HomeMy WebLinkAboutP_Renton SCC As-Built Plans_181213_v1.pdf167
167
108TH AVE SESE
116TH AVE SE116TH AVE SEBENSON RD SEAST VALLEY RDS 43RD ST BENSON RD SSE 172ND ST
SE 176TH STPROJECT
RDBENSON DR S19 20
30 29
29 28
32 33
30 29
31 32
20 21
29 28
CARRPROJECT INFORMATIONSITE ADDRESS:
TAX PARCELS:
CURRENT ZONING:
17033 108TH AVE SE, RENTON, WA 98055
R-14
65,715 SF (1.51 AC)
PROPOSED USE:
0087000285, 0087000293
FRONT:SETBACKS:
GROSS SITE AREA:
EXISTING USE:
CURRENT COMP PLAN:R-14
15'
REAR:10'
SIDE:
SIDE (ALONG STREET):15'
PARKING REQUIRED:
REQUIRED=
PARKING PROVIDED:26 STALLS
25%%% REDUCTION=
4'
COMPACT STALLS ALLOWABLE:8 STALLS
COMPACT STALLS PROVIDED:7 STALLS
ADA STALLS REQUIRED:2 STALLS
ADA STALLS PROVIDED:2 STALLS
WATER:SOOS CREEK WATER & SEWER DISTRICT
SEWER:
SCHOOL DISTRICT:RENTON #403
POWER:PSE
FIRE DISTRICT:RENTON RFA
GAS:PSE
SOOS CREEK WATER & SEWER DISTRICT
TELEPHONE:CENTURYLINK
CABLE:COMCAST
CONVALESCENT CENTER - CONDITIONAL USE
SINGLE-FAMILY RESIDENTIAL
REFUSE AND RECYCLING AREA
PROVIDED:
REQUIRED RECYCLE:
REQUIRED GARBAGE:102 SF
51 SF
OPEN SPACE REQUIREMENTS
MINIMUM OPEN SPACE REQUIRED:0 SF IF THREE OR FEWER DWELLING UNITS
180 SF
26 STALLS
34 STALLS
MAXIMUM BUILDING HEIGHT:35'
350 SF PER UNIT IF 4 OR MORE DWELLING UNITS
IMPERVIOUS REQUIREMENTS
MAXIMUM IMPERVIOUS:80%%%
MAXIMUM LOT COVERAGE:65%%%
NET SITE AREA 61,150 SF (1.40 AC)
ROW DEDICATION AREA:4,565 SF (0.10 AC)
NEW IMPERVIOUS:43,072 SF (70.40%%%)
NEW PERVIOUS:
LOT COVERAGE:17,306 SF (28.30%%%)
18,078 SF
SEISMIC DESIGN CATEGORY:D
IBC DESIGNATION OF OCCUPANCY:4-1
STRUCTURAL DESIGN CRITERIA:LOAD OF 30 TON VEHICLE, 75 PSI, AND
26"x26" OUTRIGGER PER RENTON RFA
COTTAGE BCOTTAGE CCOTTAGE DCOTTAGE ALOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED INVOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON.
TOGETHER WITH:
THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLATTHEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY,WASHINGTON.
SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.
LEGAL DESCRIPTIONSURVEY INFORMATIONEQUIPMENT & PROCEDURESVERTICAL DATUM - NAVD-88{\Q15;NORTH AMERICAN VERTICAL DATUM-1988}BENCHMARKBENCHMARK
BASIS OF BEARING{\Q15;THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01%%D43'32" E}SEPA MITIGATION CONDITIONSPER LUA 17-000023 ECF, CUP MITIGATION MEASURES ARE NONE RECOMMENDED
NPDES PERMIT NUMBER
WAR 305778 CONTACT LISTOWNER/APPLICANT:
LANDSCAPE ARCHITECT:
{ELM ENVIROMENTS1925 POST ALLEY, SUITE 3BSEATTLE, WASHINGTON 98101CONTACT: GREG MURPHYPHONE: (206) 393-8263EMAIL: gmurphy@elmenv.com}
{RENTON SPECIAL CARE COMMUNITY, LLC2731 77TH AVE SE, SUITE 203MERCER ISLAND, WASHINGTON 98040CONTACT: KEVIN CARL}PHONE: (206) 778-4725kevin@magnet-dd.com
CIVIL ENGINEER:
LDC, INC.20210 142ND AVE NEWOODINVILLE, WASHINGTON 98072CONTACT: MARK VILL{W}OCK, PEPHONE: (425) 806-1869{FAX: (425) 482-2893}EMAIL: mvillock@ldccorp.com
ARCHITECT:
GEOTECH:
JENSEN FEY ARCHITECTURE ANDPLANNING P.S.7730 LEARY WAYREDMOND, WASHINGTON 98052CONTACT: REUBEN RIOSPHONE: (425) 216-0318EMAIL: rrios@jensenfey.com
PROFESSIONAL SERVICE INDUSTRIES, INC. (PSI)20508 56TH AVENUE WEST, SUITE ALYNNWOOD, WASHINGTON 98036GEOTECH CONTACT: MICHAEL S. PLACE, PEPHONE: (425) 409-2504{FAX: (425) 582-8193}EMAIL: michael.place@psiusa.com
SURVEYOR:
{LDC, INC.20210 142ND AVE NEWOODINVILLE, WASHINGTON 98072CONTACT: MICHAEL MERRITT, PLS, CFedSPHONE: (425) 806-1869FAX: (425) 482-2893EMAIL: michaelm@ldccorp.com}
CESCL:
{INTERTEK-PSI20508 56TH AVE W, SUITE ALYNWOOD, WA 98043CONTACT: MICHAEL S. PLACE, PEPHONE: (425) 409-2505EMAIL: michael.place@psiusa.com}
HEARING EXAMINER'S REQUIREMENTS
1. A LOT COMBINATION SHALL BE RECORDED PRIOR TO THEISSUANCE OF A BUILDING PERMIT, COMBINING THE TWOPARCELS INTO ONE.2. A DETAILED LANDSCAPE PLAN MEETING THEREQUIREMENTS OF RMC 4-8-120D.12 SHALL BE SUBMITTEDAT THE TIME OF BUILDING PERMIT REVIEW. THE DETAILEDLANDSCAPE PLAN SHALL INCLUDE BUT IS NOT LIMITED TOTHE FOLLOWING:A. A MIX OF TREES, SHRUBS, AND GROUND COVER WITHINTHE 10-FOOT LANDSCAPE STRIP ABUTTING THE SE 172NDSTREET AND 108TH AVENUE SE STREET FRONTAGES;B. THE PROPOSED 10-FOOT FULL SIGHT-OBSCURINGLANDSCAPE VISUAL BARRIER ALONG THE WEST PROPERTYLINE SHALL BE REQUIRED TO EXTEND ALONG THE NORTHPROPERTY LINE; ANDC. VERIFICATION THAT THE INTERIOR PARKING LOTLANDSCAPED AREAS INCLUDE 1 SHRUB PER 20 SQUAREFEET OF PROVIDED INTERIOR PARKING LOT LANDSCAPING,OF WHICH 50 PERCENT OF THE SHRUBS MAY BEDECIDUOUS. THE DETAILED LANDSCAPE PLAN SHALL BE SUBMITTED TOTHE CURRENT PLANNING PROJECT MANAGER FOR REVIEWAND APPROVAL. THE LANDSCAPING SHALL BE INSTALLEDPRIOR TO THE ISSUANCE OF A CERTIFICATE OFOCCUPANCY.3. THE APPLICANT SHALL EITHER REDUCE THE HEIGHT OFTHE FENCE TO COMPLY WITH THE 72-INCH HEIGHTREQUIREMENT OR SUBMIT AN APPLICATION FOR, ANDRECEIVE APPROVAL OF, A SPECIAL FENCE PERMIT INCOMPLIANCE WITH THE STANDARDS OUTLINED IN RMC4-4-040G. THE APPLICANT SHALL SUBMIT A REVISED FENCEDETAIL OR AN APPROVED SPECIAL FENCE PERMIT TO THECURRENT PLANNING PROJECT MANAGER PRIOR TO THEISSUANCE OF A BUILDING PERMIT.4. THE DESIGN OF THE BUILDINGS SHALL BE REQUIRED TOCOMPLY WITH THE RESIDENTIAL DESIGN PORTION OF THERESIDENTIAL DESIGN AND OPEN SPACES STANDARDSAPPLICABLE IN THE R-14 ZONE (RMC 4-2-115E.3) ANDENHANCED LANDSCAPING BE PROVIDED WHERECOMPLIANCE WITH THE ARCHITECTURAL DESIGN CANNOTBE ACHIEVED.5. A LIGHTING PLAN SHALL BE PROVIDED AT THE TIME OFBUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL BYTHE CURRENT PLANNING PROJECT MANAGER.6. THE LOCATION OF THE REQUIRED BICYCLE PARKINGSHALL BE PROVIDED ON THE SITE PLAN AND A DETAIL OFTHE BICYCLE PARKING SHALL BE PROVIDED. THE REVISEDSITE PLAN AND BICYCLE PARKING DETAIL SHALL BEPROVIDED AT THE TIME OF BUILDING PERMIT REVIEW TOTHE CURRENT PLANNING PROJECT MANAGER FOR REVIEWAND APPROVAL.7. A SIDEWALK CONNECTION SHALL BE PROVIDED TO SE172ND STREET ALONG THE WESTERN PORTION OF THEPROJECT SITE.8. ALL PROPOSED LOADING AREAS SHALL BE SEPARATEDFROM PARKING AND PEDESTRIAN AREAS AND SHALL BELOCATED, DESIGNED AND SCREENED TO MINIMIZE VIEWS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18VICINITY MAPSCALE: 1"=2000'
RENTON SPECIAL
CARE COMMUNITYSCALE: 1" =
0
40'
40'40'80'COVER SHEET1"=30'
CS-01
230AS-BUILT DRAWINGS
TABLE OF CONTENTS
1 COVER SHEET2 EXISTING CONDITIONS MAP
3 HORIZONTAL CONTROL PLAN
4 SITE PLAN5 TESC PLAN
6-7TESC NOTES AND DETAILS
8 GRADING PLAN9 DETAILED GRADING PLAN10 {\Q15;ROAD AND STORM DRAINAGE PLAN}11-15{\Q15;ROAD AND STORM DRAINAGE PROFILES}
16 ROAD SECTIONS
17 {\Q15;STORM DRAINAGE DETENTION PLAN}18 {\Q15;COMPOSITE UTILITY PLAN}19-23{\Q15;NOTES AND DETAILS}
WA-01 - WA-05 WATER PLANS
SS-01 - SS-06SEWER PLANSL000 TREE INVENTORY AND RETENTION PLAN
L100-L301 LANDSCAPE PLANS
ES-01 - ES-03 LIGHTING PLANS70.30'(R4)661.35'(P)
661.23'(R2)719.94'(R3)158.38'(C)719.91'(M)
N88%%D07'55"E
N88%%D13'13"W
70.31'(C)158.39'(C)N88%%D07'55"W 300.54'(C)300.62'(P)139.15'(P)139.24'(C)70.34'(C)70.30'(R4)SE 172ND ST{BLOCK 4LOT 14}
{BLOCK 4LOT 13}
{BLOCK 4LOT 15}
{BLOCK 4LOT 12}
STORM PIPE
STORM CLEAN OUT
ROUND YARD DRAIN
SQUARE YARD DRAIN
TYPE 2 CATCH BASIN, SOLID LID
TYPE 2 CATCH BASIN, GRATED LID
TYPE 1 CATCH BASIN, SOLID LID
TYPE 1 CATCH BASIN, GRATED LID
SD CAP
CONCRETE BLOCKING
90%%d BEND
VALVE
HYDRANT ASSEMBLY
BLOW-OFF VALVE
REDUCER
AIR-VAC ASSEMBLY
DESCRIPTIONSYMBOL
PROPOSED WATER SYMBOLS
PROPOSED STORM SYMBOLS
SYMBOL DESCRIPTION
WATER PIPE
SEWER CLEANOUT
SEWER MANHOLE
DESCRIPTIONSYMBOL
PROPOSED SEWER SYMBOLS
SEWER PIPE
EXISTING SYMBOLS
DESCRIPTIONSYMBOL
ABBREVIATIONS
SANITARY SEWER MANHOLESSMH
PP POWER POLE
EXIST.EXISTING
CATCH BASINCB
PROPERTY LINE
FLOWLINE%%132CENTERLINE
CONCRETE PIPECP
TYPICALTYP
ELEVATIONEL
R/W RIGHT-OF-WAY
CMP CORRUGATED METAL PIPE
INVERT ELEVATIONIE
SS SANITARY SEWER
STORM DRAINSD
STATIONSTA
LCPE LINED CORRUGATED POLYETHYLENE PIPE
POLYVINYL CHLORIDE PIPEPVC
SWPE SOLID WALL POLYETHYLENE PIPE
TO BE REMOVEDTBR
SEWER CAP
LEGEND AND ABBREVIATIONS
WATER METER
S
T
FOUND CASED MONUMENT, AS NOTED
FOUND REBAR & CAP, AS NOTED
SET REBAR AND CAP
STORM DRAIN MANHOLE
STORM DRAIN CATCH BASIN
SANITARY SEWER MANHOLE
NATURAL GAS VALVE
FIRE HYDRANT
WATER VALVE
WATER METER
BOLLARD
POWER POLE W/LIGHT
TELEPHONE MANHOLE
MAPLE TREE
CEDAR TREE
POWER POLE
299.81'(C)
DRIVE A
DRIVE A
58.68'(R2)
SET REBAR AND CAPEMW LS#44651
108TH AVE SE
1274.24'(P)1275.03'(M)\pxql;FOUND REBAR AND CAP CRONES LIES 0.32' N17°W OF PROPERTY CORNER
SET REBAR AND CAPEMW LS#44651
\pxt0;FOUND 1.5" PIPE 0.85' N11°W OF PROPERTY CORNER
SET REBAR AND CAPEMW LS#44651
\pxql;FOUND CASED MONUMENT
SET REBAR AND CAPEMW #44651
SET REBAR AND CAPEMW LS#44651
FOUND CASED MONUMENT W/TACK
FOUNDCASEDMONUMENT
SET REBAR AND CAPEMW LS#44651
\pxql;FOUND CASED MONUMENT
LANDSCAPE NOTES
\pxi-2,l2,t2;1. LANDSCAPE PLAN WILL BE REVISE TO MATCH STREET LIGHT LOCATIONS ON THE CIVIL PLANS AND TREE LOCATIONS WILL BE ADJUSTED ACCORDINGLY.
106TH AVE SE 3842.13'N56°49'35"W
2554.59'N30°05'55"E702.23'CITY OF RENTON MON#1862 (C, HORZONLY)COPPER PLUG WITH PUNCH ON A 4"X4"CONCRETE POST, IN CASE, DOWN 0.45'.PUBLISHED CO-ORDS:N=168056.01E=1300198.93FOUND CO-ORDS:N=168056.34
CITY OF RENTON MON#1640 (D, HORZ & ELEV)3" BRASS DISC STAMPED "KING COUNTY SURVEYMONUMENT", IN CASE, DOWN 1.0'.PUBLISHED CO-ORDS:N=170648.98E=1305835.75ELEV=466.09FOUND CO-OORDS:N=170649.17E=1305835.94ELEV=465.87
CITY OF RENTON MON#1915 (B, ELEV ONLY)COPPER PLUG IN A 3" CONCRETE FILLED PIPE IN AWSDOT CASE. DOWN 0.30'.PUBLISHED CO-ORDS:ELEV=380.86FOUND CO-OORDS:ELEV=380.70
AS-BUILT DRAWINGSRecord Drawings shall be prepared, stamped, and signed by a Professional Engineer or Professional Land Surveyor Licensed in the State
of Washington. All plans showing as-built information in the Record Drawings and the cover sheet of the Record Drawings shall include
a stamp that indicates that the plan sheet contains as-built information. The stamp shall be labeled “Construction Record Drawing”. The
stamp shall indicate how the as-built information was obtained and that the professional stamping the plan sheet takes ownership for the
contents of the plan sheet. Something like the following:
SCALE: 1" =
0
20'
20'20'40'
S
T
FOUND CASED MONUMENT, AS NOTED
FOUND REBAR & CAP, AS NOTED
SET REBAR AND CAP
STORM DRAIN MANHOLE
STORM DRAIN CATCH BASIN
SANITARY SEWER MANHOLE
NATURAL GAS VALVE
FIRE HYDRANT
WATER VALVE
WATER METER
BOLLARD
POWER POLE W/LIGHT
TELEPHONE MANHOLE
MAPLE TREE
CEDAR TREE
POWER POLE
LEGEND
R-396202
EXISTING CONDITIONS MAP
1"=20'
TO-01
2321FOUND CASED MONUMENTW/TACK
N88%%D07'55"W158.39'(C)70.31'(C)N88%%D13'13"W 299.81'(C)139.24'(C)1275.03'(M)300.62'(P)300.54'(C)158.38'(C)139.15'(P)1274.24'(P)661.23'(R2)70.30'(R4)70.34'(C)70.30'(R4)661.35'(P)
719.91'(M)719.94'(R3)SSMHRIM=410.63'IE=397.96'(N,S,E 8" PVC)
SSMHRIM=412.67'IE=398.48'(N,S,E,W)IE=404.71'(N,8")
N88%%D07'55"E
106TH AVE SE TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
CITY OF RENTON MON#1915 (B, ELEVONLY)COPPER PLUG IN A 3" CONCRETE FILLEDPIPE IN A WSDOT CASE. DOWN 0.30'.PUBLISHED CO-ORDS:ELEV=380.86FOUND CO-OORDS:
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-183842.13'CITY OF RENTON MON#1640 (D, HORZ & ELEV)3" BRASS DISC STAMPED "KING COUNTY SURVEYMONUMENT", IN CASE, DOWN 1.0'.PUBLISHED CO-ORDS:N=170648.98E=1305835.75ELEV=466.09FOUND CO-OORDS:N=170649.17E=1305835.94ELEV=465.87
N56°49'35"W
2554.59'
CITY OF RENTON MON#1862 (C, HORZ ONLY)COPPER PLUG WITH PUNCH ON A 4"X4"CONCRETE POST, IN CASE, DOWN 0.45'.PUBLISHED CO-ORDS:N=168056.01E=1300198.93FOUND CO-ORDS:N=168056.34E=1300199.16 AS-BUILT DRAWINGS
PROJECT INFORMATIONSITE ADDRESS:
TAX PARCELS:
CURRENT ZONING:
17033 108TH AVE SE, RENTON, WA 98055
R-14
65,715 SF (1.51 AC)
PROPOSED USE:
0087000285, 0087000293
FRONT:SETBACKS:
GROSS SITE AREA:
EXISTING USE:
CURRENT COMP PLAN:R-14
15'
REAR:10'
SIDE:
SIDE (ALONG STREET):15'
PARKING REQUIRED:
REQUIRED=
PARKING PROVIDED:26 STALLS
25%%% REDUCTION=
4'
COMPACT STALLS ALLOWABLE:8 STALLS
COMPACT STALLS PROVIDED:7 STALLS
ADA STALLS REQUIRED:2 STALLS
ADA STALLS PROVIDED:2 STALLS
WATER:SOOS CREEK WATER & SEWER DISTRICT
SEWER:
SCHOOL DISTRICT:RENTON #403
POWER:PSE
FIRE DISTRICT:RENTON RFA
GAS:PSE
SOOS CREEK WATER & SEWER DISTRICT
TELEPHONE:CENTURYLINK
CABLE:COMCAST
CONVALESCENT CENTER - CONDITIONAL USE
SINGLE-FAMILY RESIDENTIAL
REFUSE AND RECYCLING AREA
PROVIDED:
REQUIRED RECYCLE:
REQUIRED GARBAGE:102 SF
51 SF
OPEN SPACE REQUIREMENTS
MINIMUM OPEN SPACE REQUIRED:0 SF IF THREE OR FEWER DWELLING UNITS
180 SF
26 STALLS
34 STALLS
MAXIMUM BUILDING HEIGHT:35'
350 SF PER UNIT IF 4 OR MORE DWELLING UNITSIMPERVIOUS REQUIREMENTS
MAXIMUM IMPERVIOUS:80%%%
MAXIMUM LOT COVERAGE:65%%%
NET SITE AREA 61,150 SF (1.40 AC)
ROW DEDICATION AREA:4,565 SF (0.10 AC)
NEW IMPERVIOUS:43,072 SF (70.40%%%)
NEW PERVIOUS:
LOT COVERAGE:17,306 SF (28.30%%%)
18,078 SF
SEISMIC DESIGN CATEGORY:D
IBC DESIGNATION OF OCCUPANCY:4-1
STRUCTURAL DESIGN CRITERIA:LOAD OF 30 TON VEHICLE, 75 PSI, AND
26"x26" OUTRIGGER PER RENTON RFA
LOT 14, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED INVOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON.
TOGETHER WITH:
THE SOUTH HALF OF LOT 15, BLOCK 4, AKER'S FARM NO. 5, ACCORDING TO THE PLATTHEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY,WASHINGTON.
SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.
LEGAL DESCRIPTIONSURVEY INFORMATIONEQUIPMENT & PROCEDURESVERTICAL DATUM - NAVD-88{\Q15;NORTH AMERICAN VERTICAL DATUM-1988}BENCHMARKBENCHMARK
BASIS OF BEARING{\Q15;THE MONUMENTED CENTERLINE OF 108TH AVE. S.E., AS THE BEARING OF N 01%%D43'32" E}
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396203
HORIZONTAL CONTROL PLAN
1"=20'
HC-01
232\A1;15.6'\A1;45.9'\A1;101.3'\A1;101.3'\A1;52.6'
\A1;52.6'\A1;100.2'\A1;57.8'
15.5'R/WDEDICATION\A1;23.6'\A1;30.5'\A1;20.5'
4.5' R/W DEDICATION
30'EX R/W\A1;30'
\A1;EX R/W
\A1;18.6'60'EX R/W10' LANDSCAPE BUFFER
\A1;R25'
\A1;R45'\A1;69.8'\A1;44.5'\A1;40.3'\A1;71'
30'EX R/W
\A1;30'\A1;30'FOUND CASED MONUMENTW/TACK
SCALE: 1" =
0
20'
20'20'40'
N88%%D07'55"W158.39'(C)70.31'(C)N88%%D13'13"W 299.81'(C)139.24'(C)1275.03'(M)300.62'(P)300.54'(C)158.38'(C)139.15'(P)1274.24'(P)661.23'(R2)70.30'(R4)70.34'(C)661.35'(P)
719.91'(M)
3'X6' WATER EASEMENT(REC. NO. 8008130467)(TO BE RELINQUISHED)
719.94'(R3)
N88%%D07'55"E
INTERSECTION, ROAD %%132
STA 0+00.00, DRIVE A=
STA 16+89.94, SE 172ND ST
N=166701.26
E=1302727.41
N=166859.58
E=1302732.27
N=166929.86
E=1302734.43
N=166920.54
E=1303034.10
N=166711.06
E=1303027.78
N=166850.23
E=1303031.98
INTERSECTION, ROAD %%132
STA 5+19.12, DRIVE A=
STA 12+13.23, 108TH AVE SE
\A1;30'\A1;EX R/W15'x12' POWER ESMT
3'X6' WATER ESMT
\A1;10'
SDESMT
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
\A1;10'
SDESMT\A1;20' CITYEMERGENCYACCESS ESMT\A1;20' CITY
EMERGENCYACCESS ESMT
16'WATER &SEWER ESMT
106TH AVE SE \A1;64.1'\A1;BUILDING SETBACK\A1;15.3'
\A1;39'\A1;52.6'\A1;15.3'
TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
INTERSECTION, ROAD %%132
STA 20+00.00, SE 172ND ST
STA 10+00.00, 108TH AVE SE=
CITY OF RENTON MON#1915 (B, ELEV ONLY)COPPER PLUG IN A 3" CONCRETE FILLED PIPE IN AWSDOT CASE. DOWN 0.30'.PUBLISHED CO-ORDS:ELEV=380.86FOUND CO-OORDS:ELEV=380.70
N56°49'35"W
2554.59'
CITY OF RENTON MON#1862 (C, HORZONLY)COPPER PLUG WITH PUNCH ON A 4"X4"CONCRETE POST, IN CASE, DOWN 0.45'.PUBLISHED CO-ORDS:N=168056.01E=1300198.93FOUND CO-ORDS:N=168056.34
N30°05'55"E702.23'3842.13'CITY OF RENTON MON#1640 (D, HORZ & ELEV)3" BRASS DISC STAMPED "KING COUNTY SURVEYMONUMENT", IN CASE, DOWN 1.0'.PUBLISHED CO-ORDS:N=170648.98E=1305835.75ELEV=466.09FOUND CO-OORDS:N=170649.17E=1305835.94ELEV=465.87
\A1;10'GASESMT\A1;10'GASESMT\A1;57'
\A1;UTILITY ESMT \A1;20' SD ESMT\A1;UTILITY ESMT\A1;WIDTH VARIES\A1;18'
WATER&SEWER \A1;15'WATERESMT\A1;10'WATERESMT\A1;15'WATERAS-BUILT DRAWINGS
PROJECT INFORMATIONSITE ADDRESS:
TAX PARCELS:
CURRENT ZONING:
17033 108TH AVE SE, RENTON, WA 98055
R-14
65,715 SF (1.51 AC)
PROPOSED USE:
0087000285, 0087000293
FRONT:SETBACKS:
GROSS SITE AREA:
EXISTING USE:
CURRENT COMP PLAN:R-14
15'
REAR:10'
SIDE:
SIDE (ALONG STREET):15'
PARKING REQUIRED:
REQUIRED=
PARKING PROVIDED:26 STALLS
25%%% REDUCTION=
4'
COMPACT STALLS ALLOWABLE:8 STALLS
COMPACT STALLS PROVIDED:7 STALLS
ADA STALLS REQUIRED:2 STALLS
ADA STALLS PROVIDED:2 STALLS
WATER:SOOS CREEK WATER & SEWER DISTRICT
SEWER:
SCHOOL DISTRICT:RENTON #403
POWER:PSE
FIRE DISTRICT:RENTON RFA
GAS:PSE
SOOS CREEK WATER & SEWER DISTRICT
TELEPHONE:CENTURYLINK
CABLE:COMCAST
CONVALESCENT CENTER - CONDITIONAL USE
SINGLE-FAMILY RESIDENTIAL
REFUSE AND RECYCLING AREA
PROVIDED:
REQUIRED RECYCLE:
REQUIRED GARBAGE:102 SF
51 SF
OPEN SPACE REQUIREMENTS
MINIMUM OPEN SPACE REQUIRED:0 SF IF THREE OR FEWER DWELLING UNITS
180 SF
26 STALLS
34 STALLS
MAXIMUM BUILDING HEIGHT:35'
350 SF PER UNIT IF 4 OR MORE DWELLING UNITSIMPERVIOUS REQUIREMENTS
MAXIMUM IMPERVIOUS:80%%%
MAXIMUM LOT COVERAGE:65%%%
NET SITE AREA 61,150 SF (1.40 AC)
ROW DEDICATION AREA:4,565 SF (0.10 AC)
NEW IMPERVIOUS:43,072 SF (70.40%%%)
NEW PERVIOUS:
LOT COVERAGE:17,306 SF (28.30%%%)
18,078 SF
SEISMIC DESIGN CATEGORY:D
IBC DESIGNATION OF OCCUPANCY:4-1
STRUCTURAL DESIGN CRITERIA:LOAD OF 30 TON VEHICLE, 75 PSI, AND
26"x26" OUTRIGGER PER RENTON RFA
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18\A1;16'9'TYP\A1;20'\A1;24'\A1;DRIVE AISLE\A1;20'
\A1;DRIVE AISLE
\A1;27'\A1;24'\A1;45.9'\A1;52.6'\A1;101.3'\A1;101.3'
\A1;52.6'
\A1;52.6'\A1;100.2'\A1;57.8'\A1;23.6'\A1;31.7'15.5' R/W DEDICATION
4.5' R/W DEDICATION \A1;8'22'
PVMT\A1;30' EX R/W
\A1;18.6'10' LANDSCAPE BUFFER \A1;20' CITYEMERGENCYACCESS ESMT\A1;R25'
\A1;R45'\A1;69.8'\A1;24'\A1;DRIVE AISLE
\A1;64.1'\A1;44.5'\A1;20'\A1;9'\A1;40.3'SCALE: 1" =
0
20'
20'20'40'
\A1;11'22.2'PVMT
\A1;26'128.72'
LEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
ROOFLINE
\A1;30'1275.03'(M)1274.24'(P)R-396204SITE PLAN1"=20'
SP-01
233FOUND CASED MONUMENTW/TACK 9'TYP4.51'15.50'
N88°07'55"E 273.74'
COVERED REFUSE AND RECYCLING AREA
DRIVE A
10' LANDSCAPE BUFFER
FUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT
15'x12' POWER ESMT.
COVERED BIKE RACK
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
6' CEDAR FENCE TO BE INSTALLED DIRECTLY ADJACENT TO PROPERTY LINE
SAW CUT LINE, TYP
6'{PRK}5'{BIKE}
PER STD 104.3SEE DT-04
\A1;10'
SDESMT
EXISTING CULVERT TO BE REMOVED
\A1;15.3'\A1;15.6'N=166929.86
E=1302734.43
N=166701.26
E=1302727.41
N=166859.58
E=1302732.27
N=166850.23
E=1303031.98
E=1303034.10
STORM DETENTIOM CLEAN OUT
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
YARD DRAIN
3'X6' WATER ESMT
30'EX R/W60'EX R/WSE 172ND STPER STD 104.3SEE DT-04
\A1;20'\A1;30'N=166711.06
E=1303027.78
30'EX R/W
661.35'(P)
661.23'(R2)
108TH AVE SE
106TH AVE SE
\A1;15.3'
\A1;39'
\A1;20.5'
N=166920.54
\A1;16'\A1;10'GASESMT\A1;8'8'PVMT\A1;18'\A1;10'
SDESMT
EXISTING LIGHT POLE TO BE REMOVED AND REPLACED\A1;20' SD ESMTEXISTING LIGHT POLE TO BE REMOVED AND REPLACED
STOP SIGN
\A1;20' CITY
EMERGENCYACCESS ESMT
AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396205
TESC PLAN
1"=20'
ER-01
234IE=401.50
IE=401.50
40 LF 12" SD @ 15.0%%%
25 LF 12" SD @ 9.1%%%
63 LF 12" SD @ 9.5%%%
IE=395.50
CLEARING LIMITS
TESC POND, STD PLAN 216.00, ER-02
CLEARING AREA
PROTECTED AREA
SILT FENCE, STD. PLAN 214.00, ER-02
ROCK CONSTRUCTION ENTRANCE1
PRE DEVELOPMENT DRAINAGE PATTERN
RIP RAP PAD
INSTALL CHECK DAM EVERY 100' OR 2' OF ELEVATION CHANGE, STD. PLAN 217.40, ER-03
CONVEYANCE SWALE
LEGEND
SCALE: 1" =
0
20'
20'20'40'
POST DEVELOPMENT DRAINAGE PATTERN
1
TBR
TBR
TBR
1. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALLSCHEDULE AND ATTEND A PRE-CONSTRUCTION CONFERENCE WITH THE CITYOF RENTON STAFF. CESCL SHALL ATTEND CONFERENCE.2. FLAG CLEARING LIMITS.3. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR.4. INSTALL CATCH BASIN PROTECTION ONSITE AND WITHIN 500'DOWNSTREAM OF SUBJECT PROPERTY.5. GRADE AND INSTALL ROCK CONSTRUCTION ENTRANCE.6. INSTALL FILTER FABRIC FENCE AND CONSTRUCTION FENCE AS SHOWN.7. CONSTRUCT SEDIMENT TRAP AND OUTFALL.8. GRADE AND STABILIZE CONSTRUCTION ROADS.9. CONSTRUCT SURFACE WATER CONTROLS (CONVEYANCE SWALES, CHECKDAMS AND TEMPORARY CULVERTS) SIMULTANEOUSLY WITH CLEARING ANDGRADING FOR PROJECT DEVELOPMENT.10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OFRENTON STANDARDS AND MANUFACTURER'S RECOMMENDATIONS.11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURESSO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENTCONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY ESC MINIMUMREQUIREMENTS.12. COVER ALL AREAS WITHIN THE SPECIFIED TIME FRAME WITH STRAW,WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, CRUSHED ROCK OREQUIVALENT.13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS.14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30DAYS.15. CLEAN OUT STORM SYSTEM INCLUDING SEDIMENT TRAP ANDSTRUCTURES WHEN CONSTRUCTION IS COMPLETE AND SITE HAS STABILIZED.16. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BESTABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE.CONSTRUCTION SEQUENCETBR TO BE REMOVED
TEMPORARY STOCK PILE
IE=395.50
IE=391.23
CATCH BASIN PROTECTION, STD PLAN 216.30, ER-03
TBRTBRTBR
\pxqc;6' TALL CHAINLINK PROTECTIVE FENCE (5' BEYOND DRIP LINE)
TBR
TBRAS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396206
TESC NOTES AND DETAILS
AS NOTED
ER-02
235EROSION CONTROL NOTES
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITYOCCURS, A PRECONSTRUCTION MEETING MUST BE HELDWITH THE CITY OF RENTON, PUBLIC WORKS DESIGNENGINEER.2. ALL LIMITS OF CLEARING AND AREAS OF VEGETATIONPRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BECLEARLY FLAGGED IN THE FIELD AND OBSERVED DURINGCONSTRUCTION.3. ALL REQUIRED SEDIMENTATION/EROSION CONTROLFACILITIES MUST BE CONSTRUCTED AND IN OPERATIONPRIOR TO LAND CLEARING AND/OR CONSTRUCTION TOENSURE THAT SEDIMENT LADEN WATER DOES NOT ENTERTHE NATURAL DRAINAGE SYSTEM. ALL EROSION ANDSEDIMENT FACILITIES SHALL BE MAINTAINED IN ASATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARINGAND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FORON-SITE EROSION HAS PASSED. THE IMPLEMENTATION,MAINTENANCE, REPLACEMENT AND ADDITIONS TOEROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THERESPONSIBILITY OF THE PERMITTEE.
4. THE EROSION AND SEDIMENTATION CONTROL SYSTEMSDEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUMREQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. ASCONSTRUCTION PROGRESSES AND UNEXPECTED ORSEASONAL CONDITIONS DICTATE, THE PERMITTEE SHALLANTICIPATE THAT MORE EROSION AND SEDIMENTATIONCONTROL FACILITIES WILL BE NECESSARY TO ENSURECOMPLETE SILTATION CONTROL ON THE PROPOSED SITE.DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THEOBLIGATION AND RESPONSIBILITY OF THE PERMITTEE TOADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BYTHE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES,OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BENEEDED, TO PROTECT ADJACENT PROPERTIES AND WATERQUALITY OF THE RECEIVING DRAINAGE SYSTEM.5. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATIONCONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OFSTORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES,RESTRICTORS, CHANNELS, OR RETENTION FACILITIES.6. DURING THE TIME PERIOD OF OCTOBER 1ST THROUGHAPRIL 30TH, ALL PROJECT DISTRIBUTED SOIL AREASGREATER THAN 5,000 SQUARE FEET, THAT ARE TO BE LEFTUN-WORKED FOR MORE THAN 12 HOURS, SHALL BE COVEREDBY MULCH, SODDING OR PLASTIC COVERING.7. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATIONAND WHERE NO FURTHER WORK IS ANTICIPATED FOR APERIOD 30 DAYS OR MORE, ALL DISTURBED AREAS MUST BEIMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTINGOR OTHER APPROVED EROSION CONTROL TREATMENTAPPLICABLE TO THE TIME OF YEAR. GRASS SEEDING ALONEWILL BE ACCEPTABLE ONLY DURING THE MONTHS OF APRILTHROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED,HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE
PERMITTEE, BUT MUST BE AUGMENTED WITH MULCHING,NETTING OR OTHER TREATMENT APPROVED BY THE CITY OFRENTON, OUTSIDE THE SPECIFIED TIME PERIOD.8. FOR ALL EROSION/SEDIMENTATION CONTROL PONDSWHERE THE DEAD STORAGE DEPTH EXCEEDS 6 INCHES, AFENCE IS REQUIRED WITH A MINIMUM HEIGHT OF THREE (3)FEET, 3:1 SIDE SLOPES.9. A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE, 24FEET X 50 FEET X 8 INCHES OF 4 TO 6 INCH QUARRY SPALLS
393.50
396.00
3:1
784 SF
397.00
16 SF
393.00
OUTLET INVERT ELEV.
OVERFLOW ELEV.
SIDE SLOPES
TOP AREA (SF)
TOP ELEVATION
BOTTOM AREA (SF)
BOTTOM ELEVATION
TESC SEDIMENTATION POND
393.50ORIFICE INVERT ELEV.
1 1/8"%%CORIFICE SIZE
3.5' MIN.
NOTE:
\pxa0.5,t3;FOR POND, ORIFICE, EMERGENCY OVERFLOW SIZING SEE SWPPP APPENDIX A.AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18R-396207
TESC NOTES AND DETAILS
AS NOTED
ER-03
236AS-BUILT DRAWINGS
EARTHWORK QUANTITIES
CUT:
FILL:
DISTURBED/CLEARING AREA:
7,466 CY (10,500 TONS)
4,991 CY (7,000 TONS)
87,170 SF (2.00 AC)
NET:2,2475 CY FILL/IMPORT (3,500 TONS)
*NOTE:NET EARTHWORK VOLUME ESTIMATE ASSUMES 50%%% OF EXCAVATED
SOILS WILL BE UNSUITABLE FOR SITE BACKFILL USE.
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18T
B409.1402.0
7.1\A1;24'\A1;20'\A1;8'
\A1;8'
\A1;30' EX R/W
SCALE: 1" =
0
20'
20'20'40'
15.5' R/W DEDICATION
LEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
ROOFLINE
STORM DETENTIOM CLEAN OUT
PERVIOUS PAVEMENT
22'PVMT \A1;22.2'
\A1;PVMT30'EX R/W
\A1;30'
R-396208GRADING PLAN1"=20'
GR-01
2370.5%0.8%
0.5%0.5%0.8%
0.5%
0.6%1.0%1.0%
1.0%
1.0%0.9%0.5%
0.6%0.6%0.6%%%
410.44410.50410.45
410.502.93%
2.75%
2.5%0.75%
3.1%
2.0%
1.8%
2.7%2.0%1.0%3.0%3.0%1.9%2.0%0.5%0.5%1.0%1.0%1.5%
2.5%
1.0%6.4%1.0%5.9%%%10' LANDSCAPE BUFFER
20' CITY EMERGENCY ACCESS ESMT 0.5%%%0.5%0.5%%%
2.0%
NOTE
1. SEE SHEET GR-02 FOR ADDITIONAL DETAILED GRADING.2. SEE APPROVED BUILDING PERMIT B17004403 FOR CONSTRUCTIONDETAILS FOR RETAINING WALLS.
3. THE RETAINING WALL ADJACENT TO COTTAGE D WILL NOT CUASE ATRAFFIC VISION HAZARD FOR DRIVERS EXITINGONTO SE 172ND STREETBECAUSE THE FACE OF THE RETAINING WALL IS SET BACK 33 FEET FROMTHE FACE OF CURB NEAR THE EXIT. THE WALL WILL NOT OBSTRUCT ANYPORTION OF THE DRIVER'S VIEW OF SE 172ND AS THE VEHICLE.
1.0%%%12.2%%%FUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT
15'x12' POWER ESMT.1.0%%%10' LANDSCAPE BUFFER
T B
410.1405.34.8T
B
410.0
407.9 2.1
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER5.2%%%T
B 408.2404.6
3.6T
B
406.1402.1 4
T
B
404.7
401.1 3.6
4.5' R/W DEDICATION
T
B409.0
407.2
1.8
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
YARD DRAIN
EXISTING CULVERT TO BE REMOVED
LIMITS OFFUTURERESTORATION BY"AVANA RIDGE"
LIMITS OF FUTURE RESTORATION BY"AVANA RIDGE"16+45.93, 18.00'
10' LANDSCAPE BUFFER T
B
410.1409.01.13'X6' WATER ESMT
\A1;18'\A1;PVMT30'EX R/W\A1;1'\A1;30'\A1;26'\A1;PVMT\A1;10'
SDESMT \A1;10'GASESMT\A1;20' CITYEMERGENCYACCESS ESMT\A1;10'
SDESMT
T
B410.1403.5
6.6
T
B409.1402.6
6.5T
B409.1402.3
6.8
T
B409.1402.7
6.4
T
B
409.1403.1 6
T
B
410.1405.0 5.1
AA
\A1;57'
\A1;UTILITY ESMT
T
B409.1403.35.8
B
B
T
B
410.1403.36.8CONNECT DRAIN LINE TO CONTROL STRUCTURE \A1;20' SD ESMT16'WATER &SEWER ESMT 410.46SPOT ELEVATIONS WERE NOT AS-BUILTAS-BUILT NOTEAB
AB
AB
AB
AB
ABAB
AB
AB
ABABAB
AB
AB
AB
AB
AS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,28510 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-18SCALE: 1" =
0
10'
10'10'20'
R-396209
DETAILED GRADING PLAN
AS NOTED
GR-02
2381.0%4.89%1.5%0.6%1.0%1.0%1.0%5.0%
1.5%5.2%
3.3%
7.7%1.0%1.0%2.0%2.0%4.0%1.0%1.0%4.5%1.5%1.0%2.0%4.0%
6.7%%%
6.9%%%
2.9%
4.4%
SCALE: 1"=10'SE 172ND ST AND 108TH AVE SESCALE: 1"=10'SE 172ND ST AND DRIVE ADRIVE A
108TH AVE SE
SE 172ND STCURB RETURN #1
%%130=86°24'36"
R=30.0'
L=45.24'
A
B0+0010+0017+00
19+00
20+00
NOTES
\pxi-2,l2,t2;1. SEE RENTON STANDARD PLANS FOR DRIVEWAY STANDARDS COR STD PLAN 104.3 TYPE R1B
2
GB
1
2
2
2
2
1
1 2
GB
GB
GB
GB
GB
B
A
KEY MAP
NOT TO SCALE ADA RAMP NOTES1
2
CURB RETURN #2
%%130=99°59'58"
R=30.0'
L=52.36'
1
1.4%%%
6.4%%%1.4%%%1
4.5%
2 STA 19+42.4 8.0' RTSTA 19+70.5 44.2' RT
C
A B
D DRIVE A5.0%%%1.5%%%4.9%
6.4%%%6.5%%%0.8%1.5%%%5.0%4.0%0.8%%%0.7%%%3.0%1.92%1.5%5.0%1.5%1.5%2.0%4.10%
3.0%
5.74%1.5%6.25%2
2
4.8%%%
5.2%%%
1.5%%%4.8%%%1.7%%%1.7%%%STA 10+44.83 22.00' LT
STA 19+50.9 18.00' LTSCALE: 1"=10'C
108TH AVE SE
DRIVE A
C
SE 172ND ST108TH AVE SE
SE 172ND STTOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
6.9%%%
2.5%%%7.0%%%1.4%%%0.7%%%
4.4%
2.6%%%7.5%%%7.5%%%1.3%%%1.3%%%5.4%%%7.5%1.5%\A1;5.41\A1;5.07
\A1;7.54\A1;5.3\A1;4\A1;15.39\A1;6.14 SPOT ELEVATIONS WERE NOT AS-BUILTAS-BUILT DRAWINGS
NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON
DATE:
FIELDBOOK:
DRAWING NO:
PAGE:
SHEET: OF:
SCALE:
DESIGNED:
DRAWN:
CHECKED:
APPROVED:NO.REVISION BY DATE APPR
SURVEYED:
VERTICAL: NAVD 1988
IF NOT ONE INCH
ONE INCHAT FULL SCALE
HORIZONTAL: NAD 1983/1991
SCALE ACCORDINGLY DATUMPlanning/Building/Public Works Dept.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
Surveying
Engineering
Pl anning
ANN I VE RS ARYth15
NC
MEV
MEV
MEV
LDC
RENTON SPECIAL CARE COMMUNITY
RENTON SPECIAL CARE COMMUNITY, LLC
RENTON SPECIAL CARE - 16-137
04-08-17 ΟΘ9 06,////46ΚΤ≅9 06,////12Β906//1572Θ∆ΜΣΝΜ ΡΟ∆ΒΗ≅Κ Β≅Θ∆Σ∆Χ,3/,2851TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER.
TOPOGRAPHIC DISCLAIMER
0 AS-BUILT DRAWINGS MEV 12-13-18KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
KCOWLLIVE.KRAM
REENIGNELANOISSEFORP
DERETSIGER
NOTGNIHSAWFOETATS
40908
12-13-1829 LF 8" PVC @ 4.83%%%
71 LF 8" PVC @ 2.50%%%
200 LF 12" PVC @ 1.78%%%
\A1;15'
\A1;27.7'\A1;24'\A1;DRIVE AISLE\A1;24'\A1;DRIVE AISLELEGEND
SEWER PIPE
WATER PIPE
STORM PIPE
DRAIN PIPE
SCALE: 1" =
0
20'
20'20'40'
2'
ROOFLINE
NOTES
1. ALL ROOF DRAIN PIPE IS 6"%%C AT 2.0% MIN SLOPE UNLESS OTHERWISESPECIFIED.2. SEE SHEET RD-02-RD-06 FOR ROAD AND STORM DRAINAGE PROFILES.3. SEE SHEET SD-01 FOR STORM DRAINAGE DETENTION PIPE DETAILS.
22'PVMT \A1;22.7'
\A1;PVMT30'R/W
\A1;30'\A1;30'R-396210
ROAD AND STORM DRAINAGE PLAN
1"=20'
RD-01
230/CB-A17
CB-A16
EX-CB
\A1;30'\A1;35'\A1;35'
\A1;23'\A1;23'\A1;23'ZERO HEIGHT CONCRETE CURB FROMSTA 3+53 - STA 4+63SEE DT-03
CONCRETE VALLEY GUTTERFROM STA 2+44 -STA 3+53. SEE DT-03
#UTILITY CROSSING
PIPE CROSSING TABLE8" PVC PIPE BOTTOM=400.88
12" SS TOP=399.01
8" PVC PIPE BOTTOM=403.75
8" WATER TOP=402.25
STA 1+23.22, 22.00' RT. (DRIVE A)
1
2
PIPE SEPARATION=1.87'
STA 1+23.22, 30.40' RT. (DRIVE A)
PIPE SEPARATION=1.50'
2
1
RIM=410.35
IE=408.25
RIM=410.30
IE=403.68
RIM=410.40
IE=404.14
RIM=410.30
IE=404.74
RIM=410.32
IE=407.46
RIM=410.37
IE=405.22
RIM=408.0
IE=405.50
FILTERRA 10'X6' ENHANCED WATER QUALITY TREATMENT VAULT
30'R/W
470 LF 8'%%C STORMWATER DETENTION TANK SEE SHEET SD-01 FOR ADDITIONAL DETAILS
CB-4,TYPE-1
STA. 1+23.22, 9.22' LT
CB-5,CONCRETE INLET
STA. 2+07.40, 16.19' LT
CB-6,CONCRETE INLET
STA. 2+43.92, 9.25' RT CB-7,TYPE 1
STA. 3+52.81, 9.25' RT
CB-2 TYPE-2
CONTROL STRUCTURE
STA. 0+73.24, 1.57' LT
CB-1,TYPE-2-48"
STA. 0+16.76, 5.95' LT
CB-16,TYPE-2-48"
STA. 16+60.71, 2.69' LT
36 LF 6" PVC @ 8.97%%%
CB-10,TYPE-2-48"
W/ SOLID LOCKING LID
STA. 1+33.23, 18.50' RT
CB-3,TYPE-1
W/ SOLID LOCKING LID
STA. 0+73.29, 13.59' LT
CB-8,TYPE-2-48"
W/ SOLID LOCKING LID
STA. 1+23.22, 41.27' RT \A1;20' CITYEMERGENCYACCESS ESMTFUTURE PAVEMENT AND ROAD WORK BY "AVANA RIDGE" DEVELOPMENT
92 LF 8" PVC @ 2.09%%%
15'x12' POWER ESMT.
SEE PERVIOUS PAVEMENT DETAIL DT-01
SEE PERVIOUS PAVEMENT DETAIL DT-01\A1;25'10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
12" PVC PIPE=391.64
8" SS TOP=389.22
3 STA 16+98.98, 17.11' LT. (SE 172ND ST)
PIPE SEPARATION=2.42'
CB-6-A,CONCRETE INLET
STA. 3+15.79, 7.34' RT
CB-1-A,TYPE 1
STA. 17+95.95, 17.22' LT
3
37 LF 8" PVC @ 2.50%%%
8" PVC PIPE=400.52
8' DETENTION PIPE TOP=399.00
4
STA 1+23.22, 1.48' LT. (DRIVE A)
PIPE SEPARATION=1.52'
8" PVC PIPE=402.42
8' DETENTION PIPE TOP=399.00
5 STA 2+10.17, 10.21' LT. (DRIVE A)
PIPE SEPARATION=3.42'
4
5
CB-11,TYPE-1
STA. 10+47.04, 21.20' LT
95 LF 12" PVC @ 0.47%%%
CB-12,TYPE-1
STA. 10+47.04, 46.26' LT
111 LF 12" PVC @ 5.29%%%
EXISTING CULVERT TO BE REMOVED
12 LF 8" PVC @ 2.00%%%
44 LF 8" PVC @ 2.00%%%
STORM DETENTIOM CLEAN OUT
PERVIOUS PAVEMENT
PROPOSED ASPHALT
PROPOSED GRIND/OVERLAY
YARD DRAIN
DOWNSPOUT
RAISE TO FINISH GRADE
108TH AVE SE
\A1;26'\A1;30'SE 172ND ST3'X6' WATER ESMT
134 LF 12" PVC @ 1.98%%%
25 LF 12" PVC @ 0.47%%%
50 LF 8" PVC @ 2.00%%%
12 LF 8" PVC @ 6.00%%%
10' LANDSCAPE BUFFER
10' LANDSCAPE BUFFER
CB-13,TYPE-2-48"%%C
STA. 11+42.04, 46.87' LT
30 LF 12" PVC @ 0.60%%%COTTAGE BCOTTAGE A\A1;10'
SDESMT\A1;10'GASESMTCB-9,TYPE-1
W/ SOLID LOCKING LID
STA. 11+05.62, 68.11' LT
COTTAGE CCOTTAGE DCB-14,TYPE-2-48"%%c
W/ SOLID LOCKING LID
STA. 11+71.75, 42.70' LT
CB-15,TYPE-2-48"%%c
W/ SOLID LOCKING LID
STA. 4+12.76, 7.40' RT
72 LF 12" PVC @ 0.50%%%\A1;20'\A1;SD ESMT60 LF 8" PVC @ 0.56%%%
57'UTILITY ESMT
RETAINING WALL DRAIN LINE
STOP SIGN
\A1;20'
\A1;DRIVE AISLE
SEE PAVEMENT SECTIONON SHEET RD-07
\A1;9'\A1;10'
SDESMT
STA. 11+43.01, 47.61' LT
STA. 3+15.83, 7.36' RT
STA. 0+73.64, 1.88' LT
STA. 0+73.32, 13.40' LT
STA. 1+22.75, 9.43' LT
STA. 2+06.59, 16.74' LT
STA. 16+60.08, 9.23' LT
STA. 17+96.77, 16.93' LT
STA. 10+46.85, 46.12' LT
STA. 11+05.93, 67.66' LT
STA. 11+71.49, 41.77' LT
STA. 4+14.03, 8.14' RT
STA. 3+52.74, 9.21' RT
STA. 2+43.95, 9.54' RT
STA. 1+31.38, 20.56' RT
STA. 1+24.10, 41.27' RT
STA. 10+43.59, 21.23' LT
25 LF 12" PVC @ 1.28%%%
96 LF 12" PVC @ 0.52%%%
200 LF 12" PVC @ 1.64%%%
29 LF 12" PVC @ 0.83%%%
72 LF 12" PVC @ 0.58%%%
61 LF 8" PVC @ 0.59%%%35 LF 8" PVC @ 2.80%%%45 LF 8" PVC @ 1.94%%%
73 LF 8" PVC @ 2.23%%%91 LF 8" PVC @ 2.17%%%
11 LF 8" PVC @ 1.50%%%
28 LF 8" PVC @ 1.80%%%
12 LF 8" PVC @ 31.96%%%
56 LF 12" PVC @ 2.07%%%
STA. 16+86.26, 17.86' LT
57 LF 12" PVC @ 1.37%%%
136 LF 12" PVC @ 1.92%%%
51 LF 8" PVC @ 2.33%%%
111 LF 12" PVC @ 5.12%%%
12 LF 12" PVC @ 0.51%%%
12 LF 12" PVC @ 1.00%%%AS-BUILT DRAWINGSthere was a n
approved revision to
replace this with a
concrete inlet per
std plan 200.30. was
this changed?
15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50388.0389.6390.9393.1394.5395.8396.6397.8398.9400.0400.6401.9403.1403.7404.5405.3406.3407.6409.8415.8SE 172ND STSCALE:HOR:
VER:
1"=20'
1"=10'
RIM=
IE=388.06STA. 15+51.14, 16.25' LT.
CB-A16,TYPE 2-60"
W/ SOLID LOCKING LID
IE=388.06 (12"%%C) E
RIM=395.96
STA. 16+60.71, 2.69' RT.
EX CB,TYPE 2-48"
W/ SOLID LOCKING LID
IE=390.84
IE=390.84 (12"%%C) SCB-A17,TYPE 2-48"
RIM=
IE=388.17
STA. 15+58.37, %%132
W/ SOLID LOCKING LID 12 L.F. 12" PVC @ 1.00%%%
RIM=396.22
STA. 16+60.71, 11.19' RT.
CB-16,TYPE 2-48"
CURB INLET, SEE DT-01
IE=390.96 (12"%%C) N
AVANA RIDGE PROPOSED
AVANA RIDGE PROPOSED
RIM=397.74
IE=390.72 (12"%%C) W,E,N
CB-1,TYPE 2-48"
STA. 16+85.07, 17.09' RT.
W/ OPEN GRATE
EXISTING GRADEAT ROAD %%132 PVI EL=410.00PVI STA=19+78.00PVI EL=408.01PVI STA=19+40.005.24%
6.41%
20+00
360
380
400
420
340INTERSECTION, ROAD %%132STA 0+00.00, DRIVE AEL=398.04STA 20+00.00, SE 172ND ST=INTERSECTION, ROAD %%132STA 10+00.00, 108TH AVE SEEL=411.41FG RIM=396.55
{\C251;391.20}*
(12"