Loading...
HomeMy WebLinkAboutFilterra Activation_535901-10_Renton Sonic.pdf2018 Renton Sonic 535901-10 Project Name Renton Sonic Project City Renton Project State WA Filterra GPS Location 735 Hardie Ave SW, Renton, WA 98057, USA (47.4728668, -122.2181701) Contech Project Number AND Sequence Number 535901-10 Contech Activation or Third Party Activation Third Party Activation Third Party Project Number 535901-10 Third Party Employee Name David Carnahan Third Party Company Name Rain Gardens Northwest Date of Activation 7/13/18 11:45 AM Filterra System Activation Question Response Details Filterra System Configuration Describe where system is located In the Sonic parking lots just behind the initial row of drive up slots System Type Internal Bypass - Curb Configuration Chamber with Long Side Inlet Size (Interior Dimensions) 12' x 4' (14x4 Vault) Does the System Have a Recessed Top?No Additional Notes / Comments Regarding System Both plants were installed in the photos they look slightly off-center but center of the plants is center of the Vault opening Filterra Activation Checklist Is the throat opening to the Filterra 4" - 6" in height? (not applicable for Internal Bypass - Pipe configurations) N/A Is the site upstream from the Filterra unit stabilized?Yes Photo(s) of stabilized upstream condition Photos 1 7/13/18 11:53 Is the final pavement completed, including striping?Yes Photo(s) of finalized pavement condition Photos 2 7/13/18 11:53 Standing water in bypass structure?No - 1 -535901-10 Renton Sonic Question Response Details Standing Water or Silt in Unit?No Has the Filterra Name Plate Been Installed (On Tree Grate)?Yes Damage to Throat Board? (not applicable for Internal Bypass - Pipe Configurations) No Damage to Tree Grate?No Damage to Box Structure No Damage to Inside of Unit?No Does Clean Out Cover Line up with the Clean Out Pipe?Yes Plant Type?Euonymus winged, burning bush Plant Height Above Grate (ft)0' - 1' Plant Widest Point (ft)1' - 2' Plant Centered in Grate?Yes Plant Need Support?No Bags of Mulch Used 6 Photo of Mulch Bed Photos 3 7/13/18 11:56 Photos 4 7/13/18 11:56 Photo of entire system with tree and grate installed Photos 5 7/13/18 11:57 Lift Loops Filled?Yes - 2 -535901-10 Renton Sonic Question Response Details Silt Fence Required?No Was the plant watered after planting?Yes Is there any evidence irrigation has been provided to the Filterra unit?No Filterra Photos Miscellaneous Photos Photos 6 7/13/18 11:57 Photos 7 7/13/18 11:57 Photos 8 7/13/18 11:57 Photos 9 7/13/18 11:57 Photos 10 7/13/18 11:57 Photos 11 7/13/18 11:57 Is System Activated?Yes The Filterra components have been installed in accordance with Contech Engineered Solutions specifications and recommendations. The tree has been planted, mulch installed, and any items used for shipping have been removed. The system is in new condition, and is considered fully functional and active. Activators Signature David Carnahan - 3 -535901-10 Renton Sonic Photos Photos 1 7/13/18 11:53 Photos 2 7/13/18 11:53 - 4 -535901-10 Renton Sonic Photos 3 7/13/18 11:56 - 5 -535901-10 Renton Sonic Photos 4 7/13/18 11:56 - 6 -535901-10 Renton Sonic Photos 5 7/13/18 11:57 Photos 6 7/13/18 11:57 - 7 -535901-10 Renton Sonic Photos 7 7/13/18 11:57 Photos 8 7/13/18 11:57 - 8 -535901-10 Renton Sonic Photos 9 7/13/18 11:57 Photos 10 7/13/18 11:57 - 9 -535901-10 Renton Sonic Photos 11 7/13/18 11:57 - 10 -535901-10 Renton Sonic