HomeMy WebLinkAboutMFP17000131.pdfDEPARTMENT OF COMMUNITY CITY OF AND ECONOMIC DEVELOPMENT woosRenton ' Franchise Permit: MFP17000131 Permit Name: Address/Location: Permit Type: Permit Work Class Franchise Type: Description: Bil PSE -Electric 154 BLAINE AVE NE Franchise Minor Utility Electric IVR Number: 17000131 Parcel Number Job Number: lace distribution pole P01 and stub pole PO2 in Blaine Ave NE. Name X Contact Carli Bunkelman PSE/POTELCO - Billin_g _ Contractor VICKI HENSON POTELCO INC Electrical Contractor: POTELI*34404 Construction Contractor: POTELI*227PL Owner Kari Roller Citv of Rer 1723059125 101103202 Address 6905 S 228th St Kent, WA 98032 8001 212th St S Application Date Issue Date: Expiration Date: Est. Completion: 01/09/2017 01/09/2017 01/09/2018 01/15/2017 Phone 6: 3)437-6708 B: (253) 863-0484 Kent, WA 98032 Business License Number: BL.005109 1055 S Grady Way B: (425) 430-6851 C: 5)430-6931 • Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton . • This permit and plans must be posted at the job site at all times. • 1 hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements . • Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. • Call 8 11 to locate underground utilities at least two full business days prior to any excavation . • In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities . This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Signature) (Date) THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Page 1 of 2 DEPARTMENT OF COMMUNITY CITY OF AND ECONOMIC DEVELOPMENT Renton 0 Franchise Permit: MFP17000131 IVR Number: 1/uuun1 nspections - Call (425) 430-7203 or go to: www.MyBuildingPermit.com to - Do not cover until approved. schedule an inspection. - Do not occupy until final inspection is complete. - Call before work is concealed or concrete poured. - Final inspection is required. - Do not pour concrete until approved. Number Description Date Inspector j Comments 918 Traffic Control Plan Inspection 928 ENG -Job Start 914 Restoration Inspection 906 Final Walkthrough Inspection THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Page 2 of 2 (� itt- of �•� `� QLKARTM MI OF COMMUNITYAND ECONOMIC.DVELQPMtNT DC r.L%JPIVIENT 3rr% Mca DIVISION MASTER USE/FRANCHISE UTILITY PERMIT APPLICATION Phone: (425) 430-7266 Fax: (425) 430-7231 franchise@rentonwa_eov TO THE APPLICANT: Submit 3 copies of plans with application. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. For Citv Use On CITY PERMIT NO: MFP � ? Cr'D-d / 3 / Date of Application: 12/23/2016 WORK ORDER NO.: 87029 Franchise Agency: KentWA Puget Sound Ener9� Mailing Address for Permit: 6905 S 228th St, , Contact Carpi Bunkelman Name: Job Number: 101103202 Job site Address: 154 Blaine Ave NE zip: 98032 Phones 253-4'37-6708 e-mail: Carfi.Bunkefman@pse.com Project -Name: Description of work: Crew to replace distribution -pole P01 � stub pole P02 in Blaine Ave NE. Please Check ail that ❑ New Construction ®Repair/Relocate ❑ Open trench El Bore El# of feet: Estimated Job completion date: Contractor name: Potelco Inc. 0'1 /15/17 ❑ Underground ❑Overhead ❑ Gas ®' Electric ❑; Other: ❑ Sidewalk ®Street Phone: 253-437-6708 City of Renton Business License Number: BLO05109 State Contractors License Number: Poteli*227PL "I certify that I am the applicant's owner or authorized agent and do hereby agree to abide oto -the terms and conditions set forth under this permJLarrd shall comply with the City of Renton's Trench Restoration and Street Civerlay Requirements. " Signature D ate 12/23/2016 CITY INSPECTOR SHALL BE NOT1fiED 24 HOURS PRIDR TO COMMENCEMENT OF ALL l/VORK RY CALLIN!G THE INSPECTION LINE AT-425-430-72t►3 Jobs are required to be called in for job start, re -inspection and project final. I b � � ,Approved as Submitted Plan R v' w/Development Services Date ❑ On -Site Pre -Con Required El Approved with Comments or Redlines 7 [Z Traffic Control Plant Attached ❑ Camera Inspection of Utilftie-s-Required Utility Inspector Date Issue Date: Public Works Permit Supervisor Date Permit expires 6 months from issue date CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: 101 103202 CONSTRUCTION COMPANY: POteICO Inc. CONTACT NAME: Carle B -UH �GelC11011 ADDRESS: 6905 S 228th St, Kent, WA 98032 E-MAILADDRESS: CarfT,Bl�rlketrxlan a�pse.Com PROJECT LOCATION: X54 Blaine AVe NE woR�c TIN9E0 TBD WORK DATE: TBD PERMIT# PHONE#: PHONE#: CELL#: FAX#: N/E/S/W OF: APPROVED BY: 2534137-6708 APPROVAL DATE: � � � Cn ` Ze I Permit Holder agrees to all the following: • Comply with all traffic regulations. of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That pian shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and 'hold'harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney's fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder's agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City's reasonable attorney's, fees and litigation costs incurred: resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement aresubject to revision by the City Inspector>on5ite, Lif needed to .address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: CaW'li 8un'kelman DATE: I 2123/2n'I a SIGN'ATU'RE: OFFICE COPY T - CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV, SERVICE, PLAN REVIEW 8, BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS#13 NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City's PW/Transportation Division for review and/or approval at least three working days prior to work. Approved Temporary Traffic Control Plan must be at the work site during work hours. Contractor or entity must cail Rentan School District (425-204-4455) ,or any public/private agency to be affected by a temporary lane or road closure. Complete assistance and accomrrrodation shalt #�e _p°rovicled to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. Any vehicle, equipment, barricade, or portable tow -away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary Ntt Barking. Zones; ali` the following, apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. - The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City's maintenance shop (3555 NE 2"d Street). SKETCH -- AHEAD LANE CLOSED AHEAD (W 20-5L) FLOGGER AHEAD (W 20-5L) TABLE A TAPER LENGTH TRUCK WITH SPEED CONE SPACING FLASHING FT BEACON (MPH) ALONG TAPER OFFSET WIDTH (FT) 10' 12' 25 105 125 10-20 30. 150 180 10-20 T 35 205 245 10-20 IT 40 270 320 10-20 BUFFER SPACE: 425' (50MPH) 45 450 540 10-20 O 50 500 600 10-20 O O° TAPER LENGTH: SEE TABLE A NOTE: O O 6 DEVICE MINIMUM 1. DISTANCE BETWEEN SIGNS SHALL BE 100' FOR RESIDENTIAL STREETS (25 MPH), AND STo 200' FOR ARTERIAL ROADWAYS O J 2. FLASHING BEACON SHALL BE I U INSTALLED AT EACH SIGN FOR d NIGHT—TIME USE. 3, DISTANCES MAY VARY AS APPROVED 500' BY THE ENGINEER. FLACCER AHEAD 4, FLAGGERS REQUIRED TO CONTROL (W 20-5L) TRAFFIC WHENEVER THE CONTRACTOR 500' MUST INTERRUPT TRAFFIC FLOW TO ACCESS THE WORK SITE WITH LANE MATERIALS OR EQUIPMENT. CLOSED AHEAD HEAD 5. SIGN SIZE PER MUTCD. (w 20-5L) 500' LEGEND: ROAD CONSTRUCTION R CONE OR CHANNELIZING DEVICE AHEAD (SEE STD 702) (W20-1) TRAFFIC CONTROL PLAN REwsES.REED 4-28-2014 PUGET 2 LANE ROADWAY: ONE LANE CLOSED WITH APPROVED: DATE: SOUND ENERGY ALTERNATING ONE-WAY TRAFFIC AND FLAGGERS PLANNING AND ENGINEERING DEPARTMENT DRAWNGNUMBER: 2A -90C N SCALER: 1 0 a 164 UO2 TRANSFORMER TRANSFER New pole at site: P0 1 Grid Number: 317959-166495 kVA Rating: 25 — Foreman to redline the following information Company ID#: Primary phase connected to: Tested Secondary Voltage 158 317955-166466 � / 152 121 Ar"" \� �'- 317945-166475 50kVA 1201240v 115 SITE PLAN- 6-.._. .. SCALE: 1`-501 (fg) 317961-166490 120 317978-166504 I x25kVA 120/240V lxlOkVA 120/240v 317959-166495 25kVA 1201240V 317945-166492 16T UNK 151 150 146 142 SITE SPECIFIC NOTES 154 BLAINE AVE NE, RENTON P02 317961 -1 POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS SITE # POLE DATA POLE TEL TV FIBER TRAN RMVD ID NUMBER GRID # HEIGHT CLASS YEAR TOPPED RMVD P01 317959-166495 40 ENGR -GAS 1953 El El El El ❑ ❑ ❑ Todd Zumwalt 82-6405 66490 30 1977 El El El 0 El El El FOREMAN #1 P01: 317969-166495 (Avg. Span =185; < 18*) - EX. 40 " ,f 1953 POLE TO BE REPLACED -REPL W/ 40' CL 4 POLE (PD40 ) PER STD 6010-1000 I -1A x I = INST 1 * DBL PTP (ANG112) PER STD 6031.1020 - INST (2) RIGID CLEVISI (INDNRC) - TRANSFER 26kVA TRF & L.B. C/O, RETAP (0 M TRANSFER OH SEC (S) & SVCS (E, SE) - INST (2) 3/819 SPAN GUYS (GYD30W) (W) TO P02, PER STD 6013.0170 - TRANSFER STLT - TRANSFER AMR '50511' TOP POLE 1' ABOVE COMM 2429 x I COMM TO TRANSFER INST GRID # P02: 317961-166490 (EX STUB POLE) EX. 30, 1977 POLE TO BE REPLACED REPL Wi 30, CL 4 POLE (PS304) PER STD 6010-1100 14A x 1 CONNECT (2) 31891 SPAN GUYS FROM POI (E) INST 711611 PRI DOWN GUY (GYD7SA) TO EX. ANC (W) INST GRID # Scope REPLACE (2) POLES, LINE & STUB POLE Please replace b/o 40' single phase line pole set 1953 at grid number 317959-166495, U -map 2305EO65. Lat/Lon = 47.4842, -122.1894 Budget Pole replacement will fall under the planned OH Capital Budget. Estimated cost for this work is: WBS Element P 10012.06.01.01 - $8,900 CAP WBS Element P10012.06.02.01-$570 EXP Chad Hoover, 10/27/16. 1►1 SCALE. -6 "aw"o 1 MILE POLE TABLE (NEW) Site # Pole Data Grid # Height Class Year Remarks /Location Ref. P01 317959-166495 40 4 N/A PSE Equip# P02 317961-166490 30 4 PSE Equip # rA8 I =3,ARa 23 Sr ***sees 898*20661 ftft oo*% 90 0 0 - ft Ir .1101%,?4 **A 0008 1 X1 74 100 : No B 3 0: coo) JVo1'8101 'Sao o* 6 *as so: 100T 30- • AvB :18 30 aon, go 94 X• % X471 0 %lbo •0" 6%swasoor, •oy to 0 a 03 $11splo•a % SY a b *8 OOT ST40T 100T pose .. � 3 X• 65 131 G 013 1 10,•1s, 65T "mao a 1 131 M a 6-.., tX55 2 a "ek : a 65T 11 Be I OOT:: 0* A :A 65T dqd OOT CO2=5 % T 6002 a 3001 9 @0 28 00*00 0 0 goes 00 X• 30 346 a *609 JOB S1TEe!!o.% 0 so V_ -0 a, 0 ok 5T Wo 045 x769 0 0 • 65T •100T ee* V1 0 030 loans 65T a *030 % 30 '030 • 0 rPCR**N coo V 0 a �J 91 Q4 tOR�A � � � a 93 • M04249 • as a *a*0 X1 2085 30 %4 %00 U3216 10, 3 %a a ; '� 30 0 3009 % •...,r.,.......... a %A 6 4* 9 J • tee % �30 44 *0 00 o4c a *a % o C U % 0 0 a so 10 o ga 0 a 060 a A9C 1# B a ao r X11315' . �1- �`30 so a 46 799C ?• VC 4 a 40 400w� tGRA 8 T 5F 7 lose's U4641 Nee 131 ***a_ OVERHEAD CIRCUIT MAP (2)305E088 SCALE: 6" = 1 MILE FOREMAN (CHECK BOX WHEN COMPLETED) 0 PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. 0 Grid, Cable, and Switch numbers INSTALLED & VERIFIED. 0 Field Changes RED -LINED on As -built. 0 Material VERIFIED and CHANGES noted on Paperwork. 0 Total PRIMARY Cable noted on As -built. 0 Company IDWs RECORDED in correct location on As -built. 0 Indicate correct FUSE SIZE on As -built & VERIFY, proper PHASE. 0 Deviations noted on the As -built and their reason. 0 1 certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. Foreman's Signature Print Name Date PROJECT PHASE NOTIF# I ORDER# PWR Superior OH Expense UG Expense OH Expense UG Expense Removal 11270087 101103202 N/A 583055651 N/A 584.... N/A 593177372 N/A 594.... N/A 108099008 REV# DATE BY DESCRIPTION ENGR -GAS CABLE TV N/A N/A PHONE _17 Gas Wk Ctr IN/A Project Manager Contact on: Jeremy Tuntland (425) 516-3033 Cog Phone "Locates Required" (SD No "Outages Requited" Yes (ZD "Flagging Required" e No Owner/ Developer Contact Info PSE I ATTN: Chad Hoover 81-3279 office For contacts below dial 1 -888 -CALL PSE (225-5773) CALL (800) 424-5566 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES REAL REAL ESTATE/EASEMENT PERMIT N/A I City Of Rp-ntnn 3 2 FUNCTION PROJECT MGR CONTACT Jeremy Tuntland PHONE NO 425-516-3033 DATE 12/14/16 1 ENGR -POWER Carl Buher 425-457-9536 12/14/16 REV# DATE BY DESCRIPTION ENGR -GAS N/A N/A N/A COUNTY KING Emer Sect NIA Gas Wk Ctr IN/A POWER WK CTR QCSOKE DRAWN BY Todd Zumwalt 82-6405 12/14/16 CHECKED BY .lot 1/4 SEC NE17 T23N R05E OP MAP N/A PLAT MAP N/A APPROVED BY C___ 01.395.64(t m(Ni/15 FOREMAN #1 U -MAP NO (POWER) 2305E065 OH CKT MAP 2305E088 UG CKT MAP NIA ICIRCUIT NO PRE -12 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# COMCAST CENTURYLINK/QWEST 303-992-0935 PUGU SOUND ENERV T DESIGNED BY PSE PRE -12 REPLACE 1 DISTRIBUTION POLE REPLACE BAD ORDER POLES 154 BLAINE AVE NE, RENTON, WA 98056 INCIDENT MAOP NIA N/A Gas Order Elect Order NIA 101103202 SCALE PAGE 1##=50' 1/1