HomeMy WebLinkAbout20090915_TIBInspector's Daily Report Project Name Date Shift Sheet 1 of 2 day Weather AM PM Inspector IDR Report # No. Foreman Traffic Control Supervisor Apprentices / Trainees Cat 962H Dozer 1 1 1 1 Photos/Videos taken today? Yes X No File: Inspector's Shift Hours From: To:Inspector's Signature Reviewed By Locator - " " " September 15, 2009 September 15, 2009 Tim Bergstrom 3:30 PM (TR 9.17.2009) Yesno Acceptable Date 11:00 AM Date Hitachi EX450 Excavator Location Structure#/Station Chevrolet Silverado Sevice Truck Bid Items Inspected Today/Field Note Flaggers Sunny and Clear 70F to 77F Tim Bergstrom 20090915 TB Takeuchi TB016 backhoe Operators Flaggers Laborers Carpenters Superintendent Superintendent - Trenchless Construction Services Operator - " " " John Deere Dozer 650J Dynapac 16 Ton Vibratory Roller Flat bed trailer 1669 -- NI Johnston 650 Water Truck Vactron TruckMix Truck w/ 2- ST500 mixer pumps Hitachi 270LC Pac Hoe IDR Sheet Item Number Material / Item Description Major Equipment on Project CDB Number & Classification Cat Dozer D6 Cat D5GXL Dozer John Deere Offroad Dump Trucks Ford Flat Bed Truck Subcontractor Number & Classification Case Series 2 580 Super M+ excavator/hoepack Kubota Super Series excavoator KX 161-3 Plan SheetItem Quanity Vermeer D24x40 series II Boring Machine w/50 10' Rods I-405/I-5 to SR169 Stage 2 - Widening and SR515 Interchange Project Traffic Control Yes Reviewed yes Signs Barricades no Inspector's Daily Report Project Number Sheet 2 of 2 Inspector IDR Report # IDR Sheet Tim Bergstrom I-405/I-5 to SR169 Stage 2 - Widening and SR515 Interchange Project Inspector's Notes September 15, 2009 Date 20090915 TB Personel Used on Project this day; 1)Steve Pollard -- Foreman Elcon 2) Matt Andresen -- Apprentice Elcon 3) Scott Schulz -- Apprentice/Laborer Elcon 4) Scott Pederson -- Operator T09082 Todays activities listed for Elcon at Talbot Onramp; Contractor excavated a 3 foot deep trench for conduit containg fiberoptics. Conduit containing fiberoptics were placed at the bottom of the trench and CDF was placed on top filling the trench approx. 6" below grade. The CDF exceeded the minimum depth of 24" over the conduit. The trench extends from station 1214+00 parallel to I-405 going north bound to station 1215+20. One two inch diameter conduit piping contains wiring for temporary lighting. There are also (2) 4 inch conduit pipings. One is for future use while the other contains interduct fiberoptic and twp (twisted wire pair). See attached Stoneway ticket detailing cement truck CDF load. A sample was obtained from the Defoor site for proctor analysis. Time also includes maintenance and sample storage. TImothy I. Bergstrom, Mayes Testing Engineers, Inc. tbergstrom@mayestesting.com 253-223-5360