HomeMy WebLinkAboutP_Civil_Utility_190419_v1.pdfEAST VALLEY ROADS.R. 167WALKER MAZDA DEALERSHIP FIRE HYDRANT FIRE HYDRANT FIRE HYDRANT FIRE HYDRANT OIL/WATER SEPARATOR CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S WALKER MAZDA DEALERSHIP PRICING SET AHBL JOB #2180100.11 27 Know what's below. before you dig.Call RTED-XX-XXXXC:XXXXXXXXLUA:18-000305PR:18000212R-XXXXX NPDES PERMIT# WAR306639 COMPOSITE UTILITY PLAN C6.1 27 1.ALL SEWER, WATER, STORM DRAINAGE, AND GAS SHALL BE MARKED WHERE THEY INTERSECT THE CURB WITH METAL TAGS EMBEDDED IN THE FACE. REFER TO SECTION 3.08 OF THE CITY DEVELOPMENT GUIDELINES AND PUBLIC WORKS STANDARDS. COORDINATE WITH CITY INSPECTOR. 2.MAINTAIN 18" VERTICAL SEPARATION AT ALL WATER UTILITY CROSSINGS 3.UTILITIES PARALLEL TO WATER SHALL MAINTAIN A MINIMUM 10' HORIZONTAL SEPARATION. NON-WATER UTILITIES PARALLEL TO EACH OTHER SHALL MAINTAIN A MINIMUM 1' HORIZONTAL SEPARATION. UTILITY NOTES UTILITY LEGEND PROPERTY BOUNDARY ROAD CENTERLINE RIGHT OF WAY BOUNDARY SIDEWALK PAVING EXISTING TREE EXISTING POWER PROPOSED POWER EXISTING GAS LINE EXISTING COMMUNICATION LINE EXISTING WATER LINE PROPOSED WATER LINE WATER TEE WATER BEND FIRE HYDRANT THRUST BLOCK GATE VALVE WATER METER EXISTING SEWER LINE PROPOSED SEWER LINE SEWER CLEANOUT PROPOSED STORM DRAIN PROPOSED ROOF DRAIN STORM DRAIN CLEANOUT CATCH BASIN STORM MANHOLE N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 RECEIVED 04/23/2019 amorganroth PLANNING DIVISION