Loading...
HomeMy WebLinkAboutMFP18005261DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP18005261 IVR Number: 18005261 Permit Informaon Permit Name:Astound Broadband/Wave Address/Locaon :09/18/2018Application Date:9188000147Parcel Number:1000 OAKESDALE AVE SW Permit Type:10/01/2018Issue Date:Franchise Permit Work Class:10/01/2019Expiration Date:Minor Utility Job Number:5763Franchise Type:Cable Description:Proof existing conduit, pull new fiber throughout, set a small NB1730 vault, and then install 1 2" conduit from the new vault to exit the ROW onto private property. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling MATTHEW BADGLEY WAVE BROADBAND B: (425) 599-4128Applicant Domonique Price Wavedivision Holdings LLC 401 Parkplace Center, Suite 500 Kirkland, WA 98033 B: (425) 576-8200Contact Astound Broadband/WaveContact Kevin Schenck Utility Technologies Inc PO Box 1355 Woodinville, WA 98072 B: (425) 205-2190 C: (206) 730-7327 Contractor Business License Number: 50205Construction Contractor: UTILITI857DS CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Astound Broadband - billing 401 PARKPLACE CENTER, Suite 500 KIRKLAND, WA 98033 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 2/1/2018 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 2/1/2018 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $367.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Astound Broadband, LLC 5763 425-988-3295 Phil Fisk pfisk@wavebroadband.com 1000 Oakesdale Ave SW - Renton 100018800 - Embry-Riddle Proof existing conduit, pull new fiber throughout, set a small NB1730 vault, and then install 1-2" conduit from the new vault to exit the ROW onto private property. 4 4 4 4 3 Utility Technologies, Inc 425-205-2190 CC UTILITI857DS BL.042821 8/31/18 RESTORATION PER CITY OF RENTON STANDARDS Scott Warlick 9/19/2018 MFP18005261 50205 Holly Powers 10/01/2018 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: 100018800 - Embry-Riddle Aeronautical University Astound Broadband, LLC Matt Badgley 425-559-4128 401 Parkplace Ctr #500, Kirkland, WA 98033 mbadgley@wavebroad.com 1000 Oakesdale Ave SW - Renton Reset FormPrint Form Matt Badgley 8/31/2018 Scott Warlick 9/19/2018 8:00AM - 3:30PM Monday - Friday MFP18005261 SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). See Attached Design SITE INDEX: SITE ADDRESS: PERMIT TECH: CONSTRUCTION MANAGER: CONTACTS: 100018800 - Embry-Riddle Aeronautical University VICINITY SCOPE OF WORK OVERVIEW GENERAL NOTES AERIAL CONSTRUCTION:UNDERGROUND CONSTRUCTION: BUILDING CONSTRUCTION:SITE CONSTRUCTION: PERMITS:EASEMENTS: N N MATERIALS: SCOPE OF WORK: Proof existing conduit, pull new fiber throughout, set a small NB1730 vault, and then install 1-2" conduit from the new vault to exit the ROW onto private property. COVER SHEET 1000 Oakesdale Ave SW - Renton Mathew Badgley Permit Tech II mbadgley@wavebroadband.com 425.559.4128 Mobile 1. COVER SHEET 2. GENERAL NOTES 3. PLAN VIEW 4. SITE VIEW 5. TCP 1 6. TCP 2 - Approximately 440ft of proof/pull - Install (1) small NB1730 vault 1 City of Renton Minor Permit 1000 Oakesdale Ave SW - Renton Phil Fisk Construc�on Manager pfisk@wavebroadband.com 425­988­3295 (m) - (1) 2" conduit - (1) small NB1730 vault MFP18005261 GENERAL NOTES MFP18005261 LEGEND: SITE ADDRESS: PERMIT TECH: CONSTRUCTION MANAGER: CONTACTS: Phil Fisk Construc�on Manager pfisk@wavebroadband.com 425­988­3295 (m) PLAN VIEW N 80.0 ft 80.0 ft 40.0 ft Plan Scale 1'' = 50' Distribution Poles COB Overlash Agreement Transmission Poles COB Fiber to City Hall New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Pole New Wave Anchor Existing Wave Vault New Wave Vault Customer Vault New Aerial Storage Survey Monument Approx Right of Way Approx Center Line Bore Pit Mathew Badgley Permit Tech II mbadgley@wavebroadband.com 425.559.4128 440.0 ft Proof conduit and pull fiber Exit ROW onto private property 1000 Oakesdale Ave SW - Renton New Wave Vault Existing Wave Vault MFP18005261 LEGEND: SITE ADDRESS: PERMIT TECH: CONSTRUCTION MANAGER: CONTACTS: Phil Fisk Construc�on Manager pfisk@wavebroadband.com 425­988­3295 (m) SITE VIEW Oaksdale Ave SW Facing North Oaksdale Ave SW Facing Easr Distribution Poles COB Overlash Agreement Transmission Poles COB Fiber to City Hall New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Pole New Wave Anchor Existing Wave Vault New Wave Vault Customer Vault New Aerial Storage Survey Monument Approx Right of Way Approx Center Line Bore Pit Mathew Badgley Permit Tech II mbadgley@wavebroadband.com 425.559.4128 1000 Oakesdale Ave SW - Renton EXIT ROW ONTO PRIVATE PROPERTY EXISTING WAVE VAULT PROOF EXISTING CONDUIT AND PULL FIBER THROUGHOUT INSTALL NEW WAVE VAULT MFP18005261 LEGEND: SITE ADDRESS: PERMIT TECH: CONSTRUCTION MANAGER: CONTACTS: TCP 1 Phil Fisk Construc�on Manager pfisk@wavebroadband.com 425­988­3295 (m) 1000 Oakesdale Ave SW - Renton PEDESTRIAN NOTES 1. When crosswalks or other pedestrians facilities are closed or relocated, temporary facilities shall be detectable and shall include accessibility features consistent with the features present in the existing pedestrian facility. 2. Controls shown are for pedestrian traffic only. 3. Use warning lights on barricades. 4. Maintain a minimum width of 5 feet for pedestrian path. 5. For signs size refer to to manual on uniform traffic control devices (MUTCD) and WSDOT sign fabrication manual M55-05. DETOUR DETOUR Parcel number: 9188000148 Address: 1150 OAKESDALE AVE SW RENTON 98057 Parcel number: 0850220000 Address: 1000 OAKESDALE AVE SW RENTON 98057 Mathew Badgley Permit Tech II mbadgley@wavebroadband.com 425.559.4128 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 PROTECTIVE VEHICLE CHANNELIZING DEVICE WORK AREA LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730LENGTH (FT) BUFFER DATA PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE TYPICAL PROTECTIVE VEHICLE TYPE WITH TMA TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (LBS) STATIONARY OPERATION (feet) 30 MIN. 100 MAX. MINIMUM WEIGHT 15,000 LBS. (MAXIMUM WEIGHT SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION) YARD DUMP TRUCK. SERVICE TRUCK. FLAT BED. ETC. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) NOTES: 1. Recommend extending channelizing device taper across shoulder. 2. Protec�ve vehicle recommended­may be a work vehicle. 3. Flagger to be available at all �me driveways are blocked 4. When used, the downstream taper device spacing should be 20' O.C. 5. Devices should not encroach into adjacent lanes. 6. Traffic safety drums recommended for all tapers on high speed roadway 7. Advance warning sings are to be placed on all approaches when an intersec�on is within the traffic control zone. See tables for sign spacing distances. 8. Work vehicles shall use beacons. 9. All work to be performed during hours dictated by the city of Bellevue. 10. All signs are 48"X48" black on fluorescent orange unless otherwise noted. 11. Traffic shall not be stopped in either direc�on for more than 10 minutes. 12. All pedestrians will be accommodated through the work zone. 13. All driveway access shall remain open during the work week. B L X X X RIGHT LANE CLOSED AHEAD ROAD WORK AHEAD ROAD WORK AHEAD 500FTEND ROAD WO R K 500FTEND ROAD W O R K Oaksdale Ave SW MFP18005261 LEGEND: SITE ADDRESS: PERMIT TECH: CONSTRUCTION MANAGER: CONTACTS: TCP 2 Phil Fisk Construc�on Manager pfisk@wavebroadband.com 425­988­3295 (m) 1000 Oakesdale Ave SW - Renton PEDESTRIAN NOTES 1. When crosswalks or other pedestrians facilities are closed or relocated, temporary facilities shall be detectable and shall include accessibility features consistent with the features present in the existing pedestrian facility. 2. Controls shown are for pedestrian traffic only. 3. Use warning lights on barricades. 4. Maintain a minimum width of 5 feet for pedestrian path. 5. For signs size refer to to manual on uniform traffic control devices (MUTCD) and WSDOT sign fabrication manual M55-05. DETOUR DETOUR Parcel number: 0850220000 Address: 1000 OAKESDALE AVE SW RENTON 98057 Parcel number: 9188000148 Address: 1150 OAKESDALE AVE SW RENTON 98057Oaksdale Ave SW B L X X X RIGHT LANE CLOSED AHEAD ROAD WORK AHEAD ROAD WORK AHEAD 500FTEND ROAD WORK 500FTEND ROAD WO R K Mathew Badgley Permit Tech II mbadgley@wavebroadband.com 425.559.4128 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 PROTECTIVE VEHICLE CHANNELIZING DEVICE WORK AREA LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730LENGTH (FT) BUFFER DATA PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE TYPICAL PROTECTIVE VEHICLE TYPE WITH TMA TYPICAL PROTECTIVE VEHICLE (WITH TMA) LOADED WEIGHT (LBS) STATIONARY OPERATION (feet) 30 MIN. 100 MAX. MINIMUM WEIGHT 15,000 LBS. (MAXIMUM WEIGHT SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION) YARD DUMP TRUCK. SERVICE TRUCK. FLAT BED. ETC. A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS (1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) NOTES: 1. Recommend extending channelizing device taper across shoulder. 2. Protec�ve vehicle recommended­may be a work vehicle. 3. Flagger to be available at all �me driveways are blocked 4. When used, the downstream taper device spacing should be 20' O.C. 5. Devices should not encroach into adjacent lanes. 6. Traffic safety drums recommended for all tapers on high speed roadway 7. Advance warning sings are to be placed on all approaches when an intersec�on is within the traffic control zone. See tables for sign spacing distances. 8. Work vehicles shall use beacons. 9. All work to be performed during hours dictated by the city of Bellevue. 10. All signs are 48"X48" black on fluorescent orange unless otherwise noted. 11. Traffic shall not be stopped in either direc�on for more than 10 minutes. 12. All pedestrians will be accommodated through the work zone. 13. All driveway access shall remain open during the work week. MFP18005261