Loading...
HomeMy WebLinkAboutP_Existing_and_Proposed_Floor_Plans_190401_v1PLAN LEGENDNEW CONSTRUCTIONEXISTING WALL TO REMAINEXISTING WALLS AND WINDOWS TO BE REMOVED AND/OR MODIFIEDD-#NEW DOOREXISTING DOOREXISTING DOOR TO BE REMOVED AND/OR MODIFIEDGENERAL NOTES-VERIFY IN THE FIELD ALL DIMENSIONS OF EXISTING CONDITION-CONSTRUCTION TO COMPLY WITH THE 2015 IRC-2X6 EXTERIOR STUD WALLS @ 24" O.C. STACKED FRAMED-2X4 INTERIOR STUD WALLS @ 24" O.C. UNLESS NOTED OTHERWISE-BEARING AND HEADERS TO BE 6X8 #2 DF OR 4X10 #2 DF FURRED-OUT-FIREBLOCK ALL PLUMBING PENETRATIONS-ALL HANGER TO BE SIMPSON OR EQUAL-BEDROOMS TO HAVE AT LEAST ONE OPERABLE WINDOW NET CLEAR OPENING OF 5.7 SQ. FT. MIN. WITH A NET CLEAR OPENING HT. OF 24" MIN. AND NET CLEAR OPENING WIDTH OF 20" MIN. AND A FINISHED SILL HEIGHT OF NOT MORE THAN 44" ABOVE FINISH FLOOR.-ALL LUMBER EXPOSED TO WEATHER OR CONCRETE TO BE PRESSURE TREATED OR CEDAR SQUARE FOOTAGEEXISTING1ST FLOOR0LIVING AREAGARAGESTORAGETOTAL493164657NOTE:THE CONSTRUCTION DOCUMENTS REPRESENTED HEREIN ARE BASED ON NON-INVASIVE SITE OBSERVATION OF THE EXISTING STRUCTURAL CONDITIONS OF THE PROPOSED PROJECT. AS A RESULT, IN CERTAIN INSTANCES, DESIGN ASSUMPTIONS WERE USED TO FORMULATE THE COMPATIBILITY OF THE NEW CONSTRUCTION WITH THE EXISTING STRUCTURAL ELEMENTS. DURING THE COURSE OF CONSTRUCTION, IT IS POSSIBLE THAT CONDITIONS MAY BE ENCOUNTERED THAT DO NOT COINCIDE WITH THE DESIGN ASSUMPTIONS AND MAY REQUIRE FURTHER STRUCTURAL REVIEW TO DETERMINE ADEQUACY. THE BUILDER SHALL BE OBSERVANT OF THESE CONDITIONS AND IMMEDIATELY REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING FURTHER WITH THE WORK. 4' - 0 1/2"5' - 2"5' - 0"5' - 2"19' - 4 1/2"3' - 11"6' - 0"3' - 3"3"1' - 9"2' - 0"4' - 0"2' - 0"2' - 5"7' - 7"2' - 6"1 1/2"4' - 0"1' - 3 1/2"1' - 3"2' - 6"2' - 11"3' - 9"2' - 0"4"2' - 6"3' - 5"3' - 0"3' - 7"7' - 0 1/2"8' - 4"3' - 0"1' - 0"33' - 2"KITCHEN4-0X3-6 REF.DWCOOKTOP & HOODLIVING ROOM2-0X2-0 6-0X5-0 D-01D-02D-03D-04D-07D-065-0X5-0 4-0X5-0 BEDROOM 1BEDROOM 2SINK9' - 2"5' - 5"8' - 7"10' - 0"13' - 2"10' - 0"10' - 0"5' - 0"4' - 4"1' - 0"5' - 0"BATHD-05LAUNDRYCLOSETCLOSETCOSDSDVTOS 50 CFMVTOS 100 CFMVTOS 50 CFMPROPOSED657LIVING AREAGARAGESTORAGETOTAL006571A-61A-6OCCUPANCY AND TYPE OF CONSTRUCTIONR-3TYPE V-BOCCUPANCY GROUPTYPE OF CONSTRUCTIONDOOR NUMBERTYPESIZEWIDTHHEIGHTD-01SWING / SINGLE / PANEL3'-0"6'-8"D-022'-4"6'-8"MATERIALWOODWOODDETAILHEADJAMB4/A-55/A-5DOOR SCHEDULE4/A-45/A-4D-032'-6"6'-8"WOOD4/A-45/A-4D-044'-0"6'-8"WOOD6/A-47/A-4D-052'-6"6'-8"WOODD-062'-4"6'-8"WOOD4/A-45/A-4D-076'-8"WOODSWING / SINGLE / PANELSWING / SINGLE / PANELSLIDING / DOUBLE / PANELSWING / SINGLE / PANELSWING / SINGLE / PANEL4/A-45/A-44'-0"6/A-47/A-4SLIDING / DOUBLE / PANEL4' - 0 1/2"15' - 4"19' - 4 1/2"6' - 1"3' - 10"3' - 6"3' - 10"5' - 11"10' - 0"2' - 6"3' - 0"2' - 5"3' - 10"5' - 1"3' - 10"2' - 6"3' - 5"3' - 0"3' - 7"7' - 0 1/2"10' - 0"2' - 4"3' - 7"2' - 7"2' - 3"33' - 2"GARAGESTORAGEEXISTING SLAB ON GRADESLOPE TO DRAINFROM NW CORNER TO SE CORNERELEVATION CHANGES 2"NW CORNER EL. @ 411'-8"SE CORNER EL. @ 411'-6"EXISTING GARAGE DOORTO BE REMOVEDEL. 411'-8" EL. 411'-6" SLOPE TO DRAINDRAWN BY:PROJ. NO.:DATE:PROJ. ARCH.:DWG.DWG.EDCBA4321OWNER:ISSUEMARK DATE DESCRIPTIONEDCBA4321ARCHITECT:STRUCTURAL ENGINEER:3/30/2019 8:19:00 PMC:\Users\sjoo\Documents\RevitLocalFiles\Renton_sjoo.rvt00001.0012/17/2016EXISTING ANDPROPOSEDFLOOR PLANSA-4JUNGRESIDENCECHANGE OFUSESteve Joosteve.joo@hotmail.com206-306-6738SUNG JUNGoh0420@hotmail.com206-384-08504706 NE 18TH STRENTON WA 980592019 02 25 1/4" = 1'-0"2PROPOSED FLOOR PLAN 1/4" = 1'-0"1EXISTING FLOOR PLAN