Loading...
HomeMy WebLinkAboutW-403307L' J 0 N CITY OF RENTON PERWT NUMBER z Iv 0 TESTING DETAIL F to w 111 FT L 'cl\NEW D.I. WATER LINE TAPPING TEE (MJxF�) VERTICAL CROSS(MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG TAPPING GATE VALVE (FL XMJ) 1-BEND TEMPORARY PLUG (MJ) WITH 2-INCH TAP ND FLANGE ON 60TTOM AND 2-INCH BLOW -OFF ASSEMBLY 1-PLUGARY BLOCK WITH "L"TAP & 2" BLOW -OFF CONCRETE BLOCKING TEMPORARY w Z J 3 0 cv .FINAL CONNECTION DETAIL z F N w NEW D.I. WATER LINE (TR ALL CLEANING BY POLYPIG, PRESSURE TESTING AND DISINFECTION, REMOVE TEMPORAY BLOCK & BLOW -OFF AND CONNECT TO VALVE WITH D.I. SLEEVE (MJ) & D.I. SPOOLS FINAL CONNECTON BY CITY FORCES NOTES: 1 TAPPING TEES SHALL BE MADE OF CAST IRON, DUCTILE IRON OR EPDXY -COATED STEEL. BOLTS AND NUTS SHAL BE COR-TEN. ALL TEES AND VALVE SHALL BE WATER TESTED BCQORE TAP 2. NO SIZE ON SIZE TAPS ON CAST -IRO\ WATER L.NES. TAP SHALL BE AT LEAST 2" SMALLER DIAMETER THAN THE EXISTING MAIN. 3. NO WET TAP ON ASBESTOS CEMENT LINE OR STEEL LINE 4. WET -TAPPING OF EXISTING CITY OF RENTON WATER MAINS WILL BE DONE BY SPEER TAP OR SUPERIOR TAPPING INC. 5. CONTRACTOR SHALL POTHOLE AND VERIFY T'iE HORIZONTAL AND VERTICAL ALIGNMEN" OF EXISTING LINE OR STUB .AND SHALL START LAYING THE NEW UNE AT --E SAME HORIZONTAL AND VERTICAL ALIGNMENT OF THE EXISTING STUB. 6. CITY FORCES WILL PERFORM THE FINAL CONNECTION FROM THE WATER LINE TO THE TAPPING VALVE WITH D.I. SLEEVE AND D.I. SPOOL. e STD. PLAN - 300.1 PUBLIC: WORKS CONNECTION TO WATER MAIN WITHDEPARTMENT TAPPING TEE & VALVE MARCH 2O10 2/2/2019 C 18005570 FINISHED GRADE ELEVATION 3 FT MIN. COVER (10-INCH DIAMETER AND UNDER) 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) NEW WATER MAIN POLYPIG VERTICAL CROSS FOR POLYPIGGING STATION: A PORTION SECTION 32, CITY TEMPORARY 2" GALVANIZED PIPE AND 2" GATE VALVE INS'ALL 2" PLUG ON TOP BLIND FLANGL AFTER REMOVAL OF POLYPIG SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS (MJ X FL) ONE BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW -OFF ASSEMBLY (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY -PIG") ONE BLIND FLANGE ON BOTTOM OF CROSS ONE PLUG (MJ) ON END OF CROSS CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECHON OF NEW WATER MAIN TY PUBLIC WORKS POLY PIG STATION FOR CLEANING OF STD. PLAN - 300.6 DEPARTMENT WATER MAINS MARCH 2O10 A N S T E= Y 8627 NE 180th St. BOTHELL, WA 98011 E N G I N E E R I N G PHONE: (206) 303-7639 EMAIL: benanstey@ansteyengineering.com OF THE SIN 1/4 OF THE NW TOWNSHP 24 N, RANGE 5 E, OF RENTON. WASHINGTON 7 u 11-1/4' BEND CAP ..l 22-1/2' BEND TEE 45" BEND 90' BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FOR HORIZONTAL AND DOWNWARD VERTICAL BENDS SOIL FIRM SILT OR FlRM SILTY SAND COMPACT SAND CCMPACT SAND & GRAVEL 90" 45' BEND 11 1/4" 90' 45' BEND 11 1/4' 90' 45' BEND 11 1/4' FITTING BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2' BEND TEE CAP OR PLUG & 22 1/2` BEND BEND BEND 4" 7.0 4.2 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.6 1.6 1.0 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 B" 23.3 ', 6.7 16.7 6.7 11.7 8.4 8.4 3.4 5.8 6.3 6.3 2.5 12" 53.0 37.5 37.5 15.0 "15 18.8 18.8 7.5 20.0 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE. 3'-O" MIN. COVER FOR WATERMAIN LESS THAN 12". 4'-0" MIN. COVER FOR WATERMAIN 12" OR GREATER, MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' TRUST BLOCK BE. REA REFERS TO ' 4CE OF BLOCK M IN SQIJARF FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. ALL BLOCKING SHALL BE CONCRETE CL 5 (1-I/2"). 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE CREATES F [TING SURFACE AREA POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED, �1Y ° CONCRETE BLOCKING FOR STD. PLAN - 330.2 u PUBLIC WORKS + i�� + DEPARTMENT VERTICAL AND DOWNWARD l N SO VERTICAL BENDS MARCH 2010 PRI 7000385 BI 7003480-V3 FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-5"0 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPFR CENTURION 200, AND WATEROUS PACER WITH 6" MFCHANICAL JOINT INLET WITH -UGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAP-OR, 4.875" SEATTLE THREAD X 5' STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-MOORE/PRESERVATIVE PAINT C. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MIN. 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF 3' SIDEWALK THAT IS ADJACENT TO CURB 4.675" x 5" STORZ 5'x5x6° THICK CONCRETE PAD AROUND BACK OF HYDRANT. FINISH TO MATCH SIDEWALK. EWALK EXPANSION JOID NT AT 2 ORNPLANTNGDST/RIP CONCRETE THRUST BLOCK 15" x 8" x 4" MININUM CONCRETE BEARING HLOCK UNDER HYDRANT 1 �6 CUT 36" MIN COVER TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION AS REQUIRED. RAISED PAVEMENT MARKER TYPE 88-A STIMSONITE TWO-WAY BLUE REFLECTIV= CONCRETE BLOCKING \, MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6 DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" CCR-TEN STEEL TIE RODS. 1/2 YARD OF 1-1/4" WASHED DRAIN ROCK 1' ABOVE BOOT FLANGE. PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL. FIRE HYDRANT ASSEMBLY I FVEL ALL GROUND MIN S RADIUS ONE MAN ROCK- 6 6" CONCRETE PAD LEVEL ALL GROUND MIN 3' RADIUS 6" CONCRETE PAD FI LL HYDRANT LOCATION IN CUT OR FILL STD. PLAN - 310.1 PUBLIC WORKS FIRE HYDRANT ASSEMBLY -` DEPARTMENT MARCH 2O1U W-403307 APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS DEVELOPMENT ENGINEERING I WATER UTILITY Y Justin Johnson 02/05/2019 E)l , Abdoul Gafour 02/05/2019 '� SURVEYED: SCALE:SCALE. 1 "- 2 0$ VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 Y CITY OF itRENTON 2 3731 PARK A V E N WATER NOTES AND DETAILS DESIGNED: TOUMA DRAWN: DAN N t O ONE INCH Planning/Building/Public Works Dept, PERMIT NUMBER C 18005570 CHECKED: MITT AT FULL SCALE IF NOT ONE INCH N 0. REVISION BY DATE AP P R SCALE ACCORDINGLY APPROVED: 9/12/2018 PAGE: DRAWING NO: 525-380 SHEET: OF: 7 7