HomeMy WebLinkAboutD_HEX_Decision_First Ukranian Pentecostal Church_190226.pdf1
2
3
4
5
6
7
BEFORE THE HEARING EXAMINER FOR THE CITY OF RENTON
8
9 RE: First Ukranian Pentecostal Church
FINAL DECISION
10 Conditional Use Permit
11 LUA 18-000253, CU-H
12
13
14 Summary
15
The Applicant has applied for a conditional use permit, parking modification and street modification to
16 expand the First Ukranian Pentecostal Church located at 3811 NE 21st St. The applications are
approved subject to conditions.
17
The Applicant's request at the public hearing to approve its street modification request to eliminate a18
planter strip requirement between curb and sidewalk along project frontage is denied for the reasons
19 identified in the last paragraph of Finding of Fact No. 5(D) and Conclusion of Law No. 3.
20 Testimony
21 Angelea Weihs, City of Renton Associate Planner, summarized the staff report. In response to
22 examiner questions Ms. Weihs responded that all pervious portions of the project are landscaped.
23 Imad BahBah, project architect, stated the Applicant is supportive of the staff recommendation except
for the requirement to put a landscaping strip in front of the sidewalk. All other landscaping strips in
24 the area are put behind the sidewalk. For the width of the property, which is about 160 feet along the
25
frontage, it doesn't make sense to have to transition the strip to the front of the sidewalk. There are
also two driveways there, so it is a strange transition point to change the location of the landscaping
26 strip.
CONDITIONAL USE - 1
1
The Examiner asked if there would be any objections to looking to Google earth photographs of the
2 project site to reviewing surrounding frontage landscaping. There were no objections.
3
Ms. Weihs rebutted that abutting properties don't have landscaping between curb and sidewalk
4 because those properties are nonconforming. The new landscaping requirement is a safety requirement
to provide separation between pedestrians and the roadway.
5
6
Exhibits
7
Exhibits 1-15 identified at Page 2 of the February 19, 2019 staff report were admitted into the record
8 during the hearing. The following exhibits were also admitted during the hearing:
9
Exhibit 16: Staff PowerPoint
10 Exhibit 17: City of Renton COR maps
Exhibit 18: Google aerial photographs
11
12
FINDINGS OF FACT
13
Procedural:
14
1. Applicant. Ivan Feltson, First Ukrainian Pentecostal Church, 3811 NE 21st ST, Renton, WA
15 98056.
16
2. Hearing. A hearing was held on the application on February 19, 2019 in the City of Renton
17 Council Chambers.
18 3. Project Description. The Applicant has applied for a conditional use permit, parking
19
modification and street modification to expand the First Ukranian Pentecostal Church located at 3811
NE 21st St. (Parcel nos. 0423059237 and 0423059307). The west parcel (0423059237) is 65,340
20 square feet (1.5 acres) and is developed with an existing church and paved parking areas. The east
parcel (0423059307) is 43,560 square feet (1 acre) and is partially developed with paved and gravel
21 parking. The proposed project includes parking lot expansion, a building addition to the existing
22 church sanctuary, and stormwater infrastructure construction within the two parcels. The existing
church is currently 17,211 square feet. The church sanctuary addition will increase the building size to
23 18,961 square feet. The site currently has 99 parking stalls. The Applicant proposes to add an
additional 77 stalls, for a total of 176 parking stalls. Current access for the site is via two existing curb
24 cuts off of NE 21st St.
25
4. Surrounding Uses. The project site is surrounded by single-family development all zoned as
26 R-6.
CONDITIONAL USE - 2
1
5. Adverse Impacts. There are no significant adverse impacts associated with the proposal.2
Pertinent impacts are more specifically addressed as follows;
3
A. Compatibility/Noise/Light/Glare. As conditioned, the proposal will not create any
4 significant noise or light impacts. Activities and assemblies would be held indoors.
Exterior noise impacts would be limited to vehicles arriving and departing the site. The
5 Applicant states that additional parking lot lighting is proposed in the SEPA checklist
6
Exhibit 14); however, this lighting was not shown on the provided site plan (Exhibit 3).
Details of the lighting plan were not provided with the project application, therefore, a
7 condition of approval requires that an on-site lighting plan be provided with the Civil
Construction permit application demonstrating compliance with RMC 4-4-075, which
8 prohibits light trespass to adjoining properties
9
The proposal is compatible with adjoining development because of the absence of noise
10 and light impacts and the installation of perimeter landscaping to buffer it from adjoining
residential uses as identified in Finding of Fact No. 5(E) and retention of trees as identified
11 in Finding of Fact No. 5(F).
12
B. Critical Areas and Natural Features. There are no critical areas at the project site.
I3
C. Parking. The existing parking complies with the City's parking standards so the proposal
14 is found to provide for adequate parking.
15
The project site currently has 99 existing parking stalls. The Applicant proposes to add an
16 additional 77 stalls, for a total of 176 parking stalls. For religious institutions, the
regulations require a minimum and maximum of 1 for every 5 seats in the main auditorium.
17 Religious institution seating capacity outside of the auditorium is subject to "outdoor and
indoor sports arenas, auditoriums, stadiums, movie theaters, and entertainment clubs" uses,
18 which requires a minimum and maximum of 1 for every 4 fixed seats. The Applicant is
19 proposing a total of 432 seats within the sanctuary, which would require a total of 86
parking stalls. There are a total of 220 seats outside of the sanctuary within the banquet
20 and meeting rooms, which requires a total of 55 parking spaces. The minimum and
maximum number of parking stalls required by the development is 141 parking spaces. The
21 Applicant's proposal exceeds parking requirements.
22
The Applicant has submitted a parking modification request (Exhibit 13) in order to exceed
23 the maximum number of permitted parking stalls by 35 parking spaces, for a total of 176
parking spaces. Of the 176 proposed on-site parking spaces, 6 spaces would be ADA
24 accessible and 92 spaces (52%) would be compact. The maximum number of compact
parking spaces permitted by code per RMC 4-4-080F.8.c.iii, is 30%. The proposed parking25
expansion exceeds the maximum percentage of compact parking spaces; therefore, a
26 condition of approval requires that the Applicant submit a revised site plan and landscape
CONDITIONAL USE - 3
1 plan that demonstrates compliance with maximum compact spaces regulations for review
and approval by the Current Planning Project Manager at the time of Civil Construction
2 Permit.
3
The existing and proposed parking stalls are located on two separate parcels (Parcel nos.
4 0423059237 and 0423059307). Approximately 60 parking spaces are located on the same
lot as the existing church building (parcel number 0423059237). The remaining 116
5
parking spaces are located on a separate parcel (parcel number 0423059307). Both parcels
6 are owned by First Ukrainian Pentecostal Church. In order to ensure that the proposal
complies with minimum parking space regulations, a condition of approval requires that the
7 Applicant submit an application for Lot Combination for Parcel numbers 0423059237 and
0423059307.
8
9
D. Vehicular and Pedestrian Circulation. As determined by City public works staff, the
project assures for adequate and appropriate transportation facilities and the safe
I 0 movement of vehicles and pedestrians.
11 A Traffic Impact Analysis, prepared by Heath & Associates, Inc., dated March of 2018,
12
was submitted with the project application (Exhibit 6). The primary access to the site via
NE 21st Street would be maintained with an inbound driveway and an outbound driveway
13 as currently designed. The church currently has one Sunday morning service and a more
lightly attended Sunday evening service. The report states that the Sunday peak period was
14 targeted for analysis purposes since it generally represents the worst case scenario with
respect to traffic conditions for this church. The report concludes that the proposed church
15 addition and parking expansion will be a moderate generator of new trips in the area with
16 roughly 47 additional total daily trips expected to be generated on a typical Sunday, with
18 of those trips occurring during the Sunday peak hour. A traffic impact analysis is
17 required when the estimated vehicular traffic generated from a proposed development
exceeds 20 vehicles per hour in either the AM (6:00 — 9:00) or PM (3:00 — 6:00) peak
18 periods. The proposed church expansion project does not generate 20 new peak hour trips
19 in the morning or evening peak periods. Therefore, it is not anticipated that the project will
generate traffic that causes significant impacts on the roadway system.
20
Staff had concerns regarding pedestrian safety without the presence of adequate street
21 lighting following public right of way improvements. The nearest street light is more than
22
70 feet away from the project site. Therefore, pursuant to the City of Renton's
Environmental Ordinance and SEPA (RCW 43.21C, 1971 as amended), on January 28,
23 2019, the Environmental Review Committee issued a Determination of Non-Significance -
Mitigated (DNS-M) for the First Ukrainian Pentecostal Church Expansion (Exhibit 9),
24 which required that the Applicant provide one (1) street light within the abutting street
frontage of the property that is consistent with the street lighting standards of RMC 4-6-25 0601 at the time of construction permit application.
26
CONDITIONAL USE - 4
1 As determined by public works staff, if conditions of approval and environmental review
mitigation measures are complied with, it is anticipated that the proposed expansion shall2
ensure safe movement for vehicles and pedestrians and shall mitigate potential effects on
3 the surrounding area.
4 At the hearing, the Applicant requested that the Examiner approve its street modification
request to have the frontage landscaping strip placed behind the sidewalk as opposed to in
5 front, between the curb and sidewalk. The Applicant asserted that placing the planter strip
6 in front of the sidewalk would not have any safety benefits as asserted by staff, due to the
presence of multiple driveways. The Applicant also pointed out that all of the other
7 sidewalks in the vicinity do not have planter strips located between curb and sidewalk. As
identified by staff, the other sidewalks are nonconforming and were constructed prior to
8 the RMC 4-6-060 requirement for planter strips between curb and sidewalk. The
9 Applicant's architect was the person who advocated the street modification at the hearing.
Traffic engineers from the City's public works department are the persons who determined
10 that the planter strip should be retained in its required location for pedestrian safety. The
public works view point is the more compelling on this issue. The presence of the two
11 adjoining driveways on the project's street frontage creates the opportunity for multiple
12 vehicular turning movements occurring at the same time that numerous pedestrians are also
accessing the site. Creating some additional separation between pedestrians and vehicles
13 via the planter stirp does appear to provide for greater pedestrian safety against the turning
movements and traffic circulation caused by the proposal.
14
E. Landscaping. The proposal complies with City landscaping standards and therefore15providesforsufficientlandscaping.
16
A Landscape Plan (Exhibit 11) was submitted with the project application. Per RMC 4-4-
17 070B.1.f, changes in the use of a property or remodel of a structure that requires
improvements equal to or greater than fifty percent (50%) of the assessed property
18 valuation triggers compliance with the landscaping regulations for the entire site. The
19 project proposal is more that 50% of the valuation of both properties based on assessors
records; therefore, compliance with landscaping regulations for the entire site is required.
20 However, there is an exception, Per RMC 4-4-070C.2.e, for alterations or small additions
determined by the Community and Economic Development Administrator not to warrant
21 improvements to the entire site.
22
The pro osal would require perimeter parking lot landscaping, with a minimum depth of 10
23 feet, around the existing and proposed parking lot. The perimeter parking lot landscaping is
required to have a mixture of trees, shrubs, and groundcover per RMC 4-4-070H.4. The
24 Applicant is proposing perimeter landscaping along only the new parking lot expansion.
Compliance with required perimeter landscaping between the existing parking lot and the25
drainage tract (042305TRCT) on the abutting property would require the removal of 23
26 existing parking spaces. The required perimeter parking lot landscaping along this portion
CONDITIONAL USE - 5
401.
1 of the property(in the vicinity of parking stalls number 34-56, as identified on the provided
Landscape Plan), is eliminated pursuant to the above exemption. Based on the provided
2 site plan, no perimeter parking lot landscaping is proposed along the west side of the
3 existing parking lot (along parking stalls numbered 1-14, as identified on the provided
Landscape Plan). Compliance with perimeter landscaping requirements along these parking
4 stalls would not necessitate the removal of existing parking spaces; therefore, in order to
ensure compliance with perimeter parking lot landscaping regulations, a condition of
5 approval requires that a detailed landscape plan be submitted at the time of Utility
6 Construction Permit Review that includes 10 feet of perimeter parking lot landscaping
along parking stalls numbered 1-14. The perimeter parking lot landscaping shall be revised
7 to include a mixture of trees, shrubs and groundcover.
8 In addition to required perimeter parking lot landscaping requirements, the Applicant is
9 required to provide a sight-obscuring visual barrier between the existing church use and the
abutting residential uses. The proposed new parking lot expansion includes a 10-foot wide
10 perimeter landscape strip; however, the provided Landscape Plan does not identify if this
proposed landscape strip is fully sight-obscuring, as required by code; therefore. a
11 condition of approval requires that a detailed landscape plan be submitted at the time of
12
Utility Construction Permit Review that either revises the proposed perimeter landscaping
to be fully site obscuring, or revises the proposal to include 15-feet of partially sight-
13 obscuring landscaped visual barrier, in compliance with RMC 4-4-070F.4.c. The existing
vegetation and trees along the west and south property lines of parcel number 0423059237
14 do not meet the dimensional requirements for landscaping visual barrier regulations per
RMC 4-4-070F.4.c; however, the existing mature trees and landscaping is adequate to
15 screen the existing use from the abutting uses along those property lines; therefore, the
16 project only has to comply with landscaping visual barrier regulations on the new portions
of the parking lot expansion, pursuant to the above exemption.
17
The proposal requires a minimum of 10 feet on site landscaping along the public street
18 frontage (NE 21st Street). The proposal does not account for the approximate 23 feet of
19 public right-of-way (ROW) dedication required along the street frontage. The Applicant
would need to demonstrate compliance with the required 10-foot street frontage
20 landscaping following the required ROW deduction. To ensure that the 10-foot onsite
landscape strip provides the required mix of trees, shrubs, and ground cover, a condition of
21 approval requires that a detailed landscape plan be submitted at the time of Utility
22 Construction Permit Review including the 10-foot onsite landscape strip required along NE
21st Street, that includes a mixture of trees, shrubs and groundcover.
23
The Applicant has indicated that a total of 176 parking spaces would be available upon the
24 completion of the proposed expansion. Based on a minimum requirement of 35 square feet
of landscaping per parking space, a total of 6,160 square feet of landscaping would be
25
required within the surface parking lot. The Applicant indicates that a total of 3,158 square
26 feet of surface parking lot landscaping would be installed on the project site. The provided
CONDITIONAL USE - 6
1 Landscape Plan does not label the proposed groundcover, in addition, not all of the
proposed shrubs meet the minimum size requirement of 2-gallons. The proposal is not
2
compliant with minimum interior parking lot landscaping standards; therefore, a condition
3 of approval requires that a detailed landscape plan and landscape analysis demonstrating
compliance with the parking lot landscaping requirements, as outlined in RMC 4-4-070, be
4 submitted at the time of Utility Construction Permit application for review. The required
landscaping shall be installed prior to Certificate of Occupancy for the building addition.
5
6
F. Tree Retention. The proposal complies with the City's tree retention standards and for
7 that reason is found to provide for sufficient retention of vegetation. A Landscape Plan
Exhibit 11) and Topographical Survey (Exhibit 12) were provided with the project
8 application that identify a total of 15 existing significant (6 caliper inches or greater) trees
9 located on-site. The provided project narrative states that no tree removal is proposed;
however, the landscape plan identifies that two 6-inch caliper trees located within an
10 existing landscape island will be removed. In addition, three 6-inch caliper trees are located
within the proposed (23-foot) public right-of-way dedication and are anticipated for
11 removal following street frontage improvements. Renton Municipal Code, Section 4-4-
12
130H.1.a.i., requires the retention of at least 30 percent (30%) of the significant trees in a
residential or institutional development. Based on a required retention rate of 30 percent, a
13 total of 4 trees would be required to be retained on the project site. The Applicant is
proposing to retain a total of 10 significant trees on-site; therefore, based on the provided
14 landscape plan, the proposal complies with minimum tree retention requirements.
15 Conclusions of Law
16
I. Authority. Hearing examiner conditional use permits qualify as Type III review pursuant to
17 RMC 4-8-080(G). The modification requests are classified by RMC 4-8-080(G) as Type I review.
RMC 4-8-080(C)(2) requires consolidated permits to each be processed under "the highest-number
18
procedure". The Type III conditional use review is the "highest-number procedure" and therefore
19
must be employed for all of the permit applications. As outlined in RMC 4-8-080(G), the Hearing
Examiner is authorized to hold hearings and issue final decisions on Type III applications subject to
20 closed record appeal to the Renton City Council.
21 2. Zoning/Comprehensive Plan Designations. The subject property is within the Residential
22
Medium Density(MD) Comprehensive Plan land use designation and R-6 zoning designation.
23 3. Review Criteria/Street and Parking Modification. RMC 4-2-060 requires a hearing examiner
conditional use permit for religious institutions in the R6 zone. Conditional use criteria are governed
24 by RMC 4-9-030(D). Applicable conditional use standards are quoted below in italics and applied
through corresponding conclusions of law. The requested street and parking modifications are found
25 to be consistent with all applicable criteria for the reasons identified in Findings 19 and 20 of the staff
26 report, adopted by this reference as if set forth in full. At hearing the Applicant requested that the
CONDITIONAL USE - 7
1 Examiner not follow the staff recommendation to deny the Applicant's street modification request to
eliminate the planter strip requirement between curb and sidewalk on the project's street frontage. For2
the reasons identified in Finding of Fact No. 5(D), it is concluded that the modification request must
3 be denied as recommended by staff in order to comply with the safety criteria applicable to the
modification request.
4
The Administrator or designee or the Hearing Examiner shall consider, as applicable, the following5factorsforallapplications:
6
RMC 4-9-030(C)(1): Consistency with Plans and Regulations: The proposed use shall be
7 compatible with the general goals, objectives, policies and standards of the Comprehensive Plan, the
zoning regulations and any other plans,programs, maps or ordinances of the City of Renton.
8
9
4. The proposal is consistent with all applicable comprehensive plan policies and development
standards as outlined in Findings of Fact No. 15 through 17 of the staff report, adopted by this
10 reference as if set forth in full.
11 RMC 4-9-030(C)(2): Appropriate Location: The proposed location shall not result in the
12 detrimental overconcentration of a particular use within the City or within the immediate area of the
proposed use. The proposed location shall be suited for the proposed use.
13
5. The proposed use is compatible with surrounding uses and will create no significant adverse
14 impacts for the reasons identified in Finding of Fact No. 5(A). There is no overconcentration of
church use in the area as the church is located in a single-family neighborhood and the aerial15
photographs of the project site as shown in Ex. 18 do not reveal any other churches or similar uses
16 within several blocks of the project site.
17
RMC 4-9-030(C)(3): Effect on Adjacent Properties: The proposed use at the proposed location18shallnotresultinsubstantialorundueadverseeffectsonadjacentproperty.
19
6. As determined in Finding of Fact No. 5, there are no adverse impacts associated with the
20 proposal, so it will not result in substantial or undue adverse effects on adjacent property.
21 RMC 4-9-030(C)(4): Compatibility: The proposed use shall be compatible with the scale and
22 character of the neighborhood.
23 7. For the reasons identified in Finding of Fact No. 5(A), the proposed use is compatible with the
scale and character of the neighborhood.
24
25
RMC 4-9-030(C)(5): Parking:Adequate parking is, or will be made, available.
26 8. Parking is adequate as determined in Finding of Fact No. 5.
CONDITIONAL USE - 8
1
2
RMC 4-9-030(C)(6): Traffic: The use shall ensure safe movement for vehicles and pedestrians and
shall mitigate potential effects on the surrounding area.
3
9. The proposal provides for safe movement of pedestrians and vehicles and doesn't create
4 adverse traffic impacts as determined in Finding of Fact No. 5(D).
5 RMC 4-9-030(C)(7): Noise, Light and Glare: Potential noise, light and glare impacts from the
6 proposed use shall be evaluated and mitigated.
7 10. As determined in Finding of Fact No. 5(A), the proposal will not result in any adverse light,
noise or glare impacts.
8
9
RMC 4-9-030(C)(8): Landscaping: Landscaping shall be provided in all areas not occupied by
buildings, paving, or critical areas. Additional landscaping may be required to buffer adjacent
10 properties from potentially adverse effects of the proposed use.
11 11. As testified by staff, there are no undeveloped portions of the site without landscaping. As
12 determined in Finding of Fact No. 5, the proposal will involve a significant amount of new perimeter
landscaping to buffer adjacent residential use.
13
DECISION
14
15
The conditional use permit, parking modification and street modification applications satisfy all
applicable review criteria for the reasons identified in the findings and conclusions of this decision and
16 for that reason are approved subject to the following conditions:
17 1. The Applicant shall either revise the proposed impervious surface on both parcel numbers
0423059237 and 0423059307 to comply with maximum impervious surface requirements18
and/or the Applicant shall submit an application for a Lot Line Adjustment with the
19 neighboring parcel to the south (parcel number 0423059068; also owned by the First Ukrainian
Pentecostal Church) in order to modify the lot area to comply with impervious surface
20 requirements. The Lot Line Adjustment shall be submitted for review and approval by the
Current Planning Project Manager, prior to Civil Construction Permit issuance.
21 2. A detailed landscape plan consistent with RMC 4-8-120 shall be submitted for review and
22 approval by the Current Planning Project Manager, prior to Construction Permit Issuance. The
detailed landscape plan shall include, but is not limited to, the following amendments:
23 a. Perimeter parking lot landscaping shall be included along parking stalls numbered 1-14.
b. The proposed perimeter parking lot landscaping shall either be revised to be fully site24obscuring, or shall be revised to include a 15-foot wide, partially sight-obscuring,
25 landscaped visual barrier, in compliance with RMC 4-4-070F.4.c.
c. A 10-foot onsite landscape strip shall be included along NE 21st Street. The landscape
26 strip shall include a mixture of trees, shrubs and groundcover.
CONDITIONAL USE - 9
1 d. The revised Landscape Plan shall demonstrate compliance with the minimum parking
lot landscaping square footage requirements, as outlined in RMC 4-4-070F.6.b.
2 3. The Applicant shall submit a revised site plan that demonstrates compliance with maximum
3 compact parking space regulations for review and approval by the Current Planning Project
Manager prior to Construction Permit issuance.
4 4. An on-site lighting plan shall be provided with the Civil Construction permit application
demonstrating compliance with RMC 4-4-075. The lighting plan shall be reviewed and
5 approved by the current planning project manager prior to Civil Construction permit issuance.
6
5. The Applicant shall replace the existing 15 feet of temporary asphalt sidewalk to the east of the
project frontage with concrete sidewalk meeting City standards. Compliance with this
7 condition shall be demonstrated at the time of Civil Construction permit application.
6. The Applicant shall submit a site plan demonstrating compliance with turning radius fire access
8 requirements for review and approval by the Renton Fire Authority at the time of Civil
9
Construction Permit.
7. With the construction permit application the Applicant shall either: provide an approximate 70-
10 foot long, 8-inch diameter water main extension in order to ensure the Fire Port Connection
FPC) is within 50 feet of the hydrant; or, the Applicant shall provide an alternate layout, with
11 the Double Detector Check Valve Assembly (DDCVA) located in the landscape planter
12
outside the building (which is located within 50 feet of the fire hydrant). Utility plans reflecting
these change shall be reviewed and approval by the Current Planning Project Manager and
13 Development Engineering prior to Construction Permit issuance.
8. The Applicant shall submit an application for Lot Combination for Parcel numbers 0423059237
14 and 0423059307, prior to Civil Construction Permit Application. The Lot Combination shall
be recorded prior to certificate of occupancy of the proposed addition.
15
16
DATED this 26th day of February, 2019.
17
18 G-''.--'''------
Phi A.Olbrnchts
19
20
City of Renton Hearing Examiner
21
Appeal Right and Valuation Notices
22
23 RMC 4-8-080(G) classifies the application(s) subject to this decision as Type III application(s)
24 subject to closed record appeal to the City of Renton City Council. Appeals of the hearing
examiner's decision must be filed within fourteen (14) calendar days from the date of the decision.
25 A request for reconsideration to the hearing examiner may also be filed within this 14-day appeal
period.
26
CONDITIONAL USE - 10
i
1 Affected property owners may request a change in valuation for property tax purposes
notwithstanding any program of revaluation.2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
CONDITIONAL USE - 11
CITY OF RENTON
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT
HEARING EXAMINER DECISION
EXHIBITS
Project Name:
First Ukrainian Pentecostal Church Expansion
Land Use File Number:
LUA18-000253, ECF, CU-H, MOD, MOD
Date of Hearing
February 19, 2019
Staff Contact
Angelea Weihs
Associate Planner
Project Contact/Applicant
Andrey Kovak
First Ukrainian Pentecostal
Church
3811 NE 21st ST, Renton, WA
98056
Project Location
3811 NE 21st ST
The following exhibits are included with the Hearing Examiner Decision:
Exhibits 1-7:As shown in the Environmental Review Committee (ERC) Report
Exhibits 8-15:As shown in the Staff Report to the Hearing Examiner
Exhibit 21:Staff PowerPoint
Exhibit 22:COR Maps, http://rp.rentonwa.gov/Html5Public/Index.html?viewer=CORMaps
Exhibit 23:Google Earth, https://www.google.com/earth/
3/5/2019
1
First Ukrainian Pentecostal
Church Conditional Use Permit
Hearing Examiner Public Hearing
Angelea Weihs, Associate Planner
February 19, 2019
LUA18-000253, CU-H, MOD, MOD
Approvals Requested
The applicant is requesting a Conditional Use Permit, Street
Modification, and Parking Modification in order to expand an
existing religious institution in the R-6 zoning district.
The application was accepted for review on April 4, 2018, and the
application was determined complete on April 30, 2018. The
project was later placed on hold on May 18, 2018, and taken off
hold on December 18, 2018.
Staff received no public or agency comments.
3811 NE 21st St (Parcel nos. 0423059237
and 0423059307)
108,900 square feet (2.5 acres)
Site contains an existing (17,211 SF)
church.
Zoning District – Residential-6 (R-6)
Comprehensive Plan Land Use
Designation – Residential Medium
Density (MD)
Current access for the site is via two
existing curb cuts off of NE 21st St.
No critical areas are mapped on the
project site.
Site Characteristics Environmental Review
On January 28, 2019, the Environmental Review Committee issued a
Determination of Non-Significance - Mitigated (DNS-M) for the project
proposal.
No appeals of the threshold determination have been filed.
The DNS-M included one (1) mitigation measure:
The applicant shall provide one (1) street light within the abutting
street frontage of the property that is consistent with the street
lighting standards of RMC 4-6-060I at the time of construction
permit application.
3/5/2019
2
Project Proposal
Proposal includes a 1,750 square foot addition
to the existing sanctuary.
The proposed addition would increase the
seating capacity within the sanctuary to 432
seats.
There are a total of 220 seats
outside of the sanctuary within
the banquet and meeting rooms
The applicant proposes to expand
the parking lot by 77 parking
stalls, for a total of 176 parking
stalls.
No residential units or subdivision
is proposed with this proposal.
Zoning Development Standards
The proposal would comply with all setback, building coverage, building
height, and tree retention regulations following expansion.
The proposal exceeds maximum impervious surface requirements.
The proposal does not comply with on-site fire turning radius
requirements.
Zoning Development Standards:
Landscaping Parking Modification
Religious institutions require a minimum and maximum of 1
parking stall for every 5 seats in the main auditorium.
Seating capacity outside of the auditorium is subject to
“outdoor and indoor sports arenas, auditoriums, stadiums,
movie theaters, and entertainment clubs” uses, which
requires a minimum and maximum of 1 space for every 4
fixed seats.
The project proposal requires a minimum and maximum of
141 parking spaces.
The applicant submitted a parking modification request in
order to allow for the construction of 176 on-site parking
spaces, rather than the required 176 parking spaces.
Provided conditions of approval are met, the proposal
complies with modification criteria.
3/5/2019
3
Street Modification
The applicant submitted a street modification request in order to:
Reduce the public ROW width from 23 feet to 20 feet.
Align the required new curb with the existing curb located east of the site.
Remove the required 8-foot wide landscaped planter between the curb and sidewalk.
Staff recommends approval in part and denial in part of the requested modification.
Conditional Use
Permit Analysis
Effects on Adjacent Properties
Appropriate Location
Consistency with Plans and Regulations
Compatibility
Parking
Noise, Light, and Glare
Landscaping
Traffic
Public Services
Stormwater:
The provided TIR and drainage plan are not in compliance with the
2017 Renton Surface Water Design Manual. A revised TIR and
drainage plan will be required at the time of construction permit
application.
A revised Geotechnical Report that is consistent with the revised TIR
will be required.
Water:
A fire department connection (FDC) is required to be within 50 feet of a
fire hydrant or in a location approved by the Renton Regional Fire
Authority.
Recommendation
Staff recommends approval of the First Ukrainian Pentecostal Church Expansion Conditional Use
Permit and Parking Modification, and partial approval/partial denial of the requested Street
Modification, File No. LUA18-000253, ECF, CU-H, subject to the eight (8) conditions of approval:
1. The applicant shall either revise the proposed impervious surface on both parcel numbers 0423059237 and 0423059307 to comply with maximum impervious surface
requirements and/or the applicant shall submit an application for a Lot Line Adjustment with the neighboring parcel to the south (parcel number 0423059068; also
owned by the First Ukrainian Pentecostal Church) in order to modify the lot area to comply with impervious surface requirements. The Lot Line Adjustment shall be
submitted for reviewand approval by the Current PlanningProjectManager, priorto Civil Construction Permit issuance.
2. A detailed landscape plan consistent with RMC 4-8-120 shall be submitted for review and approval by the Current Planning ProjectManager, prior to Construction
Permit Issuance. The detailed landscape plan shall include, but is not limited to, the following amendments:
a. Perimeter parking lot landscaping shall be included along parking stalls numbered 1-14.
b. The proposed perimeter parking lot landscaping shall either be revised to be fully site obscuring, or shall be revised to include a 15-foot wide, partially sight-
obscuring, landscaped visual barrier, in compliance with RMC 4-4-070F.4.c.
c. A 10-foot onsite landscape strip shall be included along NE 21st Street. The landscape strip shall include a mixture of trees, shrubs and groundcover.
d. The revised Landscape Plan shall demonstrate compliance with the minimum parking lot landscaping square footage requirements,as outlined in RMC 4-4-
070F.6.b.
3. The applicant shall submit a revised site plan that demonstrates compliance with maximum compact parking space regulations for review and approval by the Current
Planning Project Manager prior to Construction Permit issuance.
4. An on-site lighting plan shall be provided with the Civil Construction permit application demonstrating compliance with RMC 4-4-075. The lighting plan shall be reviewed
and approved by the current planning project manager prior to Civil Construction permit issuance.
5. The applicant shall replace the existing 15 feet of temporary asphalt sidewalk to the east of the project frontage with concrete sidewalk meeting City standards.
Compliance with this condition shall be demonstrated at the time of Civil Construction permit application.
6. The applicant shall submit a site plan demonstrating compliance with turning radius fire access requirements for review and approval by the Renton Fire Authority at
the time of Civil Construction Permit.
7. With the construction permit application the applicant shall either: provide an approximate 70-foot long, 8-inch diameter water main extension in order to ensure the
Fire Port Connection (FPC) is within 50 feet of the hydrant; or, the applicant shall provide an alternate layout, with the Double Detector Check Valve Assembly (DDCVA)
located in the landscape planter outside the building (which is located within 50 feet of the fire hydrant). Utility plans reflecting these change shall be reviewed and
approval by the Current Planning Project Manager and Development Engineering prior to Construction Permit issuance.
8. The applicant shall submit an application for Lot Combination for Parcel numbers 0423059237 and 0423059307, prior to Civil Construction Permit Application. The Lot
Combination shall be recorded prior to certificate of occupancy of the proposed addition.