling
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183Applicant
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
ANISH KUMAR
PUGET SOUND ENERGY - ELECTRIC
6905 S 228th St
Kent, WA 98032
B: (253) 208-2183Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 2/01/2018
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
REVISION - FRANCHISE PERMIT APPLICATION
Published: 2/01/2018
TO THE APPLICANT: Only Current Issued Permits Qualify for a Revision. For any work related to an expired
or finaled permit, a new Franchise Permit Application shall be required. Submit an electronic copy of the
plans with the Revision Franchise Permit Application to franchisepermits@rentonwa.gov.
Permit #
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Approved Description of Work:
Proposed Description of Work:
Reason for change of work:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth
under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
MFP18004226
Puget Sound Energy
101107973 253-208-2183
Anish Kumar anish.kumar@pse.com
335 Pelly Ave N, 1/2 101107973
Trench and install 3" conduit from P01 to new HH located at southeastern corner of
property '335'. Trench and install 2" conduits to meter base 2 M01 and M02, remove existing OH services.
Restoration per City of Renton standards.
9/28/18
We were not anticipating pavement cuts but a 3'x5' cut was made. Could we restore
under the same permit?
Scott Warlick 11/8/2018
Holly Powers 11/14/2018
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Puget Sound Energy - Electric
101107973
Anish Kumar
253-208-2183
anish.kumar@pse.com
335 1/2 Pelly Ave N 98057 101107973
Crew to trench and install a new 3" conduit from P01 (318094-166145) to new HH located at
Southeastern corner of property '335'. Will then trench and install 2" conduits to meter base @ M01 & M02,
remove existing OH services. No pavement cuts anticipated. Restoration per City of Renton standards.
Potelco Inc.253-208-2183
BL005109 Poteli*227PL
7/16/2018
MFP18004226
Scott Warlick 8/2/2018
Holly Powers 8/10/2018
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR
DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
Reset FormPrint Form
101107973
PSE/Potelco Inc.
Miguel Reyna 425-748-6365
6905 S 228th St, Kent, WA 98032
miguel.reyna@pse.com
335 Pelly Ave N
TBD
9/17/2018
Anish Kumar 7/16/2018
MFP18004226
8:00AM - 3:30PM
Monday - Friday
Scott Warlick
8/10/2018
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
N 4TH STPELLY AVE NP02
P01
RIGHT
KEEP
R4-7BM6-21818maintain (2) 11' lanesRIGHTSHOULDERCLOSEDW21-5aRROADWORKAHEADW20-1W1-4LX'X'X'ROAD
WORK
AHEAD W20-1W1-4RX'X'FROM TO
TOW AWAY AREA
PHONE 888-9999
INFRASOURCE LLC 000 0000000
NO PARKING
NO-PARK
PLACE SIGNS ON
BOTH SIDES OF
WORKING AREA
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE 11111111R9-9SIDEWALK
CLOSEDR9-9SIDEWALKCLOSEDSTOP
FLAGGER
SPOTTERS WILL ASSIST
PEDESTRIANS TO CROSS
A WORKING ZONE
STOP
FLAGGER
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
N
PSE PUGET
SOUND
ENERGY
JOB#101107973
335 1/2 Pelly Ave N Renton, WA
October 28th, 2017
mitchell.peterson@pse.com425-398-6071
Sheet 1 of 1
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
Puget Sound Energy
Traffic Control Supervisor:
Mitch Peterson
Card No. 010804
Card Exp. 08/30/2021
mitchell.peterson@pse.com
(425)398-6071
WORK PIT
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
MFP18004226
LO
318094-166145
37.5kVA 120/240v
335335 1/2
ROWROWROWROWROWROWROWROWROWROW ROW ROW
ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW
ROWROWROW
ROWROWROWROWROWROWROWROWLO
LO
LO
WORK SITE
LO
LO
NEW 3"
NEW 2"
NEW 2"ROWROWROWROWROWROWROWROWROWROWROWROWLO
LO
329 LANDSCAPE STRIPSIDEWALKE.O.P.E.O.P.335
335 1/2
58'
32'
16'
4'
6'
325
337
9.
7.
6.
5.
4.
3.
2.
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
8.
POWER GENERAL NOTES
GAS
PHONE
CABLE TV
N/A N/A
N/A N/A
N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Perm. Service
OH Expense
Removal
Temporary
Job Order
Distribution
HP Main
HP Svc/MSA
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
X
X
X
X
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)101107973N
Vicinity Map
NOT TO SCALE
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Correct QC Checklist(s) reviewed.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
M. REYNA 425-748-6365 06/18/18
S. FOX 714-893-2405 06/18/18
D.FIELDS 714-893-2405 06/18/18
EXISTING EASEMENT RENTON
GRA-17, CREW2, 335 PELLY AVE N
CONVERT OH SERVICE TO UG SERVICE
335 PELLY AVE N, RENTON, WA 98057
ASPLUNDH CONSTRUCTION CORP.
101107973
AS NOTED 1/1
KING FAC-SVC
NW 17-23N-05E
2305E066 2305E088 GRA-172305E066
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE MAP#:2305E088
11332125 101107973
SITE MAP
SCALE: 1" = 50'
CIRCUIT FEET ADDED: NONE
Owner / Developer Contact Info
officeATTN:
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:MIGUEL REYNA
425-429-1201
MIGUEL.REYNA@PSE.COM
SITE SPECIFIC NOTES
P01 TO HH1
-TRENCH & INSTALL 350 UG TPLX SECONDARY IN 3" DB120 CONDUIT L= ± 50'
HH1 TO M01
-TRENCH & INSTALL 1/0 UG TPLX SERVICE IN 2" DB120 CONDUIT L= ± 76'
HH1 TO M02
-TRENCH & INSTALL 1/0 UG TPLX SERVICE IN 2" DB120 CONDUIT L= ± 35'
P01 (318094-166145)
-EXISTING 40' POLE SET IN 1965 TO REMAIN
-INSTALL NEW 3" RISER ON STANDOFF BRACKET (RIS3CSS) PER STD. 6042.1000
-REMOVE EXISTING OH SERVICES TO 335 & 335 1/2 PELLY AVE N
HH1
-INSTALL NEW 13" X 24" HH W/ 4-POS FARGOS (HH14350) PER STD. 6050.2000
**EXISTING 5' EASEMENT ALONG SOUTHERN PROPERTY LINE
**REPLACE CONCRETE SIDEWALK TO JOINTS ON EACH SIDE
**NO EXISTING UTILITIES IN PROPOSED TRENCH PATH
THOMAS GUIDE
656-C1
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
N/A
SIDE VIEW
15"
23-1/4"
32-3/4"
2"
Captive L-Bolt
Lock Cover, 10 lbs
24"
Approx
Approx
13"
Customer's
service
conductors
4-3/4" X 4-3/4"
KNOCKOUT IN 2 PLACES
Conductors enter from
beneath and shall be
folded back with handhole
Set handhole flush
to final grade
Captive L-Bolt
Lock Cover
SINGLE PHASE SECONDARY HANDHOLE
Not to scale 6050.2000
CONDUIT DIAGRAM
SCALE: 1" = 50'
DETAIL DRAWING
SCALE: 1" = 20'
Electric Service Cable
Direct Buried or in PSE provided
Excavated Dirt Pile
Final Grade
24" Min
24" Min
to
36" Max
Cover
Final Backfill for
Direct-Buried
See requirements
above
3" Sand Bedding
12" Typical
(6" Min)
3" Sand
Shading
36" MINIMUM COVER
IN RIGHT OF WAY
TRENCH DETAIL
Electric Service Cable Direct Buried (NTS)
To Excavated Dirt Pile
Final Backfill for Direct Bury - The backfill layer above the sand shading shall be soil that is
free from rocks larger than 8" in diameter, construction debris, glass, sharp rocks, and frozen
clods with standard shading depth per trench figures shown below.
DB120 Grade Conduit
RISER DETAIL
SCALE: NONE PER STD. 6042.1000 MFP18004226
11/13/17
Renton City Hall
1055 S. Grady Way,
Renton, WA 98057
PSE WO# 101107973
To Whom It May Concern,
The scope of work related to the permit application for WO# 101107973 involves the
installation of a new service pole on private property and the replacement of a bad order
service wire. The existing service also trespassing. In order to correct the trespass we are
bridling service between poles P01 and P02 as seen on the sketch.
If there are any questions or concerns, please contact me.
Sincerely,
Joshua Gilmore
Regional Systems Engineer
Ph: (425) 748-6338
Email: Joshua.Gilmore@pse.com
MFP18004226