HomeMy WebLinkAbout20090908_DQInspector's Daily Report
Project Name Date Shift
Sheet 1 of 3 day
Weather
AM PM
Inspector IDR Report #
No.No.
11
6
4
2
1
1 650J John Deere Dozer
1
2
1
Photos/Videos taken today?x Yes No File:
Inspector's Shift Hours
From:
To:Inspector's Signature
Reviewed By
Laborer with CTI
September 8, 2009
September 8, 2009
Daniel Quehl
7:00 PM
TR (9/10/09)
Acceptable
Date
6:00 AM
Date
EX 450 Hitachi Excavators
Location Structure#/Station
Bid Items Inspected Today/Field Note
Flaggers
partly cloudy, hi 76 low 71
Daniel Quehl 20090908 DQ
General Foreman with CDB Foreman with CTI
Operators with CTI
350P John Deere offroad dump trucks(idle)
D6 Cat Dozer
Dynapac 16 ton vibratory roller
IDR Sheet
Item Number Material / Item Description
Major Equipment on Project
CDB Number & Classification
EX 270LC Hitachi Excavator with hoepack
Subcontractor Number & Classification
Plan SheetItem Quanity
I-405/I-5 to SR169 Stage 2 - Widening
and SR515 Interchange Project
partly cloudy, hi 71 low 57
Traffic Control
ReviewedSignsBarricades
Inspector's Daily Report
Project Number
Sheet 2 of 3
Inspector IDR Report #
IDR Sheet
Daniel Quehl
I-405/I-5 to SR169 Stage 2 - Widening
and SR515 Interchange Project
Inspector's Notes
September 8, 2009
Date
20090908 DQ
Attended the CDB morning meeting at 6:30 am
Today's activities for CDB at the Defoor site:
Performed observation and soil density testing for common borrow fill at the Defoor site along Cedar Road from
stations 10+00 to 13+00 for the conveyor belt extension and geogrid reinforcing bench from stations 10+35 to
11+50.
Performed soil density testing at above locations using a Troxler nuclear density gauge model 3440. A
maximum dry density of 116.9 pcf at 12.8% optimum moisture was used per Mayes Testing lab number T09082-
21. The tests met the required 95% compaction. The contractor was informed of test results. See attached
Field Density Report for results and locations.
This common borrow used was being transported by a conveyor belt from the Rolling Hills south of Thunder
Creek.
The samples obtained from these nuclear density tests were done per Method 1 SOP 615 and the percent
compaction determined per SOP 615. See the attached Density Worksheets.
Spoke with Mike Ross with CDB and approximately 3,916 cubic yards of material was placed from a total of 178
loads.
Visited by Roch Player,Engineer with CDB, Chad Webley, Field Engineer with CDB, and Bob Pyle,Compliance
Inspector with WSDOT, to see the progress made and the effect that the rain had on the site this past weekend.
Each noted how well the site held up to the rain and no problems were noticed.
Observed the finish cut of the compacted fill along the 2:1 slope where Geogrid was installed from
stations 11+75 to 15+95 and elevations 171 to 183.
Todays activities for CDB at the Benson Bulb Out site:
Observation and Soil Density testing at the Benson Bulb Out using the common borrow. Testing was performed
using the same equipment and proctor value stated earlier in my report. One test was performed meeting the
95% required compaction. The contractor was informed of test results. See attached Field Density Report and
Density Work Sheets for the results and location.
Personal present at the Benson Bulb Out:
1.foreman with CDB
2.(4) Operators with CDB
3. (3) Laborers with CDB
4. Flagger
Equipment usd at the Benson Bulb Out :
1. D9N CAT Dozer
2. EX300 Hitachi Excavator
3. EX 120 Hitachi Excavator
4 CS 683E Vib t R ll
Inspector's Daily Report
Project Number
Sheet 3 of 3
Inspector IDR Report #
Inspector's Notes
I-405/I-5 to SR169 Stage 2 - Widening
and SR515 Interchange Project September 8, 2009
Daniel Quehl
IDR Sheet Date
20090908 DQ
Personal used on the Defoor site:
1. Dan Lonsdale-General Foreman with CDB
2. Kevin Wicklund-Foreman with CTI
3.Mark Klinkhammer-Operator with CTI
4.Larry Bumper-Operator with CTI
5.Mark Furnier-Operator with CTI
6.Jay Knudtsen-Operator with CTI
7.Kim Bowen-Operator with CTI
8.Cody Z.-Operator with CTI
9.Leo Dunn-Laborer with CTI
10.Mike Forest-Laborer with CTI
11. Bill Smith-Laborer with CTI
12. Scott Henderson-Laborer with CTI
Equipment used on the Defoor site:
1.Two 350P John Deere offroad dump trucks (both idle)
2.Two EX450 Hitachi Excavators
3. EX270LC Hitachi Excavator with a Hoepack
4.D6 Cat Dozer
5.Dynapac 16 Ton Vibratory Roller
6.650J John Deere Dozer
Project #:Date: 9/8/2009
Project :20
Inspector: Test Method: WSDOT FOP for AASHTO T310
123
10+00 to 13+00 10+35 to 11+50 10+00 to 13+00
T09082-21 T09082-21 T09082-21
10+50 10+65 12+50
N/A N/A N/A
Common Common Common
-22 -9 -18
0 degrees 115.9 114.9 115
90 degrees 115.2 115.1 115.3
average 115.55 115 115.15
0 degrees 11.3 10.4 11.3
90 degrees 12.5 10.8 10.8
average 11.9 10.6 11.05
10.72 9.858 9.813
000
10.72 9.858 9.813
0.75 0.4655 0.433
000
0.75 0.4655 0.433
7.0 4.7 4.4
93 95 96
116.9 116.9 116.9
99 98 99
12.8 12.8 12.8
12.8 12.8 12.8
12.8 12.8 12.8
Thomas B Robinson
Test Hole Number
Soils Field Density Worksheet for WSDOT Projects (WSDOT SOP 615)
Moisture Density Curve #
Test Station
Station to Station
Worksheet used when Maximum Density is determined using WSDOT Method T606
Daniel Quehl
WSDOT I405,I5, to SR169 MTE Nuclear Gauge #:
Material Type
Depth of Material
Dry Density lbs/cu.ft.
Reviewed By:
Comments:
Optimum Moisture Content Corrected = ((6 x 7) + (5 x 8)) / 100
(6) % Passing #4 Sieve = (100 - % Retained)
Density and Optimum Moisture Determination WSDOT T606
Percent Compaction (% of maximum) = (Dry Density / Corrected Maximum Density) x 100
Maximum Density (from Maximum Density Curve Table)
(7) Optimum Moisture of Fine Material, passing #4 (from Maximum Density Curve Report)
(8) Optimum Moisture of Coarse Material, retained #4 (from Maximum Density Curve Report)
(1) Mass of Sample (Dry or SSD) + Tare
(2) Mass of Tare A
T09082
Gradation Determination
Average Moisture Content
Reference to Centerline
Moisture Content
Average Dry Density lb/cu.ft.
Gauge Readings
(5) % Retained on #4 Sieve (% Oversize) = Mass Retained / Mass of Sample
Mass of Sample (Dry or SSD) = (1) - (2)
(3) Mass of Retained on #4 Sieve + Tare
(4) Mass of Tare B
Mass of Material Retained on #4 Sieve = (3) - (4)
Project #:Date: 9/8/2009
Project :20
Inspector: Test Method: WSDOT FOP for AASHTO T310
45
10+35 to 11+50 Ctrl line 14382
T09082-21 T09082-21
10+50 15+38
N/A N/A
Common Common
-8 -12
0 degrees 114.4 115.8
90 degrees 113.9 115.7
average 114.15 115.75
0 degrees 9.2 10.1
90 degrees 9.9 10.1
average 9.6 10.1
10.139 10.198
00
10.139 10.198
0.4835 0.1055
00
0.4835 0.1055
4.8 1.0
95 99
116.9 116.9
98 99
12.8 12.8
12.8 12.8
12.8 12.8
Thomas B Robinson
(5) % Retained on #4 Sieve (% Oversize) = Mass Retained / Mass of Sample
Mass of Sample (Dry or SSD) = (1) - (2)
(3) Mass of Retained on #4 Sieve + Tare
(4) Mass of Tare B
Mass of Material Retained on #4 Sieve = (3) - (4)
(1) Mass of Sample (Dry or SSD) + Tare
(2) Mass of Tare A
T09082
Gradation Determination
Average Moisture Content
Reference to Centerline
Moisture Content
Average Dry Density lb/cu.ft.
Gauge Readings
Optimum Moisture Content Corrected = ((6 x 7) + (5 x 8)) / 100
(6) % Passing #4 Sieve = (100 - % Retained)
Density and Optimum Moisture Determination WSDOT T606
Percent Compaction (% of maximum) = (Dry Density / Corrected Maximum Density) x 100
Maximum Density (from Maximum Density Curve Table)
(7) Optimum Moisture of Fine Material, passing #4 (from Maximum Density Curve Report)
(8) Optimum Moisture of Coarse Material, retained #4 (from Maximum Density Curve Report)
Material Type
Depth of Material
Dry Density lbs/cu.ft.
Test Hole Number
Soils Field Density Worksheet for WSDOT Projects (WSDOT SOP 615)
Moisture Density Curve #
Test Station
Station to Station
Worksheet used when Maximum Density is determined using WSDOT Method T606
Daniel Quehl
WSDOT I405,I5, to SR169 MTE Nuclear Gauge #:
Reviewed By:
Comments:
Page ofDirect TransmissionDirect TransmissionProject:Inspector:115.9115.2114.9115.1OMC %12.8In our opinion, fill does not meet specifications as indicated by test numbers:Fill test meets compaction specificationsTan silty sand with trace of oversize113.999*Moisture %:SoilFIELD DENSITY TEST REPORTTan silty sand with trace of oversizeAverage9.2-8'below top benchTan silty sand with trace of oversize4aTan silty sand with trace of oversizeTan silty sand with trace of oversize11Date: 9/8/2009T09082WSDOT I405,I5 to SR169Dan QuehlProject No.:Tan silty sand with trace of oversizeType and Number of earth moving units:Dozer and ExcavatorASTM D 698 (Standard Proctor)ASTM D 1557 (Modified Proctor)Specification Compaction and Material :95%-T99128Direct Transmission12.8116.9116.9116.912.8Direct Transmission-8'below top benchFill for Conveyor Belt Extension 45' west of Cedar Road at station 10+50Fill for Geogrid Reinforcing Bench 120' east of ditchline at station 10+65Fill for Geogrid Reinforcing Bench 120' east of ditchline at station 10+65Fill for Conveyor Belt Extension 35' west of Cedar Road at station 12+50Direct TransmissionDirect Transmission*See Attached Density Work Sheet for test #'s 1 thru 5Type and Number of Compaction units:Number of Passes:16 ton vibe roller3to4Part-time observationDry Density: 9.9QC Sample:Test No.:Thickness of lift:Contractor AdvisedFull-time observationMethod of Adding Moisture:No moisture added today1 footComments:LocationIn our opinion, fill generally meets specifications as indicated by test numbers:Soil Type DescriptionTan silty sand with trace of oversizeTan silty sand with trace of oversizeTan silty sand with trace of oversizeFill for Geogrid Reinforcing Bench 130' east of ditchline at station 10+50Fill for Conveyor Belt Extension 45' west of Cedar Road at station 10+50Fill for Conveyor Belt Extension 35' west of Cedar Road at station 12+50-9'below top bench-9'below top bench-18'below finishgrde-18'below finishgrde4*124.9125.212.84aFill for Geogrid Reinforcing Bench 130' east of ditchline at station 10+50116.9114.49.923a2a3Test #11a20Tan silty sand with trace of oversize116.9MTE Nuclear Gauge No.:Wet Density (PCF)11.312.5ASTM D 693812.8Tan silty sand with trace of oversize9910.4116.912.8115.398Compaction %FieldMoisture Content %Dry Density (PCF)113.910.8Depth or Elevation (feet)Direct TransmissionDirect TransmissionBackscatter / Direct TransmissionLaboratoryMax Dry Density (PCF)-22'below finishgrde-22'below finishgrde116.9116.912.8*129129.5126.8127.810.8Average12.8*11.3127.5****115Average20225 Cedar Valley Road, Suite 110 Ph 425.742.9360 Lynnwood, WA 98036 Fax 425.745.1737 10029 S. Tacoma Way, Suite E-2 Ph 253.584.3720 Tacoma, WA 98499 Fax 253.584.3707 7911 NE 33rd Drive, Suite 190 Ph 503.281.7515 Portland, OR 97211 Fax 503.281.7579 MTE 1400-2C, Rev 2, 4/1/08
Page of5a115.7 Moisture %:SoilFIELD DENSITY TEST REPORTT09082WSDOT I405,!5 to SR 169Daniel QuehlProject No.:Project:Inspector:22Date: 9/8/2009Specification Compaction and Material :95%-T99Type and Number of earth moving units:Trackhoe and DozerASTM D 698 (Standard Proctor)ASTM D 1557 (Modified Proctor)Fill along slope at Benson Bulb Out 30' west of Benson Road 14382 control lineFill along slope at Benson Bulb Out 30' west of Benson Road 14382 control line*See Attached Density Work Sheets for tests #'s 1 thru 5Type and Number of Compaction units:Number of Passes: 16 ton vibratory roller3to 4Part-time observationDry Density: 10.1QC Sample:Test No.:Thickness of lift:Contractor AdvisedFull-time observationMethod of Adding Moisture:No moisture added today1 foot Comments:LocationIn our opinion, fill generally meets specifications as indicated by test numbers:Soil Type DescriptionTan silty sand with trace of oversizeTan silty sand with trace of oversizeTan silty sand with trace of oversizeIn our opinion, fill does not meet specifications as indicated by test numbers:-12'below finishgrdeFill test meets compaction specificationsTest #55a20Tan silty sand with trace of oversize-12'below finishgrdeWet Density (PCF)Average10.1Depth or Elevation (feet)Direct TransmissionDirect TransmissionMTE Nuclear Gauge No.:Compaction %FieldASTM D 6938Moisture Content %Dry Density (PCF)Backscatter / Direct TransmissionAverage115.8115.7 10.1LaboratoryMax Dry Density (PCF)OMC %12.812.8116.9116.9127.6127.598*99*20225 Cedar Valley Road, Suite 110 Ph 425.742.9360 Lynnwood, WA 98036 Fax 425.745.1737 10029 S. Tacoma Way, Suite E-2 Ph 253.584.3720 Tacoma, WA 98499 Fax 253.584.3707 7911 NE 33rd Drive, Suite 190 Ph 503.281.7515 Portland, OR 97211 Fax 503.281.7579 MTE 1400-2C, Rev 2, 4/1/08