FINISH GR,
SECTION/ELEVATION
LEGEND
1. FINISH GRADE.
2. CONTROL WIRES WITH 36" SERVICE COIL
AND WATER PROOF WIRE CONNECTIONS,
DBY OR EQUAL.
3. RECTANGULAR PLASTIC VALVE BOX. HEAT
BRAND STATION NUMBER ON LID IN 2" HIGH
CHARACTERS.
4. PVC MAINLINE PER SPECIFICATIONS
(LENGTH AS REQUIRED).
5. SH 40 PVC ELL (SxS).
6. NATIVE SOIL PER SPECIFICATIONS.
7. CONTROL WIRES TO CONTROLLER.
8. PVC MAINLINE FITTING.
9. TORO TPVF100 INLINE VALVE (*).
DRIP CONTROL ZONE KIT
NOT TO SCALE
SE 1/4 ,SECTION 26, TOWNSHIP 23N, RANGE 4 E, W.M.
IRRIGATION DETAILS
10. TORO 150 MESH Y-FILTER (*).
11. TORO 25 PSI LOW FLOW PRESSURE
12. REGULATOR (*).
13. SCH 40 PVC MALE ADAPTER.
14. SCH 40 PVC BALL VALVE (*).
15. 2" MINUS GRAVEL SUMP, MINIMUM 6" DEEP.
16 BRICK SUPPORTS (4 COMMON BRICKS
REQUIRED).
17. LATERAL LINE TO DRIP SYSTEM.
TOP OF MULCH
BARBED TEE/FITTINGS
TOPSOIL
IRRIGATION DRIPLINE-
(® 2 FOOT APART)
FINISH GRADE
TIE DOWN STAKE
(*) PARTS IN DRIP ZONE KIT.
2-3" BURIAL DEPTH
LANDSCAPE STAPLES
® 2' O.C.
IRRIGATION DRIPLINE
NOT TO SCALE
BALL VALVE
NOT TO SCALE
''_INE SIZE)
CZ
I
FI ON
MAINLINE
UOUS BRICK
G
gSHED GRAVEL
LEGEND
�w \-
Li w -
cn
LIJ
C)�wLL
woc
Z 0 Z L
oQD �
cV W
J
U
HARDSCAPE SURFACE
CLEAN BACKFILL AS REQUIRED. TO
BE SET IN 6" LIFTS. REFER TO
SPECIFICATIONS FOR SPECIFIC
MATERIAL AND COMPACTION
REQUIREMENTS.
INSTALL UNDERGROUND UTILITY
LINE MARKING TAPE OVER MAINLINE
LATERAL LINE WITH SLEEVE
INSTALL UNDERGROUND UTILITY LINE
TRACE COPPER WIRE OVER MAINLINE
PRESSURE MAIN LINE WITH SLEEVE
CLEAN SAND
CONTROL WIRES SLEEVE
NOTES:
1. ALL SLEEVES TO BE PVC. SCH. 40 AND TWICE THE DIAMETER OF THE WORKING PIPE.
2. ALL SLEEVES TO RUN A MIN. OF 12" BEYOND HARDSCAPE EDGES.
3. CLEAN BACKFILL MAY BE SUBSTITUTED FOR SAND UNDER WALKS AND DRIVES.
IRRIGATION SLEEVING
NOT TO SCALE
1. FINISH GRADE 6. PVC TEE (SxSxT) WITH 1/2"
FPT OUTLET.
2. DRIPLINE
7. 2-3" DEPTH OF DRIPLINE
3. TORO LOC-EZE TEE
8. DEPTH OF PVC SUPPLY
4. POLY TUBING LATERAL PER PLANS.
DRIPLINE CENTER -FEED SUPPLY
MANIFOLD
NOT TO SCALE
NO.
REVISION
NUIE:
1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED
IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET
SI ZE.
LEGEND
1. 6" ROUND POLY VALVE BOX. 4. PVC LATERAL.
2. AIR/VACUUM RELIEF VALVE. 5. 2" MINUS WASHED
GRAVEL.
3. TORO LOC-EZE X 1 /2" FPT
TEE (FTF16). 6• BRICK SUPPORTS (2
COMMON BRICKS
REQUIRED).
AIR RELIEF VALVE
NOT TO SCALE
SURVEYED: n n I n
DESIGNED: JCGA
DRAWN: G B K
CHECKED: UI GA
BY DATE APPR APPROVED:
ICGA
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
)UICK COUPLER VALVE
NOT TO SCALE
VERTICAL: NAVD 1988
HORIZONTAL- NAD 1983/1991
DATU M
SOIL BACKFILL
FREE OF ROCK
FINISH GRADE
BRASS QUICK -COUPLING VALVE
POLY VALVE BOX WITH LOCKING
LID
S' MINIMUM DEPTH OF
"' MINUS
WASHED GRAVEL
PVC SCH 80 NIPPLE
(LENGTH
AS REQUIRED)
BRICK (1 OF 2)
PVC SCH 80 NIPPLE
(LENGTH
AS REQUIRED)
PVC SCH 40 STREET
ELL
PVC SCH 40 TEE OR
ELL
PVC MAINLINE PIPE
PVC SCH 40 ELL
PVC SCH 40 STREET ELL
#4 REBAR WITH STAINLESS
STEEL CLAMPS (LENGTH AS
NEEDED FOR SUPPORT)
FINISH GRADE - SEED MIX
OR BARK MULCH
LATERAL PIPE LINE
00 >
INSTALL UNDERGROUND
= UTILITY LINE MARKING
-
- TAPE OVER MAINLINE
N
o
-III
IIIIIII INSTALL UNDERGROUND
III= UTILITY LINE TRACE
COPPER WIRE OVER
MAINLINE
0
PVC MAINLINE
CONTROL CABLES
;,..
CLEAN SAND BED
TRENCH DETAIL
NOT TO SCALE
•
CITY OF
RENTON
•
Planning/Building/Public Works Dept.
0
0
0
0
T
U
O
0
O
T
Q
D
J
W
co
CO
Qo
0
z
W
w
U
Q
J
n
LU
00
Q
J
IN COMPLIANCE WITH CITY OF RENTON STANDARDS U)
PLANNING DIVISION
,R APPROVED
11 /29/2018 jding
NAVID EVANS
ANDASSOCIATES INC.
14432 SE Eastgate Way, Suite 400
Bellevue Washington 98007
CALL BEFORE YOU DIG
Call: TOLL FREE
-800-424-5555
KING COUNTY REGIONAL
AFIS LAB REPLACEMENT
IRRIGATION DETAILS
IL
Q
J
z
O
0
w
DATE:
01-16-18
Z
Z)
FIELDBOOK:
PAGE:
O
U
DRAWING NO:
L1.3
0
SHEET: OF:
22
135
Y
R-399421