A PORTIGN OF THE SW 1�4 OF THE NW1/4 CITY OF RENTON PERWT NUMBER C 18005570 Ohl 7000385
SECTION 32, TOWNSHP 24 N, RANGE = E W.M. B17003480-V3
CITY OF RENTON, WASHINGTON
NTI:IIa iI011241
2" CLOSE NIPPLE
2" 90' ELBOW
CONCRETE BLOCKING
TWO PIECE CAST IRON VALVE —
EQUAL TO OLYMPIC FOUNDRY CO.
STANDARD 8" TOP SECTION,
WITH REGULAR BASE SECTION
LENGTH TO FIT.
2" RESILIENT SEATED `
GATE VALVE, SCREWED
2" GALVANIZED \
PIPE 12" LONG
2" CLOSE NIPPLE —
2"CLOSE
BETWEEN CAP OR
LE PLUG r `
AND 2" 90' ELBOW
IF ADDITIONAL ADJUSTMENT IS
REQUIRED, INSTA-L 2-2" CLOSE
NIPPLE AND 2-2" 90' BEND, SCREWED
AT THIS POINT. FIELD LOCATE PLASTIC METER BOX IN
— f PLANTER OR CAST IRON BOX IN PAVFD
F I� OR CONCRETE AREAS.
2" CLOSE NIPPLE
2" 90' ELBOW
2" GALVANIZED PIPE AS REQUIRED
PLAN
VALVE NUT EXTENSION AS REQUIRED
r (SEE DWG BR46 / PAGE B090)
GROUND LINE CONCRETE SIDEWALK
6" MAX.
INST4�L 4 MIL POLYETHYLENE o ° a° oa °cc° � o
PLASTIC COVER OVER WASHED 18" MAX. 0o0C)'n c,0000
GRAVEL. CUT HOLE FOR PIPE °� 00 oo°,00
o 0o c0o"oc
10 CU. FT. WASHED GRAVEL PASSING
1-1/2" AND RETAINED ON 1/4" MESH
FOR DRAIN
ELEVATION
2 1 /2" NST (HOSE)
AND 2 1/2" FNST
CAP WITH GASKET
2"x2%2" TEE AND 2" CAP
2" CLOSE NIPPLE BEWTEEN TEE
AND 90' ELBOW.
2" 90' ELBOW
"e► PUBLIC WORKS 2" BLOW -OFF STD. PLAN - 340.1
DEPARTMENT PERMANENT ASSEMBLY
N i0� MARCH 2O10
13"x24" PLASTIC METER BOX EQUAL TO MID -STATES PLASTIC,
INC. BCF SERIES MSBC- 1324-18 WITH 1.75" THICK DUCTILE
IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PLASTICS,
INC. MSCBC-1324-R WITH READER LID AND 2" DRILLED HOLE
FOR TOUCHREAD PIT LID (SEE DETAIL A -A)
9" MIN _
12" MAX
FINISH GRADE
z I IN UNIMPROVED RIGHT OF
J
WAY INSTALL METER BOX AT
PROPERTY LIVE WITH 12"
E LONG COPPER TAILPIECE.
w
a I � SIDEWALK
a I
CITY PRIVATE
PIPING PIPING
Z ¢ TOUCHREAD WATER
> METER TO BE 12"
36" MIN COVER cal SUPPLIED BY THE Q
ro
CITY 0 C,
TYPE "K" SOFT N o
COPPER TUBING
22-1 /2'
NEW DUCTILE
IRON
WATERMAIN
IF SERVICE LINE TO HOUSE IS 3/4" OR 1"
TO BE INSTALLED IN THE FUTURE GALVANIZED
INSTALL FORD C14-33 OR 44 FPT PLUG
x COMPRESSION COLP_ING
/ LOOP DOWN CENTERLINE
OF WATER MAIN TO
PROVIDE SLACK IN COPPER COPPERSETTER FOR 5/8"x3/4" METER: FORD
SERVICE LINE TO METER. VBH72-15W-44-33G, OR McDONALD BRASS: 21-215WC0033, OR
MUELLER: 3/4-B-2470-2 WITH ANGLE BALL VALVE ON INLET AND
SINGLE CHECK VALVE ON OUTLET
CORPORATION STOP WITH BALL VALVE. FORD COPPERSETTER FOR 1" METER: FORD VBH72-15W-44-44G, OR
TAPERED THREAD (CC). QUICK JOINT MCDONALD BRASS: 21-415WCQQ44, OR MUELLER: 1-B-2470-2
BOTH I\LET AND OUTLET WITH QUICK JOINT. PADLOCK WINGS ON
(1" F61000-4-Q) OR AY MCDONALD 47018 INLET ANCLE BALL VALVE AND SINGLE CHECK VALVE ON OUTLET.
ALL FITTINGS SHALL BE WITH QUICK JOINT.
NOTE:
ALL METER BOXES INSTALLED WITHIN CONCRETE OR PAVED DRIVEWAYS SHALL BE
CAST-IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOIN-S MUSH BE INSTALLED ON
BOTH SIDES OF METER BOX.
AA DRILL 2" DIA. HOLE FOR AMR (AUTOMATIC
METER READ) TOUCHREAD DEVICE
2-1/2" MIN. FROM NEAREST
AND FRONT EDGE OF PIT LID
TYPICAL
RIB
NOTE:
THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM
UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE
NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN
ONE RIB.
PUBLIC WORKS 1" WATER SERVICE STD. PLAN - 320.1
x�
'•`,+ DEPARTMENT
NOVEMBER 2009
SURVEYED:
TOUMA
DESIGNED:
A N S T E Y 8627 NE 180th St. TOUMA
DRAWN:
BOTHELL, WA 98011 DAN
E N G I N E E R I N G PHONE: (206) 303-7639 CHECKED:
EMAIL: benonstey@ansteyengineering.com
2/2/2019 N0. REVISION BY DATE APPR APPROVED:
WATER PLAN GENERAL NOTES Standard Plan No. 300
1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS
STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS
AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION
IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR
AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION.
2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL
CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION.
3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND
"CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY
MATERIALS ON -SITE.
4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C
104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS
PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE,
POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS.
5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS
AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES.
ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR,
THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER.
PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH
BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST
METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED
AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD.
6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF
RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS
AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO
CONCRETE BLOCKING.
7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED,
DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE
SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALLAND REMOVE PLUGS,
CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO
CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL
THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITYTESTING.
8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING
PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING
THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED,
AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR.
9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING
DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER
MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR
THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND
ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE
CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION.
Y o STD. PLAN — 300.0
+ PUBLIC WORKS WATER PLAN GENERAL NOTES
�' DEPARTMENT
t N To MARCH 2O10
SCALE:
VERTICAL-• Y CITY 0 F
1 "=20' HORIZONTAL-NAD AD 1983/183/1991 � p
RENTON
ONE INCH N T 0
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
W-403306_
APPROVED FOR CONSTRUCTION
SUBJECT TO ERRORS AND OMISSIONS
in
DEVELOPMENT ENGINEERING' WATER UTILITY
Justin Johnson 02/05/2019Ul
Abdoul Gafour 02/05/2019
3731 PARK AVE N
WATER NOTES AND DETAILS
PERMIT NUMBER C 18005570
9/12/2018
FIELDBOOK:
PAGE:
DRAWING NO:
525-380
SHEET:
OF:
6