HomeMy WebLinkAboutMFP19001991.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP19001991
IVR Number: 19001991
Permit Informaon
Permit Name:Verizon - MCI
Address/Locaon :04/12/2019Application Date:3223059071Parcel Number:11525 SE PETROVITSKY RD
Permit Type:04/24/2019Issue Date:Franchise
Permit Work Class:04/23/2020Expiration Date:Major Utility
Job Number:1703MOCF.006Franchise Type:Telephone
Description:Temporary use of 116th ave SE ROW for the purpose of attaching to 41 PSE poles, install 5775 LF of aerial strand, 4
Anchors and pull fiber optic cable. Restoration per City of Renton standards.
CONDITIONS OF OVERHEAD APPROVAL: 1. Any existing height violations within the Project Reach must be resolved
at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’ 6”.
2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking
place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the
City has approved a traffic control plan. 4. The new temporary aerial fiber lines within the Project Reach must be
converted to underground facilities within one year from the date of this temporary exemption decision, April 24, 2020,
at MCI’s cost.
Contacts
Name Address PhoneTypeBilling
HOLLY NORTH
MGC TECHNICAL CONSTULTING, INC
8521 154th Ave NE
REDMOND, WA 98052
B: (206) 618-0651Applicant
Matthew Sapp
Verizon - MCI
Contact
MASTEC NETWORK SOLUTIONS 210 Interstate North Pkwy, Suite 300
Atlanta, GA 30339
Contractor
Business License Number: 38949Construction Contractor: MASTENS876KN
HU BENJAMIN YENMIN 11863 175TH PL NE
REDMOND , WA 98052
Owner
Louise Popelka
Verizon MCI Buisness - Billing
3245 158th Ave SE
Bellevue, WA 98008
B: (425) 240-0238Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at
425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the
transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with
the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
MCImetro ACCESS TRANSMISSION SERVICES CORP.
1703MOCF.006_ROWI_REN_1188
ARNALDO BLANCO
(787) 349-2690
ablanco@fg-inc.net
ROW STARTING AT 11525 SE PETROVITSKY RD (PANTHER LAKE) ROWI RENTON PHASE I
TEMPORARY USE OF 116TH AVE SE RIGHT-OF-WAY FOR THE PURPOSE OF ATTACHING
TO 41 PSE POLES, INSTALL 5775 LF OF AERIAL STRAND, (4) ANCHORS AND PULL FIBER OPTIC CABLE.
5775
MASTEC NORTH AMERICA INC.(253) 722-9466
MASTENA991KJ
04/12/2019
4
MFP19001991
Scott Warlick 4/17/2019
Justin Johnson 4-19-2019
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
1703MOCF.006_ROWI_REN_1188
MASTEC NORTH AMERICA INC.
JERRY BINAM
151 STEWART RD SW, BLDG A, PACIFIC, WA, 98047 253-722-9466
JERRY.BINAM@MASTEC.COM
ROW OF 116TH AVE SE S OF SE PETROVITSKY RD
9:00AM - 3:00PM
MONDAY-FRIDAY
Reset FormPrint Form
04/12/19ARNALDO BLANCO
MFP19001991
4-19-2019
Justin Johnson
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
CAPITAL PROJECT #: 072443-001(PANTHER LAKE) ROWI RENTON PHASE IMCI PERMIT NUMBER: 1703MOCF.006_ROWI_REN_1188PROJECT STATUS: PERMITTINGSTATUS DATE: 03/05/2019MCImetroACCESS TRANSMISSION SERVICES CORPOUTSIDE PLANT CONSTRUCTIONPOLE ATTACHMENTSITE CODE: 1703MOCF.006ENGINEERING SERVICESRENTON, WASHINGTONMAKE READY ENGINEERINGMFP19001991
03/12/2019
A-01
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
SHEET INDEX
GENERAL PROJECT INFORMATION (A-SERIES)
COVER SHEET
SHEET INDEX
CONTACT INFORMATION (B-SERIES)
CONTACT INFORMATION SHEET
CONSTRUCTION PLANS (C-SERIES)
KEY MAP SHEET
SITE PLAN SHEET(S)
ADDITIONAL INFORMATION (D,E-SERIES)
GENERAL AERIAL CONSTRUCTION DETAILS
TRAFFIC CONTROL PLAN DETAILS
A-00
A-01
B-01
C-00
C-01 - C-07
D-01
E-01 - E-10 MFP19001991
03/12/2019
B-01
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
CONTACT INFORMATION
ONE CALL SYSTEM (UTILITY LOCATES)
MCI METRO INC.
UTILITIES
MCI UTILITY LOCATE
RAILROADS
FEDERAL GOVERNMENT
COUNTY GOVERNMENT
STATE GOVERNMENT
1-800-624-9675
CITY GOVERNMENT
OUTSIDE PLANT ENGINEERING:
OUTSIDE PLANT CONSTRUCTION:
RIGHT-OF-WAY:
CONTRACTS:
OTHERS:
ENGINEERING CONTRACTOR:
CONSTRUCTION CONTRACTOR:
SENIOR PROJECT ENGINEER:
LOUISE POPELKA
PROJECT SUPERVISOR:
FIELD CONSTRUCTION SUPERINTENDENT:
MANAGER:
AGENT:
MANAGER:
NAME OF FIRM:
MASTEC
PROJECT MANAGER:
ERIKA YOUNG
PROJECT SUPERVISOR:
CASEY CHRISTLIEB
NAME OF FIRM:
FORESITE GROUP
PROJECT MANAGER:
LUKE RICKEL
PROJECT ENGINEER:
ARNALDO BLANCO
(210)722-6429
(787)349-2960
(267)969-0345
(509)823-0965
(425)240-0238
AT&T LONG DISTANCE: DANIEL MCGEOUGH
AT&T METRO: CLIFF ROBERTS
(425)896-9830
(425)896-9851
AT&T MOBILITY/SINGULAR (SOUTH OF I-90): GARY TOPORKE
AT&T MOBILITY/CINGULAR: BILL LACOUNT
(253)680-2403
(360)395-5425
CENTURY LINK: IVAN ESMERAL
COMCAST: JILL LOOK
(425)427-9903
(206)396-6032
COAL CREEK UTILITY DISTRICT: PATRICK MARTIN
ELI/INTEGRA: ERIC LAYTON
(206)255-1961
(425)970-7763
FRONTIER COMMUNICATIONS NW: JAY SCHWAB (425)263-4019
LEVEL 3 COMMUNICATIONS: KRISHNA MITCHELL
ONEFIBER COMMUNICATIONS: BILL BODIN
(720)387-3342
(916)765-2074
OLYMPIC PIPELINE CO.: TIMOTHY FEHR
PUDGET SOUND ENERGY: ANDY SWAYNE
(425)427-9903
(425)462-3852
PUDGET SOUND ENERGY EMERGENCY DISPATCH
PSE/INFRASOURCE: AURELIE JOHANNSON
(888)225-5773
(425)466-4771
PSE/POTELCO: BOB CARLSEN
SEATTLE PUBLIC UTILITIES: RICHARD COX
(425)864-0496
(206)900-4434
T-MOBILE USA: NOTICE ADDRESS
VERIZON WIRELESS NW: LELAH VAGA
1-877-373-0093
(425)603-8275
XO COMMUNICATIONS/VERIZON WIRELESS: CHRISTOPHER MAPES
ZAYO FIBER SOLUTIONS: JOSEPH MORTON
(206)315-5014
(253)255-1917
PROJECT MANAGER:
CIARA MCDONNELL-RAY (425)606-7704
CITY OF RACOMA
Permitting Office (432)430-7200
1-800-424-5555
PROJECT ENGINEER:
BRAD LANDIS (425)229-3123
MFP19001991
C-07
C-06
C-05
C-04
C-03
C-02
C-01
03/12/2019
C-00
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
MFP19001991
139 ft.181 ft.217 ft.160 ft.160 ft.217 ft.217 ft.144 ft.103 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-01
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-01
C-02
MFP19001991
103 ft.177 ft.208 ft.71 ft.136 ft.63 ft.85 ft.129 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-02
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-01
C-02
C-03
MFP19001991
129 ft.90 ft.120 ft.235 ft.49 ft.136 ft.78 ft.67 ft.143 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-03
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-03
C-02
C-04
MFP19001991
219 ft.127 ft.143 ft.61 ft.93 ft.242 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-04
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-03
C-04
C-05
MFP19001991
211 ft.260 ft.175 ft.161 ft.199 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-05
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-05
C-04
C-06
MFP19001991
199 ft.158 ft.126 ft.187 ft.180 ft.166 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-06
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-06
C-05
C-07
MFP19001991
166 ft.117 ft.145 ft.POLE PROPOSED IN
SEPARATE PACKAGE
POLE FOR EVALUATION
SEPARATE PACKAGE
STRAND PROPOSED IN
SEPARATE PACKAGE
ANCHOR PROPOSED IN
PROPOSED ANCHOR
PARCELS
LEGEND:
PROPOSED STRAND
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
03/12/2019
C-07
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
NORTH
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
1" = 100'
C-06
C-07
MFP19001991
MCI CONSTRUCTION DETAILS/TYPICALS
GENERAL AERIAL CONSTRUCTION DETAILS
BUT NO LESS
LASHING WIRE GRIP AND CLAMP
TYPICAL DETAIL "H"
FROM POLE - 5 FEET OR MORE
SUSPENSION STRAND - PULL AWAY
TYPICAL DETAIL "E"
OR HANDHOLE LOCATION
POLE ARRANGEMENT FOR REPEATER
TYPICAL DETAIL "B"
18'' PREFERABLY
6'' MIN.
SHOULDER
BOLT
CURVED WASHER
AND STUD SHOULDER.
AND BETWEEN THE SECOND WASHER
STRAND AND PLACE IT BELOW THE STUD
FORM THE LASHING WIRE AROUND THE
AROUND STRAND
FORMING LASHING WIRE
JOINING 045 LASHING WIRE
TYPICAL DETAIL "G"
.625''
FORMING WIRE OVER
WIRE OFF .75'' BEYOND THE END OF THE
CUT THE FREE END OF THE LASHING
THE STUD AND TIGHTEN THE NUT.
SHARPLY. THEN FORM THE WIRE OVER
WIRE AND TAPPING THE STRAND
WIRE BY MAINTAINING A PULL ON THE
REMOVE ANY SLACK IN THE LASHING
CLAMP.
STUD OF CLAMP
CABLE SUSPENSION
CLAMP
GUY
SPACER NUT
WIRE GRIP
C LASHING
SHOULD FOLLOW LAY
OF STRAND WIRES UNDER
GRIP.
LASHING WIRE
NOTE:
THREADED STUD
GROOVED PLATES
CLAMPING NUT
CABLE SUSPENSION
X 2'' ROUND.8125''
CORNER SUSPENSION
CLAMP
WASHER
CABLE SUSPENSIONBOLT
CURVED WASHER
POLE TOP
GROUND LEVEL
POLE TOP VIEW
CURVED WASHER
CONDUIT ADAPTER.
BELOW SURFACE TO
2. FOR CONDUIT PL. U-GUARD
BELOW GROUND LEVEL
1. EXTEND U-GUARD MIN. 6''
POLE ARRANGEMENT FOR
POLE - LESS THAN 5 FEET
SUSPENSION STRAND - PULL TOWARD
TYPICAL DETAIL "D"
TYPICAL DETAIL "A"
2'' GALV. STEEL
2 GUY HOOK
CABLE SUSPENSION
BOLT
8''
CONDUIT
U-GUARD
NOTES:
AERIAL TO BURIED
24''
2''
GUY
BLACK IN COLOR
FIBER OPTIC CABLE
CAUTION TAG
CABLE SUPPORT AND .50'' SPACER
STAINLESS STEEL LASHER
(36'' RADIUS)
OR REPEATER
CONDUIT TO HH
CABLE
CABLE CLAMP
U-GUARD
GROUND LEVEL
4'' PVC BENDMIN.
42''
X X 24''X
WIRE CLAMP
CABLE LASHING 2''
X X
E/W 10" SCREW ANCHOR
.75" X 8' DEAD END
ANCHOR & DOWN GUY
TYPICAL DETAIL "I"
1ST LASHING WIRE
2ND LASHING WIRE
TERMINATING NUT
2ND WASHER
1ST WASHER
EX. GRADE
10'
TO CABLE REEL
GUY
SPACER NUT
2 GUY HOOK
THAN 10''
CABLE
GUY
SNAP
PULLING LINE
CABLE
GUY
BLACK IN COLOR
FIBER OPTIC CABLE
CAUTION TAG
INSTALLATION
TYPICAL CABLE & HARDWARE
CABLE LASHER AND CABLE GUIDE
TYPICAL ARRANGEMENT OF
TYPICAL DETAIL "F"
TYPICAL DETAIL "C"
MILE
AT STRAND TO SHEATH
CABLE LASHER
#6 INSULATED COPPER WIRE
POLE TOP VIEW
REPEATER OR SPLICE H.H.
ON POLE NEAREST
CONDUIT ON QUARTER
THE CABLE DIA.)
(X=MIN. OF 20 TIMES
POLE
CABLE GUIDE 4''APPROX.
.50'' SPACER
CABLE SUPPORT AND
STAINLESS STEEL LASHER
GROUND ROD
AND 10'X.75'' COPPER CLAD
BOND LOCATION
GROUND EVERY .25
2''GROUND WIRE CLAMP
10''
12''
10''
12''
GROUND LEVEL
POLE
WIRE CLAMP
CABLE LASHING
03/12/2019
D-01
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
MFP19001991
03/12/2019
E-01
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-02
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-03
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-04
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-05
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-06
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-07
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-08
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-09
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG 116TH AVE SE
MFP19001991
03/12/2019
E-10
PROJECT LOCATION:
PERMITTING ENTITY:
PROJECT ID NUMBER:OUTSIDE PLANT CONSTRUCTIONSHEET:
VERTICAL:
HORIZONTAL:
DRAWN BY:
ENGINEER:
DATE:
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,
THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE
PROPERTY OF MCI COMMUNICATIONS SERVICES, INC.. BOTH
BEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.
SCALE
REVISIONS
PROJECT:
RENTON
N/A
F. Colon
S. Dickson
DATE DESCRIPTION INITIALPANTHER LAKEAERIAL INSTALLATION11806 SE 192ND ST
RENTON, WA
1703MOCF.006_ROWI_REN_1188
N/A
GENERAL NOTES:
1.EACH SHEET REPRESENTS A
COMPLETE WORK EFFORT.
PROGRESSIVE WORK IS SPECIFIED
BY MATCH LINE CONTINUATION
ON SHEET
2.ALL DRIVEWAY ACCESS SHALL
REMAIN OPEN DURING WORK
ACTIVITY
3.SEPARATION DEVICES WILL BE
ADJUSTED TO MAINTAIN ACCESS
TO BUSINESS AND RESIDENTIAL
PROPERTIES DURING WORK
ACTIVITY
4.ALL WORK TO BE PERFORMED
DURING DAYTIME HOURS, UNLESS
TRAFFIC VOLUMES OR
MUNICIPALITY DICTATE
OTHERWISE
5.ALL SIGNS ARE 48”X48” BLACK ON
FLUORESCENT ORANGE UNLESS
OTHERWISE NOTED
6.TRAFFIC SHALL NOT BE STOPPED IN
ANYONE DIRECTION FOR MORE
THAN 5 MINUTES
7.IF NEED PEDESTRIAN WILL BE
ACCOMMODATED THROUGH THE
WORK ZONE
8.WORK AREA TO INCLUDE STAGING
AREA
TRAFFIC CONTROL PLAN
SHORT TERM STATIONARY WORK ZONE FOR NEW AERIAL REFERENCE PLAN SET
RURAL ROADS & URBAN ARTERIALS
URBAN STREETS 25 MPH OR LESS 100' +/- (2)
200' +/- (2)
35 / 40 MPH
25 / 30 MPH
350'
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE
INTERSECTIONS AND DRIVEWAYS.
(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
SIGN SPACING = X (1)
RURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS 25 30 35 40 45 50 55 60 65 70
SHOULDER
WIDTH
(feet)
10'
8'40 -
--
--
-
-
-
-
-
-
-40
40
60
60
90
90
90
USE A 3 DEVICES TAPER FOR SHOULDERS LESS THEN 8'
MPH
35/40
25/30
TAPER TANGENT
30
20
60
40
CHANNELIZATION DEVICESPACING (feet)
SPEED (MPH)25 30 35 40 45 50 55 60 65 70
LENGTH (feet)250 305 360 425 495 570 645 730155200
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.
PROTECTIVE VEHICLE (WORK VEHICLE) = R
SHOULDER WORK ALONG SE PETROVITSKY RD
MFP19001991
MFP19001991
April 5, 2019
City of Renton
Attn: Utility Systems Permit Center
1055 South Grady Way
Renton, WA 98057
Reference: 1703MOCF.006_ROWI_REN_1188
116th Ave SE, Renton, WA
Southbound from the intersection of 176th to the Kent City Limit (approximately 1.09
miles)
Dear Sir or Madam,
On behalf of MCImetro Access Transmission Services Corp, Foresite Group is requesting a variance related to the Renton Municipal Code, specifically to the Title IV Development Regulation, Chapter 6
(Street and Utility Standards), 4-6-090 (Utility Lines – Underground Installation), D. Exemptions, h. (Extensions, duplications, relocations or rebuilds to existing overhead electrical and communication facilities under the following conditions), ii (When there are existing overhead electrical or communication facilities that will not be removed (such as high tension wires), and the electrical and communication
facilities to be removed by undergrounding are parallel to facilities that will not be removed).1
Exemption to this code is not only of benefit to MCImetro Transmission, but more importantly to the City of Renton and its residents. Given that the permitting submitted in this package proposes a route of construction through a primarily residential area of the City of Renton, MasTec is requesting approval of aerial construction to not only permit the shortest route of construction, but also one that results in the
lowest impact to the residents of Renton. By constructing an aerial route, MasTec will be able to minimize the duration of construction, the traffic flow impact and the hardscape impact.
While it is understood that the City of Renton would prefer underground construction, precedence for aerial attachment of other communication services throughout Renton. MasTec has observed other communications carriers attached to PSE poles in Renton. While it is anticipated that some light to
normal make ready would be needed for the proposed path of construction, it is anticipated that the impact to the community would be less than if underground construction were required.
For reference, we have included snips of the proposed construction path and Google Earth street view images of the path.
If questions or concerns are had, please contact me at (787) 319-3712, fcolon@fg-inc.net.
Sincerely,
Francisco D. Colon, PE
Project Manager
Foresite Group Inc.
Phone: (787) 319-3712
Fax: (770) 368-1944
1 http://www.codepublishing.com/WA/Renton/html/Renton04/Renton0406/Renton0406090.html
MFP19001991
April 24, 2019
Arnaldo Blanco
MCImetro ACCESS TRANSMISSION SERVICES CORP.
3000 East Cesar Chavez, Suite 400
Austin, TX 78702
Via Email: ablanco@fg-inc.net
SUBJECT: Request for Undergrounding Exemption
(MCI 1703MOCF.006_ROWI_REN_1188, MFP19001991, 116th Avenue SE)
Dear Mr. Blanco:
The City of Renton has reviewed your request to grant MCImetro Access Transmission Services Corp. (MCI)
an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or
communication facilities shall be required to be installed underground, pursuant to the standards of the
section of RMC.
MCI proposes to temporarily locate approximately 5,775 lineal feet (Project Reach) of new overhead fiber
on existing Puget Sound Energy poles. The work will begin on an existing pole at the northeast corner of
SE Petrovitsky Road and 116th Avenue SE, then extend south along the east side of 116th Avenue SE, and
end approximately 115 lineal feet north of SE 192nd Street.
ANALYSIS: The City has considered the request for a temporary exemption from RMC 4-6-090(C). The
proposal would utilize existing poles and attach to the existing aerial path. Ordinance 5845 grants
MCImetro Access Transmission Services Corp., the right to construct, remove, replace, repair, and/or
restore any Facility, and may include, but are not limited to, digging and/or excavating to construct,
remove, replace, repair, and restore pipeline(s) and/or Facilities with the Franchise area.
In accordance with Resolution 4357, the City is requiring a joint use trench along 116th Avenue SE for all
new communication and electrical lines. MCI has been in discussions with the City of Renton to coordinate
the placement of the joint trench. City staff are in support of a temporary exemption with conditions in
accordance with RMC 4-6-090(D)(1)(i)(i), exemption due to technological difficulties, so as not to
adversely impact MCI due to the complexity of this joint trench coordination that may cause delay in the
franchisee provided service.
DECISION: The requested temporary exemption from underground utility installation requirements
RMC4-6-090 (C) in accordance with RMC 4-6-090(D)(1)(i)(i), exemption due to technological difficulties,
as requested by the applicant is approved with conditions subject to the conditions below.
MCI# 1703MOCF.006_ROWI_REN_1188
Page 2 of 2
April 24, 2019
Conditions of Approval:
1. Any existing height violations within the Project Reach must be resolved at the time of
construction. New aerial lines within the Project Reach must have a minimum vertical
clearance of 15’-6”.
2. Any abandoned or unused lines within the Project Reach must be removed at the time that
construction is taking place.
3. A traffic control plan must be separately submitted to the City, and no construction may take
place until the City has approved a traffic control plan.
4. The new temporary aerial fiber lines within the Project Reach must be converted to
underground facilities within one year from the date of this temporary exemption decision,
April 24, 2020, at MCI’s cost.
This decision to approve the temporary exemption with conditions is subject to a fourteen (14) day
appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision
must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, May 8, 2019.
Sincerely,
Brianne Bannwarth, PE
Development Engineering Manager
cc: C.E. “Chip” Vincent, CED Administrator
Gregg Zimmerman, PW Administrator
Jennifer Henning, Planning Director
Justin Johnson, Civil Engineer III
Scott Warlick, Engineering Specialist II
Holly Powers, Permit Technician
Pat Miller, Construction Inspection Supervisor
Franchise Permits