Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2019-0218 Infiltratoin Test for Previous Failed Location.pdf
Professional Service Industries, Inc. 20508 56th Avenue, Suite A Lynnwood, WA 98036 Phone: (425) 409-2504 Fax: (425) 582-8193 CC: Project: Approved Signatory: Date of Issue: Date:Technician: Report No: DFR:07121464-69 Daily Field Report Issue No: 1 Client: 2/14/2019 RENTON SPECIAL CARE COMM. CS DON ANDERSON, KEVIN CARL, MICHAEL FINCKBONE, TOM ABBOT SR. RENTON SPECIAL CARE COMM. LLC. 2731 77TH AVENUE SE SUITE 203 MERCER ISLAND, WA 98040 Eric Allen RENTON, WA Deborah Priest (Project Engineer) 2/14/2019 These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc. If a non- compliance appears on this report, to the extent that the reported non-compliance impacts the project, the resolution is outside the PSI scope of engagement. Onsite as requested for permeable asphalt infiltration retesting of a previously failing location. The procedure outlined in ASTM C1701M was followed without deviation. 8lbs of water were used. The results are as follows: Prewetting: 42.7s Infiltration Test: 51.1 Infiltration Rate: 137.9 in/hr Page 1 of 1 © 2000-2019 QESTLab by SpectraQEST.com