Loading...
HomeMy WebLinkAboutF_Lindbergh HS Parking Lot_Landscape Plans_170721.PDFEXISTING TREE TOREMAIN, TYP.LAWNLAWNLAWNLAWNREPAIR LAWN DISTURBEDBY CONSTRUCTION, TYP.TREE PROTECTIONFENCING, TYP.1L1.0END LAWN REPAIR ATEXISTING DRIVEPROPERTY LINE, TYP.PROJECT WORK LIMITSTREE TO BEREMOVED,SEE CIVILDEMO PLANSTREE TO BEREMOVED,SEE CIVILDEMO PLANSSTYRAX IN FILTERRA, TYP. TO BEPROVIDED AND INSTALLED BYFILTERRA INSTALLERS.ALEE ELM,TYP.CAREX IN FILTERRALEGENDHYDROSEEDED LAWNPLANTING NOTESGENERAL: THESE NOTES ARE HIGHLIGHTS FROM THE SPECIFICATIONS AND INTENDEDTO PROVIDE DIRECTION TO CERTAIN ASPECTS OF THE PLANTING. IF THESE NOTES AREIN CONFLICT WITH THE SPECIFICATIONS, THE SPECIFICATIONS WILL SUPERCEDE.1.SEE SPECIFICATIONS FOR PLANT MATERIAL, TOPSOIL AND PLANTING MIX TYPESAND DEPTH, MULCHING, SOIL AMENDMENTS, FERTILIZERS AND WARRANTEES.2.INSTALL 8" NEW TOPSOIL IN ALL NEW LAWN AREAS UNLESS WITHIN EXISTING TREEDRIPLINE.3.INSTALL 3' DIA. 3" DEPTH MULCH CIRCLE AROUND EXISTING TREES. DO NOTDISTURB SOIL WITHIN DRIPLINES.4.PLANTING SHALL CONFORM TO ALL CITY OF RENTON CODE REQUIREMENTS,INCLUDING PRESERVATION OF ADEQUATE INTERSECTION SIGHT DISTANCE LINES/TRIANGULAR AREAS.5.CONTRACTOR SHALL VERIFY ON-SITE CONDITIONS PRIOR TO BIDDING ANDCONSTRUCTION.6.THE CONTRACTOR AND OWNER ARE RESPONSIBLE FOR READING THE PLANS,SPECIFICATIONS AND NOTES.7.THE CONTRACTOR SHALL VERIFY ALL PLANT MATERIAL QUANTITIES PRIOR TOINSTALLATION. ANY PLANT MATERIAL QUANTITIES LISTED ARE FOR THECONVENIENCE OF THE CONTRACTOR. ACTUAL NUMBER OF SYMBOLS SHALL HAVEPRIORITY OVER QUANTITY DESIGNATED. THE CONTRACTOR SHALL BERESPONSIBLE FOR COUNTING THE TOTAL NUMBER OF PLANTS INDICATED ON THEPLANS AND ESTIMATING GROUNDCOVER QUANTITIES.8.THE CONTRACTOR SHALL FURNISH AND PAY FOR ALL CONTAINER OR FIELDGROWN TREES, SHRUBS AND GROUNDCOVERS, INCLUDING SEEDED AND SODDEDTURF, HYDROMULCHES AND FLATTED GROUNDCOVERS. THE CONTRACTOR SHALLALSO BE RESPONSIBLE AND PAY FOR: PLANTING OF ALL PLANT MATERIALS; THESPECIFIED GUARANTEE OF ALL PLANT MATERIALS; THE STAKING AND GUYING OFTREES AND THE CONTINUOUS PROTECTION OF ALL PLANT MATERIALS UPON THEIRARRIVAL AT THE SITE.9.CONTRACTOR IS RESPONSIBLE FOR REPAIRING LANDSCAPE AREAS DISTURBEDDURING CONSTRUCTION, INCLUDING THOSE NOT HIGHLIGHTED IN THESE PLANS,TO PRE-CONSTRUCTION CONDITIONS.10.SEE L2.0 SHEET FOR IRRIGATION.11.SEE L2.1 SHEET FOR DETAILS.2215 North 30th Street, Suite 300 Tacoma, WA 98403253.383.2422TEL253.383.2572FAXwww.ahbl.comWEBT A C O M A SEATTLE SPOKANE TRI-CITIESKnow what'sbelow.before you dig.CallR1REVISED PER CITY COMMENTSMGS7/7/17KGLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS LINDBERGH HIGH SCHOOLSOUTH PARKING LOT IMPROVEMENTSRENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS C17-002606PR17-000287 TED-40-3959 PLANTING PLANL1.0TREE PROTECTIONFENCINGKEY PLANNNNTSPROJECT LIMITSLINDBERGHHIGH SCHOOLELEVATIONFENCING/ROOT PROTECTION1.FENCING TO BE PROVIDED AND MAINTAINED AT CANOPY DRIP LINE.2.TREE PROTECTION FENCE SHOULD BE MAINTAINED THROUGHOUT GRADING ANDCONSTRUCTION AND SHALL NOT BE REMOVED UNTIL FINAL ACCEPTANCE.3.ALL BRUSH CLEANUP WITHIN DRIP LINE SHOULD BE COMPLETED BY HAND TOPREVENT DISTURBANCE OF NATIVE GROUND COVERS.4.NO WIRES, CABLES, OR OTHER DEVICES SHALL BE ATTACHED TO PROTECTEDTREES DURING CONSTRUCTION.5.CONTRACTOR SHALL REFER TO PLANS AND SPECIFICATIONS FOR ADDITIONALINFORMATION.TRENCHING/EXCAVATIONCRITICAL ROOT ZONE1.NO DISTURBANCE ALLOWED WITHOUT SITE-SPECIFIC INSPECTION AND APPROVALOF METHODS TO MINIMIZE ROOT DAMAGE.DRIP LINE1.LANDSCAPE ARCHITECT'S APPROVAL REQUIRED FOR USE/ACCESS WITHIN DRIPLINE.2.NO SOIL DISTURBANCE OR ACTIVITY ALLOWED WITHIN FENCED AREAS, SUCH ASMATERIAL STORAGE/STOCKPILING, PARKING, EXCAVATION, DUMPING OR WASHING.3. ANY TRENCHING SUBJECT TO FIELD INSPECTION AND APPROVAL BY LANDSCAPEARCHITECT.FEEDER ROOT ZONE1.OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING OF MATERIALS SUBJECTTO LANDSCAPE ARCHITECT'S APPROVAL.2.MINIMIZE TRENCH WIDTH WHEN USING HEAVY EQUIPMENT. SURFACE PROTECTION*MEASURES MAY BE REQUIRED.3.LIMIT ANY DISTURBANCE TO MAXIMUM 1/3 OF FEEDER ROOT ZONE.4.IF ROOTS GREATER THAN 2 INCH FOUND OUTSIDE OF FENCING, PROTECT BY HANDEXCAVATION AND, IF NECESSARY, CUT CLEANLY AND KEEP MOIST.5.USE 3 INCHES OR DEEPER WOOD CHIP MULCH OUTSIDE FENCED AREAS TOPROTECT FEEDER ROOTS.*SURFACE PROTECTION MEASURES6-8" MULCH LAYER, 3/4"PLYWOOD, OR STEEL PLATESDRIP LINE4'-0"CRITICAL ROOT ZONEDIA=1/2XDIA=XFEEDER ROOT ZONEWOOD POST 8' OCMAX SPACING.INSTALL AT A MIN.OF 2'-0" BELOWGRADE.ORANGE VINYLDIAMOND MESHCONSTRUCTIONFENCING, TYP.TREE PROTECTION3/16" = 1'-0"DIA=2XUSE 8" WIRE 'U' TOSECURE FENCEBOTTOM, TYP.1P-2017-LIN-73NOTES:·STYRAX TREES AND CAREX TO BE SIZED, SELECTED, PROVIDED AND INSTALLED BY FILTERRA INSTALLER.FILTERRA CONTACT: CHRIS HASS, CONTECH ENGINEERED SOLUTIONS, CHASS@CONTECHES.COM, 503-310-5539R-395915SE 164TH ST128TH AVE SE 132ND AVE SETREESCODEBOTANICAL NAMECOMMON NAMECONTQTY SSSTYRAX JAPONICUS `SNOW CHARM`JAPANESE SNOWBELLTBD3 UEULMUS PARVIFOLIA `EMER II``EMER II` ALLEE ELM2" CAL.2SHRUBSCODEBOTANICAL NAMECOMMON NAMECONTSPACINGQTY CO2CAREX OBNUPTASLOUGH SEDGETBD18" o.c.6PLANT SCHEDULEIN COMPLIANCE WITH CITY OF RENTON STANDARDSCURRENT PLANNINGmherrera 07/21/2017 LAWNPROPERTY LINE, TYP.PROJECT WORK LIMITSNEW DRIP COVERAGEIN FILTERRA BOXESEXISTING DRIP ZONESFILTERRA BOX- PROVIDE TEMPORARYIRRIGATION UNTIL PLANTINGS AREESTABLISHED.LEGENDNEW DRIP IRRIGATION COVERAGE-SEE DETAIL FOR TYPICAL LAYOUTIRRIGATION NOTES1.MAINTAIN WATER SUPPLY TO EXISTING IRRIGATION. CAP OR INSTALL NEW HEADERAS REQUIRED TO MAINTAIN COVERAGE OF AREAS UNDISTURBED BYCONSTRUCTION. RELOCATE VALVES IF REQUIRED.2.PROVIDE LATERAL CONNECTION FROM EXISTING ADJACENT DRIP ZONES TOFILTERRA STORMWATER BOXES WITH PROPOSED TREES. COORDINATE DRIPLINEINSTALLATION WITHIN FILTERRAS WITH FILTERRA INSTALLERS.FILTERRA CONTACT: CHRIS HASS, CONTECH ENGINEERED SOLUTIONS,CHASS@CONTECHES.COM, 503-310-55393.INSURE PRESSURE IS SUFFICIENT TO SUPPLY ADDITIONAL COVERAGE. IF NOT,INFORM SCHOOL REPRESENTATIVE.4.FOLLOW MANUFACTURER'S INSTRUCTIONS, INCLUDING THOSE REGARDINGFITTINGS AND MAXIMUM LATERAL LENGTH.5.SEE L2.1 SHEET FOR IRRIGATION DETAILS.2215 North 30th Street, Suite 300 Tacoma, WA 98403253.383.2422TEL253.383.2572FAXwww.ahbl.comWEBT A C O M A SEATTLE SPOKANE TRI-CITIESKnow what'sbelow.before you dig.CallR1REVISED PER CITY COMMENTSMGS7/7/17KGLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS LINDBERGH HIGH SCHOOLSOUTH PARKING LOT IMPROVEMENTSRENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS C17-002606PR17-000287 TED-40-3959 IRRIGATION PLANL2.0KEY PLANNNNTSPROJECT LIMITSLINDBERGHHIGH SCHOOL5L2.1R-395916SE 164TH ST128TH AVE SE 132ND AVE SEIN COMPLIANCE WITH CITY OF RENTON STANDARDSCURRENT PLANNINGmherrera 07/21/2017 2215 North 30th Street, Suite 300 Tacoma, WA 98403253.383.2422TEL253.383.2572FAXwww.ahbl.comWEBT A C O M A SEATTLE SPOKANE TRI-CITIESKnow what'sbelow.before you dig.CallR1REVISED PER CITY COMMENTSMGS7/7/17KGLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS LINDBERGH HIGH SCHOOLSOUTH PARKING LOT IMPROVEMENTSRENTON SCHOOL DISTRICTLINDBERGH HIGH SCHOOL SOUTH PARKING LOT IMPROVEMENTS C17-002606PR17-000287 TED-40-3959 LANDSCAPE DETAILSL2.1FINISHED GRADEPAVING SECTION PERCIVIL PLANSCOMPACTED BACKFILLAT 85% DENSITY(SOIL BACKFILL)AT 95% DENSITY(STRUCTURAL)LATERAL LINE(S)SLEEVE(S), 2-TIMESLINE SIZE MIN.MAIN LINE(S)VALVE WIRINGPIPE BED MATERIAL TOBE CLEAN AND FREE OFROCK LARGER THAN1/2-INCH6" OFFSET12" TYPICAL18" TYPICALBEDMATERIAL4"4"4" MIN.4" MIN.4" MIN.4" MIN.24" MINIMUMSAND4"4"NOTES:·DIMENSIONS ARE MINIMUMCLEARANCES.·ALL SLEEVING TRENCH BACKFILLMATERIAL SHALL BE CLASS "B"OR BETTER (MAX. OF 10%PASSING NO.40 SCREEN) AND BECOMPACTED TO MIN. 95%OPTIMUM DENSITY (MODIFIEDPROCTOR).·INSTALL METALLIC DETECTABLEWARNING TAPE 6" ABOVE ALLMAINLINE.·DO NOT TAPE OR BUNDLE WIRESIN SLEEVES.FINISHED SURFACETRENCHINGNTSP-2017-LIN-741DRIP AIR RELIEF VALVE1" = 1'-0"FINISH GRADETECHLINE TUBING3/4" CRUSHED GRAVEL SUMPBRICK SUPPORTS (THREE)TECHLINE 180 2-WAYADAPTER TEEAIR / VACUUM RELIEF VALVE3/4"M X 1/2"F REDUCTION BUSHING6" ROUND VALVE BOX2P-2017-LIN-03DRIP VALVE / FILTER /REGULATORTYPICAL FPT ADAPTERAND COMPRESSIONCOUPLER12" POLYETHYLENE ORPVC HEADERSLOPED CONDITION NOTE:1. INSTALL AIR RELIEF VALVE AT HIGHEST POINT.2. SPACING AS NOTED ON TOP 23 OF SLOPE.3. SPACING AT BOTTOM 13 AS NOTED PLUS 25%.4. WHEN ELEVATION CHANGE IS 10 FT OR MORE, ZONE THE BOTTOM 13SEPARATELY.TYPICAL OFFSET 2" FROMHARDSCAPE, 4" FROMPLANTED AREATYPICAL DRIP LINE WITHEMITTER SPACING ASNOTED. TIE DOWN STAKEAT ALL TEES, ELLS, ANDAT 4' O.C. AT CLAY, 3' O.C.AT LOAM, OR 2' O.C. ATSANDFLUSH VALVE OR CAP ATLOW END, AS NOTEDAIR RELIEF VALVE AT HIGHPOINT, IF INDICATEDMATCH EXISTING DRIPLINESPACING IN EX. BEDSTYPICAL COMPRESSIONFITTINGTYPICAL DRIPLINE LAYOUT1" = 1'-0"3/4" PVC LATERALPIPECENTERFEEDEXAMPLEEND FEED EXAMPLEPVC MAINLINE3P-2017-LIN-06MANUAL LINE FLUSHING VALVE1" = 1"Techline® CV17MM TUBINGFINISH GRADEVALVE BOXSEE SPECSLINE FLUSHINGVALVE TLSOVBRICK SUPPORTS(THREE)3/4" GRAVEL SUMP(1 CUBIC FOOT)SEESPECS 1"4P-2017-LIN-07TECHLINE CV TUBING FOR TREE1" = 1"RVC, FILTER, PRVASSEMBLY- EXISTINGPVC SUPPLY HEADER,CONNECTION FROMEXISTING DRIP ZONEPVC SUPPLY HEADER-CONNECTED THROUGHFILTERRA IRRIGATION HATCHTechline® CV TUBINGEMITTER TYPE ANDROW SPACING PERSPECIFICATIONSEMISSION POINTTREE ROOTBALL- TO BEINSTALLED BY FILTERRAINSTALLERSFILTERRA- SHAPEVARIESMANUAL FLUSHVALVE W/ GRAVEL5P-2017-LIN-09R-395917ROOTBALL PREPARATIONNTSREMOVE EXCESS SOIL ABOVE ROOTFLARE PRIOR TO DIGGING AT NURSERY.CORRECT IN FIELD AT PLANTING IFNECESSARY.SET TRUNK FLARE AT 1" ABOVEFINISHED GRADEREMOVE ALL GIRDLING ANDADVANTAGEOUS ROOTSABOVE TRUNK FLAREFINISHED GRADEREMOVE ALL WIRE BASKET, BURLAP, ORSYNTHETIC MATERIALS FROMROOTBALL (NO EXCEPTIONS). SETROOTBALL ON COMPACTED SOIL TOPREVENT SETTLING.6P-2017-LIN-02ROOTBALLNOTE:1.TREES NOT PLANTED IN CONFORMANCEWITH THIS DETAIL WILL BE REJECTED BYTHE LANDSCAPE ARCHITECT.REPLACEMENT OF REJECTED TREESWILL BE DONE AT THE CONTRACTOR'SEXPENSE.3"-4" HIGH WATERING RINGSCARIFY SIDES OF PLANTING PIT3" MULCH. NO MULCH AGAINSTTRUNKBACKFILL WITH EXISTING SOILDO NOT DISTURB SUBGRADEBELOW ROOTBALL TO REDUCESETTLING.3X ROOTBALLAT TIME OF PLANTING, TRIMDAMAGED BRANCHES.DECIDUOUS TREE PLANTING3/8" = 1'-0"DRIVE STAKES 6"-12" INTOUNDISTURBED SOIL BELOWROOTBALLDRIVE STAKES ATROOTBALL EDGEAPPROVED TREE TIE MATERIALSET LOOSE TO ALLOW FORTRUNK GROWTHSTAKE TREE WITH TWO 2"X2"X8'STAKES SPREAD ACROSS FROMEACH OTHER7P-2017-LIN-016L2.1IN COMPLIANCE WITH CITY OF RENTON STANDARDSCURRENT PLANNINGmherrera 07/21/2017