Loading...
HomeMy WebLinkAboutR-394415SE 1/4 ,SECTION 26, TOWNSHIP 23N, RANGE 4 E, W.M. DRAINAGE NOTES AND DETAILS SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS co p CITY OF RENTON LU 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. z 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, Cw G BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION w (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. U Q 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, n WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL w REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY op SECTION. Q J 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN C/) PROGRESS. H Q 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED z O BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED - ON THE PLANS. (D � 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING >_ CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. z p 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN U CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS (D DEPARTMENT, SURFACE WATER UTILITY SECTION. Z_ V 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY U) J THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN p ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD r) SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE z TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF Q REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE w SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH I—THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT O AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 z INCHES OVER AND UNDER PVC PIPE. W Q 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE z ASPHALT TREATMENT # 1 OR BETTER INSIDE AND OUTSIDE. Q 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE Ir) PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS ADMINISTRATOR. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE a SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. w 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER o DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. U i w 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, N PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND w SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK a COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL U 4- TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 o TRAFFIC CONTROL SHALL APPLY. 0 0 0 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER m PROTECTION AREA (APA). I E O M 0 N 0 0 0 ID o1 w NO. REVISION a z iZ cN N I VAULT WIDTH Q A I I I I I I I I II II I I I I I I I I I I I I I I SDR 35 OUTLET COUPLING CAST INTO PRECAST VAULT WALL (OUTLET PIPE LOCATION MAY VARY) ENERGY DISSIPATION ROCKS PLANT PROVIDED BY CONTECH 2"0 IRRIGATION PORT, PLACES 1 t INLET SHAPING (NOT BY CONTECH) I A I I UNDERDRAIN FLOWKIT LL 4' CURB INLET (MAX) CURB (NOT BY CONTECH) J GALVANIZED ANGLE NOSING CURB AND GUTTER (NOT BY CONTECH) SEE FILTERRA BIOSCAPE VAULT CURB INLET DETAIL SHEET STREET J C s � � z I I 4' CURB INLET (MAX) 116 .Ali-------ic�rE;-------------- -------------_� 6" UNDERDRAIN 3" MULCH LAYER, TYP. STONE LAYER, TYP. PROVIDED BY CONTECH PROVIDED BY CONTECH 4" - 6"0 UNDERDRAIN 21" FILTERRA MEDIA, TYP. FLOWKIT (VARIES BY SIZE) PROVIDED BY CONTECH PROVIDED BY CONTECH SECTION A -A SECTION B-B SECTION C-C FTBSV LONG SIDE INLET CONFIGURATION DESIGNATION AVAILABILITY MEDIA BAY SIZE VAULT SIZE (L x W) OUTLET PIPE DIA FTBSV0604 N/A CA 6 x 4 6 x 4 4" SDR 35 FTBSV06504 CA ONLY 6.5 x 4 6.5x4 4" SDR 35 FTBSV078045 MID-ATL ONLY 7.83 x 4.5 7.83 x 4.5 4" SDR 35 FTBSV0804 N/A MID-ATL 8 x 4 8 x 4 4" SDR 35 FTBSV0806 ALL 8 x 6 8 x 6 4" SDR 35 FTBSV1006 ALL 10 x 6 10 x 6 6" SDR 35 FTBSV1206 ALL 12 x 6 12 x 6 6" SDR 35 FTBSV1307 ALL 13 x 7 13 x 7 6" SDR 35 FTBSV1408* CALL CONTECH 14 x 8 14 x 8 6" SDR 35 FTBSV1608* CALL CONTECH 16 x 8 16 x 8 6" SDR 35 FTBSV1808* CALL CONTECH 18 x 8 18 x 8 6" SDR 35 FTBSV2008* CALL CONTECH 20 x 8 20 x 8 6" SDR 35 FTBSV2208* CALL CONTECH 22 x 8 22 x 8 6" SDR 35 N/A = NOT AVAILABLE 'UTILIZES (2) 4' CURB OPENINGS W/ V SPACING C7.3 SURVEYED: AALA DESIGNED: GXLE DAWN` SGR CHECKED: AGC BY DATE APPR APPROVED:AGC WOINTA FTBSV SHORT SIDE INLET CONFIGURATION DESIGNATION AVAILABILITY MEDIA BAY SIZE VAULT SIZE (W x L) OUTLET PIPE DIA FTBSVO406 N/A CA 4 x 6 4 x 6 4" SDR 35 FTBSVO4065 CA ONLY 4x6.5 4 x 6.5 4" SDR 35 FTBSVO408 N/A MID-ATL 4 x 8 4 x 8 4" SDR 35 FTBSVO45078 MID-ATL ONLY 4.5 x 7.83 4.5 x 7.83 4" SDR 35 FTBSVO608 ALL 6 x 8 6 x 8 4" SDR 35 FTBSV0610 ALL 6 x 10 6 x 10 6" SDR 35 FTBSVO612 ALL 6 x 12 6 x 12 6" SDR 35 FTBSV0713 ALL 7 x 13 7 x 13 6" SDR 35 N/A = NOT AVAILABLE APE FILI SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 4' CURB INLET (MAX) V m FTBSV SQUARE INLET CONFIGURATION DESIGNATION AVAILABILITY MEDIA BAY SIZE VAULT SIZE (W x L) OUTLET PIPE DIA FTBSV0404 ALL 4 x 4 4 x 4 4" SDR 7 FT55VO606 ALL 6 x 6 6 x 6 4" SDR 35 N/A = NOT AVAILABLE inbrmatim shown on Nis d-iM is provided. a.a b the projeC-,, ergineer aM...- wMmmneeMofGa AFdWre-plyledon. MNeuseft v e.k COMedrevpreeafydlw efitterra `+,4'0V I'm 'm 0 "+" ENGINEERED SOLLITIONS LLC www.ContLchES.com 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M INTERNAL PIPE CONFIGURATION MAY VARY DEPENDING ON VAULT SIZE. S bffty r or arw of idi aFn'lpn mmpe n('Cardepll . NeNwr Nia drawing, mr d pert Nereo( may d uead, id wndl d or modifiatl in any mood. melblpty for wM ux. M d{wrepantlrs bebwren Ne suppllal IMmmtlon upon whipl Ne drewlig Is bead end ecba� Reld mndldra ere en^nuMered as Yb FILTERRA BIOSCAPE VAULT OFFLINE (FTBSV) CONFIGURATION DETAIL OR APPROVED EQUAL • CITY OF RENTON NUIf."R Planning/Building/Public Works Dept 0 0 0 0 C6 �, 00 IZI- 0 O I T W V 00 r O N I CV N I L0 z CALL BEFORE YOU DIG LU 2 LU Call: TOLL FREE U Q J 1-800-424-5555 uJ m Q J IN COMPLIANCE WITH CITY OF RENTON STANDARDS U) LL I Q SURFACE WATER UTILITY DEVELOPMENT ENGINEERING * Q rstraka 11 /29/2018 rnair 11 /30/2018 z w1cDAVID EVANS ANDASSOCIATES INC. 14432 SE Eastgate Way, Suite 400 Bellevue Washington 98007 _O (D Lu KING COUNTY REGIONAL DATE. 1/3/2018 z AFIS LAB REPLACEMENT FIELDBOOK: PAGE: O DRAWING NO: U DRAINAGE NOTES AND 07.3 0 Z DETAILS sHEET.16 OF: 135 Y R-399415