HomeMy WebLinkAboutR-401217N
T
O
d�
O
1
W
U)
z
LU
o
ry
rQ
V
J
ry
NJ_
ry
LULU
G
N
r
a
Z
J
I-L
1I1
I
3
I
I
o�
Q
>
�
�
a
LQ
ml
3
0
Y_
w
3
w
1
z
�
1
v
l
0 1
l
•
STEEL BOLLARDS
(TYP.)
1
BRICK COLUMNS
(TYP. )
GARAGE
DOORS
J I u
o Q �.._-
� I i
Lz
I 3,
� I
g = I
� I
MAG NAIL W/WASHER
STAMPED "LS 33130"
I
I
FF=39.62
•
- - - - - - - - - - - - - - - - - - -
3 0
- - - - - - - - -
I
I
I
PARCEL A
/A
0007200096
RICHARD A STORWICk
CAROL JEAN FREY
SSMH, TOP=38.82
CTR. CHNL. 8"PVC(S-N)=29.4
10 20
7231502130
RICHARD A STORWICK
CAROL JEAN FREY
q.0 �
52
W
Q
�p 61
x 39(� BUILDING
12902125
RICHARD A STORWICK
CAROL JEAN FREY
g 6A
1
W
�I
FOUND TACK IN LEAD Q
IN CONC. MON. IN CASE,
VISITED 5/27/2004
(PLAT MONUMENT)
I
SS S
I
SSMH, TOP=39.72 30'
6"PVC(W), 8-PVC(S)
CTR. CHNL.=36.2
0
TEL Hz
YD m
v I
77
c 10 I
YD�
c�
w
Ic 0 �
Ln
O I (p cn N
C.O.
0
0 z
WM -i w M
m
6�
T H
4C \ Ik �
CB, TOP=39.03
tI.E. 8"CONC(ESE)=37.1
x 2� x -59-A 39.60
X 3g x 59 Ag x 59 6gX 39.80 0.
w
x �g �, PARCEL B a- UGP
�g 38 x 3g?° 2� 5g o° 72J1502120
X P
�
'jg - 1 �j SD
5g.
9.59 39.79 X C 0 s�
�2 I3g 3g 9p 3g 88 59'65 V 3g g6 i
7231502030 401.29 1 7 I
FF=40.55
1 1
40. 1
TACK/LEAD W/WASHER LEAD/TACK W/WASHER 1 0.5 17
STAMPED "LS 33130" STAMPED "LS 33130"
FF=40.
4 4 .421
PARCEL A CB, TOP=39.16
y 8'I7231502030 CL I.E. 8"CONC(E)=36.9
� I 8 - -
I O
I �
9.5' DOOR
38.18
39.26
I
�
/ 38.05
X 38.06
X 38.16
X 38.49
3�t92 ASPHALT
x 38.92
I
!
7231502085
o
�
CB, TOP=37.24
ALEX CUGINI JR
<
Go
7 6
1�
x 3$.88 X 39.26
o
�
c�
0
30' 30'
Io I00
FF=40.50
X 38.08
/ x 39.06
o �-
c z
D
TACK/LEAD W/WASHER
38.11
\\
CA �m
STAMPED "LS 33130"
//
CB, TOP=37.49
76
38.16 /
1 8 49
3$.92
39.08
111111117117
38.18 `�
ASPHALT PARKING LOT
74
X 38.11
x ��95
x 38.18 x 38.50
138.96
0-SEE DETAIL "A"
w
\
1 x 39.11
I I
/
X �8.92
�I
I
I
X 3$.84
I
x 3166'1
I
I
X 38.08
X 38.26
X 38.51 X 38.70
X 38/89 X 39.31
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
1
PACE
An Engineering Services Company
11255 Kirkland Way, Suite 300
Kirkland, WA 98033
p. 425.827.2014 1 f. 425.827.5043
......................................................
Civil I Structural I Planning I Survey
paceengrs.com
16
7231502085
ALEX CUGINI JR
15
BUILDING
FOUND 1/2"
REBAR/NO CAP
N
0
0
FF= 40.46
G
0
SDMH, TOP=39.15
� UNABLE TO OPEN
M
D CB, SOLID LID
TOP=39.52
I.E. 8"PVC(N)=36.7
- I.E. 8"P VC(S)=36.6
CB, SOLID LID
IEE 8' PVC(N)=35.8 .
I I ' I.E. 8"PVC( )=35.188
1 I
SDMH, TOP=39.34
iII16-DIE I.E. 8"PVC(E)=35.2
I I.E. 8"PVC(S)=35.1
J I.E. 8"PVC(N)=35.1
M
� I
of
J SSMH, TOP=39.89
/ FULL OF WATER,
PIPES NOT VISIBLE
CTR. CHNL.(N-S)=35.4
I
i 16" EC.
I
T HH
6" EC
0 '0.
(
CB,
TOP=38.84
oz
6" EC.
I.E.
8"CONC(W)=37.3
co
o
SDMH, TOP=39.36
I.E.
8"CONC(E)=37.4
®
I.E.
8"PVCO=36.9
H
h
I.E.
12"CONC(S)=35.3
1
o
I.E.
12"CONC(N)=35.1
i
cC
o-
D`
I
�
c
c
I I
co
o
z
EC.
4
z
70
r,
�
o
�I c
30' 70 �c, 3
co
BUILDING
7u
co
6"DEC.
NOTES:
HORIZONTAL DATUM: CITY OF RENTON, NAD 83/91 WASHINGTON
COORDINATE SYSTEM, NORTH ZONE. BASED ON HORIZONTAL CONTROL
POINTS 205 AND 1887. POINT 205 BEING A MON IN CASE AT THE
INTERSECTION OF BURNETT AVE AND 2ND ST,; POINT 1887 BEING A
BRASS
PLUG AT THE INTERSECTION OF RIVERSIDE DRIVE AND WELLS AVE.
VERTICAL DATUM: CITY OF RENTON, NAVD 88 BASED ON CITY
VERTICAL CONTROL MARK NUMBER 1939 WITH A PUBLISHED ELEVATION
OF 11.383 METERS.
11.383 METERS x 39.37/12=37.345 FEET.
SITE AREA: 79,494 SQ. FT. or 1.825 ACRES
ALL DISTANCES SHOWN ARE GROUND DISTANCES UNLESS OTHERWISE
NOTED.
THE LOCATION AND DESCRIPTION OF ALL SURVEY MARKERS SHOWN
HEREON ARE BASED ON FIELD OBSERVATIONS TAKEN ON MAY 27,
2004 & MARCH 11, 2008, UNLESS OTHERWISE INDICATED.
WORK PERFORMED IN CONJUNCTION WITH THIS SURVEY UTILIZED THE
FOLLOWING EQUIPMENT AND PROCEDURES: (A) 2" GEODIMETER 600
SERIES ELECTRONIC TOTAL STATION, MAINTAINED TO THE
MANUFACTURER'S SPECIFICATIONS PER W.A.C. 332-130-100. (B)
FIELD TRAVERSE, EXCEEDING REQUIREMENTS SET FORTH IN W.A.C.
332-130-090.
THIS TOPOGRAPHIC SURVEY DRAWING ACCURATELY PRESENTS
SURFACE FEATURES LOCATED DURING THE COURSE OF THIS SURVEY.
UNDERGROUND UTILITIES SHOWN HEREON ARE BASED SOLELY UPON
INFORMATION PROVIDED BY OTHERS AND PACE ENGINEERS, INC. DOES
NOT ACCEPT RESPONSIBILITY OR ASSUME LIABILITY FOR THEIR
ACCURACY OR COMPLETENESS. CONTRACTOR/ENGINEERS SHALL
VERIFY EXACT SIZE AND LOCATION PRIOR TO CONSTRUCTION.
CALL FOR LOCATE: UTILITY LOCATION SERVICE: 811.
ALL MONUMENTS INDICATED AS FOUND WERE RECOVERED DURING THE
COURSE OF THIS SURVEY AT THE DATE SHOWN IN THE SURVEYOR'S
CERTIFICATE, UNLESS OTHERWISE NOTED.
PARKING:
SURFACE= 9 STANDARD 2 HANDICAPPED 1 BUS
UPPER LEVEL= 42 STANDARD 4 HANDICAPPED
LOWER LEVEL= 42 STANDARD 4 HANDICAPPED
TOTALS 93 STANDARD 10 HANDICAPPED 1 BUS
ZONING: CD = CENTER DOWNTOWN
(SEE CITY OF RENTON ZONING SECTION 4-2-120.6 ORD. NO. 4971
ATTACHMENT "F")
SETBACKS: MINIMUMS
FRONT-O' (IF BLDG. 25' HIGH OR LESS)
SIDE -N/A
REAR -NONE
HEIGHT-MAXIMUM=95'
DETAIL A
LEGEND
N WATER VALVE
-6- HYDRANT
® WATER METER
( Q MANHOLES (SS/SD)
❑ CB
-0- POWER/UTILITY POLE
E-- GUY ANCHOR
El POWER TRANSFORMER
=I POWER/TELEPHONE VAULT
13 M POWER METER
❑ TELEPHONE/TV RISER
GAS VALVE
® JUNCTION BOX
❑O GAS METER
STREET LIGHT
0-0-El LUMINAIRE
x SPOT ELEVATION
n SIGN
o MAILBOX
CCC:)0 ROCKERY
CONIFEROUS TREE
0 DECIDUOUS TREE
CASED MONUMENT
MAGNETIC NAIL W/ WASHER
OO REBAR AND CAP
CENTER LINES
PROPERTY LINES
RIGHT-OF-WAY LINES
- - LOT LINES
DITCH LINE
-► - --► FLOW LINE
w WATER LINE
_SS SANITARY SEWER LINE
SD STORM DRAIN LINE
GAS LINE
UP UNDERGROUND POWER LINES
UT UNDERGROUND TELEPHONE LINES
UTv UNDERGROUND CABLE TV LINES
UFO UNDERGROUND FIBER OPTIC LINES
P OVERHEAD POWER LINES
OHL OVERHEAD UTILITY LINES
-0-0 0-0-0- CHAIN LINK FENCE
-x-xxxx- WIRE FENCE
0-0-0- WOOD FENCE
GRAPHIC SCALE
20 0 20 40
IN FEET )
1 inch = 20 ft.
R-401201
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
� CALL 811 (2) BUSINESS DAYS z
i I BEFORE YOU DIG -I rwi
2 CIVIL CONSTRUCTION PERMIT REVIEW #2 9/18/18
1 CIVIL CONSTRUCTION PERMIT REVIEW #1
NO. REVISION BY DATE APP
SURVEYED:
BL
DESIGNED:PLH
DRAWN:
CPB
CHECKED:
vim
APPROVED:
���p�
I�I�i1l
(UNDERGROUND UTILITY lcl�
LOCATIONS ARE APPROXIMATE)
SCALE- DATE:
1988
'r - 20' HORIZORNnTAL- NAD 1983/1991 0 CITY 0 F MERRILL GARDENS AT RENTON CENTER- ADDITION 7/19/18 J
11;R]RENTON 104 BURNETT AVE S, RENTON, WA 98057 PAGE:FIELDOK:645
PAGE:
ONE INCH DATUM DRAWING NO: EXISTING CONDITIONS MAP
AT FULL SCALE Planning/Building/Public Works Dept. C21 LLI
IF NOT ONE INCH
SCALE ACCORDINGLY C
isHEEr. 21 OF: 34 C