Loading...
HomeMy WebLinkAboutKing County Interceptor Noise Variance HEX PP.pdfKing County Eastside Interceptor Noise Variance Hearing Examiner Public Hearing Alex Morganroth, Associate Planner February 26th, 2019 LUA18-000684, VA-H Approvals Requested The applicant, King County Wastewater, is requesting a Noise Variance in order to exceed the maximum nighttime noise limits in RMC 8-7. The application was accepted for review on November 29, 2018 and the application was determined complete on December 3, 2018. The project was put on-hold on December 28th, 2018 in order to allow the applicant time to update the noise study, and was taken off-hold on January 18th, 2019 after the updated noise study was submitted. Staff received no public or agency comments. A Tier 2 Temporary Use Permit was approved on November 14, 2018, that will allow the establishment of two staging areas for equipment associated with the project. Project Background Rehabilitation of the Eastside Interceptor Section 2, a 96-inch reinforced concrete pipe Work to occur primarily in Logan Ave N ROW between N 6th St and Lake Washington Blvd N Two staging areas on north and south side of site Electric bypass pumps would operate continuously at the north staging area. Work would occur between spring of 2019 and spring of 2020 for a total of approximately 8 months. Applicant will be requesting temporary closer of approximately 100 feet of Burnett Ave N (Council approval required) EDNA (Environmental Designations for Noise Abatement) Class A EDNA –Residential properties Class B EDNA –Commercial properties -exempt from night-time limits for temporary construction sites. Class C EDNA –Industrial properties –exempt from night- time limits for temporary construction sites. Noise Limits Per RMC 8-7-2 and WAC 173-60-040 Maximum Night-time (10pm to 7am) Noise Limits •Noise limit is reduced by 10 dBA for Class A receiving properties •Class B or C EDNA (commercial or industrial) properties –exempt from night-time limits for temporary construction sites. Predicted Noise Levels (bypass install and operation) (from bypass pump area) Predicted Noise Levels (pipe lining) Proposed Mitigation Measures Use only ambient-sensing broadband back-up alarms and minimize backing Noisy equipment and construction activities performed as far as possible from noise sensitive areas Monitor noise levels during construction Limit engine idling to 5 minutes or less Use radios for long-range communication; only use raised voices and public address systems in an emergency Install noise barrier or noise curtains of similar design to what is previously described around noisier equipment Use electric and hydraulic equipment in lieu of diesel of pneumatic equipment Perform impact work during times of high ambient sound levels Variance Analysis Variance approval is the minimum that will accomplish the desired purpose Variance will not be materially detrimental to the public health, welfare or safety, or unduly injurious to the property or improvements Applicant Suffers Practical Difficulties Variance contains such conditions deemed to be necessary to limit the impact of the variance on the residence or property owners impacted Compliant if Conditional of Approval are met Compliant if Conditions of Approval are met 1.The applicant shall provide the City’s project manager with the after-hours noise complaint phone number prior to the start of construction, and a summary of any complaints and the response provided, within 5 days of receiving the complaint. 2.The applicant shall implement proposed noise mitigation measures to diminish or eliminate noise during construction. Additional mitigation measures to diminish or eliminate noise during construction are to be provided by the applicant as necessary. 3.The applicant shall provide notice to the City’s project manager of the date and areas of expected night work, a minimum of 24 hours in advance of the work. Recommendation Staff recommends approval of the Noise Variance for the King County Eastside Interceptor Rehabilitation Project, File No. LUA18-000684, VA-H, subject to three (3) condition of approval: Predicted Noise Levels Nighttime Bypass Pump Install and Removal Nighttime Operation Sound Levels for Bypass Pumps (Mitigated)